• 제목/요약/키워드: Screw placement

검색결과 97건 처리시간 0.028초

Posterior C1-2 Stabilization Using Translaminar Screw Fixation of the Axis

  • Hong, Jae-Taek;Lee, Sang-Won;Son, Byung-Chul;Park, Chun-Kun
    • Journal of Korean Neurosurgical Society
    • /
    • 제40권5호
    • /
    • pp.387-390
    • /
    • 2006
  • We report a case of C1-2 instability with a bilateral high-riding transverse foramen that was treated with rod-screw fixation using a technique of translaminar rigid screw fixation of the axis. It is believed that a C1-2 fixation with bilateral C-2 translaminar screws has an important advantage over previously reported techniques of C1-2 fixation by eliminating the risk of injury to the vertebral artery during C2 screw placement.

Mechanical and biological complication rates of the modified lateral-screw-retained implant prosthesis in the posterior region: an alternative to the conventional Implant prosthetic system

  • Lee, Jae-Hong;Lee, Jong-Bin;Kim, Man-Yong;Yoon, Joon-Ho;Choi, Seong-Ho;Kim, Young-Taek
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권2호
    • /
    • pp.150-157
    • /
    • 2016
  • PURPOSE. The modified lateral-screw-retained implant prosthesis (LSP) is designed to combine the advantages of screw- and cement-retained implant prostheses. This retrospective study evaluated the mechanical and biological complication rates of implant-supported single crowns (ISSCs) inserted with the modified LSP in the posterior region, and determined how these complication rates are affected by clinical factors. MATERIALS AND METHODS. Mechanical complications (i.e., lateral screw loosening [LSL], abutment screw loosening, lateral screw fracture, and ceramic fracture) and biological complications (i.e., peri-implant mucositis [PM] and peri-implantitis) were identified from the patients' treatment records, clinical photographs, periapical radiographs, panoramic radiographs, and clinical indices. The correlations between complication rates and the following clinical factors were determined: gender, age, position in the jaw, placement location, functional duration, clinical crown-to-implant length ratio, crown height space, and the use of a submerged or nonsubmerged placement procedure. RESULTS. Mechanical and biological complications were present in 25 of 73 ISSCs with the modified LSP. LSL (n=11) and PM (n=11) were the most common complications. The incidence of mechanical complications was significantly related to gender (P=.018). The other clinical factors were not significantly associated with mechanical and biological complication rates. CONCLUSION. Within the limitations of this study, the incidence of mechanical and biological complications in the posterior region was similar for both modified LSP and conventional implant prosthetic systems. In addition, the modified LSP is amenable to maintenance care, which facilitates the prevention and treatment of mechanical and biological complications.

Unilateral Posterior Atlantoaxial Transarticular Screw Fixation in Patients with Atlantoaxial Instability : Comparison with Bilateral Method

  • Hue, Yun-Hee;Chun, Hyoung-Joon;Yi, Hyeong-Joong;Oh, Seong-Hoon;Oh, Suck-Jun;Ko, Yong
    • Journal of Korean Neurosurgical Society
    • /
    • 제45권3호
    • /
    • pp.164-168
    • /
    • 2009
  • Objective : Bilateral C1-2 transarticular screw fixation (TAF) with interspinous wiring has been the best treatment for atlantoaxial instability (AAI). However, several factors may disturb satisfactory placement of bilateral screws. This study evaluates the usefulness of unilateral TAF when bilateral TAF is not available. Methods : Between January 2003 and December 2007, TAF was performed in 54 patients with AAI. Preoperative studies including cervical x-ray, three dimensional computed tomogram, CT angiogram, and magnetic resonance image were checked. The atlanto-dental interval (ADI) was measured in preoperative period, immediate postoperatively, and postoperative 1, 3 and 6 months. Results : Unilateral TAF was performed in 27 patients (50%). The causes of unilateral TAF were anomalous course of vertebral artery in 20 patients (74%), severe degenerative arthritis in 3 (11%), fracture of C1 in 2, hemangioblastoma in one, and screw malposition in one. The mean ADI in unilateral group was measured as 2.63 mm in immediate postoperatively, 2.61 mm in 1 month, 2.64 mm in 3 months and 2.61 mm in 6 months postoperatively. The mean ADI of bilateral group was also measured as following; 2.76 mm in immediate postoperative, 2.71 mm in 1 month, 2.73 mm in 3 months, 2.73 mm in 6 months postoperatively. Comparison of ADI measurement showed no significant difference in both groups, and moreover fusion rate was 100% in bilateral and 96.3% in unilateral group (p=0.317). Conclusion : Even though bilateral TAF is best option for AAI in biomechanical perspectives, unilateral screw fixation also can be a useful alternative in otherwise dangerous or infeasible cases through bilateral screw placement.

