• Title/Summary/Keyword: Screw

Search Result 2,442, Processing Time 0.034 seconds

Studies on the Effects of Amylase Addition to Rice Extrusion on the Rheological Properties of the Extrudate for Weaning Food Base (압출조리를 이용한 쌀 이유식 제조에서 아밀라제 첨가가 물성변화에 미치는 효과)

  • Lee, Gang-Gweon;Kim, Ji-Yong;Lee, Cherl-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.670-678
    • /
    • 1994
  • The effects of amylase addition during extrusion cooking of rice on the physico-chemical properties of the extrudates were investigated in order to develop rice-based Korean style weaning food products. A laboratory-built single screw extruder was used, the enzymes used were Termamyl 120LS(amylase from Bacillus licheniformis, NOVO Co.), BAN 240L(amylase from Bacillus amylolichuefaciens, NOVO Co.) and malt powder. By the addition of enzymes, the water soluble index of the extrudates increased by 3 times compared to that of the extrudates without enzyme and the concentration of reducing sugar in the extrudates increased drastically at 28 feed moisture. The gel permeation chromatographic pattern showed that the large molecular starch fractions diminished by the addition of enzyme during extrusion and the low molecular fraction increased. The residual enzyme activity in the extrudate were 27% for the most thermo-resistance enzyme by treating at $140^{\circ}C$ in the metering section of the extruder. The sediment volume of the extrudate dispersion increased as the metering section temperature increased to $140^{\circ}C$ . By the addition of enzymes the viscosity of extrudate dispersion was redused $1/4{\sim}1/200$ of that of the extrudates without enzyme. It allowed to use 1.8 times of solid material to the weaning food formulation to attain the same level of consistency as the commercial products. It proves that the addition of amylase during rice extrusion is effective to increase the energy density of weaning food by starch degradation, which results in the increases of water solubility, reducing sugar content, dispersibility and fluidability.

  • PDF

Characteristics of Pelletized Swine Manure Compost (돈분뇨 퇴비의 펠렛가공 효과)

  • Jeong, K.H.;Kim, J.H.;Choi, D.Y.;Park, C.H.;Kwag, J.H.;Yoo, Y.H.;Han, M.S.;Jeong, M.S.;Won, H.H.;Yoon, T.Y.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.3
    • /
    • pp.201-210
    • /
    • 2008
  • Farmers directly spread the livestock manure compost on their arable land as an organic fertilizer. However, there are some difficult problems to solve. first, we are unsure of whether the livestock manure compost can meet the nutritional demand of plant. Second, application of the current powered livestock manure compost to crop land is very difficult work due to heavy weight of compost and its powdered shape. For this reason, this study was carried out to develope high quality pelletized livestock manure compost. In pelletizing process with composted manure, the optimal water content for pelletizing was around 30$\sim$40%. When rice bran was mixed with 5% as a bonding agent on volume basis, the pelletizing effect was remarkably improved. On a dry matter basis, the contents of N and P of manure compost were 1.31%, and 0.58%, respectively. After pelletizing, the contents of compost pelleted were 1.37% and 0.54%, respectively. The same parameters of pelletized compost made by screw type Instrument were 1.37% and 0.53%, respectively. The other hand, N and P content of pelletized compost made by pellet mill type instrument were 1.06% and 0.18%, respectively.

  • PDF

A Study on the Mechanical and Physical Properties of Sawdustboard combined with Plastic Chip (플라스틱칩 결체(結締) 톱밥보드의 기계적(機械的) 및 물리적(物理的) 성질(性質)에 관(關)한 연구(硏究))

