• Title/Summary/Keyword: Screen Size

Search Result 625, Processing Time 0.028 seconds

Structural and Dielectric Properties of (Ba,Sr,Ca)$TiO_3$ Thick films Doped with $Dy_{2}O_{3}$ ($Dy_{2}O_{3}$가 첨가된 (Ba,Sr,Ca)$TiO_3$ 후막의 구조 및 유전 특성)

  • Yun, Sang-Eun;Lee, Sung-Gap;Park, Sang-Man;Noh, Hyun-Ji;Lee, Young-Hie;Bae, Seon-Gi
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1275-1276
    • /
    • 2007
  • For fabrication of $BaTiO_3$ system Ferroelectric thick films, (Ba,Sr,Ca)$TiO_3$ (BSCT) powders, prepared by using the alkoxide-based sol-gel method, were doped $MnCO_3$ as acceptor and $Dy_{2}O_{3}$ as donor. $MnCO_3$ and $Dy_{2}O_{3}$-doped (Ba,Sr,Ca)$TiO_3$ thick films were fabricated by screen printing techniques on high purity alumina substrates. The structure and dielectric properties were investigated with variation of $Dy_{2}O_{3}$ amount. As a result of the differential thermal analysis(DTA), exothermic peak was observed at around $670^{\circ}C$ due to the formation of the polycrystalline perovskite phase. All the BSCT thick films, sintered at $1420^{\circ}C$ for 2h, showed the typical XRD patterns of perovskite polycrystalline structure and no pyrochlore phase was observed. The average grain size and thickness of specimens no doped with $Dy_{2}O_{3}$ was 1.32mm, 52mm, respectively. The relative dielectric constant decreased and dielectric loss increased with increasing amount of $Dy_{2}O_{3}$ dopant, the values of the BSCT thick films no doped with $Dy_{2}O_{3}$ were 4043 and 0.4% at 1 kHz, respectively. The relative dielectric constant gradually decreased in the measured frequency range from 0.1 to 100 kHz

  • PDF

A Study on the Image Quality and Patient Dose in Erect Simple Abdomen Radiography (복부 선자세 단순촬영시 화질과 피폭선량에 관한 연구)

  • Kim, Jung-Min;Hayashi, Taro;Ishida, Yuji;Sakurai, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.29-34
    • /
    • 1998
  • The purpose of simple abdomen erect projection is to see the fluid level which indicates gastrointestinal ileus or free air due to perforation. we do not have to insist on low kVp technique in simple abdomen erect position as long as we can detect the fluid level and free air shadow. Therefore, the author tried to decrease patient dose by high kVp technique and to improve the image quality due to motion artifact by reduction of exposure time. [Methods] Experiment 1. * screen/film SRO1000/HRH * exposure factor : $140\;kvp{\pm}5\;kv$ with added filters, 200 mA, 0.01 sec * phantom : Acryles : 15.0 cm(equivalent to 17 cm body thickness) 17.5 cm(equivalent to 21 cm body thickness) 20.0 cm (equivalent to 25 cm body thickness) With the exposure factor for same film density($D=0.8{\pm}0.1$) and with the materials above, we tried to find out entrance skin dose and gonad dose for both male and female. Experiment 2. Burger's phantom radiography were checked to see whether there was any change of image quality according to the kVp and the added filters. Experiment 3. Using rotating meter(self made), we examined the motion artifact and the exposure time limitation. [Results and conculution] 1. Using high voltage technique of 140 kVp with added filter, Skin dose, testicle dose and ovary dose decrease to 89.3%, 47% and 71.4% respectively compare to 70 kVp technique, 2. No great changes of Burger's phantom image has detected as from 70 kVp to 140 kVp and the air hole size of Burger's phantom over 0.028 cc(Diameter 3 mm, hight 4 mm) can be distinghished. 3. 0.01 sec(1 pulse) exposure time is possible in the single phase full wave rectification that why we can quitely reduce the unsharness caused by patient's movement.

