• Title/Summary/Keyword: Secondary Effect

검색결과 2,537건 처리시간 0.034초

고습의 흡입 유체일 때 이젝터의 성능 변화 (Humidity Effect on the Hydrogen Re-circulation Ejector Performance)

  • 제갈승;송성진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2589-2593
    • /
    • 2008
  • In a fuel cell vehicle using polymer electrolyte membrane fuel cell(PEMFC), hydrogen is over-supplied to gain higher stack efficiency. So it is needed considering fuel efficiency to re-circulate hydrogen which is not reacted in stack. And to re-circulate hydrogen, a blower or an ejector is used. Ejector re-circulation system has several merits compared with blower system, for example no parasite energy, simple structure and no lubrication system. But the secondary flow of an ejector in fuel cell vehicle, has high humidity because of crossover problem in stack. Therefore in this paper, ejector is designed by 1-D modeling and CFD with the primary and secondary flow of hydrogen. And the ejector which has the primary and secondary flow of air, is designed to have the same Reynolds number and Mach number at the nozzle exit as the hydrogen ejector's. And this air ejector is tested while the humidity of the secondary flow is varied.

  • PDF

E/V Shaft Cooling Method as a Stack Effect Countermeasure in Tall Buildings

  • Lee, Joonghoon;Song, Doosam;Jeong, Eunyoung
    • 국제초고층학회논문집
    • /
    • 제1권2호
    • /
    • pp.99-105
    • /
    • 2012
  • The higher the building height and the larger the temperature difference between the outdoor and indoor space, the more remarkable is the draft driven by the stack effect in high-rise buildings. Moreover, the stack effect can bring about the deterioration of habitability and the degradation of the performance of the indoor control system in high-rise buildings. In this study, as a measure to attenuate the stack effect, the E/V shaft cooling method was proposed and its performance was compared with the conventional stack effect control method for strengthening the air-tightness of the building using a numerical simulation method. The total decreasing ratios on the stack effect in a building were compared, and the probabilities of the secondary problems were analyzed. The results show that the E/V shaft cooling is very effective to decrease the stack effect in a high-rise building in terms of the reduction performance and application. Moreover, this method does not cause secondary problems, such as stack pressure transition to other walls, unlike the conventional stack effect mitigation method.

온도와 광도가 톨루엔-NOx-공기 혼합물의 광산화 반응에 미치는 영향의 비교 (Comparison of Temperature and Light Intensity Effects on the Photooxidation of Toluene-NOx-Air Mixture)

  • 주옥정;배귀남;최지은;이승복;김영성;문길주;윤순창
    • 한국대기환경학회지
    • /
    • 제23권3호
    • /
    • pp.353-363
    • /
    • 2007
  • To differentiate temperature effect from the light intensity effect on the formation of secondary products during the photooxidation of toluene-$NO_x$-air mixtures, steady-state air temperature was changed from $20^{\circ}C\;to\;33^{\circ}C$ at the same light intensity of $0.39min^{-1}$ in an indoor smog chamber. Smog chamber consisted of 64 blacklights and a $5.8m^3$ reaction bag made of Teflon film. Air temperature was controlled by an air-conditioning system. The starting time for rapid conversion of NO to $NO_2$ was slightly delayed with decreasing air temperature. In contrast to light intensity effect, the ozone formation time and the ozone production rate were insensitive to air temperature. Although the formation time for secondary organic aerosols was not changed, the particle number concentration increased with temperature. However, the newly formed secondary organic aerosol mass at lower temperature was higher than that at higher temperature. Since light intensity significantly affected the starting time and quantity of ozone and aerosol formation, it is considered that the temperature could contribute partly the quantity of aerosol formation during the photooxidation of toluene-$NO_x$-air mixtures.