  • Lee, Phil-Woo;Suh, Jin-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.44-55
    • /
    • 1987
  • In order to study the effect of sawdustboard combined with plastic chips, 0.5mm($T_1$), 1mm($T_2$), 1.4mm($T_3$) thick nylon fiber. polypropylene rope fiber(RP), and 0.23mm thick moth-proof polypropylene net fiber(NP) were cut into 0.5, 1, 2cm long plastic chips. Thereafter, sawdustboard combined with plastic chips prepared as the above and plastic non-combined sawdustboard(control) were manufactured into 3 types of one-, two-, and three layer with 5 or 10% combination level. By the discussions and results at this study, the significant conclusions of mechanical and physical properties were summarized as follows: 1. The MORs were shown in the order of 3 layer> 2 layer> 1 layer among plastic non-combined boards, and $T_3$ < $T_2$ < $T_1$ < RP (NP(5%) < NP(l0%) among plastic combined boards. In 2cm long plastic chip in 1 layer board, the highest strength through all the composition was recognized. 1 layer board showing the lower strength with 0.5cm plastic chip rendered to the bending strength improvement by 2 or 3 layer board composition. On the other hand, 2 or 3 layer combined with 1, 2cm long polypropylene net fiber chips incurred MOR's conspicuous decrease requiring optimum plastic chip combined level and consideration to combined type. 2. MOE in plastic non-combined 3 layer board exhibited sandwich construction effect by higher resin content application to surface layer in the order of 3layer>1layer>2layer with the highest stiffness of the board combined with polypropylene chip, while nylon chip-combined board had little difference from plastic non-combined board. In relevant to length and layer effect, 3 layer board combined with the 0.5cm long polypropylene net fiber chip in 5% and 10% combined level presented 34-43% and 44-76% stiffness increase against plastic non-combined board(control), respectively. Moreover, in 1 layer board, 30% stiffness increase with 10% against 5% combined level in the 1 and 2cm long polypropylene net fiber chip was obtained. 3. Stress at proportional limit(Spl) showing the fiber relationship (r: 0.81-0.97) between MOR presented in the order of 1 layer<2 layer<3 layer in plastic non-combined board. Correspondingly, combined effect by layer and plastic chip length was similar to MOR's. 4. Differently from previous properties(MOR, MOE, Spl). work to maximum load(Wml) of 2 layer board approached to that of 3 layer board. Conforming the above phenomenon. 2 layer combined with 0.5cm long polypropylene net fiber chip kept the greater work than 1 layer. The polypropylene combined board superior to nylon -and plastic non - combined board seemed to have greater anti - failing capacity. 5. Internal bond strength(IB), in contrast to MOR's tendency. showed in the order of T1

  • PDF

Anterior Cruciate Ligament Double Bundle Reconstruction with Hamstring Tendon Autografts - Technical Notes (자가 슬괵건을 이용한 전방 십자 인대 이준 다발 재건술 - 수술 술기 -)

  • Ahn, Jin-Hwan;Lee, Sang-Hak;Ahn, Hyung-Kwon;Kang, Hong-Jae
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.222-231
    • /
    • 2005
  • Purpose: This article describes a double-bundle ACL reconstruction technique using a five-strand hamstring tendon autograft with conventional anteromedial bundle reconstruction and additional posterolateral bundle reconstruction. Operative technique: For the tibial tunnel, the conventional single tunnel technique is performed and for the femoral tunnel, the double tunnel technique is performed with the anteromedial and posterolateral bundle. After minimal notchplasty, the anteromedial femoral tunnel is prepared with leaving one milimeter of posterior femoral cortex within the over-the-top, which if positioned at the 11-o'clock orientation for the right knee or at the 1-o'clock position for the left knee. The posterolateral femoral tunnel that is located 5 to 7 mm superior to the inner margin of the lateral meniscus anterior horn at $90^{\circ}$ of flexion is prepared with tile outside-in technique using a 4.5 cannulated reamer. The graft material for the double bundle reconstruction is made of the conventional four-strand hamstring autograft in the anteromedial bundle and of a single-strand semitendinosus tendon in the posterolateral bundle. The anteromedial bundle is fixed with using a rigid fix system on the femoral side and the posterolateral bundle is fixed to tie with the miniplate from the outside femur. Then, with the knee in $10^{\circ}\;to\;20^{\circ}$ of flexion, a bioabsorbable screw is simultaneously applied to achieve tibial fixation with tensioning of both bundles. Conclusion: A double bundle reconstruction with five-strand hamstring autograft, which is designed with a favorable conventional anteromedial bundle and an additional posterolateral bundle to restore rotation stability, seems to be a very effective method for the treatment for ACL instabilities.

