• 제목/요약/키워드: Seasonal energy efficiency ratio

검색결과 14건 처리시간 0.02초

인버터 압축기의 저속과 고속운전범위가 계절성능에 미치는 영향 (The effect on the seasonal performance of an inverter compressor with higher and lower operating range)

  • 박윤철;하도용;민만기
    • 설비공학논문집
    • /
    • 제10권2호
    • /
    • pp.173-179
    • /
    • 1998
  • An experimental study was conducted on the effect of compressor capacity control range of heat pump on the seasonal energy efficiency ratio with variation of the maximum and minimum compressor input frequencies. To obtain seasonal energy efficiency ratio, steady state test at the maximum, minimum and intermediate compressor speed and cyclic test at the minimum compressor speed should be conducted. Maximum input frequency was varied to 95Hz, 105Hz, and 115Hz, and the minimum input frequency was varied to 35Hz, 45Hz, and 55Hz. The seasonal energy efficiency ratio increased as the input frequency of the compressor decreased. The maximum input frequency had only slight effects on the SEER.

  • PDF

에어컨의 냉방기간 에너지 효율 산출을 위한 실험적 연구 (Experimental Study on the Cooling seasonal Performance Factor of Room Air-conditioner)

  • 이홍원;문정호;배영돈;박종철
    • 설비공학논문집
    • /
    • 제4권3호
    • /
    • pp.204-216
    • /
    • 1992
  • In most cases, EER(Energy Efficiency Ratio) is available to present energy efficiency of air-conditioners. But, EER is not adapt to measure energy efficiency at actual life environment because it is based on fixed temperature and humidity contditions. To overcome this disadvantage, there is need to introduce SEER(Seasonal Energy Efficiency Ratio) established at time varient temperature and humidity conditions. In this paper, SEER measurement method and conditions based on actual life environment of the country is introduced, and discussed SEER value about two air-conditioner type, that is, non inverter air-conditioner and inverter air-conditioner. As a result of, inverter air-conditioner was superior to non inverter air-conditioner at cooling seasonal energy efficiency.

  • PDF

부분부하 조건에서 히트펌프의 운전변수 최적화를 통한 냉방계절성능(SEER) 향상에 관한 실험적 연구 (An Experimental Study on the Performance Improvement of the Seasonal Energy Efficiency Ratio(SEER) of a Heat Pump by Optimizing Operating Parameters under Partial Load Conditions)

  • 최성경;이상헌;김선재;김용찬
    • 설비공학논문집
    • /
    • 제29권3호
    • /
    • pp.111-118
    • /
    • 2017
  • Performance factors such as the EER(Energy Efficiency Ratio) and the COP (Coefficient of Performance) are being replaced by seasonal energy efficiency factors, like the SEER (Seasonal EER) and the SCOP (Seasonal COP) to evaluate the performance of a heat pump by the time of the year. Seasonal performance factors, such as the CSPF (Cooling Seasonal Performance Factor) and the HSPF (Heating Seasonal Performance Factor) are used to describe the heat pump's performance during the cool and hot seasons. In this study, the optimization of all heat pump's operating parameters was experimentally conducted to enhance the SEER based on the EU standard (EN 14825). Moreover, the SEER was improved by the compressor frequency, as well as indoor and outdoor fan speeds. In addition, the performance characteristics of the heat pump were studied under partial load conditions. As a result, the SEER was enhanced by 17% when the compressor frequency was optimized. An additional 2% improvement was achievable with the optimization of indoor and outdoor fan speeds.

멀티형 에어컨의 기간에너지소비효율 평가규격에 관한 연구 (An Overview on Standards for Seasonal Performance Evaluation of Multi-type Air Conditioners)

  • 박윤철;문제명;홍주태
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.91-100
    • /
    • 2004
  • Energy efficiency evaluation method for a multi-type air conditioning system still has not been developed. In this study, analysis on capacity range and evaluating method of standards for air conditioners was conducted with world-wide Standards. It is not a proper approach to use the standards for residential air conditioner to multi type air conditioners. Some difficulties and problems are commented in this study with overview of the standards. Through the analytic research, an evaluating method for multi type air conditioner was suggested with Integrated Part Load Value (IPLV). The suggested concept for evaluating energy efficiency during part load condition considers building load pattern and operating hours of the system at different locations. Load was weighted in IPLV to consider not only the concept of occurrence of outdoor temperature such as bin method but also operation hours of the system. An experiment about the IPLV was conducted with variable air volume ducted type air conditioning system and multi-type system through modified code tester to give a glance at quantitative value of the IPLV.

바이패스방식을 이용한 용량가변 스크롤 압축기에 관한 연구 (A study on the Modulated Scroll Compressor by Bypass Method)

  • 김철환;신동구;박홍희
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.693-696
    • /
    • 2003
  • Hermetic Compressor circulates refrigerant with constant flow rate regardless of operation condition. so, at the operating condition requiring low cooling capacity, too much refrigerant flow deteriorates seasonal energy efficiency ratio(SEER). In this reason, modulated compressor is needed to improve SEER. Among many types of modulated compressor, non-inverter type modulated compressor is required for its low cost and easy to development. In the modulated scroll compressor by bypass method, EER steeply decreases for many loss like re-compression, changes of volume ratio, decrease of motor efficiency by torque variation. So. the range of modulation ratio for optimized SEER must be selected accompany with air conditioner set development.