  • PDF

Gas Sensing Characteristics of SnO2 Coated with Catalyst for Hydrocarbon Gas (촉매가 첨가된 SnO2 가스센서의 탄화수소 가스에 대한 감응 특성)

  • Lee, Ji-Young;Yu, Il
    • Korean Journal of Materials Research
    • /
    • v.22 no.7
    • /
    • pp.358-361
    • /
    • 2012
  • Co and Ni as catalysts in $SnO_2$ sensors to improve the sensitivity for $CH_4$ gas and $CH_3CH_2CH_3$ gas were coated by a solution reduction method. $SnO_2$ thick films were prepared by a screen-printing method onto $Al_2O_3$ substrates with an electrode. The sensing characteristics were investigated by measuring the electrical resistance of each sensor in a chamber. The structural properties of $SnO_2$ with a rutile structure investigated by XRD showed a (110) dominant $SnO_2$ peak. The particle size of the $SnO_2$:Ni powders with Ni at 6 wt% was about 0.1 ${\mu}m$. The $SnO_2$ particles were found to contain many pores according to a SEM analysis. The sensitivity of $SnO_2$-based sensors was measured for 5 ppm of $CH_4$ gas and $CH_3CH_2CH_3$ gas at room temperature by comparing the resistance in air to that in the target gases. The results showed that the best sensitivity of $SnO_2$:Ni and $SnO_2$:Co sensors for $CH_4$ gas and $CH_3CH_2CH_3$ gas at room temperature was observed in $SnO_2$:Ni sensors coated with 6 wt% Ni. The $SnO_2$:Ni gas sensors showed good selectivity to $CH_4$ gas. The response time and recovery time of the $SnO_2$:Ni gas sensors for the $CH_4$ and $CH_3CH_2CH_3$ gases were 20 seconds and 9 seconds, respectively.

Vegetative Growth and Phylogenetic Relationship of Commercially Cultivated Strains of Pleurotus eryngii based on ITS sequence and RAPD

  • Alam, Nuhu;Shim, Mi-Ja;Lee, Min-Woong;Shin, Pyung-Gyun;Yoo, Young-Bok;Lee, Tae-Soo
    • Mycobiology
    • /
    • v.37 no.4
    • /
    • pp.258-266
    • /
    • 2009
  • Pleurotus eryngii, known as king oyster mushroom has been widely used for nutritional and medicinal purposes. This study was initiated to screen the suitable conditions for mycelial growth and to determine the phylogenetic relationship of the selected strains. Optimal mycelial growth was observed at $30{^{\circ}C}$ and minimum mycelial growth observed at $10{^{\circ}C}$. This mushroom tolerates a broad pH range for mycelial growth, with most favorable growth observed at pH 6. Results also indicated that glucose peptone, yeast malt extract and mushroom complete media were favorable growth media, while Hennerberg and Hoppkins media were unfavorable. Dextrin was the best and xylose the least effective carbon sources. Results revealed that inorganic nitrogen sources were less effective than organic sources for the mycelial growth of P. eryngii. Investigation of genetic diversity is necessary to identify the strains. The ITS region of rDNA were amplified using PCR. The size of the ITS1 and ITS2 regions of rDNA from the different strains varied from 214 to 222 bp and 145 to 236 bp, respectively. The sequence of ITS2 was more variable than that of ITS1, and the 5.8S sequences were identical. A phylogenetic tree based on the ITS region sequences indicated that selected strains could be classified into six clusters. Fourteen IUM and ATCC- 90212 strains were also analyzed by RAPD with 20 arbitrary primers. Fourteen of these primers were efficiently amplified the genomic DNA. The number of amplified bands varied with the primers and strains, with polymorphic fragments in the range from 0.2 to 2.3 kb.

Genetic and molecular analysis of the R-mb gene from maize (옥수수 R-mb 유전자의 유전분석과 그의 구조)

  • 윤필용;유삼규;송원용;윤충효;임용표
    • Korean Journal of Plant Tissue Culture
    • /
    • v.24 no.3
    • /
    • pp.161-165
    • /
    • 1997
  • The R-mb locus of maize is one of several genes that encode tissue-specific transcriptional regulator for the anthocyanin biosynthesis in plant parts and the aleurone layer in seeds. We found that the seed pigment frequencies gradually decreased at selfed progenies of the R-mb genetic stocks. In order to analyze the genomic structure of R-mb locus components, genomic Southern blot was performed by using R specific probe, pR-nj:1. Two bands were detected at the size of about 3.9 and 7.75kb. Five R-mb positive clones (mb-II, III, V,Ⅵ, and Ⅶ) were obtained by screening of maize genomic λFIXII library using R specific probe pR-nj:1. We constructed the restriction map of clone mb-II (7.75Kb positive) and mb-Ⅵ (3.9Kb positive), and have compared these with other R locus genes. From genetic and molecular analysis, it is suggested that R-mb complex consists two copy of R elements, and each element shows the paramutagenic and gene silencing effects by the fashion of cis-inactivation.

