• 제목/요약/키워드: Sealed device

검색결과 40건 처리시간 0.027초

바이오리액터를 이용한 MC3T3-E1 세포의 기계적 자극에 대한 영향 (Effects of Mechanical Stimulation for MC3T3-E1 Cells using Bioreactor)

  • 이인환;박정훈;이승재;조동우;강상순
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1411-1414
    • /
    • 2008
  • It is reported that mechanical stimulation takes a role in improving cell growth in skeletal system. And various research groups have showed that developed bioreactor to stimulate cell-seeded and threedimensional scaffold. In this study, we designed a custom-made bioreactor capable of applying controlled compression to cell-seeded agarose gel. This device consisted of a circulation system and compression system. In circular system, culture chamber was sealed for prohibiting contamination and media solution was circulated by pump. In compression system, mechanical stimuli were controlled by LabVIEW software and mechanical transfer system. Cell-encapsulated agarose gels were cultured for up to 7 days. There were significant differences between the number of cells grown in dynamic cell culture and in static cell culture from 3 days to 7 days.

  • PDF

IC 칩 냉각용 초소형 히트 파이프의 제작 및 성능 평가 (Fabrication and Characteristics Test of Micro Heat Pipe Array for IC Chip Cooling)

  • 박진성;최장현;조형철;조한상;양상식;유재석
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권7호
    • /
    • pp.351-363
    • /
    • 2001
  • This paper presents an experimental investigation on the heat trensfer characteristic of micro pipe (MHP) array with 38 triangular microgrooves. A heat pipe is an effective heat exchanger operating without external power. The heat pipe transfers heat by means of the latent heat of vaporization and two-phase fluid flow driven by the capillary force. The overall size of the MHP array can be put undermeath a microelectonic die and integrated into the electrronic package of a microelectronin device to dissipate the heat from the die. The MHP array is fabricated by micromachining with a silicon wafer and a glass substrate. The MHP was filled with water and sealed. The experimental results show the temperature decrease of 12.1$^{\circ}C$ at the evaporator section for the input power of 5.9 W and the improvement of 28% in the heat transfer rate.

  • PDF

PDP용 격벽재의 승온 탈가스 특성 (Characteristics of Outgas from Heated Barrier Rib for POP)

  • 김선호;주정훈;이석영;이강욱;오상진
    • 한국표면공학회지
    • /
    • 제37권3호
    • /
    • pp.185-190
    • /
    • 2004
  • Plasma Display Panel is a display device emitting fluorescent light from gas discharge between a front and a rear panel sealed together. Front and rear panel have multitude of film layers and barrier ribs in the rear panel has the largest area so releasing various gases and affecting light emitting characteristics and lifetime. The remaining gases in a barrier rib were studied by thermal desorption analysis up to $400^{\circ}C$ and main gases were $H_2$ $H_2$O, CO. During sustaining at $300^{\circ}C$, the outgassing rates from other gases were decreased but$ H_2$ kept constantly increasing until 1 hour, which can be originated from the dissociation of organics remained in the inside of barrier rib material. In $H_2$O, two distinct peaks were observed: desorption from physically adsorbed one at $l00^{\circ}C$ and from chemically adsorbed one $400^{\circ}C$. The result can be utilized in interpretation of electronic and optical characteristics and evacuation process control of PDP

Biological Monitoring of Human Exposure to Volatile Halogenated Hydrocarbons Using Urinalysis with Capillary GC-ECD

  • Jung, Won-Tae;Sohn, Dong-Hun
    • Archives of Pharmacal Research
    • /
    • 제15권2호
    • /
    • pp.109-114
    • /
    • 1992
  • For the risk assessment of human exposure to volatile halogenated hydrocarbons, a dynamic purge trap/on-column cryofocusing method using capillary gas chromatograph-$^{63}Ni$ electron capture detector and thermal desorption unit was applied to analyze the free forms, metabolites of 1, 1, 2-trichloroethylene and 1, 1, 2, 2-tetrachloroethylene. The urine sample was diluted with distilled water, hydrolyzed and sealed. Then the inert gas was infused to purge out free 1, 1, 2-trichloroethylene, free 1, 1, 2, 2-tetrachloroethylene and urichloroethanol. These compounds were trapped to $Tenax^R$ / GC-gas trap device throughout clean up tube. Being undertectable to gas chromatograph directly, trichloroacetic acid was methyl esterificated and trapped in the manner above mentioned. The optimal incubation time to get best recovery of methyl ester was 4 hours at $60^circ$C. The concentrations of free volatile halogenated hydrocarbons and their metabolites in urine were obtained of free volatile halogenated hydrocarbons and their metabolites in urine were obtained from 5 healthy volunteers. This analytical method is expected to make the biological monitoring more precise and convenient.

