• 제목/요약/키워드: Seasonal energy

검색결과 418건 처리시간 0.026초

Changes in Biochemical Components of Several Tissues in Sinonovacula constricta, in Relation to Gonad Developmental Phases (가리맛조개, Sinonovacula constricta의 생식소 발달단계에 따른 일부 조직의 생화학적 성분 변화)

  • Han, Ji-Soo;Kim, Jong-Bae;Lee, Chang-Hoon;Chung, Ee-Yung
    • The Korean Journal of Malacology
    • /
    • 제21권2호
    • /
    • pp.121-132
    • /
    • 2005
  • We investigated the reproductive cycle with gonad developmental phases of Sinonovacula constricta by histological observations, and seasonal changes in biochemical component of the adductor muscle, visceral mass, foot muscle and mantle were studied by biochemical analysis, from January to December, 2004. The reproductive cycle of this species can be classifed into five successive stages: early active stage (March to May), late active stage (May to July), ripe stage (July to September), partially spawned stage (August to October) and spentfinactive stage (October to March). Total protein content was the highest in the following order: adductor muscle, visceral mass, foot muscle, and mantle. Except for mantle, it was generally higher during the ripe and spawning stages, while lower during the spent/inactive stage. There were positive correlations in total protein contents among adductor muscle, foot muscle, and visceral mass. However, the correlations were not statistically significant. Total lipid content was the highest in the visceral mass; it was more than 5 or 6-fold higher than those in the adductor muscle, foot muscle, or mantle. The monthly change was also most dynamic in the visceral mass. It first Increased during the early active stage (March to May), decreased during late active stage (May to July), and then increased again rapidly during the spawning stage (September). There were a strong negative correlation in total lipid contents between foot muscle and adductor muscle (r = -0.634, p = 0.027), and a strong positive correlation between adductor muscle and mantle (r = 0.665, p = 0.018). Glycogen contents showed more or less similar pattern to total lipid contents in the adductor muscle, foot muscle, and visceral mass. It was higher during the early active and spawning stages, while lower during the late active and spent/inactive stages. There was no statistically significant correlation in glycogen contents among different tissues. Especially, total lipid content showed a negative correlationship between the foot muscle, adductor muscle, visceral mass and mantle. Therefore, these results indicate that the nutrient content of the foot muscle, adductor muscle, viseral mass and mantle changed in response to gonadal energy needs.

  • PDF

Classification System of Wetland Ecosystem and Its Application (습지생태계 분류체계의 검토 및 적용방안 연구)

  • Chun, Seung Hoon;Lee, Byung Hee;Lee, Sang Don;Lee, Yong Tae
    • Journal of Wetlands Research
    • /
    • 제6권3호
    • /
    • pp.55-70
    • /
    • 2004
  • The wetland ecosystem is a complex products of various erosion force, accumulation as water flows, hydrogeomorphic units, seasonal changes, the amount of rainfalls, and other essential element. There is no single, correct, ecologically sound definition for wetlands because of the diversity of wetlands and the demarcation between dry and wet environments occurs along a continuum, but wetland plays various ecosystem functions. Despite comprehensive integration through classification and impact factors there is still lacking in systematic management of wetlands. Classification system developed by the USFWS(1979) is hierarchical progresses from systems and subsystems at general levels to classes, subclasses, dominance types, and habitat modifiers. Systems and subsystems are delineated according to major physical attributes such as tidal flushing, ocean-derived salts, and the energy of flowing water or waves. Classes and subclasses describe the type of substrate and habitat or the physiognomy of the vegetation or faunal assemblage. Wetland classes are divided into physical types and biotic types. For the wise management of wetlands in Korea, this study was carried out to examine methodology of USFWS classification system and discuss its application for Korean wetland hydrogeomorphic units already known. Seven wetland types were chosen as study sites in Korea divided into some different types based on USFWS system. Three wetland types belonging to palustrine system showed no difference between Wangdungjae wetland and Mujechi wetland, but Youngnup of Mt. Daeam was different from the former two types at the level of dominant types. This fact means that setting of classification system for management of wetland is needed. Although we may never know much about the wetland resources that have been lost, there are opportunities to conserve the riches that remain. Extensive inventory of all wetland types and documentation of their ecosystem functions are vital. Unique and vulnerable examples in particular need to be identified and protected. Furthermore, a framework with which to demonstrate wetland characteristics and relationships is needed that is sufficiently detailed to achieve the identification of the integrity and salient features of an enormous range of wetland types.