  • PDF

New Technique for the Reconstruction of Both Anteromedial & Posterolateral Bundles of ACL (전방십자인대의 전내측 다발 및 후외측 다발을 각각 재건하는 새로운 수술 수기)

  • Ha Chul-Won;Awe Soo-Ik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.195-199
    • /
    • 2002
  • This article is to report a new technique for reconstruction of the anteromedial and posterolateral bundles of anterior cruciate ligament by separate tensioning and fixation of the each bundle. Method : Tibial and femoral tunnels were made with conventional technique of anterior cruciate ligament reconstruction. Tibial tunnel was enlarged $5\~7$ mm in anterior-posterior direction to make oval it in cross section. When preparing the Achilles tendon allograft, bone plug portion was trimmed as the conventional technique. The tendinous portion was trimmed as two separate bundles by dividing the tendinous portion longitudinally, so the graft is shaped like 'Y'. The bone plug portion of allograft was inserted into the femoral tunnel and fixed with absorbable cross pins. Two ligamentous portionss of the distal part of the grafts were tensioned separately at the external orifice. Anteromedial bundle was fastened under maximum tension with the knee flexed 90 degrees by post-tie method. The posterolateral bundle was fixed by the same technique with the knee in full extension. Then, an absorbable interference screw was inserted between the two bundles upto the upper end of the tibial tunnel, to get more initial rigidity of the reconstructed graft as well as to locate the two bundles in more anatomic position.

  • PDF

A Study on the Black Box Design using Collective Intelligence Analysis (집단지성 분석법을 활용한 블랙박스 디자인 개발 연구)

  • Lee, Hee young;Hong, Jeong Pyo;Cho, Kwang Soo
    • Science of Emotion and Sensibility
    • /
    • v.21 no.2
    • /
    • pp.101-112
    • /
    • 2018
  • This study was carried out to enhance the competitiveness of blackbox design for domestic and international companies, based on the explosive growth of the blackbox market due to development of blackbox design for vehicle accident prevention and post-treatment. In the past, the blackbox market has produced products indiscriminately to meet the ever-increasing demand of consumers. Therefore, we thought a new design method was necessary to effectively investigate the needs of rapidly changing consumers. In this study, we aimed to identify the best-selling blackbox to understand the design flow, and the optimum area for a blackbox, considering the uniqueness of associated vehicle. Based on discussion with blackbox design experts, we studied the direction of design and the problems with blackbox use, which were reflected in blackbox development. Through this research, two types of design - leading blackbox (A type) and mass production blackbox (B type) - were proposed for compatibility of the blackbox with the car. The leading type of blackbox was positioned so that it was wrapped with the room mirror hinge before the screw was fastened, in order to achieve an integrated design. Therefore, we designed an integrated form and resolved the placement problem of an adhesive blackbox. To blend, the mass production blackbox implemented material and surface processing in the same way with the car, and adopted the slide structure to automatically turn off the main body power when removing the SDcard, reflecting consumer needs. This study considers evolving consumer needs through a case study and collective intelligence and deals with implementation of the whole design process during mass production. In this study, we aimed to strengthen the competitiveness of the blackbox design based on design method and its realization.

The Study on Physical Properties and Applicability of Material of Polyamide-66/Glass Fiber Blends Composition to the Eyewear Frame (Polyamide-66/Glass fiber 블렌드 조성물의 물리적 특성 및 안경테 소재로써의 적용성에 관한 연구)

