• Title/Summary/Keyword: Seasonal performance

Search Result 360, Processing Time 0.024 seconds

A study on the variations of water temperature and sonar performance using the empirical orthogonal function scheme in the East Sea of Korea (동해에서 경험직교함수 기법을 이용한 수온과 소나성능 변화 연구)

  • Young-Nam Na;Changbong Cho;Su-Uk Son;Jooyoung Hahn
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.1
    • /
    • pp.1-8
    • /
    • 2024
  • For measuring the performance of passive sonars, we usually consider the maximum Detection Range (DR) under the environment and system parameters in operation. In shallow water, where sound waves inevitably interacts with sea surface or bottom, detection generally maintains up to the maximum range. In deep water, however, sound waves may not interact with sea surface or/and bottom, and thus there may exist shadow zones where sound waves can hardly reach. In this situation, DR alone may not completely define the performance of each sonar. For complete description of sonar performance, we employ the concept 'Robustness Of Detection (ROD)'. In the coastal region of the East Sea, the spatial variations of water masses have close relations with DR and ROD, where the two parameters show reverse spatial variations in general. The spatial and temporal analysis of the temperature by employing the Empirical Orthogonal Function (EOF) shows that the 1-st mode represents typical pattern of seasonal variation and the 2-nd mode represents strength variations of mixed layers and currents. The two modes are estimated to explain about 92 % of the variations. Assuming two types of targets located at the depths of 5 m (shallow) and 100 m (deep), the passive sonar performance (DR) gives high negative correlations (about -0.9) with the first two modes. Most of temporal variations of temperature occur from the surface up to 200 m in the water column so that when we assume a target at 100 m, we can expect detection performance of little seasonal variations with passive sonars below 100 m.

A Study on Natural Ventilation Performance for a Double-Skin Facade System in Apartment Buildings (이중외피시스템을 적용한 고층 주거용건물의 자연환기 성능평가)

  • 석호태;김동화;최정민
    • Journal of the Korean housing association
    • /
    • v.14 no.3
    • /
    • pp.119-126
    • /
    • 2003
  • The purpose of this study is to evaluate the natural ventilation performance for variable external wind speed as a preliminary step to determining the seasonal operating modes of the Double-skin Facade System applied to apartment buildings. For this purpose, two simulation programs are used to compare the Double-Skin Facade System with the Double Sash Window. First, TAS is used to plan a schedule for natural ventilation during the intermediate season and to analyze the cooling loads. Second, CFD is used for a more detailed airflow analysis on a typical floor plan of the model building. The results of the simulations on natural ventilation performance show that the Double-Skin Facade System can reduce the cooling load by 10.5% compared to the Double Sash Window.

Lighting performance of high reflection wall within covered sunken garden (천창이 있는 선큰가든의 고반사율 벽면에 의한 심도 공간 채광성능)

  • Lim, Hong-Soo;Kim, Gon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.19-26
    • /
    • 2009
  • This study is performed by method for the influx of natural light in underground space. to solve the several negative underground issues make the covered courtyard and high reflected wall toward the adjacent space. for illuminance level test of sunken garden space, the adjacent space size is $15M{\times}9M{\times}12M$ sunken Garden with space to install the ceiling on the size of the companion light performance analysis, and seasonal changes derived by the light of changes in performance. In addition, increase the distance of the wall and the adjacent space and estimate the average at true time P.M12. The resulting data indicate that the road was an average lux DESKTOP RADIANCE of the modeling and analysis was conducted.

  • PDF

Performance Assessment of Building Envelopes I: Double Skin Facade (외피 친환경 성능평가 I: 이중외피)

  • Kim, Deuk-Woo;Park, Cheol-Soo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.77-82
    • /
    • 2009
  • Many countries have been interested in sustainable development of buildings for environmental preservation. Thus it is significant to assess building envelopes in terms of $CO_2$ emissions owing to Kyoto Protocol. In this paper, a Double Skin Facade(DSF) installed in a general office building was assessed by $CO_2$ emissions(one of the performance-based assessment). To predict $CO_2$ emissions caused by the building energy consumption, the dynamic simulation program(Energy Plus) and $CO_2$ emission factor was used. Because DSF has various airflow regimes, pre-simulation runs were conducted to decide proximate optimal airflow regimes depending on seasonal variation. It is shown that the DSF can achieve 17.1-36.5% of annual energy savings.

  • PDF

Treatment of $NH_3-N$ in Drinking Water Using Ion Exchange (이온교환을 이용한 음용수의 $NH_3-N$ 처리)

  • Chae, Yong-Gon
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.1
    • /
    • pp.67-72
    • /
    • 2008
  • Ion exchange performance to remove Ammonium in water was studied using commercially available strong acidic cationic exchange resin of $Na^+$ type in the batch and continuous column reactors. The performance was tested using the effluent concentration histories for continuous column or equilibrium concentrations for batch reactor as a function of time until resins were exhausted or reached ionic equilibrium between resin and solution. The results shoed that cationic exchange resin used in this study was more effective than activated carbon or zeolite for ammonium removal. Ammonium removal with the ion exchange resin temperature to be high qualitative recording minuteness but increases about seasonal change of temperature was judged with the public law where the adaptability is excellent. When the pH comes to be high at 11 degree, the ammonium was not effectively removed.

