• Title/Summary/Keyword: Secondary Effect

Search Result 2,552, Processing Time 0.032 seconds

A Study on the Treatment of Combine Electron Beam in the Treatment of Breast Cancer Tumor Bed (유방암 Tumor bed 치료 시 혼합 전자선 치료 방법에 대한 고찰)

  • Lee, Geon Ho;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Du Sang;Ahn, Min Woo;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.51-56
    • /
    • 2019
  • Purpose: The usefulness of using single-electron radiation for secondary radiotherapy of breast cancer patients after surgery is assessed and the use of a combine of different energy. Methods and materials : In this study, 40 patients (group A) using energy 6 MeV and 9 MeV, and 19 patients (group B) using a combine of 9 MeV and 12 MeV were studied among 59 patients who performed secondary care using combine electronic radiation. Each patient in each group, 6 MeV, 9 MeV, Combine(6 MeV / 9 MeV) and 9 MeV, 12 MeV, Combine (9 MeV / 12 MeV) were developed in different ways, and the maximum doses delivered to the original hospital, D95, D5, and $V_3$, $V_5$, $V_{10}$ were compared. Result: The D95 mean value of Group A treatment plan was $785.33{\pm}225.37cGy$, $1121.79{\pm}87.02cGy$ at 9 MeV, and $1010.98{\pm}111.17cGy$ at 6 MeV / 9 MeV, and the mean value at 6 MeV / 9 MeV was most appropriate for the dose. The mean values of the low dose area $V_3$ and $V_5$ in the lung of the breast direction being treated were $3.24{\pm}3.49%$ and $0.72{\pm}1.55%$ at 6 MeV, the highest 9 MeV at $7.25{\pm}4.59%$, $3.07{\pm}2.64%$, the lowest at 6 MeV. Maximum and average lung dose was $727.78{\pm}137.27cGy$ at 6 MeV / 9 MeV, $49.16{\pm}24.44cGy$, highest 9 MeV at $998.97{\pm}114.35cGy$, $85.33{\pm}41.18cGy$, and lowest 6 MeV at $387.78{\pm}208.88cGy$, $9.27{\pm}6.60cGy$. The value of $V_{10}$ was all close to zero. Group B appeared in the pattern of Group A. Conclusion: Relative differences in low-dose areas of the lungs $V_3$ and $V_5$ were seen and were most effective in the dose transfer of tumor bed in the application of combined energy. It is thought that the method of using electronic energy in further radiation treatments for breast cancer is a more effective way to use the energy effect of limiting energy resources, and that if you think about it again, it could be a little more beneficial radiation treatment for patients.

Synthesis and Biological Activities of Myomodulin E and its Analogs (Myomodulin E 및 유도체들의 합성 및 생리활성)

  • Go, Hye-Jin;Seo, Jung-Kil;Seo, Hae-Jeom;Lee, Min-Jeong;Park, Tae-Hyun;Kim, Gun-Do;Park, Nam-Gyu
    • Journal of Life Science
    • /
    • v.22 no.4
    • /
    • pp.499-507
    • /
    • 2012
  • Previous work has characterized myomodulin A (MMA, PMSMLRLamide) and myomodulin E (MME, GLQMLRLamide) purified from the central nervous systems of the sea hare, $Aplysia$ $Kurodai$, using the anterior byssus retractor muscle (ABRM) of the mussel, $Mytilus$ $edulis$. The amino acid sequences of MMA and MME were the same as those of the myomodulin family peptide found in other mollusks. In this study, we synthesized MME, its derivatives, and other neuropeptides to investigate the relationship between the structure and biological activity of MME. The primary structures of MME's derivatives, Des[$Gly^1$]-MME, Des[$Gly^1,Leu^2$]-MME, and Des[$Gly^1,Leu^2,Gln^3$]-MME, were LQMLRLamide, QMLRLamide, and MLRLamide, respectively. MMA and synthetic peptides were tested on ABRM in $M.$ $edulis$ as well as muscle preparations in $Achatina$ $fulica$. MME displayed an inhibitory effect on phasic contraction of the ABRM at $1{\times}10^{-9}$ M or higher. MME also had a relaxing effect on the catch-tension of AMRM at $1{\times}10^{-8}$ M. Both MMA and its analogs stimulated a contractile response on the crop and relaxed the catch-relaxing response on the penial retractor muscle of $A.$ $fulica$. These results suggest that MME and its analogs have modulatory effects on various muscles of mollusks. This study has also laid the groundwork for future neural and circuit modulation studies during animal behavioral changes.

