• Title/Summary/Keyword: Science room

Search Result 4,041, Processing Time 0.024 seconds

A TENTATIVE PLAN ON AN ARRANGEMENT AND A MODEL OF UNIVERSITY LIBRARY BUILDING (대학도서관건립(大學図書館建立)에 있어서 배치(配置)와 모형(模型)에 관(関)한 시안(試案) -특(特)히 "J대학" 제(第) 2 도서관(図書館)을 중심(中心)으로-)

  • Choe, Jung-Tai
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.5 no.1
    • /
    • pp.165-184
    • /
    • 1981
  • This study is concerned with a tentative plan on an arrangement and a model of university library building which is the 2nd (branch) library of J. National University in North Jeonla province. At first, it is necessary to have built new library building for undergraduate student in J. National University. Secondary, I studied on the site problems, a model, size and an arrangement planning in this campus. Finally, at least, to install modernized facilities for this library have to require as follows: 1. General Reading Room 2. Reference Room 3. Basic Reading Room 4. Free Reading Room 5. Reserved Room 6. Periodical Room 7. Seminar and Group Study Room 8. Brousing Room 9. Smoking Room 10. Display Hall.

  • PDF

A Study of Service Improvement for Electronic Information Room by User's Experience (도서관의 전자정보실 서비스 개선을 위한 이용사례 분석)

  • Lee, Kyung-Min
    • Journal of Korean Library and Information Science Society
    • /
    • v.40 no.4
    • /
    • pp.177-198
    • /
    • 2009
  • The domestic libraries offered users computer environment early to adapt in information age. However, the computer environment is generalized today, so it is needed to change about the role of electronic information room in this point. The author investigated use experience by 78 students who are student in library and information science. They experienced electronic information room and wrote their experience. As a result, they felt most inconvenience in information service of librarians, facilities and equipment and space. To improve the service of electronic information room, it is needed to develop the mission and service policy of electronic information room. And also the librarian must think the room as modern reference room that has digital and analog materials and information technology.

  • PDF

A Study on Safety by Risk Assessment of Clean Room (Clean Room 위험성 평가에 따른 안전성 확보에 관한 연구)

  • Song Yun-Suk;Yoon Myong-O;Hyun Seong-Ho;Lee Chang-Woo;Yoon Yo-Song;Kim Sung-Min
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.78-85
    • /
    • 2004
  • This research analyzes Clean Room accidents, and presents research Clean Room, major fire prevention standards of Clean Room (FM, IRI, and NFPA Code), various results from Fire Simulation of analysis. The results are : the smoke diffusion is very quick coupled with the Heating, Ventilating, and Air Conditioning (HVAC) systems under fire ; the possibility of getting the result and the possibility the role of the Sprinkler systems to reduce the diffusion of the smoke. We learn about the importance to stop operating Heating, Ventilating, and Air Conditioning (HVAC) systems and to operate the Sprinkler system for securing safety with fire detection. Therefore, This research will be contributing to secure safety of Clean Room.

Design of Semiconducting Gas Sensors for Room-Temperature Operation

  • Song, Young Geun;Kim, Gwang Su;Ju, Byeong-Kwon;Kang, Chong-Yun
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.1-6
    • /
    • 2020
  • Gas sensors that operate at room temperature have been extensively studied because of sensor stability, lift time, and power consumption. To design effective room-temperature gas sensors, various nanostructures, such as nanoparticles, nanotubes, nanodomes, or nanofibers, are utilized because of their large-surface-to-volume ratio and unique surface properties. In addition, two-dimensional materials, including MoS2, SnS2, WS2, and MoSe, and ultraviolet-activated methods have been studied to develop ideal room-temperature gas sensors. Herein, a brief overview of state-of-the-art research on room-temperature gas sensors and their sensing properties, including nanostructured materials, two-dimensional materials, the ultraviolet-activated method, and ionic-activated gas sensors, is provided.

Analysis of the Bacteria in Nuclear Medicine (핵의학 검사실내 세균 분석)

  • Shin, Seong-Gyu;Lee, Hyo-Yeong
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.2
    • /
    • pp.95-100
    • /
    • 2017
  • In this study, the bacterial contamination level of equipments and devices in the nuclear medicine department of a university hospital was investigated. CNS was detected from the sample collected from the door opening button of the nuclear medicine department. Bacillus sp. was detected from the table and CNS with Bacillus sp. were detected from the control button at the PET-CT room no.1. Also, CNS was detected from the table and the control button at the PET-CT room no.2. In the distribution room no.1, CNS and Bacillus sp. were detected while CNS being detected from the distribution room no.2 and CNS with Bacillus sp. being detected from the distribution room no.3. In the injection room, Enterrococcus faecium and Pontoea sp. were detected. On the table of the ecsomatics room, Pontoea sp. was detected. Bacillus sp. was detected from the inside of the syringe Pb shield and CNS was detected from the outside. Enterrococcus faecium was detected from the Gamma camera table and Bacillus sp. was detected from the door grip. On the chair at the patient waiting room, Pseudomonas aeruginosa abd Bacillus sp. were detected. Therefore, it was understood that infection should be prevented by securely sterilizing examination devices after each examination, maintaining cleanliness by regular sterilization of waiting chairs and such objects with a number of direct contacts with patients, and infection education for the features of nuclear department.

