• Title/Summary/Keyword: Screening ultrasound

Search Result 80, Processing Time 0.022 seconds

Comparison of Cerebral Blood Flow between Patients with Metabolic Syndrome and Normal Group to Evaluate Diagnostic Value of Transcranial Doppler Ultrasound (대사증후군 환자군과 정상군의 뇌혈류 측정 비교를 통한 뇌졸중 위험인자에 대한 TCD의 진단적 가치 고찰)

  • Um, Eun-Jin;Park, Woo-Rham;Kim, Ju-Sung;Lee, Beom-Joon;Na, Byung-Jo
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.14 no.2
    • /
    • pp.85-100
    • /
    • 2010
  • Objectives: The purpose of this study was to evaluate diagnostic value of Transcranial Doppler Ultrasound about risk factor of stroke by comparing blood flow between patients with metabolic syndrome(MS group) and Normal group. Methods: 62 metabolic syndrome patients and 106 healthy adults were selected who had no cerebrovascular diseases, cardiovascular diseases and other systemic diseases. We measured the mean velocity(Vm), peak systolic velocity(Vs) and pulsatility index(PI) of MCA, ACA, PCA, VA, ICA in two groups using TCD. All subjects were divided by gender and age. Results: In comparing Ms group with normal group, Vm in the MCA, ACA, PCA, ICA and Vs in the MCA, ICA were lower in MS group. In all vessels, PI of MS group were higher than that of Normal group. In all vessels, Vm and Vs revealed negative correlation with age and PI revealed positive correlation with age. In 20-39 year olds, there was decrease in the Vs and Vm and increase of PI of MS group in comparison with normal group. There was significant difference in the Vm of PCA, ICA, Vs of MCA, PCA, ICA and PI of MCA, ACA. In 40-59 year olds, Vm in the MCA, ACA, ICA and Vs in the MCA, ACA were lower in MS group. PI in the MCA, ACA, PCA, ICA were higher in MS group. In 60-79 year olds, Vm of MCA, PCA, ICA was decreased in MS group than Normal group with no statistical signification. Vs in the MCA was lower and PI in the PCA was higher in MS group. In male, Vm of PCA and Vs of MCA were lower and PI of MCA, ACA, PCA, ICA were higher in MS group. In female, Vm of MCA, PCA, ICA and Vs of MCA, ICA were lower and PI of ACA, PCA, VA, ICA were higher in MS group. Conclusions: The significant difference in Vm, Vs, PI between MS group and normal group suggests hemodynamic disorder. Screening and prognosing high risk group can be done through TCD and this can be used to prevent stroke. More detailed study will be needed.

Guideliness of the Parameters Using Integrated Test in Down Syndrome Risk Prediction (다운증후군위험도 예측에서 통합선별검사를 이용한 파라미터의 유의성)

  • Lee, Jin-Won;Go, Sung-Jin;Kang, Se-Sik;Kim, Chang-Soo
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.549-555
    • /
    • 2016
  • This study was an evaluation of the significance of each parameter through aimed at pregnant women subjected to screening test(integrated test) in predicting risk of Down syndrome. We retrospectively analysed the correlation of risk of Down's syndrome with Nuchal Translucency(NT) images measured by ultrasound, Pregnancy Associated Plasma Protein A(PAPP-A), alpha-fetoprotein(AFP), unconjugated estriol(uE3), human chorionic gonadotrophin(hCG) and Inhibin A by maternal serum. As a result, a significant correlation with NT, uE3, hCG, Inhibin A is revealed with Down's syndrome risk(P<.001). In ROC analysis, AUC of Inhibin A is analysed as the biggest predictor of Down's syndrome(0.859). And the criterion for cut-off was inhibin A 1.4 MoM(sensitivity 81.8%, specificity 75.9%). In conclusion, Inhibin A was the most useful in parameters to predict Down's syndrome in the integrated test. If we make up for the weakness based on the cut-off value of parameters they will be able to be used as an independent indicator in the risk of Down's syndrome screening.

