• Title/Summary/Keyword: Secondary Air System

Search Result 272, Processing Time 0.025 seconds

Preliminary Results of Surveillance Data Processing for Design of Prototype ADS-B/TIS-B Validation Testbed (연구용 ADS-B/TIS-B Validation Testbed 설계를 위한 항공감시데이터 처리의 예비 결과)

  • Song, Jae-Hoon;Oh, Kyung-Ryoon;Kim, In-Kyu;Lee, Jang-Yeon
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.6
    • /
    • pp.539-547
    • /
    • 2008
  • In this paper, preliminary results for design of prototype ADS-ADS-B/TIS-B Validation Testbed (AVT) are described. Automatic Dependent Surveillance (ADS-B) is a novel surveillance concept using the Global Navigation Satellite System (GNSS) and a digital datalink. Air traffic information from ADS-B non-equipped aircraft is not acquired since ADS-B is a dependent surveillance. Traffic Information Service-Broadcast (TIS-B) provides surveillance data from Secondary surveillance Radar (SSR) for ADS-B non-equipped aircraft. AVT is based on ADS-B and TIS-B as an integrated platform for air traffic surveillance system for CNS/ATM.

  • PDF

A Study on Improved Operation of Apartment Heating System in a Machine Room (공동주택 기계실 난방설비 운전 개선 연구)

  • Seo, Jeong-Ah;Shin, Younggy;Kim, Yong-Ki;Lee, Tae-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.1
    • /
    • pp.38-42
    • /
    • 2017
  • This study proposes an idea for energy saving in apartment machine rooms. A conventional district heating system is equipped with constant-flow pumps and bypass valves to regulate pump differential pressure. Each family unit is equipped with a constant-flow on/off valve. This leads to excessive hot water circulation and a high return temperature. To reduce energy loss, this study assumes that each family unit is renovated with a heating valve which regulates the return temperature at $35^{\circ}C$. The hot water supply pump is also replaced with a pump with an inverter to vary flow rate. Expected energy savings is then estimated from field test data. According to the results, pump electricity consumption was reduced by 6,100 kWh for a family unit building over about half a year. The supply temperature can also be lowered by $5^{\circ}C$, which can contribute to a production of electricity of 10.3 kWh/ton of hot water.

The Modeling of inductive power collector for vehicle (차량용 유도전력 집전 장치의 특성해석)

  • Han, K.H.;Lee, B.S.;Kim, D.W.;Baek, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1610-1612
    • /
    • 2005
  • In this paper, the inductive power collector using electromagnetic induction for vehicle such as the PRT(Personal Rapid Transit) system is suggested and some ideas for power collector design to improve the power transfer performance are presented. The proposed the inductive power collector is used for the PRT system, which has a large air-gap and demands a large electrical power capability. But, low output power is generated due to a loosely coupled characteristic of the large air-gap. Therefore, double layer construction of secondary winding, which was divided in half to increase both output current and output voltage was suggested. Also, a model of power collector and parallel winding structure and a model of concentration/decentralization winding are presented, in addition, the performance of inductive power collector to alignment condition between the primary power line and the inductive power transformer was verified by computer simulation of 2kW model.

  • PDF

Characteristics of Chemical Species in Gaseous and Aerosol Phase Measured at Gosan, Korea During ABC-EAREX2005 (ABC-EAREX2005 기간 동안 제주도 고산지역 대기 중 가스상 및 입자상 물질의 분포특성)

  • Moon K.J.;Han J.S.;Kong B.J.;Lee M.D.;Jung I.R.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.6
    • /
    • pp.675-687
    • /
    • 2005
  • In this study, the cyclone/denuder/filter pack sampling system was used to measure the daily concentrations of water soluble inorganic compounds of fine ($D_{p}< 2.5\;{\mu}m$) and coarse ($D_{p}<10{\mu}m$m) size fractions of aerosol and related gases at Gosan super site during ABC-EAREX 2005. The mean concentrations for $HNO_{3},\;HNO_{2},\;NH_{3}$, were 0.39, 0.08, and $0.29\;{\mu}g/m^3$. respectively. Average concentrations of sulfate, nitrate, and ammonium in $PM_{2.5}$ were 3.39, 1.06, and $1.04\;{\mu}g/m^3$, which occupied about $26\%$ of total $PM_{2.5}$ mass. In particular, more than half of these ionic species were found in size of less than $2.5\;{\mu}m$. Gas phase nitric acid concentrations have shown high correlation coefficient with $HNO_{2}$(R=0.80) and $O_{3}$(R=0.78), implying the active photochemical reactions from its precursors. Equivalent molar ratios between major ion components, $NH_{4}\;^{+}/nss\;SO_4\;^{2-},(0.83\;for\;PM_{2.5},\;0.86\;for\;PM_{10})$, revealed that the existing forms of the secondary aerosols were probably $(NH_{4})_{2}SO_{4}\;and\;(NH_{4})_{3}H\;(SO_{4})_{2}$. Especially, $(NH_{4}\;^{+}+K^{+}+Ca^{2+}+Mg^{2+})/(NO_{3}\;^{-}+nss\;SO_{4}\;^{2-}) (0.99\;for\;PM_{2.5},\;1.05\;for\;PM_{10})$ indicated that some of them existed not only as $NH_{4}NO_{3}$ but also as $CaSO_{4}\;or\;KNO_{3}$, which pointed out the probability of influences from the abundant soil components during Asian dust (AD) periods. These neutralized types of secondary aerosols showed that pollutants could be aged and transported from a distance.

