• 제목/요약/키워드: Seawater desalination

검색결과 194건 처리시간 0.044초

역삼투막을 이용한 해수담수화 플랜트에서 전처리 공정 기술 (An Overview of the Pretreatment Processes in Seawater Desalination Plants using Reverse Osmosis Membranes)

  • 안창훈;이원일;윤제용
    • 상하수도학회지
    • /
    • 제23권6호
    • /
    • pp.811-823
    • /
    • 2009
  • Seawater desalination process using a reverse osmosis (RO) membrane has been considered as one of the most promising technologies in solving the water scarcity problems in many arid regions around the world. To protect RO membrane in the process, a thorough understanding of the pretreatment process is particularly needed. Seawater organic matters (SWOMs) may form a gel layer on the membrane surface, which will increase a concentration polarization. As the SWOMs can be utilized as a substrate, membrane biofouling will be progressed on the RO membrane surface, resulting in the flux decline and increase of trans-membrane pressure drop and salt passage. In the middle of disinfection, an optimal chlorine dosage and neutralizer (sodium bisulfite, SBS) should be practiced to prevent oxidizing the surface of RO membranes. Additional fundamental research including novel non-susceptible biofouling membranes would be necessary to provide a guide line for the proper pretreatment process.

대규모 해수담수화 플랜트에서의 전처리공정 비용 분석 (Cost comparison of pretreatment processes in large SWRO desalination plant)

  • 김영민;김진호;이상호;이창규;박광덕;최준석
    • 상하수도학회지
    • /
    • 제27권5호
    • /
    • pp.555-560
    • /
    • 2013
  • A cost analysis method for pretreament processes of a large scale seawater desalination plant was considered using a cost estimation model, WaTER (Water Treatment Estimation Routine). This model is based on cost functions of U.S. EPA to conduct economic analysis of water treatment facilities. A virtual seawater desalination plant which has pretreatment production capacity of $100,000m^3$ per day was chosen as a model plant. Dual media filtration and microfiltration systems were compared as pretreatment process, and the following reverse osmosis process was modeled. As a result, microfiltration showed a price competitiveness in condition of operating with reverse osmosis process by reducing the loads of water treatment and membrane cleaning despite it's high annual cost.

국내 및 해외의 해수담수화 기술 비교분석 (Comparative Analysis of Seawater Desalination Technology in Korea and Overseas)

  • 황문현;김인수
    • 대한환경공학회지
    • /
    • 제38권5호
    • /
    • pp.255-268
    • /
    • 2016
  • 기후변화는 현재 사용되고 있는 지표수 및 지하수 등의 담수자원 외에도 새로운 수자원을 확보해야할 필요성을 증가시켰다. 해수담수화 시장은 이러한 변화에 따라서 매년 급증하고 있는 상황이며, 이에 발맞추어 2007년 해수담수화 플랜트 사업단이 국내에서 출범하였다. 2014년에 종료된 해수담수화플랜트 사업단은 증발식 해수담수화 기술에 치우친 국내 기술을 역삼투방식 해수담수화 기술로 선회할 수 있도록 이끌었다. 현재 세계 최고의 역삼투방식 해수담수화 기술 에너지 효율성은 약 $3.5kWh/m^3$ 전후로 조사된다. 기장 플랜트의 수준은 $3.8{\sim}4.0kWh/m^3$ 수준으로 비록 세계 최고 수준에는 미치지 못하나, 선두권이라 하기에는 부족함이 없는 것으로 사료된다. 한편, 세계 역삼투방식 해수담수화 기술은 평준화 수준에 이른 것으로 사료되며, 에너지 저감을 위해 새로운 기술을 개발하고자 경쟁중이다. 미래 해수담수 시장에서 경쟁할 것으로 예상되는 기술로 정삼투공정, 막증발법 등이 있으며, 이를 위해 국내에서도 정역삼투 융합공정 개발, 막증발법 및 얍력지연삼투등의 기술개발을 진행중에 있다. 이를 통하여 국내 기술수준을 $2.5kWh/m^3$까지 낮출 것으로 기대된다.