  • PDF

T-history법에 의한 잠열량 측정 정확도의 향상 (Accuracy Improvement for Measurement of Heat of Fusion by T-history Method)

  • 박창현;백종현;강채동;홍희기
    • 설비공학논문집
    • /
    • 제15권8호
    • /
    • pp.652-660
    • /
    • 2003
  • T-history method, measuring heat-of-fusion of phase change material (PCM) in sealed tubes, has the advantages of a simple experimental device and no requirements in sampling process. However, a degree of supercooling used in selecting the range of latent heat release and neglecting sensible heat during the phase change process can cause significant errors in determining the heat of fusion in the original method, which has been improved in order to predict better results by us. In the present study, the modified method was applied to a variety of PCM such as paraffin and lauric acid having very small or no supercooling with a satisfactory precision. Also the selection of inflection point and temperature measurement position was fumed out not to affect the accuracy of heat-of-fusion significantly. As a result, the method can provide an appropriate means to assess a new developed PCM by cycle test even if a very accurate value cannot be obtained.

휴대용 XRF 장치의 검출감도 향상에 관한 연구 (Study for Enhancement of the Detection Sensitivity in Hand-Held X-Ray Fluorescence Device)

  • 김성수;이연승;김도윤;고동섭
    • 한국진공학회지
    • /
    • 제20권6호
    • /
    • pp.409-415
    • /
    • 2011
  • 현재 개발 중인 휴대용 XRF (X-Ray Fluorescence) 장치의 검출감도를 향상시키기 위한 방법을 논의하였다. 대기 기체분자에 의한 강도 손실을 최소화하기 위하여 시료와 검출기 사이에 Vacuum module을 설치하였다. Vacuum module은 대기기체 또는 He 기체를 채울 수 있도록 고안하였다. 그리고 Vacuum module 내부에 He 기체를 채운 상태, 또는 진공상태에서 검출감도의 변화를 조사하였다. 그 결과 다음 3가지 중요한 결과를 얻었다. 첫 번째는, 낮은 에너지 영역(3~4 keV)에서의 XRF 강도가 2~4배 정도 증가하였다. 검출감도의 향상은 검출시간의 단축을 의미하기 때문에, 휴대용 XRF 장치에 있어서 매우 중요한 결과이다. 두 번째는, x-ray emission line의 에너지가 3 keV 이하인 원소의 검출 가능성을 확인하였다. 세 번째는, He 기체를 채운 vacuum module을 사용하면, 휴대용 XRF 장치에 진공밀폐용기를 쓰지 않으면서도 대기기체분자에 의한 흡수를 최소화할 수 있다는 것이다. 세 가지 모두 휴대용 XRF 장치의 개발에 있어서 매우 의미있는 결과로 판단된다.

레이저 펄스 에너지를 이용한 무통증 마이크로젯 약물전달시스템 (Painless Microjet Injector Using Laser Pulse Energy)

  • 여재익;한태희;하정무
    • 대한기계학회논문집B
    • /
    • 제35권5호
    • /
    • pp.547-550
    • /
    • 2011
  • 레이저 기반의 무바늘 액체 약물전달장치는 계속해서 개발되어왔다. 레이저 빔이 고무 챔버 내부의 액체에 모이게 된다. 초점이 맞춰진 레이저 빔은 공기방울을 생성시키고 급격히 팽창하게 된다. 밀봉된 챔버 안쪽에서의 급격한 부피변화는 액체약물을 마이크로 노즐을 통해 빠르게 밀어내어 마이크로 약물젯을 생성한다. 노즐의 출구지름은 100 ${\mu}m$ 이하이며 본 연구팀은 생성된 마이크로 약물젯의 속도가 인체의 연조직으로 침투시키기에 충분함을 확인하였다. 이 실험에서는 사람의 혈전을 모사한 무게 비 5%의 젤라틴 수용액을 냉각시킨 샘플과 돼지 지방층을 사용하여 침투실험을 수행하였다.