도시하수 처리에 의한 미생물 오염의 제거효과에 관한 조사연구(I) -청계천 하수처리장을 중심으로- (An Analysis on Removal Effect of Biological Contaminants in the Process of Municipal Sewage Treatment System - On the Seoul Cheonggye Cheon Sewage Treatment Plant)

  • 유병태;정용
    • 환경위생공학
    • /
    • 제3권1호
    • /
    • pp.27-39
    • /
    • 1988
  • This investigation was carried out to evaluate the removal effect of biological contaminants for the municipal sewage treatment process at Cheonggye Cheon terminal plant which in the first plant for municipal sewage treatment in Seoul area. It was conducted in raw influent, primary treatment water and secondary treatment water from September, 1986 to July, 1987. The results were as follow; 1, The primary treatment could eliminate microbials for $65.38\%$ of total bacteria, $64.35\%$ of total coliform, $62.16\%$ of fecal coliform $69.48\%$ of pseudomonas and $64.70\%$ of fecal streptococci in averages for a year respectively. 2. The secondary treatment could eliminate microbials for $97.50\%$ of total bacteria, $97.30\%$of total coliform, $95.95\%$ of fecal coliform, $97.00\%$ of pseudomonas and $96.53\%$ of fecal streptococci in average for a year respectively. 3. In the detect rate of pathogenic agent, salmonella spp was decreased $12.5\%$ to $4.2\%$ in primary treatment and it was not detected in secondary treatment, shigella spp was detected $4.2\%$ in influent water but it was not detected in primary and secondary treatment. 4. In the seasonal variation of treatment effect, the removal of summer was the highest, and the removal of all item in winter was lower than the other seasons. 5. There was significant correlation between water temperature and microbal all items (P<0.05) $NH_3-N$ and Microbal items (P< 0.01) at raw water.

  • PDF

Concentration Variations in Primary and Secondary Particulate Matter near a Major Road in Korea

  • Ghim, Young Sung;Won, Soo Ran;Choi, Yongjoo;Chang, Young-Soo;Jin, Hyoun Cher;Kim, Yong Pyo;Kang, Chang-Hee
    • Asian Journal of Atmospheric Environment
    • /
    • 제10권1호
    • /
    • pp.32-41
    • /
    • 2016
  • Particle-phase concentrations were measured at 10, 80, and 200 m from the roadside of a national highway near Seoul in January and May 2008. The highway has two lanes each way, with an average hourly traffic volume of 1,070 vehicles. In January 2008, $PM_{10}$ concentrations decreased from 10 to 80 m but increased at 200 m. Black carbon (BC) decreased only slightly with distance due to the influence of biomass burning and open burning from the surrounding areas. In May 2008, the effect of secondary formation on both $PM_{10}$ and $PM_{2.5}$ was significant due to high temperatures compared with January. Because on-road emissions had little effect on secondary formation for a short time, variations in $PM_{10}$ concentrations became smaller, and $PM_{2.5}$ concentrations increased with distance. The effects of fugitive dust on PM concentrations were greater in May than in January when the mean temperature was below freezing. In the composition variations, the amounts of primary ions, organic carbon (OC), and BC were larger in January, while those of secondary ions and others were larger in $PM_{10}$, as well as $PM_{2.5}$ in May.

열교환기 내부 유로의 꺾임각 변화에 따른 국소 열/물질전달 특성 고찰 (Effects of Corrugation Angle on Local Heat/Mass Transfer in Wavy Duct of Heat Exchanger)

  • 장인혁;황상동;조형희
    • 대한기계학회논문집B
    • /
    • 제28권7호
    • /
    • pp.789-799
    • /
    • 2004
  • An experimental study is conducted to investigate the effects of duct corrugation angle on heat/mass transfer characteristics in wavy ducts of a primary surface heat exchanger application. Local heat/mass transfer coefficients on the wavy duct sidewalls are determined by using a naphthalene sublimation technique. The corrugation angles(${\alpha}$) of the wavy ducts are 145$^{\circ}$, 130$^{\circ}$, 115$^{\circ}$ and 100$^{\circ}$. And the Reynolds numbers based on the duct hydraulic diameter vary from 300 to 3,000. The results show that at the low Re(Re $\leq$1000), the secondary vortices called Taylor-Gortler vortices perpendicular to the main flow direction are generated due to effect of duct curvature. By these secondary vortices, high heat/mass transfer regions are formed on both pressure-side and suction-side walls. At the high Re(Re $\geq$ 1000), these secondary flows are vanished with helping flow transition to turbulent flow and the regions which show high heat/mass coefficients by flow reattachment are formed on suction side. As corrugation angle decreases, the local peak Sh induced by Taylor-Gortler vortices increase at Re $\leq$1000. At high Re(Re $\geq$ 1000), by the existence of different kind of secondary flows called Dean vortices, non-uniform Sh distribution appears along spanwise direction at the narrow corrugation angle (${\alpha}$=100$^{\circ}$). Average Sh also increase by the enhanced effect of secondary vortices and flow reattachment. More pumping power (pressure loss) is required with the smaller corrugation angle due to the enhancement of flow instability.

