• Title/Summary/Keyword: Second harmonic reduction

Search Result 23, Processing Time 0.027 seconds

A Comparative of Improved Algorithm for IED of Power Transformer Protection (변압기 보호용 IED를 위한 개선된 알고리즘의 비교)

  • Park, Chul-Won;Park, Jae-Sae;Shin, Myong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.210-212
    • /
    • 2003
  • Conventional PDC relaying with 2nd harmonic restraint makes some doubt in reliability. It can contain second harmonic component to a large extent even during internal fault, and shows a tendency of relative reduction because of the advancement of transformer's core material. It is, therefore, necessary to develop a new algorithm as well as a new technique for the effective and accurate discrimination. This paper deals with advanced algorithm, fuzzy logic based relaying by using flux differential, and a new fault detection criterion logic scheme by using wavelet transform. To comparative analysis of proposed techniques, the paper constructs power system model including power transformer, utilizing the EMTP, and collects data through simulation of various internal faults and magnetizing inrush.

  • PDF

A study on the exhaust noise reduction of automobile with the active muffler (엑티브 머플러를 이용한 실차 배기 소음 저감에 관한 연구)

  • Hong, Jin-Seok;Shin, Jun;Kim, Heung-Sub;Song, Jin-Ho;Oh, Jae-Eung
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.283-287
    • /
    • 1996
  • The exhaust noise reduction of automobile with the active muffler is experimentally investigated. The control algorithm is the filtered-x LMS algorithm and the inverse algorithm with the adaptive line enhancer. Also, the control efficiency is increased with synthesized second harmonic engine frequency. In the experiment, the active muffler is applied to the end of exhaust system in automobile and the control with on-line secondary path modeling method(inverse algorithm) is compared the control of off-line secondary path modeling method. As secondary path transfer functions are changed, the experimental results show that the control performance with on-line method is more efficient than that with off-line method in the exhaust noise reduction of automobile.

  • PDF

RF Predistortion Techniques using 2nd Harmonics and Difference Frequency for Linearization of Power Amplifier (전력 증폭기의 선형화를 위해 2차 고조파와 차주파수를 이용한 전치왜곡 기술)

  • 박진상;조경준;장동희;김종헌;이병제;김남영;이종철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.4
    • /
    • pp.356-362
    • /
    • 2003
  • In this paper, we propose a predistortion technique which uses a novel combination of the second harmonic technique and the difference frequency technique to achieve independent control of the 3rd and 5th order intermodulation products generated by the PA. The second harmonic and difference frequency terms are generated using an envelope detector and two frequency multipliers. The RF predistorter has capability to independently control of the 3rd and 5th order intermodulation products so that high power amplifier is optimized for linear characteristics. From the measurement results, over the frequency band 2137.5 MHz to 2142.5 MHz, ACPR reduction of 11 dB is obtained for a single 30 dBm W-CDMA carrier.

Compact Multi-harmonic Suppression LTCC Bandpass Filter Using Parallel Short-Ended Coupled-Line Structure

  • Wang, Xu-Guang;Yun, Young;Kang, In-Ho
    • ETRI Journal
    • /
    • v.31 no.3
    • /
    • pp.254-262
    • /
    • 2009
  • This paper presents a novel simple filter design method based on a parallel short-ended coupled-line structure with capacitive loading for size reduction and ultra-broad rejection of spurious passbands. In addition, the introduction of a cross-coupling capacitor into the miniaturized coupled-line can create a transmission zero at the second harmonic frequency for better frequency selectivity and attenuation level. The aperture compensation technique is also applied to achieve a strong coupling in the coupled-line section. The influence of using the connecting transmission line to cascade two identical one-stage filters is studied for the first time. Specifically, such a two-stage bandpass filter operating at 2.3 GHz with a fractional bandwidth of 10% was designed and realized with low-temperature co-fired ceramic technology for application in base stations that need high power handling capability. It achieved attenuation in excess of -40 dB up to $4f_0$ and low insertion loss of -1.2 dB with the size of 10 mm ${\times}$ 7 mm ${\times}$ 2.2 mm. The measured and simulated results showed good agreement.

Low Phase Noise VCO Using Novel Harmonic Control Circuit Based on Composite Right/Left-Handed Transmission Line (혼합 우좌향 전송 선로 기반의 새로운 고조파 조절 회로를 이용한 저위상 잡음 전압 제어 발진기)

  • Choi, Jae-Won;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.1
    • /
    • pp.84-90
    • /
    • 2010
  • In this paper, a novel voltage-controlled oscillator (VCO) using the harmonic control circuit based on the composite right/left-handed (CRLH) transmission lines (TLs) is presented to reduce the phase noise without the reduction of the frequency tuning range and miniaturize the circuit size. The phase noise is reduced by the novel harmonic control circuit having the short impedances for the second- and third-harmonic components. The proposed harmonic control circuit is designed by using the CRLH TLs with the dual-band characteristic by the frequency offset and phase slope of the CRLH TLs. The high-Q resonator has been used to reduce the phase noise, but has the problem of the frequency tuning range reduction. However, the frequency tuning range of the proposed VCO has not been reduced because the phase noise has been reduced without the high-Q resonator. The miniaturization of the circuit size is achieved by using the CRLH TLs instead of the conventional right-handed (RH) TLs. The phase noise of VCO is -119.17 ~ -117.50 dBc/Hz at 100 kHz in the tuning range of 5.731 ~ 5.938 GHz.

