• Title/Summary/Keyword: Screen mode

Search Result 130, Processing Time 0.031 seconds

A Seismic Analysis for Driving Gear Reducer of ESW Traveling Sea Water Screen (ESW형 해수여과장치의 구동 기어감속기에 대한 내진해석)

  • Kim, Chang-Won;Lee, Young-Shin;Kim, Heung-Tae;Kim, Jee-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.7
    • /
    • pp.599-604
    • /
    • 2012
  • In this study, the safety of the driving gear reducer of ESW(essential service water) traveling sea water screen was evaluated through seismic analysis. Mode analysis of gear reducer was performed for reliability of analysis. Seismic analysis was performed in operating basis earthquake(OBE) and safe shutdown earthquake(SSE), which were applied as design condition using floor response spectrum( FRS). The maximum strain of gear reducer under OBE and SSE were 20.4 ${\mu}$ and 33.6 ${\mu}$, respectively. The maximum stresses were 2.42 MPa under OBE condition and 4.36 MPa under SSE condition, which were smaller than the allowable strength of material.

Seismic Analysis for Driving Gear Reducer of ESW Traveling Sea Water Screen (ESW형 해수여과장치의 구동 기어감속기에 대한 내진해석)

  • Kim, Chang-Won;Lee, Young-Shin;Kim, Heung-Tae;Kim, Jee-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.731-736
    • /
    • 2011
  • In this study, the safety of the driving gear reducer of ESW traveling sea water screen was evaluated through seismic analysis. Mode analysis of gear reducer was performed for reliability of analysis. Seismic analysis was performed in Operating Basis Earthquake(OBE) and Safe Shutdown Earthquake(SSE), which was applied as design condition using Floor Respnse Spectrum(FRS). The maxsimum displacement of gear reducer under OBE and SSE were 0.0137 mm and 0.0241 mm, respectively. The maximum stress of gear reducer under OBE and SSE were 2.42 MPa and 4.36 MPa, respectively.

  • PDF

A Study on the Characteristics of Montage shown in the Spilt Screen - With Focus on Drama '24'- (화면분할 장면에 나타나는 몽타주 특성에 관한 연구 - 미국드라마 '24' 중심으로 -)

  • Kang, Yoon-Hyuck
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2007.11a
    • /
    • pp.698-702
    • /
    • 2007
  • Recently, it isn't hard to find split screen effects in films, TV dramas and commercial films which composes a screen with different frames of images. The TV series '24' which was produced in USA in the year 2001 and is expecting the release of its 7th series next year frequently exhibits such split screen methods. '24' is a TV drama of the events taking place in one day which is produced in the form of real-time mode and consists of 24 episodes which is an hour long. Using split screen method, the drama effectively delivers the events simultaneously taking place at different locations. Moreover, the divided frames of each screen relates to one another by means of collision, synthesis and ect. which captures the vision of the spectators. This study aims at analysing the relationships between the frames which consists split screen scenes in the drama '24' and discover its eye capturing attractions using film montage theories.

  • PDF

Cell Culture Microbioassay for the Water Pollution Monitoring (세포배양 생화학적 기법에 의한 수환경오염 평가)

  • 오승민;정규혁
    • Toxicological Research
    • /
    • v.16 no.4
    • /
    • pp.285-291
    • /
    • 2000
  • So far, investigation of environmental pollution has been achieved in field study. This remains the most exhaustive approach, current dimensions of environmental researches and their inherent complexity require that relatively inexpensive and simple laboratory procedures are developed to make possible the screening of large numbers of sites and samples. At this point. microbioassay has been high-lighted. The purpose of this study is to evaluate the water pollution using microbioassay. Two microbioassay methods were optimized and validated for the sensitive and quantitative determination of total toxic effects in the water. EROD(Ethoxyresorufin-O-deethylase) microbioassay was focused to detect PARs, PCBs and dioxinlike components in the water and E-screen assay to xenoestrogens. The EROD microbioassay was executed in rat hepatoma cell line, H4IIE and E-screen assay in MCF7-BUS cell line. Kumho river was selected for this study. 5ι of river water was extracted using combined solid-phase extraction in static adsorption mode with soxhlet extraction. Pollutants adsorbed to the XAD-4 resin were recovered by elution with ethyl acetate and methylene chloride (1 : 9). Toxic effects of extracts were determined by EROD-microbioassay and E-screen assay. EROD activities of water samples were 7.24-72.24 ng/ι MEQ. The estrogenic effect of various water samples is quantitatively evaluated by EEQ. The EEQ of samples range from 0.05 to 6.07 ng-EEQ/ι. These results suggested that Kumho river was highly polluted with organic toxic chemicals.

  • PDF

Performance Evaluation of Set-top Box Energy Saving using Poisson Process Modeling (포아송 프로세스 모델링을 통한 셋톱박스 에너지 절감 성능 분석)

  • Kim, Yong-Ho;Kim, Hoon
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.10 no.1
    • /
    • pp.33-39
    • /
    • 2011
  • This paper considers a performance analysis of set-top box (STB) power saving schemes. STB converts the signal into content which is then displayed on the television (TV) screen, and there are typically two operation modes: on mode and stand-by mode. The total energy consumption (TEC), a typical measure of power consumption of STB, is defined by the sum of power consumption in each mode. Recently there are some works of STB power saving schemes that transit STB operation modes efficiently, and the mode transition time point of those schemes can be different. Thus it is required to develop a performance evaluation method that reflects mode transition time points of each scheme to get TEC correctly. This paper proposes a performance evaluation method for STB power consumption using Poisson process to consider the mode transition time point. By modeling STB mode transitions as events of Poisson process, the average time duration of STB mode is computed and accordingly the effect of power saving is evaluated. The performance evaluation result shows that the proposed method achieves 1 to 19% improvement in power consumption compared with a conventional performance evaluation method.

