• 제목/요약/키워드: Seawater Reverse Osmosis

검색결과 96건 처리시간 0.03초

여재 종류에 따른 역삼투법 해수담수화 시설 전처리 여과공정의 성능비교 (Comparison of the filtration performance by different media in pretreatment of seawater desalination by reverse osmosis)

  • 김승현;윤종섭;이석헌
    • 상하수도학회지
    • /
    • 제23권2호
    • /
    • pp.215-222
    • /
    • 2009
  • This study compares the performance of the filters with various media in pretreatment of seawater desalination by reverse osmosis. For this purpose, Masan bay seawater is used as raw water. The filter performance is evaluated by the filtrate quality and the head loss development. Five media is selected in this study: anthracite, $Filtralite^{(R)}$, sand, Pumice, $AFM^{(R)}$. These media are used in combination for dual media filter and alone for mono media filter. The comparison results show that NC0.8-1.6 is the best $Filtralite^{(R)}$. The dual media filter of NC0.8-1.6 and sand outperformed other filters in particle removal. The dual media filter of anthracite and sand showed good performance in organic removal. The mono media filter of Pumice produced the similar filtrate quality as the mono media filter of sand although the effective size of Pumice is considerably greater than that of sand. Due to big size, head loss development is maintained slow in the filtration of Pumice.

장래 해수수질 변화를 고려한 역삼투압 공정 전력비 예측 (The prediction of electricity for seawater reverse osmosis process considering future seawater quality)

  • 심규대;장부건;정준연;백승민;김동균
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2020년도 학술발표회
    • /
    • pp.243-243
    • /
    • 2020
  • 본 연구는 장래 유입수질 변화로 해수담수화(Desalination) 역삼투압(Seawater Reverse Osmosis) 공정의 전력비 예측 모델을 개발하고 별도의 해수담수화 추가공정이 필요한지 검토하였다. 플랜트 시설은 한번 설치되면 오랜 기간 운영이 되고, 주요 공정의 시설물 변경이 어려우며, 특히 해수담수화 시설의 경우에는 생활용수 및 공업용수를 수요자에 상시 공급함으로서 중간에 추가 시설물을 증설하거나 변경하기가 쉽지 않다. 따라서 해수담수화 시설의 계획 초기부터 현재의 유입수질 및 장래의 수질 변화를 예측하여 해수담수화 공정을 계획하는 것이 필요하다. 금회 검토는 해수온도 및 염분도 변화를 고려하여 서해에 위치한 대산산업단지 해수담수화 시설의 해수담수화 공정 전력비를 예측하였고, 입력 자료(온도 및 염분도)는 국가해양환경정보통합시스템(MEIS, Marine Environment Information System) 22년 과거자료(1997~2018년)를 이용하였다. 개발된 모형에 적용하여, 해수담수화에 필요한 전력비의 변화를 예측할 수 있으며, 이를 바탕으로 해수담수화 시설물 공정계획을 검토할 수 있었다. 금회 연구에서는 장래 수질변화 예측모형의 결과를 기반으로 해수담수화 시설물 공정을 제시하였다는데 의의가 있다.

  • PDF

하수재이용 및 해수담수화를 위한 정삼투-역삼투 융합공정의 탄소배출량 분석 (Analysis of Carbon Emission from a Forward Osmosis and Reverse Osmosis Hybrid System for Water Reuse and Seawater Desalination)

  • 전종민;김수한
    • 대한토목학회논문집
    • /
    • 제42권3호
    • /
    • pp.351-357
    • /
    • 2022
  • 본 연구에서는 하수재이용과 해수담수화를 동시에 진행할 수 있는 규모 1,000 m3/d의 FO-RO 융합공정과 동일한 규모의 기존 SWRO 공정의 탄소배출량을 계산하여 비교 분석하였다. FO-RO 융합공정은 FO 공정을 도입하여 RO 공정 원수를 희석시킬 수 있기 때문에 RO 공정의 요구 압력이 감소되고 이는 곧 에너지소비량 감소로 이어진다. 에너지소비량에 따른 탄소배출량은 FO-RO 융합공정이 SWRO 공정보다 -0.73 kgCO2(coal로 전력생산 시) 낮으며, FO 공정 추가 건설로 인해 발생되는 탄소배출량은 +0.16 kgCO2로 계산되어 FO-RO 융합공정의 총 탄소 배출량이 더 낮은 것으로 나타났다. 하지만, Coal나 oil과 같은 화석연료로 전력을 생산하지 않고, 전력생산 시 탄소배출량이 적은 nuclear나 solar 등으로 사용하면 FO-RO 융합공정의 총 탄소배출량이 SWRO 공정보다 더 높은 것으로 나타났다. 즉, 탄소배출량 관점에서는 전력생산 시 필요 재료(예: coal, oil, nuclear, solar 등)에 따라 친환경적인 공정 판단 여부가 결정되므로 FO-RO 융합공정 도입 필요성을 좌우하는 핵심 요소라고 할 수 있다.