  • PDF

Predicting the Goshawk's habitat area using Species Distribution Modeling: Case Study area Chungcheongbuk-do, South Korea (종분포모형을 이용한 참매의 서식지 예측 -충청북도를 대상으로-)

  • Cho, Hae-Jin;Kim, Dal-Ho;Shin, Man-Seok;Kang, Tehan;Lee, Myungwoo
    • Korean Journal of Environment and Ecology
    • /
    • 제29권3호
    • /
    • pp.333-343
    • /
    • 2015
  • This research aims at identifying the goshawk's possible and replaceable breeding ground by using the MaxEnt prediction model which has so far been insufficiently used in Korea, and providing evidence to expand possible protection areas for the goshawk's breeding for the future. The field research identified 10 goshawk's nests, and 23 appearance points confirmed during the 3rd round of environmental research were used for analysis. 4 geomorphic, 3 environmental, 7 distance, and 9 weather factors were used as model variables. The final environmental variables were selected through non-parametric verification between appearance and non-appearance coordinates identified by random sampling. The final predictive model (MaxEnt) was structured using 10 factors related to breeding ground and 7 factors related to appearance area selected by statistics verification. According to the results of the study, the factor that affected breeding point structure model the most was temperature seasonality, followed by distance from mixforest, density-class on the forest map and relief energy. The factor that affected appearance point structure model the most was temperature seasonality, followed by distance from rivers and ponds, distance from agricultural land and gradient. The nature of the goshawk's breeding environment and habit to breed inside forests were reflected in this modeling that targets breeding points. The northern central area which is about $189.5 km^2$(2.55 %) is expected to be suitable breeding ground. Large cities such as Cheongju and Chungju are located in the southern part of Chungcheongbuk-do whereas the northern part of Chungcheongbuk-do has evenly distributed forests and farmlands, which helps goshawks have a scope of influence and food source to breed. Appearance point modeling predicted an area of $3,071 km^2$(41.38 %) showing a wider ranging habitat than that of the breeding point modeling due to some limitations such as limited moving observation and non-consideration of seasonal changes. When targeting the breeding points, a specific predictive area can be deduced but it is difficult to check the points of nests and it is impossible to reflect the goshawk's behavioral area. On the other hand, when targeting appearance points, a wider ranging area can be covered but it is less accurate compared to predictive breeding point since simple movements and constant use status are not reflected. However, with these results, the goshawk's habitat can be predicted with reasonable accuracy. In particular, it is necessary to apply precise predictive breeding area data based on habitat modeling results when enforcing an environmental evaluation or establishing a development plan.

Lessons from Cross-Scale Studies of Water and Carbon Cycles in the Gwangneung Forest Catchment in a Complex Landscape of Monsoon Korea (몬순기후와 복잡지형의 특성을 갖는 광릉 산림유역의 물과 탄소순환에 대한 교차규모 연구로부터의 교훈)