Effect of N-Application Level According to Seedling Density on Tiller Development, Yield and Quality in Direct-Seeded Rice on Flooded Paddy Surface (벼 담수표면산파 시 입모밀도에 따른 시비 조절이 분얼발생, 수량 및 품질에 미치는 영향)

  • Chung, Nam-Jin;Kim, Jeong-Il;Park, Jeong-Hwa;Kim, Je-Kyu
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.51 no.spc1
    • /
    • pp.52-57
    • /
    • 2006
  • This research was carried out to determine the effect of controlling nitrogen application on tiller development, yield, and quality of rice under scanty or excess seedling stands in direct-seeded rice on flooded soil surface. Seedling stand was set to 3 levels: scanty $(60/m^2)$, optimum $(120/m^2)$, and excess $(200/m^2)$. In the scanty plot, additional 4 kg/10a nitrogen was applied at the 3rd leaf stage to promote tiller development. On the other hand, applying 3.3 kg/10a nitrogen at 5th leaf stage in the excess plot was omitted to suppress tillering. Maximum numbers of tillers per plant were 15.2 and 8.6 in scanty and excess plots, respectively, as compared with 9.8 in optimum plot. Productive tiller rate decreased with the increase in number of seedling stands. Regardless of seedling density, the first tiller developed on the 3rd node of rice stem from the bottom. The primary tillers developed at 3, 4, 5, 6, 7 nodes in scanty plot, 3, 4, 5 nodes in optimum plot, and 3, 4 nodes in excess plot. The secondary tillers developed only in some portion of plants in scanty and optimum plots. The order of tiller emergence was negatively correlated to stem length, panicle length, non-productive tiller number, grain number per panicle, and fertility in scanty plot, and to perfect grain ratio in excess plot. In the optimum plot, however, the order of tiller emergence was not correlated to any of the mentioned characteristics. The perfect grain ratio of scanty plot was the highest because green-kerneled rice was a very small portion in the primary tillers as compared with those of optimum and excess plots. Yield indexes of scanty and excess plots were 99%, and 97%, respectively, of the yield (494 kg/10a) in optimum plot. In conclusion, when seedling stands are not at optimum level, rice yield and quality similar to optimum planting density level can be obtained by means of controlling nitrogen application.

A Study of Peripheral Blood and Bone Marrow Responses Depends on the Frequency of rhG-CSF Administration in Dogs (개에서 재조합 과립구 자극 인자 (rh G-CSF)의 투여 간격에 따른 말초혈액과 골수의 반응에 대한 연구)

  • Kim, Ji-Hyun;Jee, Cho-Hee;Won, Jin-Hee;Jung, Hae-Won;Moon, Jong-Hyun;Cho, Kyu-Woan;Kang, Byeong-Teck;Jung, Dong-In
    • Journal of Veterinary Clinics
    • /
    • v.31 no.2
    • /
    • pp.77-84
    • /
    • 2014
  • The present study evaluated that responses of peripheral and bone marrow depends on the frequency of recombinant human granulocyte colony-stimulating factor (rhG-CSF) administration in dogs. The rhG-CSF has been revealed that have a beneficial effect for dogs with myelosuppression secondary to chemotherapy or radiation but there were no studies about the frequency of administration in dogs. In this research, rhG-CSF was administrated $5{\mu}g/kg$ subcutaneously for each two-dogs group as follows: (1) every day for trial, (2) every other day for trial, (3) every third day for trial. The peripheral blood analysis including direct microscopic differential counts of one hundred cells was performed every day. Bone marrow aspiration was performed before administration of rh G-CSF, on the day of 0, 3, 9 and when the WBC counts were decreased within the normal range (day 12 or 13). Rh G-CSF was well-tolerated and showed no side effects in all dogs. According to the present study, $5{\mu}g/kg$ administration of rhG-CSF have cell-specific, frequency-related effect on bone marrow and peripheral blood. Furthermore, the effects of rhG-CSF administration on bone marrow sustained during the study and prolonged at least 3 days after discontinuing of rhG-CSF treatment.