역삼투압막 해수담수화 장치의 미네럴 분리 성능평가 (Efficiency Estimation for Desalination System of Seawater Using Reverse Osmosis Membrane)

  • 문덕수;정동호;김현주;신필권
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제8권2호
    • /
    • pp.60-66
    • /
    • 2005
  • 삼투압보다 높은 외부압력을 역으로 걸어주면 용매는 용질 농도가 낮은 용액쪽으로 이동하게 되는데 이 현상을 역삼투라고 한다. 역삼투 원리를 이용하여 40-70 기압의 압력구배를 구동력으로 해서 해양심층수의 담수화 적용성을 검토 조사하였다. 역삼투막의 성능에 영향을 미치는 유량과 염제거율에 관한 온도와 압력등 여러 인자들에 관하여 고찰하였다. 온도는 역삼투압 분리막의 유량에 비례하는 반면, 염제거율에 반비례하는 관계를 보이고 있다. 압력은 분리막의 유량과 염제거율에 비례하는 관계를 보였다. $Mg^{2+},\;Ca^{+2},\;Na^+,\;K^+$ 등과 같은 해수의 주성분 미네랄에 대한 역삼투 분리막의 분리특성은 해수와 같은 강전해질 용액에서 전하량이 큰 $Mg^{2+}$$Ca^{2+}$의 염제거율은 99% 이상으로 온도에 비례하는 관계를 보였다. 전하량이 적은 $Na^+$의 염제거율은 98%-99.5%로 2가 이온의 염제거율보다는 낮고, 전하량이 작은 $K^+$ 이온보다는 크게 나타났다. 약산이나 상온에서 기체상태나 유리상태로 존재하는 보론의 배제율은 역삼투 분리 막에서 상당히 낮게 나타나고 대부분 우리나라 먹는물의 수질 기준치를 상회한다. 그러나 보론의 배제율은 온도에 반비례하고 압력에 비례하는 관계를 이용하여 수온 $5^{\circ}C$, 압력 $70kgf/cm^2$의 운전조건에서 생산된 생산수의 보론 농도는 우리나라의 먹는물 수질 기준을 만족한다.

  • PDF

UF와 디스크필터를 전처리시설로 이용한 역삼투압해수담수설비의 평가 (Evaluation of Seawater Reverse Osmosis Desalination System with UF and Disk Filter as Pre-Treatment)

  • 양근모;임동훈;김준하;정형호
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제1권1호
    • /
    • pp.59-68
    • /
    • 2013
  • 본 연구에서는 한외여과막과 역삼투압막으로 이루어진 해수담수화장치를 구성하였다. 해수를 취수하여 디스크필터와 한외여과막을 이용한 전처리설비를 통과시켜 생산한 전처리수의 $SDI_{15}$와 탁도를 측정하여 역삼투압해수담수설비에 적합함을 밝혔다. 역삼투압해수담수설비의 부산물인 브라인을 전처리수와 혼합하여 역삼투압해수담수설비의 입구농도를 변화시켰다. 농도 변화실험에서, 해수농도가 역삼투압해수담수설비의 성능에 끼치는 영향을 실험으로 구하였다. 염배제율, 회수율, 생산수의 수질은 입구농도에 따라 많은 변화가 있었으며, 에너지소비량도 입구농도에 거의 선형적으로 상승하는 것을 실험으로 구하였다.

해수담수화 시장의 전망(정삼투-역삼투 융합기술 측면에서) (The Outlook for Forward Osmosis-Reverse Osmosis (FO-RO) Hybrid Desalination Market)

  • 김자겸;한지희;손진식;김승현
    • 상하수도학회지
    • /
    • 제30권5호
    • /
    • pp.521-532
    • /
    • 2016
  • Seawater desalination market after global economic crisis has been stalled due to the market uncertainties and decreased demand in desalination. It is important to review the status of the market and to estimate the appropriate share of Forward osmosis-Reverse Osmosis (FO-RO) hybrid desalination technology by figuring out the outlook of the desalination market. Main part of the desalination market will still be MENA (Middle East and North Africa) in the near future due to the fast population increase and high dependency of fossil fuel in the region. The market for FO-RO hybrid technology, however, might be smaller than the conventional SWRO desalination market anyway because of aesthetic issues from using wastewater as raw water and higher costs associated with capex. Therefore, it is essential to improve FO membrane performance and system operation technologies in order to make the hybrid technology attractive compared to the conventional SWRO technology.