  • Lee, Dong-Ho;Kim, Joon;Kim, Su-Jin;Moon, Sang-Ki;Lee, Jae-Seok;Lim, Jong-Hwan;Son, Yow-Han;Kang, Sin-Kyu;Kim, Sang-Hyun;Kim, Kyong-Ha;Woo, Nam-Chil;Lee, Bu-Yong;Kim, Sung
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • 제9권2호
    • /
    • pp.149-160
    • /
    • 2007
  • KoFlux Gwangneung Supersite comprises complex topography and diverse vegetation types (and structures), which necessitate complementary multi-disciplinary measurements to understand energy and matter exchange. Here, we report the results of this ongoing research with special focuses on carbon/water budgets in Gwangneung forest, implications of inter-dependency between water and carbon cycles, and the importance of hydrology in carbon cycling under monsoon climate. Comprehensive biometric and chamber measurements indicated the mean annual net ecosystem productivity (NEP) of this forest to be ${\sim}2.6\;t\;C\;ha^{-1}y^{-1}$. In conjunction with the tower flux measurement, the preliminary carbon budget suggests the Gwangneung forest to be an important sink for atmospheric $CO_2$. The catchment scale water budget indicated that $30\sim40%$ of annual precipitation was apportioned to evapotranspiration (ET). The growing season average of the water use efficiency (WUE), determined from leaf carbon isotope ratios of representative tree species, was about $12{\mu}mol\;CO_2/mmol\;H_2O$ with noticeable seasonal variations. Such information on ET and WUE can be used to constrain the catchment scale carbon uptake. Inter-annual variations in tree ring growth and soil respiration rates correlated with the magnitude and the pattern of precipitation during the growing season, which requires further investigation of the effect of a monsoon climate on the catchment carbon cycle. Additionally, we examine whether structural and functional units exist in this catchment by characterizing the spatial heterogeneity of the study site, which will provide the linkage between different spatial and temporal scale measurements.

Developing Food List for Risk Assessment of Contaminants in Korean Foods (식품으로부터의 오염물질 섭취량 및 위해도 평가를 위한 대표식품 선정)

  • Lee, Haeng-Shin;Kim, Bok-Hee;Jang, Young-Ai;Park, Seon-Oh;Oh, Chang-Hwan;Kim, Ji-Young;Kim, Hee-Yun;Chung, So-Young;Sho, Yoo-Sub;Suh, Jung-Hyuck;Lee, Eun-Ju;Kim, Cho-Il
    • Korean Journal of Food Science and Technology
    • /
    • 제37권4호
    • /
    • pp.660-670
    • /
    • 2005
  • Standard procedure for development of food list was established based on food intake data of 2001 National Health and Nutrition Survey and 2002 Seasonal Nutrition Survey for Total Diet Study. Foods were sorted in descending order of mean intake, and 54 items within cumulative percentage of 80 were selected, followed by selection of 16 additional items with consumption frequency of 10% or higher. Based on higher consumption in certain seasons, regions, sexes, and age classes, 14 additional items were added. Additional 17 items with probable high contents of heavy metals or 23 items with probable high pesticide residues were added. Altogether, 101 and 107 individual food items were included for heavy metal and pesticide residue lists, accounting for 84.9 and 83.3% mean energy intakes of Korean population, respectively.

Effect of Difference in Irrigation Amount on Growth and Yield of Tomato Plant in Long-term Cultivation of Hydroponics (장기 수경재배에서 급액량의 차이가 토마토 생육과 수량 특성에 미치는 영향)