Three-dimensional finite element analysis for the effect of retentive groove design on joint strength of casting connection (유지구 설계가 주조연결강도에 미치는 영향에 관한 삼차원 유한요소법적 연구)

  • Kim, Jung-Woo;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Mi-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.29-38
    • /
    • 2009
  • Statement of problem: A casting connection technique is widely used for repair, correction and addition to base metal framework. However, a casting connection technique may increase the risk of failure in clinical situations when high stresses exist. Purpose: The purpose of this study was to investigate the mechanical retentive groove design comparatively to increase the joint strength by using the three-dimensional finite element analysis model of a 3-unit fixed partial denture. Material and methods: Ten finite element models were constructed. (Model A: One retentive groove, Model B: Two retentive grooves, Model C: Three retentive grooves, Model D: Four retentive grooves, Model E: One horizontal groove and two vertical grooves, Model F: Two horizontal grooves and one vertical groove, Model G: One groove with the enlarged dimension, Model H: Two grooves with the enlarged dimension, Model I: One groove with the increased height, Model J: One groove with the increased width of base). The vertical force was applied to the mesial and the distal fossa to the casting connection of mandibular first molar. Results: The main factors, affecting joint strength of casting connection were both the retention between the primary cast and the secondary cast and the thickness of the primary cast remaining after preparing retentive groove. The increase of retentive force, according to the numbers and the dimension of retentive groove had an effect on distributing stress. However, in some cases, the increase of retentive force resulted in the increase of stress by reducing thickness of the primary cast in the connection area. Conclusion: The design of retentive groove that limits number of retentive groove for metal thickness and increases the depth of retentive groove for retention is highly recommended.

Pericentric Inversion of the X Chromosome in a Male with Azoospermia and in the Family of a Pregnant Female Carrier (무정자증을 보이는 남성과 정상 생식력을 가진 여성의 가계에서 관찰된 X 염색체의 Pericentric Inversion)

  • Lee, Bom-Yi;Ryu, Hyun-Mee;Lee, Moon-Hee;Park, Ju-Yeon;Kim, Jin-Woo;Lee, Joong-Shik;Kim, Hye-Ok;Kim, Min-Hyung;Park, So-Yeon
    • Journal of Genetic Medicine
    • /
    • v.5 no.2
    • /
    • pp.139-144
    • /
    • 2008
  • We report on two cases of pericentric inversion of X chromosome. The cases were found in a 40-year-old man with azoospermia and in a family of a 38-year-old pregnant woman. The first case with 46,Y,inv(X)(p22.1q27) had concentrations of LH, prolactin, estradiol, and testosterone that were within normal ranges; however, FSH levels were elevated. Testis biopsy revealed maturation arrest at the primary and secondary spermatocytes without spermatozoa. There were no microdeletions in the 6 loci of chromosome Y. For the second case, the cytogenetic study of thepregnant woman referring for advanced maternal age and a family history of inversion X chromosome was 46,X,inv(X)(p22.11q27.2). The karyotype of her fetus was 46,X,inv(X)(p22.1q27). Among other family members, the karyotypes of an older sister in pregnancy and her fetus were 46,X,inv(X)(p22.11q27.2), and 46,Y,?inv(X), respectively. The proband's father was 46,Y,inv(X)(p22.11q27.2). All carriers in the family discussed above were fertile and phenotypically normal. In addition, the ratio of inactivation of inv(X) by RBG-banding was discordant between the two sisters, with the older sister having only 4.1% of cells carrying inactivated inv(X) while the proband had a 69.5% incidence of late replicating inv(X). Therefore, we suggest that the cause of azoospermia in the first case might be related to inversion X chromosome with positional effect. Also, the family of the second case showing normal phenotype of the balanced inv(X) might be not affected any positional effect of genes.