  • Son, Jin-Young;Lee, Ji-Eun;Choi, Kyung-Man;Bae, Yu-Hwan;Kim, Ki-Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.365-371
    • /
    • 2013
  • Purpose: In this study, we evaluated the physical and thermal properties of the compositions made by blending glass fiber (GF) of different contents into glass fiber polyamide-66, and investigated if the compositions applying to the glasses frame to replace the TR-90, which is polyamide-12 resin used as an injection-type spectacle frame material. Methods: To investigate the characteristics change of polyamide-66 (PA-66) compositions with the change of the content of glass fibers, we produced a composition of the content by using a twin-screw extruder. The mechanical strength of the composition production was measured and coating properties as well as cutting processability were evaluated. We evaluated the applicability of the glasses frame by comparison the results of new compositions with characterizations of traditional TR. Results: For the results of the characterization of Polyamide-66/GF composition, we found that the higher increase of content of the glass fiber, the less mold shrinkage rate, and the mechanical strength was increased. Tensile strength increased from $498kg/cm^2$ for 0 wt% of the content of the glass fibers to $849kg/cm^2$ for 30 wt% of the content of the glass fibers. As a result of a coating evaluation, the strength of coating was 4B in the GF 5wt% and 5B, which was extremely good coating characteristics, in the over than GF 5 wt%. Conclusions: In case that 30 wt% of the glass fiber was blended, the mechanical strength was greatly improved, the hardness was increased, injection temperature increased due to increase of the viscosity, and the flow mark of the product may occur. The paint coating of PA-66 blended with glass fiber was all excellent. With general evaluating physical properties and workability properties it was determined that around 10 wt% of the content of the glass fibers was possible to apply a spectacle frame.

EFFECT OF NUMBER OF IMPLANTS AND CANTILEVER DESIGN ON STRESS DISTRIBUTION IN THREE-UNIT FIXED PARTIAL DENTURES: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS

  • Park, Ji-Hyun;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.290-297
    • /
    • 2008
  • STATEMENT OF PROBLEM: Implant-supported fixed cantilever prostheses are influenced by various biomechanical factors. The information that shows the effect of implant number and position of cantilever on stress in the supporting bone is limited. PURPOSE: The purpose of this study was to investigate the effect of implant number variation and the effect of 2 different cantilever types on stress distribution in the supporting bone, using 3-dimensional finite element analysis. MATERIAL AND METHODS: A 3-D FE model of a mandibular section of bone with a missing second premolar, first molar, and second molar was developed. $4.1{\times}10$ mm screw-type dental implant was selected. 4.0 mm height solid abutments were fixed over all implant fixtures. Type III gold alloy was selected for implant-supported fixed prostheses. For mesial cantilever test, model 1-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 1-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 1-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with mesial cantilever were simulated. And then, 155N oblique force was applied to the buccal cusp of second premolar. For distal cantilever test, model 2-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 2-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 2-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with distal cantilever were simulated. And then, 206N oblique force was applied to the buccal cusp of second premolar. The implant and superstructure were simulated in finite element software(Pro/Engineer wildfire 2.0). The stress values were observed with the maximum von Mises stresses. RESULTS: Among the models without a cantilever, model 1-1 and 2-1 which had three implants, showed lower stress than model 1-2 and 2-2 which had two implants. Although model 2-1 was applied with 206N, it showed lower stress than model 1-2 which was applied with 155N. In models that implant positions of models were same, the amount of applied occlusal load largely influenced the maximum von Mises stress. Model 1-1, 1-2 and 1-3, which were loaded with 155N, showed less stress than corresponding model 2-1, 2-2 and 2- 3 which were loaded with 206N. For the same number of implants, the existence of a cantilever induced the obvious increase of maximum stress. Model 1-3 and 2-3 which had a cantilever, showed much higher stress than the others which had no cantilever. In all models, the von Mises stresses were concentrated at the cortical bone around the cervical region of the implants. Meanwhile, in model 1-1, 1-2 and 1-3, which were loaded on second premolar position, the first premolar participated in stress distribution. First premolars of model 2-1, 2-2 and 2-3 did not participate in stress distribution. CONCLUSION: 1. The more implants supported, the less stress was induced, regardless of applied occlusal loads. 2. The maximum von Mises stress in the bone of the implant-supported three unit fixed dental prosthesis with a mesial cantilever was 1.38 times that with a central pontic. The maximum von Mises stress in the bone of the implant-supported three-unit fixed dental prosthesis with a distal cantilever was 1.59 times that with a central pontic. 3. A distal cantilever induced larger stress in the bone than a mesial cantilever. 4. A adjacent tooth which contacts implant-supported fixed prosthesis participated in the stress distribution.