Accuracy of Thoracolumbar Spine K-Wire Placement in Toy, Small and Medium Breed Dogs: Novice Surgeons with 3D Printed Patient-Specific Guide versus an Experienced Surgeon with Freehand Techniques

  • Hwa-Joeng Shin;Hae-Beom Lee;Yoon-Ho Roh
    • 한국임상수의학회지
    • /
    • 제39권6호
    • /
    • pp.294-301
    • /
    • 2022
  • Three-dimensional (3D) printing technique has been widely used for accurate screw and pin placement in orthopedic surgery and neurosurgery. However, there are few reports comparing the accuracy between the patient-specific guides and freehand Kirschner wire (K-wire) placement in toy, small and medium breed dogs. This study aimed to assess the accuracy of 3D printed patient-specific guides (PSGs) in pin insertion in the thoracolumbar vertebrae of toy breed dogs and compare the outcomes between novice and experienced surgeons. The experiment was conducted on the thoracolumbar vertebrae of 21 euthanized toy breed dogs (median weight, 5.95 kg). The optimal insertion angle placement was determined and patient-specific guides for K-wire insertion were designed and 3D printed using computed tomography (CT) and a 3D computer-aided design program of three vertebrae (Thoracic 12-Lumbar 1). K-wire tracts were made by experienced and novice surgeons and compared to assess the accuracy based on postoperative CT. Based on postoperative CT, in the experienced group, 61 out of 63 pins (96.8%) were fully contained inside the vertebral body and lamina, whereas two pins (3.2%) had perforated the vertebral canal (grade 3, 2-4 mm breach). However, all the pins in the novice group were fully contained. The use of 3D printed PSGs for pin insertion in the thoracolumbar region is an accurate and safe alternative to freehand screw placement by novice surgeons in toy, small and medium breed dogs. Operations with 3D printed PSGs allow novice surgeons to achieve better or similar outcomes in accurate placement of pin/screws in vertebrae.

상악동거상술 및 임플란트매식에 의한 상악 구치부 수복에 관한 임상적 연구 (MAXILLARY SINUS ELEVATION PROCEDURES: A Report of Six Cases)

  • 이동한
    • 대한치과보철학회지
    • /
    • 제33권2호
    • /
    • pp.300-316
    • /
    • 1995
  • Methods for restoring the posterior portion of the maxilla with delayed and simultaneous sinus lift, composite graft and placement of TPS cylinder and screw type implants are presented. Sinus grafting is needed because of minimal remaining alveolar bone and supporting posterior maxillary portion, The composite graft material uses a combination of autogeneous bone from tuberosity, dimeneralized freeze dried allogenic bone and hydroxylapatite with saline. Since 1991, feb, 1 sinus graft with delayed implantation of 3 cylinder implants and 5 sinus grafts with simultaneous placement of 4HA coated screw typed, 8 TPS cylinder typed implants have been performed for 6 patients. None of the 15 restored implants have been lost, Temporization of prosthesis was done about 2-5 months before final prosthetic work, None of them shows any severe complication.

