• Title/Summary/Keyword: Screening Examination

Search Result 594, Processing Time 0.023 seconds

Integrated Rotary Genetic Analysis Microsystem for Influenza A Virus Detection

  • Jung, Jae Hwan;Park, Byung Hyun;Choi, Seok Jin;Seo, Tae Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.88-89
    • /
    • 2013
  • A variety of influenza A viruses from animal hosts are continuously prevalent throughout the world which cause human epidemics resulting millions of human infections and enormous industrial and economic damages. Thus, early diagnosis of such pathogen is of paramount importance for biomedical examination and public healthcare screening. To approach this issue, here we propose a fully integrated Rotary genetic analysis system, called Rotary Genetic Analyzer, for on-site detection of influenza A viruses with high speed. The Rotary Genetic Analyzer is made up of four parts including a disposable microchip, a servo motor for precise and high rate spinning of the chip, thermal blocks for temperature control, and a miniaturized optical fluorescence detector as shown Fig. 1. A thermal block made from duralumin is integrated with a film heater at the bottom and a resistance temperature detector (RTD) in the middle. For the efficient performance of RT-PCR, three thermal blocks are placed on the Rotary stage and the temperature of each block is corresponded to the thermal cycling, namely $95^{\circ}C$ (denature), $58^{\circ}C$ (annealing), and $72^{\circ}C$ (extension). Rotary RT-PCR was performed to amplify the target gene which was monitored by an optical fluorescent detector above the extension block. A disposable microdevice (10 cm diameter) consists of a solid-phase extraction based sample pretreatment unit, bead chamber, and 4 ${\mu}L$ of the PCR chamber as shown Fig. 2. The microchip is fabricated using a patterned polycarbonate (PC) sheet with 1 mm thickness and a PC film with 130 ${\mu}m$ thickness, which layers are thermally bonded at $138^{\circ}C$ using acetone vapour. Silicatreated microglass beads with 150~212 ${\mu}L$ diameter are introduced into the sample pretreatment chambers and held in place by weir structure for construction of solid-phase extraction system. Fig. 3 shows strobed images of sequential loading of three samples. Three samples were loaded into the reservoir simultaneously (Fig. 3A), then the influenza A H3N2 viral RNA sample was loaded at 5000 RPM for 10 sec (Fig. 3B). Washing buffer was followed at 5000 RPM for 5 min (Fig. 3C), and angular frequency was decreased to 100 RPM for siphon priming of PCR cocktail to the channel as shown in Figure 3D. Finally the PCR cocktail was loaded to the bead chamber at 2000 RPM for 10 sec, and then RPM was increased up to 5000 RPM for 1 min to obtain the as much as PCR cocktail containing the RNA template (Fig. 3E). In this system, the wastes from RNA samples and washing buffer were transported to the waste chamber, which is fully filled to the chamber with precise optimization. Then, the PCR cocktail was able to transport to the PCR chamber. Fig. 3F shows the final image of the sample pretreatment. PCR cocktail containing RNA template is successfully isolated from waste. To detect the influenza A H3N2 virus, the purified RNA with PCR cocktail in the PCR chamber was amplified by using performed the RNA capture on the proposed microdevice. The fluorescence images were described in Figure 4A at the 0, 40 cycles. The fluorescence signal (40 cycle) was drastically increased confirming the influenza A H3N2 virus. The real-time profiles were successfully obtained using the optical fluorescence detector as shown in Figure 4B. The Rotary PCR and off-chip PCR were compared with same amount of influenza A H3N2 virus. The Ct value of Rotary PCR was smaller than the off-chip PCR without contamination. The whole process of the sample pretreatment and RT-PCR could be accomplished in 30 min on the fully integrated Rotary Genetic Analyzer system. We have demonstrated a fully integrated and portable Rotary Genetic Analyzer for detection of the gene expression of influenza A virus, which has 'Sample-in-answer-out' capability including sample pretreatment, rotary amplification, and optical detection. Target gene amplification was real-time monitored using the integrated Rotary Genetic Analyzer system.

