• 제목/요약/키워드: Scroll Casing

검색결과 20건 처리시간 0.04초

스크롤 케이싱이 없는 터보팬에 관한 연구 (Study on flows by turbofan without scroll casing)

  • 김재원;박진원;오정수;안은영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.590-595
    • /
    • 2004
  • Turbo fan as an air moving device is widely used for its silent characteristics and high efficiency relative to the other centrifugal multi blade impeller. In general, turbo fan is installed with a scroll casing for energy conversion from kinetic one to pressure energy. However, a turbo fan without scroll casing is considered as a present model that is proposed model for compact design of a product In detail, the model has only 4 cutoffs as guiders for 4 separated outlets. Specially, equal distribution of flow rate generated by the model blower is main interest in this investigation. The optimal position of the guider is found by reducing abnormal flows such as reverse flow in each outlet.

  • PDF

회전하는 임펠러를 포함한 스크롤 케이싱 내부 유동장의 전산 해석 (Numerical Simulation of Flows Inside Scroll Casing with Rotating Impeller)

  • 김재원;안은영;박진원
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2004년도 추계 학술대회논문집
    • /
    • pp.65-68
    • /
    • 2004
  • The design procedure for centrifugal blower with high inlet resistance is not presented yet. Overall fluid dynamic performance is estimated for comparison between the case of atmospheric inlet condition and the present model. Detail information between blades is prepared by using a commercial program, SCRYU-Tetra. A centrifugal blower with large inlet pressure is adopted in an air purifier having filtering devices. As the inlet residence increases the flow rate of the system is decreased. In parallel, outlet area of the system affects the performance of the system in the sense of flow balance. Consequently, the flow balance between the inlet and outlet becomes an important parameter for the design of the scroll casing for the centrifugal blower with high inlet pressure.

  • PDF

자동차 HVAC용 Blower Unit 내부 유동장의 PIV 계측 (PIV Measurement of Flow Inside of HVAC Blower Unit)

  • 지호성;김보람;이상준
    • 한국자동차공학회논문집
    • /
    • 제15권5호
    • /
    • pp.165-173
    • /
    • 2007
  • Flow characteristics inside a blower unit of an automotive HVAC module were investigated experimentally using a high-resolution PIV technique. The PIV system consists of a 2-head Nd:YAG laser, a high-resolution CCD camera, optics and a synchronizer. The prototype siroco-fan with forward-curved blades was operated under the same condition of real car. The scroll casing was made transparently for capturing clear flow images. The time-averaged velocity fields were measured in three cross sections. Flow is accelerated with going toward the outer wall of scroll due to centrifugal force and large pressure gradient formed in the region between the fan and the outer casing wall. The presence of the cut-off region and diffusing duct of fan outlet influences largely the flow structure inside the blower unit.

에어컨용 직교류홴 시스템의 성능특성에 대한 기본적 설계변수의 영향에 관한 실험적 연구 (An Experimental Study on the Influences of Some Basic Design Parameters on the Performance Characteristics of the Cross-Flow Fan System in Air-Conditioner)

  • 구형모
    • 대한기계학회논문집B
    • /
    • 제23권6호
    • /
    • pp.695-702
    • /
    • 1999
  • A cross-flow fan which constitutes a fan-duct system with a stabilizer and a scroll-casing is widely used in many air-ventilating and air-conditioning devices. The cross-flow fan system has many design parameters which have crucial influence on the performance and the noise characteristics of the devices, which means many difficulties during the design stage of the devices and the general design guide has not sufficiently established yet. This study presents the experimental results of the parameter investigation of some chosen design parameter values, which are the shapes of the stabilizers, the profiles of the scroll casing part, and the diffusion angles of the flow exit. The results are expressed by the varying performance characteristics with the values of the parameters. They are found to have considerable effects on the system performance and should be considered with care in the design stage. Finally some helpful guides for the design and manufacturing of the cross-flow fan system are proposed.

Crossflow Fan 주변의 유동 (Flows around crossflow fan)

  • 김재원;정윤영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.678-683
    • /
    • 2001
  • The present work has carried out experimental study on a cross-flow fan system with a simplified vortex wall scroll casing. A cross-flow fan test rig was constructed to obtain pressure rise and volume flow rate for various fan operating conditions. The performance estimation is using a wind tunnel with a motor driven damper for flow rate control and flows are quantitatively visualized by light scattering system with a pulsed laser. Min focus on the visualization is finding a eccentric vortex inside a fan which is a major factor reducing fan efficiency. Comprehensive engineering data are prepared for industrial applications and show a good agreement with a prior work by experimental measurements.

  • PDF

직교류 홴의 설계인자가 성능 및 소음 특성에 미치는 영향에 대한 실험적 연구 (An Experimental Study of the Influences of Basic Design Parameters on the Performance and the Noise Characteristics of Cross-flow Fans)

  • 구형모
    • 소음진동
    • /
    • 제10권3호
    • /
    • pp.430-436
    • /
    • 2000
  • The cross-flow fans have been widely used to constitute the air moving systems in many air-ventilating and air-conditioning units. The cross-flow fan system has many design parameters which have crucial influence on the performance and the noise characteristics of the units. As a result there are many difficulties in the design stage of the system and the general design guide has not been sufficiently established yet. This study presents the experimental results of the parametric investigation of some chosen design parameters which are directly related to the shape of the stabilizer the profile of the scroll casing and the diffusion angle of the flow exit. The results are expressed in terms of the fan performance and the specific sound pressure level characteristics. Some parameters have been found to have crucial effects on the system performance/noise characteristics and should be considered with care in the design stage.

  • PDF

토출구의 형상에 따른 원심 송풍기의 성능특성 (Characteristics of Performance for Centrifugal Blower with Different Outlet Geometries)

  • 김재원;김진민;이국도
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.70-77
    • /
    • 2004
  • Comprehensive investigation on the outlet's geometric shapes of a centrifugal blower with higher inlet resistance than an atmospheric pressure is carried out for improvements of its performance. Most unwanted behaviors of such blower are pulsating flows because of unbalance between inflows and outflows in a scroll casing. In order to reduce this undesirable phenomenon a triump is made for both the shape of outlet duct and an accessory structure inserted in the outlet port of the blower. The modification on the shape is concerned with the contraction of cross sectional area and the attached structure is for an intentional obstruction to cause a flow resistance. The details of the modification are examined for different cases and results. The methodologies for the work are performance evaluations including noise level and velocity measurements with PIV Consequently, the performance of improved system is close to that of the system operating with atmospheric pressure at the inlet.

  • PDF

고 흡입저항을 가진 원심 송풍기 (Centrifugal Blower with High Inlet Resistance)

  • 김재원
    • 한국유체기계학회 논문집
    • /
    • 제6권2호
    • /
    • pp.15-22
    • /
    • 2003
  • Comprehensive study on a centrifugal blower for air-purifier involving a few physical filters for percolation process has been accomplished for an optimal design of the air handling system. The filtering media causes a flow resistance for induced flows by a rotating impeller. The present methodology is to adopt PIV system for velocity measurements and wind tunnel connected with an anechoic chamber for total performance test of the blower. Trial prototypes for the blades of a rotor and casing are presented for satisfaction of both flow rate and noise level set by design objectives. Tapered blades with a special casing for a fan show good performance data. The results of velocity fields also explain the reason of improvements of the blower performance.