해수담수화 공정을 위한 가스하이드레이트-역삼투 공정의 에너지 소모량 평가 (Evaluation of energy consumption of gas hydrate and reverse osmosis hybrid system for seawater desalination)

  • 유현욱;김민석;임준혁;김종하;이주동;김수한
    • 상하수도학회지
    • /
    • 제30권4호
    • /
    • pp.459-469
    • /
    • 2016
  • Gas hydrate desalination process is based on a liquid to solid (Gas Hydrate, GH) phase change followed by a physical process to separate the GH from the remaining salty water. The GH based desalination process show 60.5-90% of salt rejection, post treatment like reverse osmosis (RO) process is needed to finally meet the product water quality. In this study, the energy consumption of the GH and RO hybrid system was investigated. The energy consumption of the GH process is based on the cooling and heating of seawater and the heat of GH formation reaction while RO energy consumption is calculated using the product of pressure and flow rate of high pressure pumps used in the process. The relation between minimum energy consumption of RO process and RO recovery depending on GH salt rejection, and (2) energy consumption of electric based GH process can be calculated from the simulation. As a result, energy consumption of GH-RO hybrid system and conventional seawater RO process (with/without enregy recovery device) is compared. Since the energy consumption of GH process is too high, other solution used seawater heat and heat exchanger instead of electric energy is suggested.

역삼투법 해수담수화 전처리 여과공정의 최적조건 (Determination of the optimum filtration conditions in pretreatment of seawater desalination by reverse osmosis)

  • 김승현;윤종섭;이석헌
    • 상하수도학회지
    • /
    • 제23권2호
    • /
    • pp.207-214
    • /
    • 2009
  • This study examines the optimum filtration conditions in pretreatment of seawater desalination by reverse osmosis. For this purpose, Masan bay seawater is treated through a gravity filter column while $FeCl_3$ is added as coagulant. The conditions of coagulantd osage, media depth, filtration rate, and backwash time are evaluated. The study results show that the filtrate quality improved with increasing coagulant dosage, but head loss rapidly increased. After 4mg/L, the unit filter run volume reduced to less than $200m^3/m^2$. Considering the head loss development, 4mg/L is determined as the optimum dosage. The better filtrate qualities are obtained with depth of 100cm than that of 80cm. The two stage filtration, which outperformed the single stage filtration, is suggested for treatment of Masan bay. The filtration rate of 5m/h is decided as the optimum condition considering the head loss development. At 10m/h, the filtrate quality deteriorated even though the extent was minimal, and head loss increased rapidly. The backwash time of 10 min is decided appropriate.

해수담수화 공정에서 역삼투막의 거동에 영향을 주는 요인 (Factors related to Performance of Reverse Osmosis Membrane in Seawater Desalination Process)

  • 박준영;홍성호;김지훈;정우원;남종우;김영훈;이창하;김형수
    • 상하수도학회지
    • /
    • 제25권2호
    • /
    • pp.171-176
    • /
    • 2011
  • Organic matters that comprise a tiny part of seawater generally occur over 50% of membrane fouling in Reverse Osmosis Process. This study evaluates Foundation efficiency of reverse osmosis membranes under brackish and seawater conditions and resistance of organic fouling. Moreover, analyzing the membrane surface through roughness, contact angle and zeta potential results in roughness and contact angle are proportional to flux decline rate (FDR), yet FDR has high value when zeta potential is low level. Furthermore, with various membrane fouling of different raw water conditions, the flux tends to improve when pH value is high and raw water which is complex with organic and cation pollutes membrane faster than organic separated raw water condition.

역삼투 방식의 해수담수화 플랜트 에너지 회수 기술 (Energy Recovery Technologies for Seawater Reverse Osmosis Desalination Systems : A Review)

  • 김영민;이원태;최준석;강만곤;이상호
    • 상하수도학회지
    • /
    • 제25권4호
    • /
    • pp.573-579
    • /
    • 2011
  • As rapid advances in technologies continue, seawater reverse osmosis (SWRO) desalination systems are now more energy-efficient than conventional thermal processes. Some SWRO desalination plants can achieve the specific energy consumption (SEC) below 2 kWh/$m^3$. Along with the development of new membranes and high-performance pumps, energy recovery devices (ERD), which recover the hydraulic energy of brine, have been developed to enhance energy efficiency. In this work, we reviewed general aspects of ERD technologies and their market trends. The advantages and disadvantages of various EDR technologies were compared to explore the future directions of ERD development.