  • PDF

Study of Factors Affecting to Discrepancy between Self-Reported and Body Weight and Height (신장(身長) 및 체중(體重)의 실측치(實測値)와 상용치간(常用値間)의 오차(誤差)에 영향을 미치는 인자(因子))

  • Han, Gu-Wung
    • Journal of Preventive Medicine and Public Health
    • /
    • v.16 no.1
    • /
    • pp.59-65
    • /
    • 1983
  • Screening data from preplacement and periodic examination in Gu Mi Industrial Estate from May, 1983 to June, 1983 provide an opportunity to evaluate the accuracy of self-reported height and weight. The data for men and women were analyzed separated for effects of age, marrital status, educational level, employment status, measured height, measured weight and relative weight (percent of ideal body weight). The mean percent discrepancy from self-reported and measured height was analysed by cross-tubulation, P. value for analysis of variance and multiple correlation analysis in men and women. It is clear from the data that self-reported height and weigt differ from the quantities in systemic ways. But the magnitude of misreporting is very small on average except for weight in women. Whereas height tend to be over-reported, weight is under-reported in women but over-reported in men. Weight was accuracte for age group 20-29 years in men and age group over 40 year in women and over-reporting of weight increased with age in men and under-reporting of weight decreased with age in women. Weight was accurate in 60-64kg group in men and under 50kg group in women and under-stating of weight increased with weight in men and women. Weight was the most accurate in 100-109 percent relative weight group in men and in 90-99 percent relative weight group in women and under-stating of weight increased with relative weight and over-stating decreased with relative weight and over-stating decreased with relative weight in men and women. Height was the most accurate for group of primary school and except group of primary school, accuracy of height increased with educational level in men and women. In height, the highest measured height groups (over than 175cm measured height in men and over than 165cm measured height in women) were the most accurate and of over-reporting of height decreased with measured height. Single variable regression analysis and ANOVAs showed age(P<0.003), measured weight(P<0.0001) relative weight(P<0.0001), educational level(P<0.0005) and employment status(P<0.0007) to be significantly related to ${\Delta}WT$ in women and measured height(P<0.0001), educational level(P<0.03) and marrital status (P<0.03) to be significantly related to ${\Delta}WT$ in men. The women were more sensitive about her body weight than height.

  • PDF

A Study on the Seropositivity of HBsAg among Biennial Health Examinees ; A Nation-wide Multicenter Survey (1998년 한국인 성인에서 혈청 HBsAg 양성률 추정을 위한 조사연구)

  • Kim, Dae-Sung;Kim, Young-Sik;Kim, Jae-Yong;Ahn, Yoon-Ok
    • Journal of Preventive Medicine and Public Health
    • /
    • v.35 no.2
    • /
    • pp.129-135
    • /
    • 2002
  • Objective : The primary objective of this study was to estimate the prevalence of HBsAg-positives in the late 1990's among Korean adults. In addition, we evaluated the association of age, a residential area, a vaccination rate, a family history of chronic liver diseases and a past history of acute liver disease with the seropositivity of HBsAg, and estimated the prevalence of chronic HBV infection by follow-up for 6 month or more. Methods : A total of 10 areas, six metropolitan and four small cities, were selected. In each cities, one health screening center was selected for recruitment of study subjects. The study subjects were enrolled from a general health examination program that is provided by medical insurance companies. Questionnaires on various risk factors were administered to the study subjects. Sera was drawn and tested for HBsAg by radioimmunoassay. HBeAg and ALT were also tested for those of HBsAg positive. The HBsAg positives was retest for HBsAg 6 months later Results : Among the study subjects (n= 1816), the seroprevalence of HBsAg was 5.5% (95% CI=4.5%-6.6%), 7.4% in men (95% CI=5.8-9.4) and 3.6% in women (95% CI=2.5-5.0). A past history of acute liver disease and a family history of chronic liver diseases was shown to be risk factors for HBsAg positivity. Among the 31 HBsAg-positives, negative seroconversion rate was estimated to be 3.2%, Thus, prevalence of chronic HBV infection was estimated to be 5.3% (95% CI=3.7-6.6). Conclusion : In this study, the HBsAg seroprevalence rate was lower than that of the other studies in 1980's, particularly in young adult and women. Considering the public health importance of liver cancer and chronic liver diseases, the further effort is needed to prevent and reduce the HBV infection.