Assessing the Potential of Thermal Imaging in Recognition of Breast Cancer

  • Zadeh, Hossein Ghayoumi;Haddadnia, Javad;Ahmadinejad, Nasrin;Baghdadi, Mohammad Reza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8619-8623
    • /
    • 2016
  • Background: Breast cancer is a common disorder in women, constituting one of the main causes of death all over the world. The purpose of this study was to determine the diagnostic value of the breast tissue diseases by the help of thermography. Materials and Methods: In this paper, we applied non-contact infrared camera, INFREC R500 for evaluating the capabilities of thermography. The study was conducted on 60 patients suspected of breast disease, who were referred to Imam Khomeini Imaging Center. Information obtained from the questionnaires and clinical examinations along with the obtained diagnostic results from ultrasound images, biopsies and thermography, were analyzed. The results indicated that the use of thermography as well as the asymmetry technique is useful in identifying hypoechoic as well as cystic masses. It should be noted that the patient should not suffer from breast discharge. Results: The accuracy of asymmetry technique identification is respectively 91/89% and 92/30%. Also the accuracy of the exact location of identification is on the 61/53% and 75%. The approach also proved effective in identifying heterogeneous lesions, fibroadenomas, and intraductal masses, but not ISO-echoes and calcified masses. Conclusions: According to the results of the investigation, thermography may be useful in the initial screening and supplementation of diagnostic procedures due to its safety (its non-radiation properties), low cost and the good recognition of breast tissue disease.

Comparison of Effectiveness in Differentiating Benign from Malignant Ovarian Masses between IOTA Simple Rules and Subjective Sonographic Assessment

  • Tongsong, Theera;Tinnangwattana, Dangcheewan;Vichak-ururote, Linlada;Tontivuthikul, Paponrad;Charoenratana, Cholaros;Lerthiranwong, Thitikarn
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.9
    • /
    • pp.4377-4380
    • /
    • 2016
  • Background: To compare diagnostic performance in differentiating benign from malignant ovarian masses between IOTA (the International Ovarian Tumor Analysis) simple rules and subjective sonographic assessment. Materials and Methods: Women scheduled for elective surgery because of ovarian masses were recruited into the study and underwent ultrasound examination within 24 hours of surgery to apply the IOTA simple rules by general gynecologists and to record video clips for subjective assessment by an experienced sonographer. The diagnostic performance of the IOTA rules and subjective assessment for differentiation between benign and malignant masses was compared. The gold standard diagnosis was pathological or operative findings. Results: A total of 150 ovarian masses were covered, comprising 105 (70%) benign and 45 (30%) malignant. Of them, the IOTA simple rules could be applied in 119 (79.3%) and were inconclusive in 31 (20.7%) whereas subjective assessment could be applied in all cases (100%). The sensitivity and the specificity of the IOTA simple rules and subjective assessment were not significantly different, 82.9% vs 86.7% and 94.0% vs 94.3% respectively. The agreement of the two methods in prediction was high with a Kappa index of 0.835. Conclusions: Both techniques had a high diagnostic performance in differentiation between benign and malignant ovarian masses but the IOTA rules had a relatively high rate of inconclusive results. The IOTA rules can be used as an effective screening technique by general gynecologists but when the results are inconclusive they should consult experienced sonographers.

BreastLight Apparatus Performance in Detection of Breast Masses Depends on Mass Size

  • Shiryazdi, Seyed Mostafa;Kargar, Saeed;Taheri-Nasaj, Hossein;Neamatzadeh, Hossein
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.3
    • /
    • pp.1181-1184
    • /
    • 2015
  • Background: Accurate measurement of breast mass size is fundamental for treatment planning. We evaluated performance of BreastLight apparatus in detection breast of masses with this in mind. Materials and Methods: From July 2011 to September 2013, a total of 500 women referred to mammography unit in Yazd, Iran for screening were recruited to this study. Performance of BreastLight in detection breast masses regard their sizeing, measured with clinical breast examination (CBE), mammography and sonography, was assessed. Sonographic and mammography examinations were performed according to breast density among women in two groups of women younger (n=105) and older (n=395) than 30 years. Size correlations were performed using Spearman rho analysis. Differences between mass size as assessed with the different methods (mammography, sonography, and clinical examination) and the BreastLight detection were analyzed using $X^2$-trend test. Results: Performance of the BreastLight in detection of lesions smaller than or equal to 1 cm assessed by CBE, mammography and sonography was 4.4%,7.7% and 12.5% and for masses larger than 4 cm was 65%, 100% and 57.1%, respectively. The performance of BreastLight in detection was significantly increased with larger masses (p<0.001). Conclusions: We conclude that clinical measurement of breast cancer size is as accurate as that from mammography or ultrasound. Accuracy can be improved by the use of a simple formula of both clinical and mammographic measurements.

