• 제목/요약/키워드: Secondary Effect

검색결과 2,537건 처리시간 0.03초

실험실 규모 순환유동층 연소로에서 2차공기 주입이 냉간유동에 미치는 영향 (Secondary Air Injection Effect on Cold Flow in a Laboratory-scale Circulating Fluidized Bed Combustor)

  • 장석돈;라승혁;황정호;강경태
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2000년도 제21회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.217-228
    • /
    • 2000
  • Circulating Fluidized Bed Combustor(CFBC) has been used for the incineration of waste sewage sludge and for the power generation. In this study hydrodynamic characteristics of two phase flow have been studied in a riser section of CFBC. A lab-scale riser is designed and SiC (Geldart type B) is used for solid particles. Experiments are performed by controlling the fluidization parameters including superficial velocity and secondary air to primary air ratio for determination of solid holdup profiles in the riser. Superficial velocities of each fluidization regime are well agreed with results predicted by a theoretical model. The results show that the axial solid holdup distributions calculated by measuring differential static pressures in the riser are found to show a basic profile described by a simple exponential function. Our flow regime during experiments mainly belongs to fast fluidization regime for particle size of 300${\mu}m$. As the SA/PA ratio increases, solid holdup in the lower dense region of the riser increases.

  • PDF

도시쓰레기와 유기성 하수 슬러지 혼합소각에 관한 연구 (Study on Co-incineration of Municipal Solid Waste and Organic Sludges)

  • 정종수;진성민
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2005년도 제31회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.238-244
    • /
    • 2005
  • This study performs the pilot-plant experiments to evaluate the effect of the oxygen enrichment on the co-incineration of municipal solid waste and organic sludge from a wastewater treatment facility. The design capacity of the stoker-type incinerator pilot-plant is 150 kg/h. Combustion chamber temperatures were measured as well as the stack gas concentrations, i.e., NOx, CO, and the residual oxygen. The maximum ratio of organic sludge waste to the total waste input is 30%. Also the oxygen-enriched air with 23% of oxygen in supplied air is used for stable combustion. As the co-incineration ratio of the sludge increased up to 30% of the total waste input, the primary and the secondary combustion chamber temperature was decreased $to900^{\circ}C$ (primary combustion chamber), $750^{\circ}C$(secondary combustion chamber), respectively, approximately $200^{\circ}C$ below the incineration temperature of the domestic waste only (primary: $1,100^{\circ}C$, secondary: $950^{\circ}C$). However, if the supplied air was enriched to 22% oxygen content in air, the incinerator temperature was high enough to burn the waste mixture with 30% sludge, which has the heating value of 1,600 kcal/kg.

  • PDF

수치해석 기법을 이용한 호흡 유량에 따른 사람의 기도 내 유동 특성 연구 (Numerical Analysis on the Flow Characteristics Considering the Inspiratory Flow Rate in a Human Airway)

  • 성건혁;유홍선
    • 대한의용생체공학회:의공학회지
    • /
    • 제33권4호
    • /
    • pp.177-183
    • /
    • 2012
  • The inspiratory flow rate of a human is changed with the amount of the workload. The flow characteristic is affected by the inspiratory flow rate. In the flow field of airway, the both of turbulence intensity and secondary flow affect the deposition pattern of particles which is important for the drug-aerosol targeting. Thus the analysis of the flow characteristic in a human airway is important. The purpose of this study is to investigate the effects of the inspiratory flow rate on the flow characteristics in a human airway. The tubular airway is consistent with the oral cavity, pharynx, larynx and trachea. The relatively inspiratory flow rate is used at each case of human states regarding the workload. By the effect of geometric airway changes, transition to turbulent airflow after the larynx can occur with relaminarization further downstream. The low Reynolds number k-${\omega}$ turbulence model is used for analysis with flow regime. As the inspiratory flow rate is larger, the turbulence kinetic energy and secondary flow intensity increase in airway. On the other hand, the area of recirculation zone is smaller.