Flow Analysis of Building Pressurization System for Smoke Control (건물의 가압방연시스템 설계를 위한 유동해석에 관한 연구)

  • 김명배;한용식
    • Fire Science and Engineering
    • /
    • v.14 no.2
    • /
    • pp.14-20
    • /
    • 2000
  • Many pressurization systems are designed and built with the goal of providing a smoke-free escape route in the event of a building fire. A secondary objective is to provide a smoke-free staging area for fire fighters. In the present study, a computer program is developed to calculate pressure loss and flow rate at several building elements such as a room, a ]tabby a staircase and an air supply shaft. By the program as the dosing tool for the pressurization system, the capacity of the injection fan is calculated, and the design method is proposed for the optimization of the fan capacity.

  • PDF

A Study on the Mixture Formation in a Fuel Injection System (연료분사장치의 혼합기 형성에 관한 연구)

  • ;;;Lee, K. H.;Seo, Y. H.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.10
    • /
    • pp.2690-2698
    • /
    • 1995
  • Fuel atomization and mixture formation in an gasoline engine has influence on the engine performance and pollutant emission. The throttle valve installed in an intake system plays a greater role in control of mixture quantity in accordance with engine drive condition. In this study, the characteristics of secondary atomization developed at the downstream of the valves were observed using an image processing method. Two major kinds of valves, solid and perforated ones, are chosen in order to compare the valve performance with the experimental parameters of air flow rate, valve opening angle, and valve shapes. For the perforated valve, we can obtain the relatively small sized droplets, and nearly uniformed and dense distributed sprays with low loss coefficient than for the solid valve.

Study of Design Optimization of Reverse-Annular Type Combustor for Small Gas Turbine Engine (선회형 보염구조의 환형 역류형 연소기 최적화)

  • Park, Hee-Ho;Kim, Ki-Tae;Sung, Ok-Seok;Lim, Byeung-Jun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.401-405
    • /
    • 2011
  • Although the APU combustors were developed successfully, it could face many unexpected hardships in a engine or a system operated under the severe environment. This study is to be verified and settled by experimently and analytically of the problems and issues occurred in a variety of engine and system operation tests.

  • PDF

Practical method to improve usage efficiency of bike-sharing systems

  • Lee, Chun-Hee;Lee, Jeong-Woo;Jung, YungJoon
    • ETRI Journal
    • /
    • v.44 no.2
    • /
    • pp.244-259
    • /
    • 2022
  • Bicycle- or bike-sharing systems (BSSs) have received increasing attention as a secondary transportation mode due to their advantages, for example, accessibility, prevention of air pollution, and health promotion. However, in BSSs, due to bias in bike demands, the bike rebalancing problem should be solved. Various methods have been proposed to solve this problem; however, it is difficult to apply such methods to small cities because bike demand is sparse, and there are many practical issues to solve. Thus, we propose a demand prediction model using multiple classifiers, time grouping, categorization, weather analysis, and station correlation information. In addition, we analyze real-world relocation data by relocation managers and propose a relocation algorithm based on the analytical results to solve the bike rebalancing problem. The proposed system is compared experimentally with the results obtained by the real relocation managers.

Agroclimatic Maps Augmented by a GIS Technology (디지털 농업기후도 해설)

  • Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.12 no.1
    • /
    • pp.63-73
    • /
    • 2010
  • A comprehensive mapping project for agroclimatic zoning in South Korea will end by April 2010, which has required 4 years, a billion won (ca. 0.9 million US dollars) and 22 experts from 7 institutions to complete it. The map database from this project may be categorized into primary, secondary and analytical products. The primary products are called "high definition" digital climate maps (HD-DCMs) and available through the state of the art techniques in geospatial climatology. For example, daily minimum temperature surfaces were prepared by combining the climatic normals (1971-2000 and 1981-2008) of synoptic observations with the simulated thermodynamic nature of cold air by using the raster GIS and microwave temperature profiling which can quantify effects of cold air drainage on local temperature. The spatial resolution of the gridded climate data is 30m for temperature and solar irradiance, and 270m for precipitation. The secondary products are climatic indices produced by statistical analysis of the primary products and includes extremes, sums, and probabilities of climatic events relevant to farming activities at a given grid cell. The analytical products were prepared by driving agronomic models with the HD-DCMs and dates of full bloom, the risk of freezing damage, and the fruit quality are among the examples. Because the spatial resolution of local climate information for agronomic practices exceeds the current weather service scale, HD-DCMs and the value-added products are expected to supplement the insufficient spatial resolution of official climatology. In this lecture, state of the art techniques embedded in the products, how to combine the techniques with the existing geospatial information, and agroclimatic zoning for major crops and fruits in South Korea will be provided.

Influence of vacuum annealing on the secondary electron emission coefficient(${\gamma}$) from a MgO protective layer

  • Jeoung, J.M.;Leem, J.Y.;Cho, T.S.;Choi, M.C.;Ahn, J.C.;Kim, J.G.;Kim, Y.G.;Cho, D.S.;Kim, S.S.;Kim, T.Y.;Choi, S.H.;Chong, M.W.;Ko, J.J.;Kim, D.I.;Lee, C.W.;Kang, S.O.;Cho, G.S.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.113-114
    • /
    • 2000
  • The secondary electron emission coefficient(${\gamma}$) of vacuum annealed MgO films has been investigated by ${\gamma}-focused$ ion beam(${\gamma}-FIB$) system. The vacuum annealed MgO films have been found to have higher ${\gamma}$ values from 0.053 up to 0.121 than those for as-deposited MgO films from 0.026 up to 0.062 for $Ne^+$ ion energies ranged from 50eV to 200eV. Also it is found that ${\gamma}$ for air hold of vacuum annealed MgO layers for 24-hours is similar to that for vacuum annealed MgO films without any air-hold.

  • PDF