• Title/Summary/Keyword: Seal material

Search Result 178, Processing Time 0.034 seconds

STRESS DISTRIBUTION OF PERIODONTALLY INVOLVED TEETH RESTORED WITH VAR10US POSTS -THREE-DIMENSIONAL FINITE ELEMENT STUDY- (치주 지지가 감소된 소구치에서 포스트가 치근 응력 분포에 미치는 영향에 대한 3차원 유한요소법적 연구)

  • Jeong, Hye-Jin;Yoo, Jae-Heung;Oh, Nam-Sik;Kim, Han-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.567-578
    • /
    • 2007
  • Statement of problem: The endodontically treated tooth is generally restored with post and core, owing to the brittle and the loss of large amount of tooth structure. As periodontal treatment was developed, there are many cases that periodontally involved teeth used in prosthetic treatment. Purpose: The purpose of this study was to analyze the stress distribution in the dentin and post structures by the various post materials and the amount of remaining alveolar bone height. Material and method: The 3-dimensional finite element models of mandible 1st premolars were divided into six types according to the various amount of remaining alveolar bone and post type. All types were modeled using equal length, diameter and shape of the post. Three types of post and core materials were used: prefabricated titaniumpost and amalgam core, prefabricated stainless steel post and amalgam core, and cast gold post and core. 300 Newton force was applied to functional cusp of mandible 1st premolar. Results: The results were as follows: First, there was no apparent difference in the pattern of stress distribution according to the alveolar bone condition concentrate on the post middle area. Second, there was difference in pattern of stress distribution according to the core materials, gold post and core generated same than amalgam core. Third, there was no apparent difference in the pattern of stress distribution within the dentin according to the post and core materials. But a cast gold post and core generated the lowest maximum stress value, a stainless steel post generated the highest maximum stress value. Fourth, in the reduced alveolar bone model, maximum stress value is 1.5 times than that of the normal alveolar bone model. Conclusion: Within the limitations of this study, to provide minimal stress to the root with alveolar bone reduced, the post length may be as long as apical seal was not destroyed. To prevent fracture of tooth, it is rational to use gold alloy which material was good for stress distribution for post materials.

Efficacy of retreatment NiTi files for root canals filled with calcium silicate-based sealer (칼슘실리케이트 계열 실러로 충전한 근관에서 재치료용 NiTi 파일의 효율성)

  • Jae-Yun, Hyun;Kyung-Mo, Cho;Se-Hee, Park;Yoon, Lee;Yoon-Joo, Lee;Jin-Woo, Kim
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.213-221
    • /
    • 2022
  • Purpose: The efficacy of the amount of sealer in the root canal and two retreatment NiTi file systems in removing filling materials. Materials and Methods: Extracted premolars with a single root canal were selected for this study. After access opening and root canal preparation up to size #40/.06, the specimens were randomly divided into four groups. Gutta percha (GP) tapers of .06 or .04 were used for each group and filled using a single-cone filling technique with CeraSeal, a calcium silicate-based sealer. Each group was retreated either using the ProTaper Universal Retreatment System (PTUR) or the Hyflex Remover (HR). The time taken to remove the filling material, the amounts of apically extruded debris, and canal cleanliness were measured and compared. Results: The amount of sealer did not affect the efficiency when removing the filling materials. However, the filling material was removed faster in the HR group than in the PTUR group. Two types of NiTi files showed similar retreatment effects in the amounts of apically extruded debris and in the degree of canal cleanliness. Conclusion: The amount of sealer in canal filling had no significant effect on retreatability. Retreatment with HR removed filling materials is faster than PTUR. There was no difference in other removal efficiencies according to the type of retreatment NiTi file.