BLEVE를 고려한 LPG 시설 Siting 분석 (Analysis of LPG Facility Siting Considering BLEVE)

  • 김태범;이경림;이주희;정승호;이건모
    • 한국안전학회지
    • /
    • 제31권2호
    • /
    • pp.26-32
    • /
    • 2016
  • In previous studies on LPG siting in Korea, the scope have not included the probability of the secondary events of adjacent LPG tanks or structures from an explosion source. Therefore, it is essential to first identify the phenomenon which can be caused by BLEVE and then, properly assess their effects to each target including secondary event. In this study, we calculated the effects from a potential BLEVE of 15 ton LPG tank causing damages of storage tanks (LPG), structures and human using Phast ver. 6.7 and then suggested three risk zones (Zone I, II, III) assuming the consequences such as overpressure, heat radiation and missile effect by fragments. Zone I and II are divided at the line of 50% occurrence of the secondary event. Zone II and III are divided by Individual Risk(IR). The zone approach in this study can be used for more effective and safer Land Use Planning (LUP) for the future.

EVALUATION OF PH CONTROL AGENTS INFLUENCING ON CORROSION OF CARBON STEEL IN SECONDARY WATER CHEMISTRY CONDITION OF PRESSURIZED WATER REACTOR

  • Rhee, In Hyoung;Jung, Hyunjun;Cho, Daechul
    • Nuclear Engineering and Technology
    • /
    • 제46권3호
    • /
    • pp.431-438
    • /
    • 2014
  • The effect of various pH agents on the corrosion behavior of carbon steel was investigated under a simulated secondary water chemistry condition of a pressurized water reactor (PWR) in a laboratory, and the steel's corrosion performance was compared with the field data obtained from Uljin NPP unit 2 reactor. All tests were carried out at temperatures of $50^{\circ}C-250^{\circ}C$and pH of 8.5 - 10. The pH at a given temperature was controlled by adding different agents. Laboratory data indicate that the corrosion rate of carbon steel decreased as the pH increased under the test conditions and the highest corrosion rate was measured at $150^{\circ}C$. This high corrosion rate may be related to high dissolution and instability of Fe oxide ($Fe_3O_4$) at $150^{\circ}C$. It was also found that an addition of ethanolamine (ETA) to ammonia was more effectivefor anticorrosion than ammonia alone, and that mixed treatment reduced 50% of iron or more at pHs of 9.5 or higher, especially in the steam generator (SG) and the moisture separator & re-heater (MSR).

Performance of modified graphite as anode material for lithium-ion secondary battery

  • Zheng, Hua;Kim, Myung-Soo
    • Carbon letters
    • /
    • 제12권4호
    • /
    • pp.243-248
    • /
    • 2011
  • Two different types of graphite, such as flake graphite (FG) and spherical graphite (SG), were used as anode materials for a lithium-ion secondary battery in order to investigate their electrochemical performance. The FG particles were prepared by pulverizing natural graphite with a planetary mill. The SG particles were treated by immersing them in acid solutions or mixing them with various carbon additives. With a longer milling time, the particle size of the FG decreased. Since smaller particles allow more exposure of the edge planes toward the electrolyte, it could be possible for the FG anodes with longer milling time to deliver high reversible capacity; however, their initial efficiency was found to have decreased. The initial efficiency of SG anodes with acid treatments was about 90%, showing an over 20% higher value than that of FG anodes. With acid treatment, the discharge rate capability and the initial efficiency improved slightly. The electrochemical properties of the SG anodes improved slightly with carbon additives such as acetylene black (AB), Super P, Ketjen black, and carbon nanotubes. Furthermore, the cyclability was much improved due to the effect of the conductive bridge made by carbon additives such as AB and Super P.

사각 덕트내 요철의 각도 변화에 따른 열전달 특성 (Augmented heat transfer in a rectangular duct with angled ribs)

  • 우성제;김완식;조형희
    • 대한기계학회논문집B
    • /
    • 제22권4호
    • /
    • pp.530-541
    • /
    • 1998
  • Heat transfer augmentation in a rib-roughened duct is affected by the rib configurations, such as rib height, angle of attack, shape, rib to rib pitch, and aspect ratio of a duct. These have been the main subjects in studying the average heat transfer and the friction loss of the fully developed flow. Investigating distributions of local heat transfer coefficients and flow patterns in a duct with the rib turbulators is necessary to find the characteristics of heat transfer augmentation and to decide the optimal configurations of ribs. In the present study the numerical analyses and the mass transfer experiments are performed to understand the flow through a rib roughened duct and the heat transfer characteristics with various angles of attack of ribs. A pair of counter-rotating secondary flow in a duct has a main effect on the lateral distributions of local mass transfer coefficients. Downwash of the rotating secondary flow, reattachment of main flow between ribs and the vortices near ribs and wall enhanced the mass transfer locally up to 8 times of that in case of the duct without ribs.