Ventilation and energy performance evaluation of the office building with variable air volume system (변풍량시스템이 적용된 사무소건물의 환기 및 에너지성능평가)

  • Kwon, Y.L.;Kwon, S.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.100-108
    • /
    • 1999
  • Variable air volume(VAV) system designed for improving interior environmental control has steadily evolved over the last 20 years. Major advantage of VAV system is that VAV technology allows a single system to provide simultaneous heating and cooling without a seasonal changeover. Research is carried out in order to study the influence on the energy consumption and ventilation performance of two kinds of office building with a mixing ventilation system. Data required for performance evaluation in these building is obtained from the central monitoring station and by measurement.

  • PDF

Evaluation of Performance of a Residential Air-Conditioning System Using Microchannel and Fin-and-Tube Heat Exchanger (마이크로채널과 핀 튜브 열교환기를 적용한 가정용 에어컨디셔너의 성능 평가)

  • Yun, Rin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.28-35
    • /
    • 2007
  • In this study the seasonal performance of a residential air conditioning system having either a fin-and-tube condenser or a microchannel condenser is experimentally investigated. A commercially available 7 kW capacity residential air conditioning system having a fin-and-tube condenser served as the base system. The test results show that the system with a microchannel heat exchanger has a reduced refrigerant charge amount of 10%, the coefficient of performance is increased by 6% to 10%, and the SEER is increased by 7% as compared with those of the base system. Moreover, the condensing pressure of the system is decreased by 100 kPa and the pressure drop across the condenser is decreased by 84%. The microchannel heat exchanger enhances the SEER of the residential air conditioning system by providing better heat transfers at reduced pressure drops.

A Experimental Study on the Seasonal Performance of Horizontal-type Geothermal Heat Exchange (수평형 지열교환기의 계절별 성능평가)

  • Woo, Sang-Woo;Hwang, Kwang-Il;Kim, Joong-Hun;Yang, Gi-Young;Shin, Seung-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.719-724
    • /
    • 2006
  • The purpose of this study is on the performance evaluation of horizontally installed HGHEX(Horizontal-type Geothermal Heat Exchanger) in the summer season and the winter season. Followings are the results. By the result of data acquisition at the site, $2.5{\sim}2.7^{\circ}C$ temperature differences are gained between supply pipes and return pipes of HGHEX in the summer season. And $0.5{\sim}1.5^{\circ}C$ temperature differences are gained from HGHEX in the winter season. With these temperature differences, heat quantity of rejection and absorption is calculated and the performance of HGHEX is evaluated according to the seasons.

  • PDF

Predictability of the Arctic Sea Ice Extent from S2S Multi Model Ensemble (S2S 멀티 모델 앙상블을 이용한 북극 해빙 면적의 예측성)

  • Park, Jinkyung;Kang, Hyun-Suk;Hyun, Yu-Kyung;Nakazawa, Tetsuo
    • Atmosphere
    • /
    • v.28 no.1
    • /
    • pp.15-24
    • /
    • 2018
  • Sea ice plays an important role in modulating surface conditions at high and mid-latitudes. It reacts rapidly to climate change, therefore, it is a good indicator for capturing these changes from the Arctic climate. While many models have been used to study the predictability of climate variables, their performance in predicting sea ice was not well assessed. This study examines the predictability of the Arctic sea ice extent from ensemble prediction systems. The analysis is focused on verification of predictability in each model compared to the observation and prediction in particular, on lead time in Sub-seasonal to Seasonal (S2S) scales. The S2S database now provides quasi-real time ensemble forecasts and hindcasts up to about 60 days from 11 centers: BoM, CMA, ECCC, ECMWF, HMCR, ISAC-CNR, JMA, KMA, Meteo France, NCEP and UKMO. For multi model comparison, only models coupled with sea ice model were selected. Predictability is quantified by the climatology, bias, trends and correlation skill score computed from hindcasts over the period 1999 to 2009. Most of models are able to reproduce characteristics of the sea ice, but they have bias with seasonal dependence and lead time. All models show decreasing sea ice extent trends with a maximum magnitude in warm season. The Arctic sea ice extent can be skillfully predicted up 6 weeks ahead in S2S scales. But trend-independent skill is small and statistically significant for lead time over 6 weeks only in summer.

Environmental Suitability for Conservation and the Risk Period for Fungal Damage of Wooden Cultural Heritages in Korea

  • Ik-Gyun IM;Gyu-Seong HAN
    • Journal of the Korean Wood Science and Technology
    • /
    • v.51 no.4
    • /
    • pp.295-308
    • /
    • 2023
  • This study applied a real-time IoT (Internet of Things) environmental monitoring system to wooden cultural heritages (WCHs) located in suburbs and forests in Korea. It automated the graphs of seasonal Temperature (T) and relative humidity (RH) changes inside the heritage structures and seasonal Performance Index (PI) values. While utilizing line graphs of the existing T and RH change trends and a bar graph expressing the PI values, this study examined the current status of the conservation environment inside the WCHs throughout the year and its diagnosis. Consequently, at higher latitudes, the organic cultural heritage repeatedly experienced large T fluctuations, and the risk of physical and chemical degradation of the materials was greater. However, the RH showed significant seasonal differences, even within the same latitude, indicating that the impact of latitude was not significant. Therefore, the staff in charge must manage RH by considering the surrounding environmental conditions and adjusting the internal environment of the structures. The PI values for the year-round T and RH inside the heritages were confirmed to only be a maximum of approximately 60% of the environmental suitability for conservation throughout the year, depending on the season. The relationship between the germination and growth potential period of xerophilic fungi and the monthly internal temperature and humidity in five heritages located at different latitudes was analyzed. As a result, we could thus determine that four particular months of the year (June-September) represent the periods with the highest risk of damage from xerophilic fungi in the country, regardless of latitude.