Study of the re-osseointegration of implant fixture after mechanical unscrewing (임플란트 고정체의 의원성 동요 후 골 유착 반응에 관한 연구)

  • Jang, Ji-Hoon;Cho, Jin-Hyun;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.209-214
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate whether the re-osseointegration of the implants that had mechanical unscrewing possibly occurred or not. Furthermore, if it happened, the degree of re-osseointegration was evaluated by comparing with previous osseointegration. Materials and methods: The smooth implant (commercial pure titanium 99%) specimens, whose diameter and length was 3.75 mm, 4 mm, respectively were produced. Two implants were inserted into each tibia of 7 New Zealand female white rabbits weighing at least 3.0 kg. The torque removal force for each implant after 6 weeks of implants placement was measured and included in group I. The torque removal forces were assessed after the fixtures were re-screwed to original position and the subjects were allowed to have 4 more weeks for healing and included in group II. One rabbit was sacrificed after first measurement and produced 4 slide specimens in group I, and two rabbits were sacrificed after 2nd measurement, 7 slide specimens, in group II for histomorphologic investigations. All slide specimens were assessed based on the proportion of BIC (bone-implant contact) as well as CBa (Bone area in the cortical passage) value produced by counting the screw threads embedded in the compact bones under the optical microscopic analysis (${\times}20$). Statistical analysis was conducted to evaluate the torque removal force, BIC and CBa between group I and II. Results: As for the torque removal force, the result was $10.8{\pm}3.6$ Ncm for group I and $20.2{\pm}9.7$ Ncm for group II. Furthermore, the torque removal force of group II increased by 98.1% in average compared to group I (P<.05). On the other hand, histomorphologic analysis displayed that there was no statistical significance in BIC and CBa values between group I and the group II (P>.05), and RT/BIC and RT/CBa between group I and group II were statistically significant (P<.05). Conclusion: It is possible to obtain more substantial re-osseointegration within shorter periods than the period needed for the initial osseointegration in case of iatrogenically unscrewed implants.

Internal Fixation of Proximal Humerus Fracture with Polyaxial Angular Stable Locking Compression Plate in Patients Older Than 65 Years (65세 이상의 상완골 근위부 골절 환자에서 다축 각안정 잠김 압박 금속판을 이용한 내고정술)

  • Lee, Ki-Won;Choi, Young-Joon;Ahn, Hyung-Sun;Kim, Chung-Hwan;Hwang, Jae-Kwang;Kang, Jeong-Ho;Choo, Han-Ho;Park, Jun-Seok;Kim, Tae-Kyung
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.25-31
    • /
    • 2012
  • Purpose: The clinical and radiographic outcomes of the internal fixation, which were executed on patients over the age of 65 with proximal humerus fracture by using a polyaxial angular stable locking compression plate (Non-Contact-Bridging proximal humerus plate, Zimmer, Switzerland, NCB), were evaluated. Materials and Methods: Thirty two patients over the age of 65 among the proximal humerus fracture treated with NCB plate, between August 2007 and January 2011, were chosen as the subjects. The average age of patients was 71 years, and the average postoperative follow-up period was 11.5 months. The fractures included 14 two-part and 18 three-part fractures. The clinical results were evaluated, using the visual analog scale (VAS) score and the Constant score. The radiological results were evaluated by time to union and Paavolainen method, which measures the neck shaft angle. Results: At the last follow-up examination, the mean VAS score was 3 points and the mean Constant score was 64.5 points, with bone union achieved after the average of 16.2 weeks following the surgery in all the cases. The mean neck shaft angle was 125.9 and 24 cases had good results, while 8 cases had fair results by Paavolainen method, at the last follow-up. There were 1 case of delayed union and cerclage wire failure, and 3 cases of subacromial impingement. There were no complications, such as loss of reduction, nonunion, screw loosening, or avascular necrosis of the humeral head. Conclusion: Internal fixation, using a NCB plate, was considered to be an effective surgical method in treating proximal humerus fracture in the elderly patients, on whom the fixation of the fracture and maintenance of reduction are difficult.