A COMPARATIVE STUDY ON RADIOPACITY OF CANAL FILLING AND RETROGRADE ROOT-END FILLING MATERIALS (근관 충전재 및 치근단 역충전재의 방사선 불투과성에 관한 비교 연구)

  • Kim, Yong-Sang;Kim, Seo-Kyong;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.107-114
    • /
    • 2008
  • This study was performed to assess the radiopacity of a variety of canal filling and retrograde root-end filling materials according to the specification concerning root canal obturation materials. Ten materials including Gutta-percha pellets, amalgam, Fuji II LC, $Dyract^{(R)}$ AP, Super $EBA^{(R)}$, $IRM^{(R)}$, AH $26^{(R)}$, $Sealapex^{TM}$, Tubli-$Seal^{TM}$, and dentin were evaluated in this study. In the first part, densitometric reading of an each step of aluminum step wedge on occlusal film were performed at 60 kVp (0.2, 0.3, 0.4 s), 70 kVp (0.2, 0.3, 0.33 s) to decide appropriate voltage and exposure time. In the second part, ten specimens which are 5 mm in diameter and 0.5, 1.0, 1.5, 2.0, 2.5, 3.0 mm in thickness, were fabricated from each material studied. The specimens were radiographed simultaneously with an aluminum step wedge under decided condition (60 kVp, 0.2 s). The mean radiographic density values of the materials were transformed into radiopacity expressed equivalent thickness of aluminum (mm Al). The following results were obtained. 1. Among the various conditions including 0.2 s, 0.3 s, 0.4 s at 60 kVp and 0.2 s, 0.3 s, 0.33 s at 70 kVp, the appropriate voltage and exposure time that meet the requirement of density from 0.5 to 2.0 was 0.2 s at 60 kVp. 2. All of the materials in this study had greater radiopacity than the minimun level recommended by ISO No. 4049 standards. 3. Most of the materials had greater radiopacity than 3 mm Al requirement of ANSI/ADA specification No. 57 (2000) and ISO No. 6876 (2001) standards except for Fuji II LC and Dyract. It suggests that all experimental canal filling and retrograde root-end filling materials have a sufficient radiopacity that meet the requirement concerning root canal obturation materials except for Fuji II LC and Dyract.

The Study on the Costume of Parhae through the Exchange for Tang and Ancient Japan - focused on the Exchanged Items- (대당$\cdot$대일본과의 교류관계를 통해 본 발해의 복식문화 연구 - 교류시 품목을 중심으로 -)

  • Jeon Hyun-Sil;Kang Soon-Che
    • Journal of the Korean Society of Costume
    • /
    • v.55 no.4 s.94
    • /
    • pp.38-48
    • /
    • 2005
  • This study is consider·ed about the relation or costume among Parhae, ancient Japan and Tang and the culture of this time commonly was influenced by Tang;s culture. The recorded items, which were exchanged from Parhae to Tang and ancient Japan, are the pelt of marten, seal, bear and tiger skin or Ammowhaha(암모화) Gu(구) and so on. Other items from Tang and ancient Japan to Parhae are various clothes and material like silk and so on. This Parhae's clothes made with leather obtained through hunting were the main product of Parhae and had been greatly famous in Tang and ancient Japan. At that time, Tang and ancient Japan had been only dependent on the agricultural life but had not been accustomed to the hunting life, and thereupon, the people in Tang and Nara Era had difficulties to get leather clothes. Accordingly, the leather products stood for the rich, and the people who purchased the leather products from Parhae were recognized as the rich. On the other hand, The prince and the royal family in Parhae were dispatched to Tang as Sooktwui(숙위). They paid a tribute to Tang and In return for it, Tang gave to Sookwui as well as to Parhae's envoys various items and clothes such as Po(포), belt(대), gold and silver Eodae(어대) and textile like a type of silk. These clothes were considered as the formal uniform like Kwanbok(관복) of Parhae. Specially, the time when Sookwui was sent to Tang rot-responded with the time when Tang gave formal uniform to Parhae's envoys. Therefore, we can confirm that the sending of Sookwui influenced to form uniform system of Parhae. In this exchange relation, there were several duplicated items showed, for example Po(포)-belt(대), Eui set(의일습), Eoeui(어의), Jobok(조복), Go(고). These items in Parhae were appeared in process of exchanging from Tang to Japan and from Tang to Parhae. At that time, the exchanges between Tang and Parhae were frequently active much more than those between Tang and Japan, and the acceptance of the culture from Tang was easier in Parhae than Japan in consideration of the geographical location. Therefore, those clothes could be understood as the items already used in Parhae and affected from Tang. These items in Parhae were appeared in process of exchanging from Tang to Japan and from Japan to Parhae. As a result, it is expected that the costumes, which Parhae took from Japan, are the same as those of Tang.