역삼투 공정을 위한 모델링 총설 및 새로운 복합적 막오염도의 제안 (Review of Basics Reverse Osmosis Process Modeling: A New Combined Fouling Index Proposed)

  • Kim, Albert S.
    • 멤브레인
    • /
    • 제27권4호
    • /
    • pp.291-312
    • /
    • 2017
  • 해수담수화는 최근 전 세계적으로 대두되고 있는 물부족 현상을 해결하기 위한 최적 기술 중 하나이다. 막분리 및 투과 현상의 근본적인 이해는 차후의 막여과 기술의 발전을 위해서 뿐만 아니라, 현재 막기술 증진을 위한 통합적 디자인, 최적화 제어법, 그리고 중장기적 유지관리를 위해서도 매우 중요하다. 이에, 본 연구는 물질 전달 및 여과 현상에 대한 기존의 주요 모델들을 상세히 재검토하고, 통계물리학에 근간하여 주요 막분리 현상들을 이론적으로 분석하며, 원천적 모델에 기초한 물리적 의미와 그들이 실제 막공정에서 미치는 영향들에 대해서 함축적으로 토의하고자 한다. 이론적 재검토의 과정에서 새로이 유도된 복합적 막오염도(Combined Fouling Index (CFI))의 소개도 포함한다.

Effect of intermittent operation modes on performance of reverse osmosis (RO) membrane in desalination and water treatment

  • Yang, Heungsik;Choi, Jihyeok;Choi, Yongjun;Lee, Sangho
    • Membrane and Water Treatment
    • /
    • 제13권1호
    • /
    • pp.39-49
    • /
    • 2022
  • Seawater desalination is doubtlessly a viable option to supply fresh drinking water. Nevertheless, RO (reverse osmosis) desalination plants in specific areas may be intermittently operated to match the imbalance between water demand and supply. Although a handful of works have been done on other membrane systems, few studies have attempted to mitigate fouling in intermittent RO systems. Accordingly, the objectives of this paper were to examine the effect of the intermittent operation on RO fouling; and to compare four intermittent operation modes including feed solution recirculation, membrane storage in the feed solution, deionized water (DI) recirculation, and membrane storage in DI water. Results showed that intermittent operation reduced RO fouling under several conditions. However, the extents of fouling mitigation were different depending on the feed conditions, foulant types, and membrane lay-up methods. When the feed solution was recirculated during the lay-up, the restoration of the flux was less significant than that by the feed solution feed-up. The use of deionized water during the lay-up was effective to restore flux, especially when the feed solution contains scale-forming salts (CaSO4) and/or colloidal silica.

에너지 소모를 고려한 역삼투 해수담수화 플랜트 주요 성능인자 영향 분석 (Comprehensive Analysis of Major Factors Associated with the Performance of Reverse Osmosis Desalination Plant for Energy-saving)

  • 김지혜;이경혁;임재림
    • 멤브레인
    • /
    • 제29권6호
    • /
    • pp.314-322
    • /
    • 2019
  • 기후변화로 인해 가속화되고 있는 충남 지역 가뭄현상에 대응하고 대산 임해산업단지의 증가하는 용수 수요를 만족하기 위해서, K-water에서는 100,000 ㎥/일 규모 역삼투 해수담수플랜트 건설 사업을 추진하고 있다. 이에 본 연구에서는 해수담수플랜트 운영비용의 70% 이상을 담당하는 역삼투 공정 성능에 영향을 미치는 주요 인자에 대한 성능 분석을 수행하였다. 대산 지역 해수 염분농도 및 수온 변화 조건에서 RO 공정의 전력소모는 2.39 ± 0.13 kWh/㎥로 나타났으며, 막여과유속과 회수율이 낮을수록 전력소모가 절감되어 연간 운영비용이 감소하였다. 주요 막 제조사별 고유량 막의 성능 비교 결과, 전량 2단 여과공정(full two pass) 기준 생산수 TDS는 평균 3.84 mg/L로 양호하였고, 전력소모는 2.22 ± 0.13 kWh/㎥ 수준으로 확인되었다. 역삼투 공정 구성을 전량 2단 여과방식에서 partial 또는 split partial 방식으로 변경함에 따라 전력소모는 최대 0.29 kWh/㎥, 막모듈 설치비용은 최대 15.6% 절감 가능할 것으로 기대된다.