  • PDF

Preliminary screening to assess the antimicrobial activities of extracts of evergreen woody species from South Korea against Staphylococcus aureus

  • Jang, Bo Kook;Chi, Lai Won;Cho, Ju Sung;Lee, Cheol Hee
    • Journal of Plant Biotechnology
    • /
    • v.47 no.1
    • /
    • pp.90-99
    • /
    • 2020
  • This study aimed to screen for plants with antimicrobial potential among the evergreen woody species of South Korea that are used for horticulture and landscaping and to provide basic information about plants with proven antimicrobial activity to underpin future research. The plant materials were extracted under various conditions, and the antimicrobial activities of the extracts were evaluated by agar diffusion assay. The screening tests demonstrated that the crude extracts of 43 species had inhibitory effects against S. aureus. The inhibitory activities of four species (Elaeocarpus sylvestris, Camellia japonica, Cleyera japonica, and Quercus salicina) were relatively higher than that of the synthetic antimicrobial agents methylparaben and phenoxyethanol. The highest inhibitory activity was observed with the leaf extracts (extracted with methanol for 30 minutes) of E. sylvestris, based on induction of the largest inhibition zone of 23.3 mm in size. In addition, solvent fractions of E. sylvestris were evaluated. The largest inhibitory zone of 23.1 mm was observed for the n-butanol fraction, which is likely to contain effective compounds that exhibit inhibitory activity against S. aureus. In contrast, n-hexane and residual aqueous fractions showed no antimicrobial activity. Overall, our findings confirm that evergreen woody plants native to South Korea have potential antimicrobial activity.

Commercially Available High-Speed Cameras Connected with a Laryngoscope for Capturing the Laryngeal Images (상용화 된 고속카메라와 후두내시경을 이용한 성대촬영 방법의 소개)

  • Nam, Do-Hyun;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.21 no.2
    • /
    • pp.133-138
    • /
    • 2010
  • Background and Objectives : High-speed imaging can be useful in studies of linguistic and artistic singing styles, and laryngeal examination of patients with voice disorders, particularly in irregular vocal fold vibrations. In this study, we introduce new laryngeal imaging systems which are commercially available high speed cameras connected with a laryngoscope. Materials and Method : The laryngeal images were captured from three different types of cameras. First, the adapter was made to connect with laryngoscope and Casio EX-F1 to capture the images using $2{\times}150$ Watt Halogen light source (EndoSTROB) at speeds of 1,200 tps (frame per second)($336{\times}96$). Second, Phantom Miro ex4 was used to capture the digital laryngeal images using Xenon Nova light source 175 Watt (STORZ) at speeds of 1,920 fps ($512{\times}384$). Finally, laryngeal images were captured using MotionXtra N-4 with 250 Watt halogen lamp (Olympus CLH-250) light source at speeds of 2,000tps ($384{\times}400$) by connecting with laryngoscope. All images were transformed into the Kymograph using KIPS (Kay's image processing Software) of Kay Pentex Inc. Results: Casio EX-F1 was too small to adjust the focus and screen size was diminished once the images were captured despite of high resolution images. High quality of color images could be obtained with Phantom Miro ex4 whereas good black and white images from Motion Xtra N-4 Despite of some limitations of illumination problems, limited recording time capacity, and time consuming procedures in Phantom Miro ex4 and Motion Xtra N-4, those portable devices provided high resolution images. Conclusion : All those high speed cameras could capture the laryngeal images by connecting with laryngoscope. High resolution images were able to be captured at the fixed position under the good lightness. Accordingly, these techniques could be applicable to observe the vocal fold vibration properties in the clinical practice.