정사각단면 곡관덕트에 연결된 직관덕트에서 층류유동의 속도분포 (A Study on the Axial Velocity Profile of Developing Laminar Flows in a Straight Duct Connected to a Square Curved Duct)

  • 손현철;이행남;박길문;이홍구
    • 대한기계학회논문집B
    • /
    • 제28권9호
    • /
    • pp.1058-1065
    • /
    • 2004
  • In the present study, characteristics of steady state laminar flows of a straight duct connected to a 180$^{\circ}$ curved duct were examined in the entrance region through experimental and numerical analyses. For the analysis, the governing equations of laminar flows in the Cartesian coordinate system were applied. Flow characteristics such as velocity profiles, and secondary flows were investigated numerically and experimentally in a square cross-sectional straight duct by the PIV system and a CFD code(STAR CD). For the PIV measurement, working fluid produced from mosquito coils smoke. The experimental data were obtained at 9 points dividing the test sections by 400 mm. Experimental and numerical results can be summarized as follows. Critical Reynolds number, Recr which indicates transition from laminar steady flow to transition steady flow was 2,150. As Reynolds number, Re, was increased, dimensionless velocity profiles at the outer wall were increased due to the effect of the centrifugal force and the secondary flows. The intensity of a secondary flow became stronger at the inner wall rather than the outer wall regardless of Reynolds number.

맴돌이 자속의 영향을 고려한 철도차량용 선형유도전동기의 추력 특성 연구 (Thrust Characteristics Analysis considering the effect of the loops of flux in a LIM for Railway Transit)

  • 박찬배;이형우;한경희;이병송;권삼영;박현준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1605-1609
    • /
    • 2007
  • In the case of Linear induction motor(LIM), numerical analysis method like Finite Element Method(FEM) has been mainly used to analyze the travelling magnetic field problem which includes the velocity-induced electromotive force. If the problem including the velocity-induced electromotive force is analyzed by FEM using Galerkin method, the solution can be oscillated according to Peclet Number, which is determined by conductivity, permeability, moving velocity and size of mesh. Consequently, the accuracy of the solution can be low and the Loops of flux can be occurred at the secondary back-iron. These loops of flux occurred at the secondary back-iron does not exist physically, but it can be occurred in the analysis. In this case, the loops of flux can be generally removed by using Up-Wind method which is impossible to apply a conventional S/W tool(Maxwell 2D). Therefore, in this paper, authors examined the Loops of flux occurred at the secondary back-iron of LIM according to variations of Peclet Number, and analyzed whether these loops of flux affect on the thrust force characteristics of LIM or not.

  • PDF

AZ91합금의 조직(組織)과 시효특성(時效特性)에 미치는 Ca 및 Si의 영향(影響) (Effects of Ca, Si on the Microstructure and Aging Characteristic of AZ91 Alloy)

  • 지태구;김용규
    • 열처리공학회지
    • /
    • 제15권6호
    • /
    • pp.260-268
    • /
    • 2002
  • The effects of calcium and silicon on microstructure and aging characteristics of AZ91 magnesium alloy during T5 treatment was investigated. The addition of 0.88% calcium or 0.25% silicon to AZ91 alloy made dendrite cell smaller. Especially, silicon is more effectively acted as refinement of the dendrite cell than calcium. It is due to that $Mg_2Si$ precipitated at the dendrite cell boundary or in the matrix during T5 treatment of Si added AZ91 alloy retarded the growth of the secondary phase. In the mean while, without inducing the precipitates containing calcium, calcium was segregated mainly around secondary phase such as $Mg_{17}Al_{12}$ and partially dissolved in ternary eutectic (Mg-Al-Ca) structure. In the AZ91 alloy containing both silicon and calcium, more finely distributed $Mg_2Si$ in matrix homogeneously and much finer microstructure were obtained than those containing silicon or calcium. Hence, An AZ91 containing both silicon and calcium was more effective to retarding the growth of the secondary phase than the other AZ91 alloy such as AZ91 alloy containing silicon or AZ91 alloy containing calcium.