  • PDF

Effect of High Protein Diet and Resveratrol Supplementation on the Nutritional Status and Immunoreactivity in the Irradiation-induced Inflammatory Rats (방사선 조사된 흰쥐에서 고단백식이와 레스베라트롤 첨가가 영양상태 및 면역기능 증진에 미치는 효과)

  • Kim, Kyoung-Ok;Chun, Mi-Son;Kang, Seung-Hee;Kim, Hyun-Sook
    • Journal of Nutrition and Health
    • /
    • v.42 no.7
    • /
    • pp.605-614
    • /
    • 2009
  • Most cancer patients are treated with surgery, chemotherapy or radiation as anticancer therapies. Especially in the case of radiation, these treatments produce adverse effects such as vomiting, weight loss, anorexia, normal cell damage and malabsorption. The major goal of this study was to determine the effect of irradiation on the nutritional and immune status in irradiated rats. A secondary goal was to determine the effectiveness of high protein diet (HP) and resveratrol (Res) in minimizing the adverse effects of radiation. Rats were divided into four groups: normal diet (NP), HP, NP + Res and HP + Res groups. Each group was further divided into subgroups that received radiation (RT group) and one that did not (non-RT group). Each diet was supplied from $12^{th}$ day prior to irradiation treatment with irradiation dose of 17.5 Gy. The diets were continued until 10th day after radiation treatment and animals were sacrificed. The radiation treatment showed decreased body weight, serum protein and HDL levels and increased TG and LDL levels in nutritional status. HP, NP + Res and HP + Res groups reduced the level of serum LDL and TG in irradiated rats. NP + Res and HP + Res groups increased reduced albumin level of serum in RT group. In case of immune status, the radiation treat-ment showed decreased WBC, lymphocytes and increased neutrophil and eosinophil levels. The levels of serum IL-2 and IL-6 were significantly increased by radiation, however the cytokine levels decreased in all dietary treatment groups. These results showed that high protein diet and resveratrol supplementation seem to minimize the adverse effects of radiation on lipid nutritional status and inflammation response in the rat model.

The Variation of Surface Dose by Beam Spoiler in 10 MV Photon Beam from Linear Accelerator (선형가속기 10 MV 광자선에서 산란판(Beam Spoiler) 사용 시 표면선량 변화)

  • Bae, Seong-Cheol;Kim, Jun-Ho;Lee, Choul-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • Purpose: The purpose of this study is to find a optimal beam spoiler condition on the dose distribution near the surface, when treating a squamous cell carcinoma of the head and neck and a lymphatic region with 10 MV photon beam. The use of a optimal spoiler allows elivering high dose to a superficial tumor volume, while maintaining the skin-sparing effect in the area between the surface to the depth of 0.4 cm. Materials and Methods: The lucite beam spoiler, which were a tissue equivalent, were made and placed between the surface and the photon collimators of linear accelerator. The surface-dose, the dose at the depth of 0.4 cm, and the maximum dose at the dmax were measured with a parallel-plate ionization chamber for $5{\times}5cm\;to\;30{\times}30cm^2$ field sizes using lucite spoilers with different thicknesses at varying skin-to-spoiler separation (SSS). In the same condition, the dose was measured with bolus and compared with beam spoiler. Results: The spoiler increased the surface and build-up dose and shifted the depth of maximum dose toward the surface. With a 10 MV x-ray beam and a optimal beam spoiler when treating a patient, a similer build-up dose with a 6 MV photon beam could be achieved, while maintaining a certain amount of skin spring. But it was provided higher surface dose under SSS of less than 5 cm, the spoiler thickness of more than 1.8 cm or more, and larger field size than $20{\times}20cm^2$ provided higher surface dose like bolus and obliterated the spin-sparing effect. the effects of the beam spoiler on beam profile was reduced with increasing depths. Conclusion: The lucite spoiler allowed using of a 10 MV photon beam for the radiation treatment of head and neck caner by yielding secondary scattered electron on the surface. The dose at superficial depth was increased and the depth of maximum dose was moved to near the skin surface. Spoiling the 10 MV x-ray beam resulted in treatment plans that maintained dose homogeneity without the consequence of increased skin reaction or treat volume underdose for regions near the skin surface. In this, the optimal spoiler thickeness of 1.2 cm and 1.8 cm were found at SSS of 7 cm for $10{\times}10cm^2$ field. The surface doses were measured 60% and 64% respectively. In addition, It showed so optimal that 94% and 94% at the depth of 0.4 cm and dmax respectively.