  • PDF

히트펌프 성능 평가 동향과 국내 지열원 히트펌프 성능 평가 규격 및 제도 분석 (Analysis on the Performance Evaluation Trends of Heat Pumps and the Test Standards of a Geothermal Heat Pump in Korea)

  • 강신형;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권4호
    • /
    • pp.31-38
    • /
    • 2017
  • The heating and cooling air conditioning field has been increasing the problems of energy consumption and global warming in the world. A geothermal heat pump has been known as one of the highest efficient heating and cooling system. In this study, the analysis about the test standards of the geothermal heat pump of the Republic of Korea was executed. From the research, the following results were given. It is needed to address the domestic test standard for direct heat exchange geothermal heat pump. Water to air multi geothermal heat pump test standard was only developed in Korea. The test standard to calculate a seasonal energy efficiency ratio for cooling period and heat seasonal performance factor for heating period should be newly developed to estimate actual annual energy consumption and $CO_2$ emission.

공기조화기의 설계인자가 계절성능에 미치는 영향 (EFFECT OF DESIGN PARAMITERS ON SEASONAL PERFORMANCE OF AN A/C SYSTEM)

  • 박윤철
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.239-241
    • /
    • 2010
  • Performance evaluation for an air conditioning system is conducted at a specified test conditions. One is low temperature and the other is high temperature condition. Most of the manufactures tried to improve the performance at higher outdoor temperature. One of the reasons is that the customer wants to get ore capacity at high temperature climate. To cope with these kinds of demand, manufactures are tried to achieve higher capacity at high temperature with minimum power consumption even with same size of the system. Consequently, previous studies on performance of the air conditioning system are focused on capacity and performance improvement at high outdoor temperature.

  • PDF

천연가스의 계절별 변동유량을 고려한 이중터보팽창기 감압시스템을 이용한 전기에너지회수에 관한 연구 (A Study on the Recovery of Electricity Energy by Employing Double Turbo-Expander Pressure Reduction System to the Seasonal Variation of Natural Gas Flow Rates)

  • 박철우;유한빛;김효
    • 한국가스학회지
    • /
    • 제23권2호
    • /
    • pp.74-81
    • /
    • 2019
  • 천연가스 운송기지에서 전기에너지를 회수하기위하여 팽창 터빈시스템을 사용하는 것은 잘 알려진 기술이다. 터보팽창기의 효율은 천연가스의 유량과 터보팽창기 설계유량의 비에 따라 달라진다. 그러나 감압기지에서 계절적 공급패턴, 즉 여름에는 낮은 유량으로 반면에 겨울에는 높은 유량으로 공급되기 때문에, 단일 터보팽창기로는 낮은 유량의 천연가스로부터 감압에너지를 충분히 회수하기가 비효율적이다. 따라서 본 연구에서는 대용량과 소용량의 이중 터보팽창기의 새로운 개념을 제안하게 되었다. 본 연구에서는 저압 정압기지에서 팽창밸브의 평균 입구, 출구 압력조건인 18.5 bar에서 7.5 bar로 감압될 때 입구의 온도, 유량조건에 따라서 생산 가능한 전력을 이론적 배경을 통해 계산하였다. 최저 설계 효율 0.72에서 회수 가능한 전력생산량은 단일 터보팽창기로 운전될 때에는 12.4 MW이었으나, 여기서 제안한 이중터보팽창기에서는 16.1 MW로 약 30% 증가한 결과를 얻게 되었다.

Experimental Study on Characteristics of Two-Phase Flow through a Bypass Orifice Expansion Device

  • Choi, Jong-Min;Kim, Yong-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권1호
    • /
    • pp.11-19
    • /
    • 2001
  • To establish optimum cycle of the inverter-driven heat pump with a variation of frequency, the bypass orifice, which was a short tube haying a bypass hole in the middle, was designed and tested. Flow characteristics of the bypass orifice were measured as a function of orifice geometry and operating conditions. Flow trends with respect to frequency were compared with those of short tube orifices and capillary tubes. Generally, the bypass orifice showed the best flow trends among them. and it would enhance the seasonal energy efficiency ratio of an inverter heat pump system, Based on experimental data, a semi-empirical flow model was developed to predict mass flow rate through bypass orifices. The maximum difference between measured data and model`s prediction was within $\pm$5%.

  • PDF

바이패스 오리피스 팽창장치의 유동 특성에 관한 실험적 연구 (Experimental study on characteristics of two-phase flow through a bypass-orifice expansion device)

  • 최종민;김용찬
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.109-116
    • /
    • 1999
  • To establish optimum cycle of the inverter-driven heat pump with a variation of frequency, the bypass orifice, which is a short tube having a bypass hole in the middle, was designed and tested. Flow characteristics of the bypass orifice were measured as a function of orifice geometry and operating conditions. Flow trends with respect to frequency were compared with those of short tube orifices and capillary tubes. Generally, the bypass orifice showed the best flow trends among them, that will enhance the seasonal energy efficiency ratio of an inverter heat pump system. Based on experimental data, the semi-empirical flow model was developed to predict mass flow rate through bypass orifices. The maximum difference between measured data and model's prediction was within ${\pm}5%$.

  • PDF