Scaled SONOSFET를 이용한 NAND형 Flash EEPROM (The NAND Type Flash EEPROM Using the Scaled SONOSFET)

  • 김주연;권준오;김병철;서광열
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 추계학술대회 논문집
    • /
    • pp.145-150
    • /
    • 1998
  • 8$\times$8 bit scaled SONOSFET NAND type flash EEPROM that shows better characteristics on cell density and endurance than NOR type have been designed and its electrical characteristics are verified with computer aided simulation. For the simulation, the spice model parameter was extracted from the sealed down SONOSFET that was fabricated by $1.5mutextrm{m}$ topological design rule. To improve the endurance of the device, the EEPROM design to have modified Fowler-Nordheim tunneling through the whole channel area in Write/Erase operation. As a result, it operates Write/Erase operation at low current, and has been proven Its good endurance. The NAND type flash EEPROM, which has upper limit of V$_{th}$, has the upper limit of V$_{th}$ as 4.5V. It is better than that of floating gate as 4V. And a EEPROM using the SONOSFET without scaling (65$\AA$-l65$\AA$-35$\AA$), was also designed and its characteristics have been compared. It has more possibliity of error from the V$_{th}$ upper limit as 4V, and takes more time for Read operation due to low current. As a consequence, it is proven that scaled down SONOSFET is more pertinent than existing floating gate or SONOSFET without scaling for the NAND type flash EEPROM.EPROM.

  • PDF

Vacuum Packaging and Operating Properties of Micro-Tunneling Sensors

  • Park, H.W.;Lee, D.J.;Son, Y. B.;Park, J.H.;Oh, M. H.;Ju, B. K.
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2000년도 Proceedings of 5th International Joint Symposium on Microeletronics and Packaging
    • /
    • pp.110-110
    • /
    • 2000
  • Cantilever-shaped lateral field emitters were fabricated and their electrical characteristics were tested. As shown in Fig.1, poly-silicon cantilevers were fabricated by the surface micromachining and they were used to the vacuum magnetic field sensors. The tunneling devices were vacuum sealed with the tubeless packaging method, as shown in Fig.2 and Fig.3. The soda-lime glasses were used for better encapsulation, so the sputtered silicon and the glass layers on the soda-lime glasses were bonded together at 1x10$^{-6}$ Torr. The getter was activated after the vacuum sealing fur the stable emissions. The devices were tested outside of the vacuum chamber. Through vacuum packaging, the tunneling sensors can be utilized. Fig.4 shows that the sensor operates with the switching of the magnetic field. When the magnetic field was applied to the device, the anode currents were varied by the Lorentz force. The difference of anode currents can be varied with the strength of the applied magnetic field.

  • PDF

복제 공격 저항성을 갖는 전자봉인 보안 모델 (A Security Model for Duplication Resistant eSeal)

  • 김주해;최은영;이동훈
    • 정보보호학회논문지
    • /
    • 제17권5호
    • /
    • pp.111-116
    • /
    • 2007
  • 전자봉인 장치는 능동형 RFID장치로서, 화물 컨테이너의 문에 설치되어 컨테이너가 허가받지 않은 자에 의해 개봉되지 않았다는 것을 보증해 주는 장치이다. 전자 봉인장치는 RFID를 이용하므로 도청이나 위조를 막아야만 한다. 또한 보안 프로토콜을 사용하는 전자봉인 장치는 복제가 불가능해야 한다. 전자봉인의 복제 방지 기능이 제공되지 않는다면, 공격자는 컨테이너의 내용물을 바꾸어 넣은 다음에 복제된 전자봉인으로 재봉인 함으로서 전자봉인이 개봉되었었다는 사실을 숨길 수 있을 것이다. 본 논문에서는 도청과 위조를 방지함과 동시에, 봉인의 복제에 대한 저항성을 갖는 프로토콜을 제안하고자 한다.