Characteristic Analysis of a Linear Induction Motor for a Lightweight Train According to Various Secondary Schemes

  • Lee, Hyung-Woo;Lee, Sung-Gu;Park, Chan-Bae;Lee, Ju;Park, Hyun-June
    • International Journal of Railway
    • /
    • 제1권1호
    • /
    • pp.6-11
    • /
    • 2008
  • This paper presents a performance characteristic analysis methodology for a linear induction motor used for a lightweight train. In general, an analytical method cannot provide accurate results in a linear motor because of large airgap, end effect, transverse edge effect, 3-dimensional configurations, large leakage, and so on. Besides, a numerical method requires lots of memory and solving time for transient analysis. However, the suggested methodology which is a kind of hybrid solution with an analytical method and a numerical method is very fast and accurate. Based on the methodology, 3-D FEM analyses for various design schemes of the secondary reaction plate have been done and from the analysis results, the best configuration for an urban railway transit is chosen.

  • PDF

저온재생기2열원2중효용(低溫再生器2熱源2重效用) Parallel Flow Cycle의 특성(特性) 해석(解析) (Simulation of the performance characteristics of the double effect Parallel flow cycle with secondary heat at the low temperature qenerator)

  • 최국광;이동호
    • 태양에너지
    • /
    • 제17권3호
    • /
    • pp.43-49
    • /
    • 1997
  • 본 연구는 저온재생기에서 용액 재생 열원으로 저온열을 보조열원으로 이용가능한 2열원 2중효용 흡수 사이클특성을 규명하기 위한 방법으로 병렬 용액 순환형 2중 효용 흡수 사이클 해석을 수행한다. 본 해석은 저온 재생기에서 필요한 재생열의 일부를 태양열 또는 배열 등과 같은 저온 보조 가열원을 이용하여 열의 유용성 검증을 위한 기초 수단으로 가열원 입구 온도, 용액 순환량을 변화시켜 2중효용 parallel flow cycle 의 특성을 규명한다.

  • PDF

Effect of Challenges with Class Size, Classroom Management and Availability of Instructional Resources on Science Teachers' Teaching Practices in Secondary Schools

  • Moluayonge, Gracemary Eloheneke;Park, Innwoo
    • 과학교육연구지
    • /
    • 제41권1호
    • /
    • pp.135-151
    • /
    • 2017
  • This study set out to investigate the challenges to science teacher's teaching practices in the Anglophone sub-system of education in Cameroon secondary schools. A sample of 331 of these teachers was selected using the purposive sampling method. Data was collected by use of a questionnaire and was subjected to inferential analysis. The major findings from the multiple regression were challenges associated with the size and management of a science class have an effect on the teaching practices of a science teacher. However, challenges with availability of instructional resources did not have an effect on science teaching practices. Recommendations to solve the identified drawbacks include the provision of more classrooms to accommodate the ever growing population of students and the organization of many seminars through which teachers could be educated on how to handle classroom problems and improvise when necessary.

멀티형 냉동 시스템의 정상상태 및 과도응답 특성 해석 (Analysis of the steady state and transient characteristics of a multi-type refrigeration system)

  • 이길봉;유근중;김민수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.439-444
    • /
    • 2005
  • Steady state simulation and dynamic simulation were performed to analyze the operational characteristics of a multi-type refrigeration system, Fully distributed model was adopted to simulate the steady state and transient responses of the system. The main aim was to see the effect of one indoor unit on the other unit. Numerical simulations were carried out for various operation conditions of an indoor unit - secondary fluid inlet temperature, mass flow rate and expansion valve opening. The results showed that the inlet temperature and mass flow rate of the secondary fluid of one indoor unit had minor effect on the operation of the other unit. However, the opening of the expansion valve had significant effect on the performance of the other unit.

  • PDF