Review Study on the Measurement Tools of Scoliosis: Mainly on Non-radiological Methods (척추측만증 평가 척도에 관한 문헌 고찰: 비방사선 방법을 중심으로)

  • Kim, Dong-Joo;Choi, Seong-Kyeong;Jo, Hyo-Rim;Ha, Yu-bin;Choi, Sung-Hwan;Park, Seo-Hyun;Lee, Seung Deok;Keum, Dong-Ho;Sung, Won-Suk;Kim, Eun-Jung
    • The Journal of Korean Medicine
    • /
    • v.42 no.1
    • /
    • pp.75-98
    • /
    • 2021
  • Objectives: The purpose of this study is to investigate the characteristics, validity, and reliability of non-radiological assessment tools of scoliosis that have been studied so far. Methods: Electronic databases including Pubmed, Cochrane Library, CNKI, Science On, RISS, OASIS were searched by keywords including 'scoliosis assessment', 'scoliosis screening', 'physical examination', 'functional measurement', 'photography', and 'smartphone'. Results: 32 articles using radiation-free assessments were identified from 1,011 records. The mostly used non-radiological methods were Surface topography, Scoliometer, Ultrasound, Digital Infrared Thermal Imaging, and Photography. The other methods were Gait analysis, 3D depth sensor imaging, and Low intensity electromagnetic scan. Conclusions: It was found that non-radiological assessment tools might reduce the number of radiographs taken in scoliosis patients. To increase the reliability and validity, further research on the measurement tools of scoliosis will be needed.

Cryptococcosis with Mediastinal Lymph Node and Lung Involvement in an Immunocompetent Adolescent: A Case Report (정상 면역체계를 가진 청소년에서 발생한 종격동 림프절과 폐 크립토코쿠스증 1예)

  • Lee, Jiyeon;Cho, Chang-Min;Cho, Hyun-Hae;Park, Heae Surng;Kim, Kyung-Hyo
    • Pediatric Infection and Vaccine
    • /
    • v.28 no.2
    • /
    • pp.124-131
    • /
    • 2021
  • Cryptococcus neoformans is a fungus that primarily causes opportunistic infections in immunocompromised hosts. It can also cause various infections in immunocompetent patients. Pulmonary cryptococcosis involving the lymph node is relatively rare in immunocompetent patients. In this report, a previously healthy 17-year-old girl presented with high-grade fever and persistent cough. Chest X-ray and computed tomography (CT) scan revealed an anterior mediastinal conglomerate mass that expanded to the right supraclavicular area. Ultrasound-guided gun biopsy revealed histological evidence of cryptococcosis. Immunological screening tests did not identify immunodeficiency. She recovered completely with a combination therapy of amphotericin B and flucytosine for 2 weeks, followed by fluconazole for 8 months. The characteristics of cryptococcosis involving the mediastinal lymph node and the lung should be understood, and the possibility of cryptococcosis even in immunocompetent hosts should be considered.

Clinicopathologic Characteristics of Incidentally Discovered Thyroid Carcinomas (갑상선 우연암종의 임상병리적 특성)