A Design Problem of a Service System with Bi-functional Servers (이중작업능력의 서버로 구성된 서비스시스템 설계)

  • Kim, Sung-Chul
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.32 no.3
    • /
    • pp.17-31
    • /
    • 2007
  • In this paper, we consider a service system with bi-functional servers, which can switch between the primary service room and the secondary room. A service policy is characterized by the switching paints which depend on the queue length in the primary service room and the service level requirement constraint of the secondary room. The primary service room is modeled as a Markovian queueing system and the throughput of the primary service room is function of the total number of bi-functional servers. the buffer capacity of the primary service room, and the service policy. There is a revenue obtained from throughput and costs due to servers and buffers. We study the problem of simuitaneously determining the optimal number of servers, buffer capacity, and service policy to maximize profit of the service system, and develop an algorithm which can be successfully applied with the small number of computations.

Ergonomic consideration of clean room workers (Clean Room 문제점의 인간공학적 연구)

  • ;Ramsey, Jerry D.;Smith, James L.
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1990.04a
    • /
    • pp.163-170
    • /
    • 1990
  • Clean rooms are widely used in high technology industries. Currently within the microelectronics industry there is an explosive growth in the number of clean rooms. Therefore, special consideration of clean room workers is needed to the work induced stresses from contamination avoidance, clothing requirements, and confinements [1].

  • PDF

황색종 잎담배 공동건조장의 환경개선

  • 신승구;백기현;이승철
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.20 no.2
    • /
    • pp.160-165
    • /
    • 1998
  • The Joint curing barns for flue-cured tobacco is a favorite with the tobacco farmers in Korea. However, most of farmer utilizing the joint curing barns indicated many problems such as high temperature and noise in the working room and a dry of cured leaves in the storage room. A structure of Joint curing barns has been modified to meet the needs of tobacco farmers. Compared with the unimproved joint curing barns, the improved one showed that the noise of workshop decreased about 7.7~10.8db, the amount of $CO_2$ decreased 40~50ppm in a working room and 80~100ppm in a machine room. Ammonia gas decreased 0.29mg/㎥ and the temperature of a working room dropped about 2.1~3.5$^{\circ}C$. The amount of air flow in a working room increased 23.2% at a site being 2m away from the entrance and 30.8% at a center. The inner temperature of the improved storage room showed that maximum temperature dropped about 3$^{\circ}C$, minimum temperature was high about 2$^{\circ}C$. The highest relative humidity was low 6%, the lowest one increased high about 10% when compared with the unimproved joint curing barns.

  • PDF

ROOM TEMPERATURE FERROMAGNETISM IN TRANSITION METAL DOPED OXIDE SEMICONDUCTORS, $TiO_2$ and ZnO

  • Y. H. Jeong;S-J. Han;Park, J.H.
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2003.06a
    • /
    • pp.17-17
    • /
    • 2003
  • Semiconductors with ferromagnetism at room temperature has been actively searched for in recent years; a prospect of devices using both charge and spin continuously gives impetus to the activities. Transition metal doped oxide materials have been of particular interest. Co substituted ZnO [1] and TiO$_2$ [2] thin films, for example, were reported to show ferromagnetic properties at room temperature. However, various studies do not seem to converge on a definite picture [3,4,5]. The issue is rather fundamental: whether a system shows ferromagnetic properties at all, and in case it does, whether the system possesses a close coupling between magnetism and transport properties. In this talk, we shall assess the current status of transition metal doped oxide materials as room temperature ferromagnetic semiconductors.

  • PDF

A Study on the Development of Oxygen Cluster Ion Generator for Sterilization of Bio Clean Room(BCR) (Bio Clean Room(BCR)의 멸균을 위한 산소 클러스터이온 발생 장치 개발에 관한 연구)

  • Park, Dong-Il;Chung, Kwang-Seop;Kim, Young-Il;Kim, Sung-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.1
    • /
    • pp.7-13
    • /
    • 2013
  • Bio Clean Room(BCR) and pharmaceutical product manufacturing facilities require careful assessment of many factors, including HVAC, controls, room finishes, process equipment, room operations, and utilities. Flow of equipment, personnel, and product must also be considered along with system flexibility, redundancy, and maintenance shutdown strategies. It is important to involve designers, operators, commissioning staff, quality control, maintenance, constructors, validation personnel, and the production representative during the conceptual stage of design. Critical variables for room environment and types of controls vary greatly with the clean space's intended purpose. It is particularly important to determine critical parameters with quality assurance to set limits and safety factors for temperature, humidity, room pressure, and other control requirements. In this paper, oxygen cluster ion equipment was utilized in order to enhance the indoor air quality and to prevent the airborne infection of ward in hospital. Moreover, the performance test of the equipment was also performed in order to develop the optimal sterilization system of BCR using the equipment.