  • Choi, Gyeong Lee;Lim, Mi Young;Kim, So Hui;Rho, Mi Young
    • Journal of Bio-Environment Control
    • /
    • 제31권4호
    • /
    • pp.444-451
    • /
    • 2022
  • Recently, long-term cultivation is becoming more common with the increase in tomato hydroponics. In hydroponics, it is very important to supply an appropriate nutrient solution considering the nutrient and moisture requirements of crops, in terms of productivity, resource use, and environmental conservation. Since seasonal environmental changes appear severely in long-term cultivation, it is so critical to manage irrigation control considering these changes. Therefore, this study was carried out to investigate the effect of irrigation volume on growth and yield in tomato long-term cultivation using coir substrate. The irrigation volume was adjusted at 4 levels (high, medium high, medium low and low) by different irrigation frequency. Irrigation scheduling (frequency) was controlled based on solar radiation which measured by radiation sensor installed outside the greenhouse and performed whenever accumulated solar radiation energy reached set value. Set value of integrated solar radiation was changed by the growing season. The results revealed that the higher irrigation volume caused the higher drainage rate, which could prevent the EC of drainage from rising excessively. As the cultivation period elapsed, the EC of the drainage increased. And the lower irrigation volume supplied, the more the increase in EC of the drainage. Plant length was shorter in the low irrigation volume treatment compared to the other treatments. But irrigation volume did not affect the number of nodes and fruit clusters. The number of fruit settings was not significantly affected by the irrigation volume in general, but high irrigation volume significantly decreased fruit setting and yield of the 12-15th cluster developed during low temperature period. Blossom-end rot occurred early with a high incidence rate in the low irrigation volume treatment group. The highest weight fruits was obtained from the high irrigation treatment group, while the medium high treatment group had the highest total yield. As a result of the experiment, it could be confirmed the effect of irrigation amount on the nutrient and moisture stabilization in the root zone and yield, in addition to the importance of proper irrigation control when cultivating tomato plants hydroponically using coir substrate. Therefore, it is necessary to continue the research on this topic, as it is judged that the precise irrigation control algorithm based on root zone-information applied to the integrated environmental control system, will contribute to the improvement of crop productivity as well as the development of hydroponics control techniques.

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • 제5권2호
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF

Changes in Biochemical Components of Several Tissues of the Hard Clam, Meretrix petechialis, in Relation to Gonad Developmental Phases (말백합, Meretrix petechialis의 생식소 발달단계에 따른 일부 조직의 생화학적 성분 변화)

  • Kim, Yong-Min;Park, Kwan-Ha;Chung, Ee-Yung;Kim, Jong-Bae;Lee, Chang-Hoon
    • The Korean Journal of Malacology
    • /
    • 제22권2호
    • /
    • pp.125-134
    • /
    • 2006
  • We investigated the reproductive cycle of the hard clam, Meretrix petechialis with its gonadal development by histological observations. The seasonal changes in biochemical component of the adductor muscle, visceral mass, foot muscle and mantle of the clam were studied by biochemical analysis, from January to December, 2002. The reproductive cycle of this species can be divided into five successive stages: early stage (January to March), late active stage (February to May), ripe stage (April to August), partially spawned stage (July to August) and spent/inactive stage (September to January). Total protein content in the visceral mass was over two times higher than that in the adductor muscle. Monthly changes of total protein content in the adductor muscle were not statistically significant (ANOVA, p = 0.071), while the changes in the visceral mass were significant (p < 0.001). Total protein content in visceral mass was higher during the early active, late active, and ripe stages (from January to May), while the lowest in July. Glycogen content in the adductor muscle was higher than that in the visceral mass. Monthly changes in glycogen contents were statistically significant in both adductor muscle (F = 237.2, p < 0.001) and the visceral mass (F = 64.04, p < 0.001). Glycogen content in the adductor muscle was the highest in the ripe stage (April). Its content was lower in the partially spawned and the spent/inactive stages (June-September). Glycogen contents in the visceral mass were relatively lower until the early active stage, while the highest in the late active stage. RNA content was higher in visceral mass than that in the adductor muscle. Monthly changes in RNA contents were significant in both adductor muscle (F = 195.2, p < 0.001) and visceral mass (F = 78.85, p < 0.001). RNA content in the adductor muscle was high in the early active stage (January-February), and then it decreased rapidly in the late active stage (March-April), thereafter, slightly increased during the partially spawned stage (June-July). RNA content in the visceral mass reached a maximum during the ripe stage (May), and then it decreased rapidly during the partially-spawned stage (June-July). There was significant positive correlation in total protein contents between adductor muscle and visceral mass (r = 0.715, p = 0.020). However, there was no correlation between adductor muscle and visceral mass in glycogen (p = 0.550), while a negative correlation was found between the adductor muscle and visceral mass in RNA (p = 0.518) contents. Especially, changes in RNA content showed a negative correlation between the adductor muscle tissue and visceral mass. Therefore, these results suggest that the nutrient content of the adductor muscle, visceral muscle and foot muscle changed in response to gonadal energy needs.

  • PDF