해수 증발과정에서의 기체방출량 계산 (Calculation of non-condensable gases released in a seawater evaporating process)

  • 정광운;정한식;정효민;최순호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제41권3호
    • /
    • pp.182-190
    • /
    • 2017
  • 모든 액체는 소량의 기체성분들이 녹아있으며, 액체에 용해되는 기체의 양은 액체에 작용하는 주위압력에 기여하는 각 기체성분의 분압에 비례한다는 헨리의 법칙을 따른다. 따라서 다단증발식 해수담수화설비의 경우, 각 증발단의 운전온도와 압력은 다르며, 이 운전조건에 비례하여 해수에 용해되어 있던 기체들이 증발과정에서 방출되는데 주성분은 불응축기체인 이산화탄소, 질소, 산소 및 아르곤이다. 대류열전달의 입장에서는 불응축기체는 증발증기를 응축시키는 냉각기의 성능을 저하시키는 주요한 원인이기 때문에 증발과정에서 방출되는 불응축기체의 평가는 증발식 해수담수화설비에서 중요한 설계인자 중의 한가지이다. 증발식 해수담수화공정의 경우, 대부분의 증발기는 진공압력으로 유지되기 때문에 진공유지장치의 설계를 위해서는 증발과정에서 해수로부터 방출되는 불응축기체의 방출량을 평가하는 것이 매우 중요다. 본 연구는 불응축기체의 방출량을 정량적으로 계산하기 위해 수행하였으며, 연구결과에 따르면 불응축가스의 방출량은 후단으로 갈수록 감소하며, 담수생산량에 비례함을 알 수 있었다.

해수 담수화 플랜트 제어 시스템 구성 방안 연구 (A Study on Automatic Control Systems for Seawater Desalination Plants)

  • 주영덕;김경범;김진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.3-9
    • /
    • 2008
  • Recently, the plant industries are being activated and plant control systems use various technologies. Because the optimized design for the plants is very important for the reducing of operation and maintenance costs, automatic control systems become more important. Plant control systems consist of the master controller, the plant networks, the programming environment for engineering, monitoring software and the field devices. The control systems should have reliability, availability and safety. Modular architecture of hardware and software makes flexible configuration of the control systems. Each component should have diagnostic functions. It follows industrial standards and makes open systems. Open systems increase accessibility against the data which is distributed in the plants. The controllers including processor and communication modules use the up-to-date technology. They have real time and fault tolerant function by duplicating processors or networks. It also enables to make the distributed control systems. The distributed architecture makes more scalable main control system. Automatic control systems can be operated with better performance. In this paper, we analyzed the requirements of the seawater desalination plants and made some consideration facts for developing the optimized controller. Also we described the design concept of the main controller, which consists of several modules. We should validate and complement the design for the reliability and better performance.

  • PDF

Pretreatment in Reverse Osmosis Seawater Desalination: A Short Review

  • Valavala, Ramesh;Sohn, Jin-Sik;Han, Ji-Hee;Her, Nam-Guk;Yoon, Yeo-Min
    • Environmental Engineering Research
    • /
    • 제16권4호
    • /
    • pp.205-212
    • /
    • 2011
  • Reverse osmosis (RO) technology has developed over the past 40 years to control a 44% market share in the world desalting production capacity and an 80% share in the total number of desalination plants installed worldwide. The application of conventional and low-pressure membrane pretreatment processes to seawater RO (SWRO) desalination has undergone accelerated development over the past decade. Reliable pretreatment techniques are required for the successful operation of SWRO processes, since a major issue is membrane fouling associated with particulate matter/colloids, organic/inorganic compounds, and biological growth. While conventional pretreatment processes such as coagulation and granular media filtration have been widely used for SWRO, there has been an increased tendency toward the use of ultrafiltration/microfiltration (UF/MF) instead of conventional treatment techniques. The literature shows that both the conventional and the UF/MF membrane pretreatment processes have different advantages and disadvantages. This review suggests that, depending on the feed water quality conditions, the suitable integration of multiple pretreatment processes may be considered valid since this would utilize the benefits of each separate pretreatment.