  • PDF

임플란트의 위치와 방향이 좋지 않은 증례의 보철 치료 (Prosthodontic treatment for cases with poor implant position and orientation)

  • 노관태
    • 대한치과의사협회지
    • /
    • 제58권9호
    • /
    • pp.583-589
    • /
    • 2020
  • If the implant is planted in the wrong position or direction, it is disadvantageous for stress distribution, and it is easy to cause complications such as screw loosening, abutment fracture, and implant fracture. If the position or orientation of the implant is not good, efforts should be made to minimize the problem through proper implant prosthetic treatment. In this article, the prosthetic method for facilitating future maintenance in cases with poor implant placement or orientation will be presented.

  • PDF

Accuracy Analysis of Iliac Screw Using Freehand Technique in Spinal Surgery : Relation between Screw Breach and Revision Surgery

  • Lee, Subum;Jung, Sang Ku;Keshen, Sam G.;Lewis, Stephen J.;Park, Jin Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권2호
    • /
    • pp.210-217
    • /
    • 2020
  • Objective : To analyze the accuracy of iliac screws using freehand technique performed by the same surgeon. We also analyzed how the breach of iliac screws was related to the clinical symptoms resulting in revision surgery. Methods : From January 2009 to November 2015, 100 patients (193 iliac screws) were analyzed using postoperative computed tomography scans. The breaches were classified based on the superior, inferior, lateral, and medial iliac wall violation by the screw. According to the length of screw extrusion, the classification grades were as follows : grade 1, screw extrusion <1 cm; grade II, 1 cm ≤ screw extrusion <2 cm; grade III, 2 cm ≤ screw extrusion <3 cm; and grade IV, 3 cm ≤ screw extrusion. We also reviewed the revision surgery associated with iliac screw misplacement. Results : Of the 193 inserted screws, 169 were correctly located and 24 were misplaced screws. There were eight grade I, six grade II, six grade III, and four grade IV screw breaches, and 11, 8, 2, and 3 screws violated the medial, lateral, superior, and inferior walls, respectively. Four revision surgeries were performed for the grade III or IV iliac screw breaches in the lateral or inferior direction with respect to its related symptoms. Conclusion : In iliac screw placement, 12.4% breaches developed. Although most breaches were not problematic, symptomatic violations (2.1%) could result in revision surgery. Notably, the surgeon should keep in mind that lateral or inferior wall breaches longer than 2 cm can be risky and should be avoided.

Clinical study on screw loosening in dental implant prostheses: a 6-year retrospective study

  • Lee, Ki-Young;Shin, Kyung Su;Jung, Ji-Hye;Cho, Hye-Won;Kwon, Kyung-Hwan;Kim, Yu-Lee
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제46권2호
    • /
    • pp.133-142
    • /
    • 2020
  • Objectives: In this study, we determined the incidence and pattern of screw loosening in patients who received dental implants. Materials and Methods: Patients who received implants between January 2008 and October 2013 and completed their prosthetic rehabilitation were evaluated for the incidence, frequency, and onset of screw loosening using dental charts and radiographs. The association between each factor and screw loosening was analyzed using the chi-square test and a multivariate analysis with binary logistic regression models (P<0.05). Results: Total 1,928 implants were placed in 837 patients (448 males, 389 females), whose follow-up period after loading varied from 0.25 to 70 months (mean period, 31.5 months). Screw loosening occurred in 7.2% of implants. Most cases occurred less than six months after loading. Among those, 22.3% experienced recurrent screw loosening. Screw loosening was most common in the molar region (8.5%) and frequently associated with an implant diameter of ≥5 mm (14.2%). External implant-abutment connections (8.9%) and screw-retained implant prostheses (10.1%) showed higher incidence of problems than internal implant-abutment connections and cement-retained implants, respectively. Screw loosening was most common in implant prostheses with single crowns (14.0%). Conclusion: Within the limits of the current study, we conclude that the incidence of screw loosening differs significantly according to the position of implant placement, the type of implant and manufacturer, implant diameter, the type of implant-abutment connection, the type of retention in the implant prosthesis, and the type of implant prosthesis.