  • PDF

Development of multi-dimensional body image scale for malaysian female adolescents

  • Chin, Yit Siew;Taib, Mohd Nasir Mohd;Shariff, Zalilah Mohd;Khor, Geok Lin
    • Nutrition Research and Practice
    • /
    • v.2 no.2
    • /
    • pp.85-92
    • /
    • 2008
  • The present study was conducted to develop a Multi-dimensional Body Image Scale for Malaysian female adolescents. Data were collected among 328 female adolescents from a secondary school in Kuantan district, state of Pahang, Malaysia by using a self-administered questionnaire and anthropometric measurements. The self-administered questionnaire comprised multiple measures of body image, Eating Attitude Test (EAT-26; Gamer & Garfinkel, 1979) and Rosenberg Self-esteem Inventory (Rosenberg, 1965). The 152 items from selected multiple measures of body image were examined through factor analysis and for internal consistency. Correlations between Multi-dimensional Body Image Scale and body mass index (BMI), risk of eating disorders and self-esteem were assessed for construct validity. A seven factor model of a 62-item Multi-dimensional Body Image Scale for Malaysian female adolescents with construct validity and good internal consistency was developed. The scale encompasses 1) preoccupation with thinness and dieting behavior, 2) appearance and body satisfaction, 3) body importance, 4) muscle increasing behavior, 5) extreme dieting behavior, 6) appearance importance, and 7) perception of size and shape dimensions. Besides, a multidimensional body image composite score was proposed to screen negative body image risk in female adolescents. The result found body image was correlated with BMI, risk of eating disorders and self-esteem in female adolescents. In short, the present study supports a multi-dimensional concept for body image and provides a new insight into its multi-dimensionality in Malaysian female adolescents with preliminary validity and reliability of the scale. The Multi-dimensional Body Image Scale can be used to identify female adolescents who are potentially at risk of developing body image disturbance through future intervention programs.

Silicon Nitride Layer Deposited at Low Temperature for Multicrystalline Solar Cell Application

  • Karunagaran, B.;Yoo, J.S.;Kim, D.Y.;Kim, Kyung-Hae;Dhungel, S.K.;Mangalaraj, D.;Yi, Jun-Sin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.276-279
    • /
    • 2004
  • Plasma enhanced chemical vapor deposition (PECVD) of silicon nitride (SiN) is a proven technique for obtaining layers that meet the needs of surface passivation and anti-reflection coating. In addition, the deposition process appears to provoke bulk passivation as well due to diffusion of atomic hydrogen. This bulk passivation is an important advantage of PECVD deposition when compared to the conventional CVD techniques. A further advantage of PECVD is that the process takes place at a relatively low temperature of 300t, keeping the total thermal budget of the cell processing to a minimum. In this work SiN deposition was performed using a horizontal PECVD reactor system consisting of a long horizontal quartz tube that was radiantly heated. Special and long rectangular graphite plates served as both the electrodes to establish the plasma and holders of the wafers. The electrode configuration was designed to provide a uniform plasma environment for each wafer and to ensure the film uniformity. These horizontally oriented graphite electrodes were stacked parallel to one another, side by side, with alternating plates serving as power and ground electrodes for the RF power supply. The plasma was formed in the space between each pair of plates. Also this paper deals with the fabrication of multicrystalline silicon solar cells with PECVD SiN layers combined with high-throughput screen printing and RTP firing. Using this sequence we were able to obtain solar cells with an efficiency of 14% for polished multi crystalline Si wafers of size 125 m square.

  • PDF

A New Small Size Digital Optical Ozone Monitor Using CCD Array as a UV Detector (UV 감지기로서 CCD어레이를 사용한 소형 디지털 광 오존모니터)

  • Chung, Wan-Young;Lee, Seung-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.1
    • /
    • pp.158-163
    • /
    • 2008
  • Ozone monitor based on UV techniques has been widely used due to their signal stability. The high concentration ozone monitor for real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source and a photo multiplier tube as UV detector. The structure could be very useful for low price high concentration ozone monitor and showed good linearity to ozone in the concentration range between 0.05 and 2wt%. For accurate ambient ozone monitoring, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector. The optical signal form the CCD array was converted to digital signal, and the digital signal was displayed on screen using PC interface. The developed system showed good linearity and sensitivity in relatively low measuring range between 10ppm and 10,000ppm, and showed some feasibility of hish resolution ozone monitor using CCD array as a photodetecor.