• Title/Summary/Keyword: Screen X

Search Result 322, Processing Time 0.026 seconds

Structural Properties of PZT Thick Films Fabricated by the Atmospheric Sintering (분위기 소결한 PZT 후막의 구조적 특성)

  • Lee, Sung-Gap;Shim, Young-Jae;Lee, Young-Hie;Bae, Seon-Gi
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.313-314
    • /
    • 2005
  • $PbTiO_3$ and PZT(52/48) powders, prepared by the sol-gel method, were mixed with an organic vehicle and the PT/PZT(52/40) heterolayered thick films were fabricated by the screen-printing method on Pt/$Al_2O_3$ substrates. The structural properties such as DTA, X-ray diffraction and microstructure, were examined as a amount of the PbO-$PbF_2$ flux. In the X-ray diffraction analysis, PZT(52/48) thick films showed a perovskite polycrystalline structure without a pyrochlore phase.

  • PDF

Fluorescence Characteristics of Gd2O2S:Tb3+ Intensifying Screen According to Increase of Tube Voltage (관전압 증가에 따른 Gd2O2S:Tb3+ 증감지의 형광특성)

  • Je, Jaeyong
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.261-264
    • /
    • 2014
  • In this study, $Gd_2O_2S:Tb^{3+}$ was used as the component of the intensifying screen, and this study aims at analysis of fluorescent feature depending on the increase of tube voltage using spectrometer. When the released fluorescence was measured according to the increase of tube voltage, blue, green and red was observed, among which, $^5D_4-^7F_5$ which is applicable to green, was strongest. In addition, when the fluorescent of 50 kVp and 120 kVp were compared, 50 kVp was proved to release only 9.56% fluorescence of 120 kVp. In case when tube voltage which is higher than 100 kVp is used for the X-ray using $Gd_2O_2S:Tb^{3+}$ intensifying screen, the amount and strength of the fluorescence reaching the film increase drastically, so attention is demanded to get images of proper concentration.

Study on the dark current reduction of $HgI_2$ radiation detector ($HgI_2$ 방사선 검출기의 누설전류 저감에 관한 연구)

  • Shin, Jung-Wook;Kang, Sang-Sik;Kim, Jin-Young;Kim, Kyung-Jin;Park, Sung-Kwang;Jo, Heung-Lae;Lee, Hyung-Won;Nan, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.456-459
    • /
    • 2004
  • Analog film/screen systems have been being changed to a digital x-ray imaging device using direct conversion materials. Photocoductors for a direct detection flat-panel imager require high x-ray absorption, ionization and charge collection, low leakage current and large area deposition. In this work, $HgI_2$ films with excellent properties for x-ray detector were deposited by screen printing method. The thickness of $HgI_2$ film was about $150\;{\mu}m$. The passivation layer is fabricated using a-Se and parlyene, the both fabrication $HgI_2$ film were compared for analyzing the leakage current reduction. We measured electrical properties-leakage current, photosensitivity, SNR though I-V measurement, As the result, $HgI_2$ film using a-Se passivation layer had the greater

  • PDF

Evaluation of Clinical Image on Observational Condition in Mammography (유방촬영시 관찰조건에 따른 임상영상평가)

  • Kim, Mi-Hyun;Kim, Chang-Bok;Ji, Youn-Sang;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.89-95
    • /
    • 2010
  • High contrast and high resolution are the most important factors for examining mammography images. Despite of the inconveniences of screen-film, most clinics still prefer them to computed radiography(CR) and direct radiography(DR). The reading of screen-film mammography images is influenced by the brightness from the X-ray illuminator, the exam room and incoming light from outside sources. Therefore, a comparative analysis on the results of mammo phantom images would be variated by the changes in the reading environment. There was no influence on reading results from the examiners close distance eyesight(p > 0.05); however, reading of micro lesions improved with greater darkness in the X-ray film reading room and the brightness of the X-ray illuminator(p < 0.05). Also, observation of fiber and mass images were maximized at a distance of 50 cm from the reader. Now, it is possible to observe these small classification groups using a magnifying glass without being physically close to the image. For the image of mammography, obtaining high quality images is important but in order to get an accurate clinical lesions of the reading also needs to be considered the optimal environmental factors.

  • PDF

Electrical properties of BST system thick films for microwave devices applications (초고주파 소자로의 응용을 위한 BST계 후막의 전기적 특성에 관한 연구)

  • Lee, Sung-Gap;Park, Choon-Bae;Han, Byoung-Sung;Park, Bok-Kee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.31-34
    • /
    • 2003
  • ($Ba_{0.6-x}Sr_{0.4}Ca_x)TiO_3$ (BSCT) (x=0.10, 0.15, 0.20) powder, prepared by the sol-gel method, were mixed with organic vehicle and the BSCT thick films were fabricated by the screen-printing techniques on alumina substrates using the BSCT paste. The structural and the electrical properties were investigated for various composition ratio and sintering temperature. BSCT thick film thickness, obtained by four printings, was approximately 110 ~ 120 ${\mu}m$. The Curie temperature and dielectric constant at room temperature were decreased with increasing Ca content. The relative dielectric constant, dielectric loss and tunability of the BSCT(50/40/10) specimen, which was sintered at $1420^{\circ}C$ and measured at 1MHz, were about 910, 0.46% and 9.28% at 5kV/cm, respectively.