  • PDF

Study on Implementation Scheme for Integrated PSD Control System of Seoul Metro (서울메트로 PSD 통합관제시스템 구축방안에 대한 연구)

  • Kim, Yong-Hyeop;Hyun, Yong-Sub;Ryoo, Ho-Joong;Kim, Jin-Su
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1551-1559
    • /
    • 2007
  • Seoul Metro has been constructing the screen doors on the platforms to provide safe and comfort environments. The screen doors of each station are configured so that they can be operated in automatic mode in connection with ATC/ATO through the integrated control panel in the station control room and in manual mode through the control panel of the station control room and crew control panel. These systems have been implemented with different data communication protocols between systems, HMI configuration, and so on due to ordering processes, implementation time and diverse suppliers, and manufactured to be operated within single station. Seoul Metro has been planning to implement the integrated control system to secure seamless train operation and safety and to have a fast response system against emergency situations such as PSD failure and fire, by implementing the system that is able to collectively manage, monitor and control the operation status and equipment conditions of PSD on to the integrated control center. This paper has studied a scheme to reduce the budget for the future facility constructions by standardizing the data format for data communication with the integrated station control panel and using the open standard protocols, in order to secure consistency of operation, system expansion and maintenance with unified and standardized control items.

  • PDF

Fire Risk Assessment for Subway Station According to Supply and Exhaust Conditions (지하철 승강장 급배기 조건에 따른 화재 위험성 평가)

  • Kim, Ha-Young;Rie, Dong-Ho;Kim, Jung-Yup
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.29-34
    • /
    • 2008
  • In this research, to establish the emission for the people who are clearing out, through the numerical analysis using the CFD model, the dangerousness has been investigated in the various emission conditions in a station platform. As a result of research, it is found out that the temperature variation falls between 65.37% and 74.97% to compare without installation of platform screen doors. In the addition, with the supply mode or push-pull mode, the warm current is generated in the platform so the temperature and the layer of smoke are stirred up and felled off. It will make the dangerousness when the people escape. Therefore, when the capacity of emission and the space of platform is set up, the design regards the properties of the fire emission.

A Study on PSD System optimization from manual mode (수동 Mode에서 PSD System 최적화 연구)

  • Son Young-Jin;Min Kyung-Yun;Lee Kang-Won;Bang Yeun-Gun
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.162-167
    • /
    • 2004
  • The ascent and descent market screen door (PSD-Platform Screen Door) between the electromotive car which is in the process of operating from the subway ascent and descent market and the passenger it is an immediacy and crisis as the system which it intercepts currently the inside and outside of the country of course signal system automatic operation signal system (ATO) establishment is operated from the segment. Manual operation signal system (the ATS and the ATC) almost it is a condition which is wholly lacking from the segment. This year from second half of the year 2 line manual operation signal system (ATS). It established the shutting tightly elder brother and the railing elder brother in PSD system in segment 12 reverses and the death accident due to the passenger hurt accident which occurs from the subway. It prevented an energy curtailment in the same time when it raises air cooling efficiency, It gathered it restricted the underground space which is comfortable in the use citizen and and and service it did interface the electromotive car and PSD entrance and exit literature course from the manual operation segment to sleep technically optimizationt. It researched a minute dust diffusion.

  • PDF

A Study on User Preference Test for Development of Guidelines on Standardized Modes (항해장비 표준화모드 지침 개발을 위한 사용자 선호도 조사에 관한 연구)

  • Ahn, Young-Joong;Jeon, Gye-Jeong;Jung, Jae-Hoon;Kang, Nam-Seon
    • Journal of Navigation and Port Research
    • /
    • v.42 no.6
    • /
    • pp.371-377
    • /
    • 2018
  • Navigational equipment standardization mode is a function which is used to standardize key functions, screen display and operation method of major navigation equipment. This is aimed towards to quickly and accurately checking information relevant for safe navigation. Currently, the International Maritime Organization is working on the development of guidelines for the application of navigational equipment in the standardized mode to the task of NCSR Sub-Committee. This study was conducted to investigate users' opinions and preferences in the application of standardization modes and to reflect them in the development of guidelines. In addition, the test program was designed to investigate user preferences for ECDIS among the navigational equipment, such as the types of information and functions that are necessary or preferentially required to perform navigational duties, and the screen configuration. In the study, 333 preference surveys were conducted in 35 countries using a web - based test program. ECDIS users confirmed the content and screen layout of their preferred ECDIS information when conducting navigation duty. The results of the study are significant as they contribute to the development of effective guidelines by presenting user requirements to be considered in the standardization mode.

Quantitative Fire Risk Assesment for the Subway Platform Types (지하철 승강장 형식에 따른 정량적 화재 위험성 평가)

  • Rie, Dong-Ho;Kim, Ha-Young
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.6 s.78
    • /
    • pp.1-6
    • /
    • 2006
  • Subway platform is divided into Side-platform type and Center-platform type. In this study does quantitative fire risk assesment of subway platform types in numerical analysis by using CFD model. From the result of this study, 1) All exhaust mode was low-end result it seems most fire risk at Side-platform station. 2) All exhaust mode was low-end result it seems most fire risk at Center-Platform station. 3) When comparing same type exhaust mode of Side-platform and Center-platform that last thing was visible $9.1{\sim}72.34%$ low-end fire risk. Center-platform is more opera-tive than Side-platform that reduce fire risk when that was same dimension and external environment. Designer look upon a fire characteristic of subway platform types when he make smoke control air volume and platform area design.