A Study on Harmonics Reduction Method Considering Hormonic Voltage Limits on Each Bus using Shadow Price (잠재가격에 의한 모선별 고조파전압제약을 고려한 고조파 저감기법에 관한 연구)

  • Lee, Bum;Kim, Yong-Ha;Choi, Sang-Kyu;Lee, Jae-Geol;Yeon, Jun-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.87-93
    • /
    • 2003
  • This paper presents a new harmonics reduction methodology using shadow price. First, we employed shadow price of each bus to reduce harmonics effectively. Second, we developed a new algorithm which can reduce harmonics under limits at PCC and each bus. As a result economical design of filters and its location of the distribution system is possible. This method is applied to the real system, and the usefulness of the method is verified.

A Numerical Study on Acoustic Behavior in Baffled Combustion Chambers (배플이 장착된 로켓엔진 연소기의 음향장 해석)

  • Sohn, Chae-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.7
    • /
    • pp.966-975
    • /
    • 2002
  • Acoustic behavior in baffled combustion chambers is numerically investigated by adopting linear acoustic analysis. Partial blade baffle, which is a variant of blade baffle, and hub-blade baffle with six blades are employed as baffle models. Through modal analysis, natural frequencies of each acoustic mode in baffled chambers are calculated and the reduction in natural frequencies caused by baffle installation is examined. Through harmonic analysis, acoustic pressure responses of each chamber to acoustic oscillating excitation are shown. The first tangential mode is found to be most sensitive to acoustic oscillation. Acoustic damping effect of baffle is quantified by damping factor. Damping effect of hub-blade baffle is the most appreciable and damping factor of partial blade baffle is much lower than that of blade baffle. Damping effect of six-blade baflle on the second tangential mode is as much as on the first tangential mode and hub-blade baffle can damp out appreciably the first tangential as well as the first radial mode with the aid of hub.

Active vibration control of a flexible cantilever beam using Filtered-x LMS algorithm (Filtered-x LMS 알고리즘을 이용한 유연한 외팔보의 능동진동제어)

  • 박수홍;홍진석;김흥섭;오재응
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.3
    • /
    • pp.107-113
    • /
    • 1997
  • This paper presents the active control of a flexible cantilever beam vibration. The cantilever beam was excitied by a steady-state harmonic and white noise point force and the control was performed by one piezo ceramic actuator bonded to the surface of the beam. An adaptive controller based on filtered-x LMS algorithm was used and the controller was defined by minimizing the square of the response of error sensor. In the experiment, gap sensor was used as an error sensor while the sinusoidal or white noise was applied as a disturbance. In the case of sinusoidal input, more than 20 dB of vibration reduction was achieved over all range of the natural frequencies and it takes 5 seconds to control the vibration at first natural frequency and 1 second at other natural frequencies. In the case of white noise input, 7 dB of vibration reduction was achieved at the first natural frequency and good control performance was achieved in the considered whole frequency range. Results indicate that the vibration of a flexible cantilever beam could be controlled effectively when the piezo ceramic actuator was used with filtered-x LMS algorithm.

  • PDF

Friction tuned mass damper optimization for structure under harmonic force excitation

  • Nasr, Aymen;Mrad, Charfeddine;Nasri, Rachid
    • Structural Engineering and Mechanics
    • /
    • v.65 no.6
    • /
    • pp.761-769
    • /
    • 2018
  • In this work, an optimization method of Friction Tuned Mass Damper (FTMD) parameters is presented. Friction tuned mass dampers (FTMD) are attached to mechanical structures to reduce their vibrations with dissipating the vibratory energy through friction between both bodies. In order to exploit the performances of FTMD, the determination of the optimum parameters is recommended. However, the presence of Coulomb's friction force requires the resolution of a non-linear stick-slip problem. First, this work aims at determining the responses of the vibratory system. The responses of the main mass and of the FTMD are determined analytically in the sticking and sliding phase using the equivalent damping method. Second, this work aims to optimize the FTMD parameters; the friction coefficient and the tuned frequency. The optimization formulation based on the Ricciardelli and Vickery method at the resonance frequencies, this method is reformulated for a system with a viscous damping. The inverse problem of finding the FTMD parameters given the magnitude of the force and the maximum acceptable displacement of the primary system is also considered; the optimization of parameters leads to conclude on the favorable FTMD giving significant vibration decrease, and to advance design recommendations.

Structural Optimum Design and Dynamic Behavior Analysis of Steering Support Flange for Azimuth Thruster (소형선박용 Azimuth 추진장치의 Steering Support Flange의 구조적 최적설계 및 동적거동에 관한 연구)

  • Son, J.D.;Choi, W.H.;Jung, Y.G.;Choi, B.K.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.33-38
    • /
    • 2007
  • Recent, The propeller had high performance according as high performance of small ship. So, We has the development for azimuth thrusters. This Paper has structure improvement of steering support flange in azimuth thrusters. Steering support flange is very important part. because, Steering support flange supports all weight of azimuth thrusters. We has static & dynamic analysis of Steering support flange, and we discover the very safety. So, We has optimum design for the cost reduction. The first method of optimum design, We has the thickness reduce to 30mm from 5mm. Next method of optimum design, We had added stiffener. And we has the structure & dynamic behavior analysis. We had to dynamic behavior analysis. The first, We had to modal analysis. The result of 1st-modal analysis is that original model had to 76.48hz and new model had to 200.9hz. The second, We had to harmonic analysis. The result, We gave the thrust power to steering support flange. and We had to frequency analysis to $0{\sim}500hz$. The result, Deflection ration reduce to 16.64.

  • PDF