  • PDF

A Preliminary Study for the Development of Diagnostic X-ray Simulator using Visible Light Source (일반광원을 이용한 진단용 X선 모사 실험장치 개발을 위한 예비 연구)

  • 정광호;서태석;이형구;최보영;윤세철
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.169-175
    • /
    • 2002
  • The purpose of this study is to verify the usefulness of X-ray simulator which uses a visible light source for further study. We developed a small experimental equipment which is composed of three main components - source, localizer and detector. Cartesian coordinate was set in 3D space, and the position of target was assumed the origin of the coordinate. The light from the source passes directly through the target, and projection image is formed on the screen, which can be taken with the digital camera. Since projection images were acquired behind the screen, they were flipped over right and left. By examining the characters of visual light source and equipments, it could be concluded that developed system was useful for experimental purpose.

  • PDF

The study of X-ray detection characteristic and fabrication photoconductor film thickness for Screen printing method (Screen printing method로 제작된 의료용 광도전체 필름의 Tickness의 따른 X선 검출 특성 평가)

  • Lee, Y.K.;Yon, M.S.;KIM, D.H.;Chun, S.L.;Jung, B.D.;Gang, Sang-Sik;Park, J.G.;Mun, C.W.;Nam, S.H.
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.2
    • /
    • pp.11-16
    • /
    • 2009
  • Mercury Iodide as good sensitivity at radiation and has an easy peculiarity that operates at low voltage for other photoconductors(a-Se, a-Si, Ge, etc) Based on this characteristic, we studied about an efficiency of the digital x-ray detector in acccordance with the thickness of photoconductor. To solve the problem that is difficult to make a large area film using PVD(Physical Vapor Deposition)method, we used a PIB(Particle In Binder)method. To make a binder paste, we used a PVB(Polyvinylbutyral) as a binder and a DGME(Diethylene Glycol Monobutyl Ether), DGMEA(Diethylene Glycol Monobutyl Ether Acetate) as a solvent. Using this binder paste, we made a polycrystal mercury iodide film that has an each thickness. To evaluate the electrical properties of this films, we measured a darkcurrent, sensitivity and SNR(Signal to Noise Ratio). Mercury iodide film of the 200um thickness has good electrical properties as a result of the measurement. From this result there is a good chance that replace the existing a-Se(Amnorphous seleinum; a-se) with the mercury iodide.

  • PDF

The Effects of Color Hue-Tone on Recognizing Emotions of Characters in the Film, Les Misérables

  • Kim, Yu-Jin
    • Science of Emotion and Sensibility
    • /
    • v.18 no.1
    • /
    • pp.67-78
    • /
    • 2015
  • This study investigated whether people experience a correspondence between color hue-tone and the main characters' emotions in the 2012 British musical drama film, Les $Mis\grave{e}rables$ through three practical experiments. Six screen images, which represent the characters' different emotions (Parrot's six primary types including love, joy, surprise, anger, sadness, and fear) were selected. For each screen image, participants were asked to judge the degree of the character's dominant emotions evoked from 17 varied screen images, which consisted of original chromatic and achromatized images as well as 15 color-filtered images (5 hues X 3 tones of the IRI color system). These tasks revealed that a chromatic color scheme is more effective to deliver the characters' positive emotions (i.e. love and joy) than an achromatic one. In addition, they proved that the hue and tone dimensions partially influence the relationships between the character emotions and colors.

Structural Properties of PZT(80/20) Thick Films Fabricated by Screen Printing Method

  • Lee, Sung-Gap;Lee, Young-Hie
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.2
    • /
    • pp.35-38
    • /
    • 2005
  • Pb(Zr$_{0.8}$Ti$_{0.2}$)O$_{3}$ powders, prepared by the sol-gel method, were mixed with an organic vehicle and the PZT thick films were fabricated by the screen-printing techniques on Pt/Ah03 substrates. The structural properties were examined as a function of sintering temperature. The particle size distribution of the PZT powder derived from the sol-gel process is uniform with the mean particle size of about 2.6 m. As a result of the DTA, the formation of the polycrystalline perovskite phase was observed at around $890^{circ}$CC. In the X-ray diffraction analysis, all PZT thick films showed a perovskite polycrystalline structure without a pyrochlore phase. The perovskite crystallization temperature of PZT thick films was about $890^{circ}$C. The average thickness of the PZT thick films was approximately 80-90 m.

X-Ray Security Checkpoint System Using Storage Media Detection Method Based on Deep Learning for Information Security

  • Lee, Han-Sung;Kim Kang-San;Kim, Won-Chan;Woo, Tea-Kun;Jung, Se-Hoon
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.10
    • /
    • pp.1433-1447
    • /
    • 2022
  • Recently, as the demand for physical security technology to prevent leakage of technical and business information of companies and public institutions increases, the high tech companies are operating X-ray security checkpoints at building entrances to protect their intellectual property and technology. X-ray security checkpoints are operated to detect cameras and storage media that may store or leak important technologies in the bags of people entering and leaving the building. In this study, we propose an X-ray security checkpoint system that automatically detects a storage medium in an X-ray image using a deep learning based object detection method. The proposed system consists of an edge computing unit and a cloud-computing unit. We employ the RetinaNet for automatic storage media detection in the X-ray security checkpoint images. The proposed approach achieved mAP of 95.92% on private dataset.