A Study on Oriental Medical Diagnosis of Musculoskeletal Disorders using Moire Image (Moire 영상을 이용한 근골격계 질환의 한의학적 진단에 관한 연구)

  • Lee Eun-Kyoung;Yu Seung-Hyun;Lee Su-Kyung;Kang Sung-Ho;Han Jong-Min;Chong Myong-Soo;Chun Eun-Joo;Song Yung-Sun;Lee Ki-Nam
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.4 no.2
    • /
    • pp.72-92
    • /
    • 2000
  • This research has conducted studies on an Oriental medicine-based method of diagnosing of occupational musculoskeletal system diseases. This researcher has searched through existing relevant medical literature. Also, this researcher has worked on a moire topography using moire topography. In this course, this researcher has reached the following conclusion in relation to the possibility of using a moire topography as a diagnosing device of musculoskeletal system diseases under Oriental medicine . 1 The Western medicine outlines its criteria of screening occupational musculoskeletal system diseases as follows A. The occupational musculoskeletal diseases must clearly include one or more of the subjective symptoms characterized by pain, hypoesthesia dysaesthesia, anaesthesia. etc . B, There should be clinically admitted objective observations and diagnosis outlining that the disease concerned shows symptoms such as tenderness, induration. and edema that can appear with occupational musculoskeletal system diseases. dyscinesia should be admitted with the disease concerned, or there should be observations and diagnosis outlining that abnormality exists in electric muscular or nervous diagnosis and examination . C. It should be admitted that prior to the occurrence of symptoms or observations and diagnosis on musculoskeletal system-related diseases, a patient has been engaged in works with conditions requiring improper work posture or work movement. That is, this is an approach whereby they see abnormality in the musculoskeletal system come from material and structural defect, and adjust and control abnormality in the musculoskeletal system and secreta . 2. The Oriental medicines sees that a patient develops the pain of occupational musculoskeletal diseases as he cannot properly activate the flow of his life force and blood thus not only causing formation of lumps in the body and blocking the flow of life force and blood in some parts of the body. Hence, The Oriental medicine focuses on resolving the cause of weakening the flow of life force and blood, instead of taking material approach of correcting structural abnormality Furthermore , Oriental medicine sees that when muscle tension builds up, this presses blood vessels and nerves passing by, triggering circulation dyscrasia and neurological reaction and thus leading to lesion. Thus, instead of taking skeletal or neurophysiological approach. it seeks to fundamentally resolve the cause of the flow of the life force and blood in muscles not being activated. As a result Oriental medicine attributes the main cause of musculoskeletal system diseases to muscle tension and its build-up that stem from an individual's long formed chronicle habit and work environment. This approach considers not only the social structure aspect including companies owners and work environment that the existing methods have looked at, but also individual workers' responsibility and their environmental factors. Hence, this is a step forward method. 3 The diagnosis of musculoskeletal diseases under Oriental medicine is characterized by the fact that an Oriental medicine doctor uses not only photos taken by himself, but also various detection devices to gather information and pass comprehensive judgment on it. Thus, it is the core of diagnosis under Oriental medicine to develop diagnosing devices matching the characteristics of information to be induced and to interpret information so induced from the views of Oriental medicine. Diagnosis using diagnosing devices values the whole state of a patient and formal abnormality alike, and the whole balance and muscular state of a patient serves as the basis of diagnosis. Hence, this method, instead of depending on the information gathered from devices under Western medicine, requires devices that provide information on the whole state of a patient in addition to the local abnormality information that X-ray. CT, etc., can offer. This method sees muscle as the central part of the abnormality in the musculoskeletal system and thus requires diagnosing devices enabling the muscular state. 4. The diagnosing device using moire topography under Oriental medicine has advantages below and can be used for diagnosing musculoskeletal system diseases with industrial workers . First, the device can Provide information on the body in an unbalanced state. and thus identify the imbalance and difference of height in the left and right stature that a patient can not notice at normal times. Second, the device shows the twisting of muscles or induration regions in a contour map. This is not possible with existing shooting machines such as X-ray, CT, etc., thus differentiating itself from existing machines. Third, this device makes it possible for Oriental medicine to take its unique approach to the abnormality in the musculoskeletal system. Oriental medicine sees the state and imbalance state in muscles as major factors in determining the lesion of musculoskeletal system, and the device makes it possible to shoot the state of muscles in detail. In this respect, the device is significant. Fourth, the device has an advantage as non-aggression diagnosing device.

  • PDF