The Study on the Pressure-Sensitive Adhesion Property of Waste FKM Powder and SBS Modified Asphalt (폐불소고무 분말과 SBS로 개질된 아스팔트의 점착 특성에 관한 연구)

  • Chung, Kyung-Ho;Kang, Min-Kyu;Han, Kyung-A
    • Elastomers and Composites
    • /
    • v.44 no.3
    • /
    • pp.282-289
    • /
    • 2009
  • The pressure-sensitive adhesive(PSA) tapes are widely used as floor-sealing material in Korean constructive industry. However, the general PSA tapes can not seal the apertures completely. This is one of main reasons to cause imperfect finishing. In order to solve the problems, the asphalts were modified by FKM powder and SBS in this study. The physical properties of modified asphalts were examined by measuring the softening point, viscosity, tensile strength and adhesion strength of FKM and SBS modified asphalt. The softening point of SBS modified asphalt was increased greatly due to the formation of network structure in asphalt. Also, the change of adhesion strength of SBS modified asphalt with temperature was not so great comparing to those of pure asphalt and FKM modified asphalt. The best results of pressure-sensitive adhesion could be obtained by the SBS(linear) modified asphalt containing 6 wt.% of linear type SBS.

A STUDY ON MICROLEAKAGE OF SEALED AMALGAM RESTORATION (Sealed amalgam restoration의 미세누출에 관한 연구)

  • Lee, Sang-Heon;Lee, Jae-Cheoun;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.1
    • /
    • pp.54-61
    • /
    • 2000
  • Amalgam, though a widely used dental material, does not bond to the tooth substrate Therefore, retentive preparation of the cavity is necessary. Such amalgam restorations, until corrosion products form and plug the margin, will show significant marginal leakage. Unless this is prevented early on, saliva and bacteria may enter the cavity causing postoperative hypersensitivity, dissolution and collapse of the restoration, discoloration of the margin and secondary caries, leading to shortened life-span of the restoration and pulpal pathosis. Recently, a method of restoration has been introduced whereby tooth material can be preserved, cavity margin can be sealed and preventive treatment of pit and fissure can be administered while retaining all the advantages of conventional amalgam restorations. Such sealed amalgams involve removing the carious lesion without extending the cavity for prevention and using pit and fissure sealants to seal cavity margins and pit and fissures to reduce microleakage. In this study, finishing of the amalgam and sealant application were performed after different intervals following of amalgam restoration to compare the microleakage of sealed and conventional amalgam restorations. Thirty bicuspids were prepared with Class V cavity preparations on the buccal and lingual surfaces. After amalgam placement, they were divided into the following groups and treated accordingly. Group 1 : Polishing after 24 hours Group 2 : Immediate sealant application without polishing Group 3 : No polishing, but sealant applied after thermocycling 500 times After treatment, the samples were thermocycled 500 times between $5^{\circ}C$ and $55^{\circ}C$ with a dwell time of 30 seconds. After thermocycling, the samples were dipped into 1% methylene blue kept in a $37^{\circ}C$ incubator at 100% humidity for 24 hours. The teeth were then embedded in resin and cut bucco-lingually along the tooth axis and observed with a stereomicroscope to determine the degree of microleakage, The following results were obtained : 1. Group 2 showed the least microleakeage, while group 1 showed the greatest. 2. Group 1 showed significantly greater microleakage compared to group 2 (p<0.05). However, no significant differences were found between group 1 and 3(p>0.05). No significant differences in microleakage were also found between cup 2 and 3(p<0.05).