  • Chung Woung-Youn;Cheong Jae-Ho;Chang Hang-Seok;Park Cheong-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.16 no.1
    • /
    • pp.64-68
    • /
    • 2000
  • Objectives: With the recent advances and increasing use of imaging techniques in examination of the neck, the incidence of incidentally discovered thyroid carcinoma has been increasing. This study was carried out to evaluate the clinicopathologic characteristics of incidental thyroid carcinomas and to find optimal therapeutic strategies for these lesions. Materials & Methods: From Jan. 1988 to Aug. 1998, 1,053 patients were operated on for thyroid cancer, of whom 127(12.1%) had incidentally discovered thyroid cancers which were identified during routine health checkups(n=40), diagnostic procedures for unrelated medical conditions(n=39) and mass screening for thyroid cancer(n=48). The preoperative diagnosis was obtained by ultrasound-guided FNAB and the extent of surgery was determined based on frozen section examinations, as well as prognostic factors and gross findings at the time of surgery. Results: There were 6 men and 121 women with a mean age of 45.9 years. Histopathological diagnosis included papillary carcinomas(n=1l9), follicular carcinomas(n=6), poorly differentiated carcinoma(n=l) and medullary carcinoma(n=1). Thirty patients(23.6%) had multifocallesions. The mean diameter of the tumors was 1.1 cm(0.2-3.4 cm). Capsular invasions were found in 53 patients(41.7%) and nodal metastases in 41(32.3%). The surgical procedures used were: 90 less-than total thyroidectomies and 37 total thyroidectomies with central neck node dissection. Lateral neck dissection was added in 5 patients. According to TNM staging, 79 patients(63.2%) were at stage I, 15(12.0%) at stage II, 31(24.8%) at stage III and 0(0.0%) at stage IV. By AMES scoring system, 102 patients(81.6%) were in the low-risk group and 23(18.4%) in the high-risk group. And by MACIS scoring system, 103(86.6%) of 119 papillary thyroid cancer patients were less than 6. Conclusions: The clinicopathological characteristics of incidentally discovered thyroid carcinomas are similar to ordinary thyroid carcinomas. The treatment of choice should be individualized based on the particular clinical situation encountered, as in ordinary thyroid carcinomas.

  • PDF

Risk Analysis of Factors for Metabolic Diseases according to the Epicaridal Adipose Tissue Thickness - which Focused on the Presented Subjects with Asymptomatic Screening Purposes (심장외막의 지방두께에 따른 대사질환의 위험도 분석 - 무증상의 검진목적으로 내원한 대상자를 위주로)

  • Kim, Sun-Hwa;Kim, Jung-Hoon;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.7
    • /
    • pp.476-483
    • /
    • 2016
  • Epicardial adipose tissue(EAT) is metabolically active endocrine organ that secretes several hormones in fat thickness is a risk factor for cardiovascular disease and metabolic disorders. This study was to measure and then using ultrasound epicardial adipose tissue thickness, abdominal subcutaneous fat thickness in the target group correlates and general blood properties and characteristics, and presents a local thickness for prediction of metabolic disorders. Results epicardal adipose tissue of the average thickness measured in each of the subjects was 8.890mm, 4.783mm, 4.777, 6.147mm in each section. Showed the epicardial adipose tissue in correlation with the average thickness of the risk factors age, BMI, SBP, LDH, LDL, TC is a positive correlation relationship(p<0.05) in each section. In particular, the thickness of the metabolic disorders epicardial adipose tissue thickness, abdominal subcutaneous compared to subjects that do not have the risk subjects with a risk factor for fat significantly higher(p<0.05). It showed the most reliable that can be cut-off value of 8.950mm obtained with 66.7 % sensitivity and 80 % specificity for predicting the risk of metabolic disorders.

Prenatal diagnosis of a de novo ring chromosome 11

  • Park, Ju-Yeon;Lee, Moon-Hee;Lee, Bom-Yi;Lee, Yeon-Woo;Ryu, Hyun-Mee;Park, So-Yeon
    • Journal of Genetic Medicine
    • /
    • v.4 no.1
    • /
    • pp.80-83
    • /
    • 2007
  • A 36-year-old pregnant woman was referred for amniocentesis at 19.5 weeks gestation because of advanced maternal age and evidence of increased risk for Edward syndrome in the maternal serum screening test. Cytogenetic analysis of the cultured amniotic fluid cells revealed mosaicism for ring chromosome 11: 46,XX,r(11)[65]/ 45,XX,-11[16]/ 46,XX [34]. Parental karyotypes were normal. A targeted ultrasound showed intrauterine grow th restriction (IUGR). Cordocentesis was performed to characterize the ring chromosome and to rule out tissue specific mosaicism. Karyotype was confirmed as 46,XX,r(11) (p15.5q24.2)[229]/45,XX,-11[15]. And a few new form of ring w ere detected in this culture. The deletion of subtelomeric regions in the ring chromosome were detected by fluorescent in situ hybridization (FISH). The pregnancy was terminated. The fetal autopsy showed a growth-retarded female fetus with rocker bottom feet. We report a case of prenatally detected a de novo ring chromosome 11.

  • PDF