Free Hand Insertion Technique of S2 Sacral Alar-Iliac Screws for Spino-Pelvic Fixation : Technical Note, Acadaveric Study

  • Park, Jong-Hwa;Hyun, Seung-Jae;Kim, Ki-Jeong;Jahng, Tae-Ahn
    • Journal of Korean Neurosurgical Society
    • /
    • 제58권6호
    • /
    • pp.578-581
    • /
    • 2015
  • A rigid spino-pelvic fixation to anchor long constructs is crucial to maintain the stability of long fusion in spinal deformity surgery. Besides obtaining immediate stability and proper biomechanical strength of constructs, the S2 alar-iliac (S2AI) screws have some more advantages. Four Korean fresh-frozen human cadavers were procured. Free hand S2AI screw placement is performed using anatomic landmarks. The starting point of the S2AI screw is located at the midpoint between the S1 and S2 foramen and 2 mm medial to the lateral sacral crest. Gearshift was advanced from the desired starting point toward the sacro-iliac joint directing approximately $20^{\circ}$ angulation caudally in sagittal plane and $30^{\circ}$ angulation horizontally in the coronal plane connecting the posterior superior iliac spine (PSIS). We made a S2AI screw trajectory through the cancellous channel using the gearshift. We measured caudal angle in the sagittal plane and horizontal angle in the coronal plane. A total of eight S2AI screws were inserted in four cadavers. All screws inserted into the iliac crest were evaluated by C-arm and naked eye examination by two spine surgeons. Among 8 S2AI screws, all screws were accurately placed (100%). The average caudal angle in the sagittal plane was $17.3{\pm}5.4^{\circ}$. The average horizontal angle in the coronal plane connecting the PSIS was $32.0{\pm}1.8^{\circ}$. The placement of S2AI screws using the free hand technique without any radiographic guidance appears to an acceptable method of insertion without more radiation or time consuming.

Accuracy of Freehand versus Navigated Thoracolumbar Pedicle Screw Placement in Patients with Metastatic Tumors of the Spine

  • De La Garza Ramos, Rafael;Echt, Murray;Benton, Joshua A.;Gelfand, Yaroslav;Longo, Michael;Yanamadala, Vijay;Yassari, Reza
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권6호
    • /
    • pp.777-783
    • /
    • 2020
  • Objective : To compare the accuracy and breach rates of freehand (FH) versus navigated (NV) pedicle screws in the thoracic and lumbar spine in patients with metastatic spinal tumors. Methods : A retrospective review of adult patients who underwent pedicle screw fixation in the thoracic or lumbar spine for metastatic spinal tumors between 2012 and 2018 was conducted. Breaches were assessed based on the Gertzbein and Robbins classification and only screws placed >4 mm outside of the pedicle wall (lateral or medial) were considered breached. Results : A total of 62 patients received 547 pedicle screws (average 8 per patient) - 34 patients received 298 pedicle screws in the FH group and 28 patients received 249 screws in the NV group. There were 40/547 breaches, corresponding to a breach and accuracy rate of 7.3% and 92.7%, respectively. The breach rate was 9.7% in the FH group and 4.4% in the NV group (chi-squared test, p=0.017); this corresponded to an accuracy rate of 90.3% and 95.6%, respectively. Only one patient from the overall cohort (in the FH group) required revision surgery due to a medial breach abutting the spinal cord (1.6% of all patients; 2.9% of FH patients); no patient suffered organ, vessel, or neurological injury from screw breaches. Conclusion : Navigated pedicle screw placement in patients with metastatic spinal tumors has a significantly higher radiographic accuracy compared to the FH technique. However, the revision surgery was low and no patient suffered from clinically-relevant breach. Navigation also offers the advantage of real-time localization of spinal tumors and aids in targeting and resection of these lesions.