  • PDF

Reduction of Electron Contamination Using a Filter for 6MV Photon Beam (6MV 광자선에서 전자오염 감소에 관한 연구)

  • Lee, Choul-Soo;Yoo, Myung-Jin;Yum, Ha-Yong
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.159-165
    • /
    • 1997
  • Purpose : Secondary electrons generated by interaction between Primary X-rar beam and block tray in megavoltage irradiation, result in excess soft radiation dose to the surface layer To reduce the surface dose from the electron contamination, electron filters were attached under the tray when a customized block was used. Materials and Methods : Cu, Al or Cu/Al combined Plate with different thickness was used as a filter and the surface dose reduction was measured for each case. The measurement to find optimal filter was performed with $10m\times10cm$ field size and 78.5cm source to surface distance. The measurement points are positioned with 2mm intervals from surface to maximum build-up point. To acquire the effect of field size dependence on optimal electron filter, the measurement was performed from $4cm\times4cm\;to\;25cm\times25cm$ field sizes. Results : The surface dose was slowly increased by increasing irradiation field but rapidly increased beyond $15cm\times15cm$ field size. Al plate was found to be inadequate filter because of the failure to have surface dose kept lowering than the dose of deep area. Cu 0.5mm plate and Cu/Al=0.28mm/1.5mm combined plate were found to be optimal filters. By using these 2 filters, the absorbed dose to the surface layer was effectively reduced by $5.5\%,\;11.3\%,\;and\;22.3\%$ for the field size $4cm\times4cm,\;10m\times10cm,\;and\;25cm\times25cm$, respectively. Conclusion : The surface dose attributable to electron contamination had a dependence on field size. The electron contamination was increased when tray was used. Specially the electron contamination in the surface layer was greater when the larger field was used. 0.5mm Cu Plate and Cu/Al=0.28mm/15mm combined plates were selected as optimal electron filters. When the optimal electron filter was attached under the tray, excessive surface dose was decreased effectively The effect of these electron filters was better when a larger field was used.

  • PDF

The Effect of Surface Defects on the Cyclic Fatigue Fracture of HEROShaper Ni-Ti rotary files in a Dynamic Model: A Fractographic Analysis (Fractographic 분석을 통한 HEROShaper 니켈티타늄 전동 파일의 피로파절에 미치는 표면결함의 역할)

  • Lee, Jung-Kyu;Kim, Eui-Sung;Kang, Myoung-Whai;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.2
    • /
    • pp.130-137
    • /
    • 2007
  • This in vitro study examined the effect of surface defects on cutting blades on the extent of the cyclic fatigue fracture of HEROShaper Ni-Ti rotary files using fractographic analysis of the fractured surfaces. A total of 45 HEROShaper (MicroMega) Ni-Ti rotary flies with a #30/.04 taper were divided into three groups of 15 each. Group 1 contained new HEROShapers without any surface defects. Group 2 contained HEROShapers with manufacturing defects such as metal rollover and machining marks. Croup 3 contained HEROShapers that had been clinically used for the canal preparation of 4-6 molars A fatigue-testing device was designed to allow cyclic tension and compressive stress on the tip of the instrument whilst maintaining similar conditions to those experienced in a clinic. The level of fatigue fracture time was measured using a computer connected the system. Statistical analysis was performed using a Tukey's test. Scanning electron microscopy (SEM) was used for fractographic analysis of the fractured surfaces. The fatigue fracture time between groups 1 and 2, and between groups 1 and 3 was significantly different (p<0.05) but there was no significant difference between groups 2 and 3 (p>0.05). A low magnification SEM views show brittle fracture as the main initial failure mode At higher magnification, the brittle fracture region showed clusters of fatigue striations and a large number of secondary cracks. These fractures typically led to a central region of catastrophic ductile failure. Qualitatively, the ductile fracture region was characterized by the formation of microvoids and dimpling. The fractured surfaces of the HEROShapers in groups 2 and 3 were always associated with pre-existing surface defects. Typically, the fractured surface in the brittle fracture region showed evidence of cleavage (transgranular) facets across the grains, as well as intergranular facets along the grain boundaries. These results show that surface defects on cutting blades of Ni-Ti rotary files might be the preferred sites for the origin of fatigue fracture under experimental conditions. Furthermore this work demonstrates the utility of fractography in evaluating the failure of Ni-Ti rotary flies.