  • PDF

Development of Certification Mark of Food Quality for Children's Favorite Foods Safety Management (어린이 기호식품 품질인증을 위한 인증마크 개발 연구)

  • Cho, Sun-Duk;Lee, Sung-Jin;Yun, Jee-Hye;Kim, Seo-Young;Lee, Eun-Ju;Park, Hye-Kyung;Kim, Myung-Chul;Chung, Kee-Hey;Kim, Gun-Hee
    • Journal of Food Hygiene and Safety
    • /
    • v.23 no.1
    • /
    • pp.31-39
    • /
    • 2008
  • This study was performed to develop children's food quality certification system as part of the children's favorite foods safety management projects. As a component of the research, we developed a quality certification logo to build up brand image which is familiar with children, as well as to offer the right standard and opportunity for food selection. The age level contains elementary graders from 8 to 13. The logo concept was focused on 'Safety', 'Certification, Guidance' and 'Health' in accordance with the vision of the Korea Food and Drug Administration (KFDA), "Safe food, good nutrition and healthy children". The logo name was proposed as "Best Food for Children", "Safety Food for Children" and "Children Good Food", which was decided by public subscription in the KFDA. The 36 tentative plans for a seal were proposed depending on names. We conducted a survey for the 12 logo samples, designed by the name of "Children Good Food", to use as the basic material for the development of logo to convey the meaning of children's food quality certification system effectively. This survey was conducted among 321 elementary graders and 331 parents of elementary graders. We selected the most favorite design through the survey and applied it for products practicality. It is expected that a steady policy may be possible to implement by applying the basis of the children's food project.

Tightness of specimen sealing box in 20 L test chamber to evaluate building materials emitting pollutants (건축자재에서 방출되는 오염물질 평가 시 사용되는 20 L 시험챔버 시편홀더의 기밀성 개선)

  • Shin, Woo Jin;Lee, Chul Won;Kim, Man Goo
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.261-267
    • /
    • 2007
  • The 20 L small chamber test method is to evaluate pollutants such as TVOC, formaldehyde emitted from building materials. This method was only designed to evaluate the surface emission of sample exposed in the chamber. In this method, building materials cut with a fixed standard size are fixed in a sample sealing box. The sample sealing box is put into the 20 L test chamber. This chamber is ventilated at a standard air change rate with purified air for 7 days then the sample from the chamber is collected and analyzed to measure the emission rate of TVOC and formaldehyde. In this method, however, if the sealing box does not guarantee airtightness, accurate evaluation for the building materials can not be achieved due to the pollutants emitted from edge of the sample so called, edge effect. This edge effect can be much greater when evaluating panels such as plywood, flooring due to their surface treatment. In this study, flooring was tested to check airtightness of the sample sealing box with analytic results between 1L and 20 L test chamber. Furniture materials like LPM coated one side surface treatment and MDF coated both sides surface treatment with LPM were tested to identify whether the improvement of the sample sealing box airtightness is possible with the comparison between existing and improved test method that low VOC emission tape was used to seal the sample edge. After 7 days, MDF TVOC emission rate was different according to the existence and nonexistence of tape. The emission rate of the existing test method was $0.009mg/m^2h$ and that of improved test method was $0.003mg/m^2h$. Relative standard deviation for the existing test method was $0.004mg/m^2h$ and relative standard deviation for the improved test method was $0.002mg/m^2h$ when the same sample was analyzed three times. The improved test method in this study using low VOC emission tape was effective and able to reduce the heterogeneous effect of the edge from the sample sealing box.