• Title/Summary/Keyword: School buildings

Search Result 1,664, Processing Time 0.029 seconds

Estimation of the Potential Area for Roof Greening in Gyeonggi-do and Its Implications (경기도의 옥상녹화 가용면적 추정과 이의 정책적 함의)

  • Park, Eun-Jin;Nam, MiA;Kang, Gyui
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.15 no.1
    • /
    • pp.107-117
    • /
    • 2012
  • We estimated the potential area roof greening in Gyeonggi-do that will mitigate the heat island effect. The estimation was based on building age, roof shape, and building use which were recorded in the building register from "Sewoomteo, the Building Administration System in the Ministry of Land, Transport and Maritime Affairs. The estimated potential roof greening area in Gyeonggi-do was approximately $102.5km^2$ assuming that the buildings for residence, public, education(school), office, shopping mall are appropriate for roof greening. The area occupied by apartment buildings over six-story was 76.3% of the potential roof greening area 10.2% for individual houses, 5.9% for under five-story apartment buildings, and 3.7% for school buildings. The result indicated that it is residential buildings that we need to pay attention for roof greening, especially high-rise buildings over six-story. Greening of the whole estimated area, $102.5km^2$, in Gyeonggi-do will result in the increase of green space per capita by $8.74m^2$. This is 1.65 times greater than the area of current urban parks, and 1.97 times greater than the total area of neighborhood parks, children's parks, and pocket parks. Greening of the estimated roof area will increase green coverage of urban area by twice, adding to current green coverage of the urban areas, 11.3%, in 10 major cities. In particular, the effect of roof greening would be remarkable in inceasing the green space of Anyang City, Gwangmyeong City, and Guri City where neighborhood park area falls short.

Seismic demand estimation of RC frame buildings based on simplified and nonlinear dynamic analyses

  • Borzi, B.;Vona, M.;Masi, A.;Pinho, R.;Pola, D.
    • Earthquakes and Structures
    • /
    • v.4 no.2
    • /
    • pp.157-179
    • /
    • 2013
  • Vulnerability studies on the existing building stock require that a large number of buildings is analyzed to obtain statistically significant evaluations of the seismic performance. Therefore, analytical evaluation methods need to be based on simplified methodologies of analysis which can afford the treatment of a large building population with a reasonable computational effort. Simplified Pushover-Based Earthquake Loss Assessment approach (SP-BELA), where a simplified methodology to identify the structural capacity of the building through the definition of a pushover curve is adopted, was developed on these bases. Main objective of the research work presented in this paper is to validate the simplified methodology implemented in SP-BELA against the results of more sophisticated nonlinear dynamic analyses (NLDAs). The comparison is performed for RC buildings designed only to vertical loads, representative of the "as built" in Italy and in Mediterranean countries with a building stock very similar to the Italian one. In NLDAs the non linear and degrading behaviour, typical of the structures under consideration when subjected to high seismic loads, is evaluated using models able to capture, with adequate accuracy, the non linear behaviour of RC structural elements taking into account stiffness degradation, strength deterioration, and pinching effect. Results show when simplified analyses are in good agreement with NLDAs. As a consequence, unsatisfactory results from simplified analysis are pointed out to address their current applicability limits.

Experimental studies on steel frame structures of traditional-style buildings

  • Xue, Jianyang;Qi, Liangjie
    • Steel and Composite Structures
    • /
    • v.22 no.2
    • /
    • pp.235-255
    • /
    • 2016
  • This paper experimentally investigated the behavior of steel frame structures of traditional-style buildings subjected to combined constant axial load and reversed lateral cyclic loading conditions. The low cyclic reversed loading test was carried out on a 1/2 model of a traditional-style steel frame. The failure process and failure mode of the structure were observed. The mechanical behaviors of the steel frame, including hysteretic behaviors, order of plastic hinges, load-displacement curve, characteristic loads and corresponding displacements, ductility, energy dissipation capacity, and stiffness degradation were analyzed. Test results showed that the Dou-Gong component (a special construct in traditional-style buildings) in steel frame structures acted as the first seismic line under the action of horizontal loads, the plastic hinges at the beam end developed sufficiently and satisfied the Chinese Seismic Design Principle of "strong columns-weak beams, strong joints-weak members". The pinching phenomenon of hysteretic loops occurred and it changed into Z-shape, indicating shear-slip property. The stiffness degradation of the structure was significant at the early stage of the loading. When failure, the ultimate elastic-plastic interlayer displacement angle was 1/20, which indicated high collapse resistance capacity of the steel frame. Furthermore, the finite element analysis was conducted to simulate the behavior of traditional-style frame structure. Test results agreed well with the results of the finite element analysis.

Simplified formulas for evaluation of across-wind dynamic responses of rectangular tall buildings

  • Liang, Shuguo;Li, Q.S.;Zou, Lianghao;Wu, J.R.
    • Wind and Structures
    • /
    • v.8 no.3
    • /
    • pp.197-212
    • /
    • 2005
  • Tall buildings under wind action usually oscillate simultaneously in the along-wind and across-wind directions as well as in torsional modes. While several procedures have been developed for predicting wind-induced loads and responses in along-wind direction, accurate analytical methods for estimating across-wind and torsional response have not been possible yet. Simplified empirical formulas for estimation of the across-wind dynamic responses of rectangular tall buildings are presented in this paper. Unlike established empirical formulas in codifications, the formulas proposed in this paper are developed based on simultaneous pressure measurements from a series of tall building models with various side and aspect ratios in a boundary layer wind tunnel. Comparisons of the across-wind responses determined by the proposed formulas and the results obtained from the wind tunnel tests as well as those estimated by two well-known wind loading codes are made to examine the applicability and accuracy of the proposed simplified formulas. It is shown through the comparisons that the proposed simplified formulas can be served as an alternative and useful tool for the design and analysis of wind effects on rectangular tall buildings.

Comparison of Annual Heating and Cooling Loads of Internally and Externally Insulated Apartment Buildings According to the Location of Thermal Mass (내, 외단열 공동주택의 축열체 위치 차이에 따른 동단위 연간 냉난방부하 비교평가)

  • Koo, Bo-Kyoung;Lee, Beung-In;Choi, Doo-Sung;Song, Seung-Yeong
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.1
    • /
    • pp.42-49
    • /
    • 2010
  • The IIS(Internal Insulation System) is applied in most Korean apartment buildings which are the most common type of residential buildings. Consequently, there are many cases in which the layer of insulation is disconnected by the structural components at the wall-slab and wall-wall joints in the envelope. These joints become thermal bridges where the risk of heat loss increases. It is expected that the EIFS(External Insulation and Finish System) is the solution to this problem. In this study, annual heating and cooling loads of apartment buildings with IIS and EIFS were compared using Design Builder program in order to evaluate the thermal storage effect of EIFS where the concrete thermal mass is located inside of the insulation material. As results, the apartment building with EIFS could reduce annual heating and cooling loads by 2.4% and 4.1%, respectively.

Study on the Establishment of Large Building Airtightness Measurement Standards (대규모 건물의 기밀성능 측정기준 수립에 관한 연구)

  • Lee, Dong-Seok;Ji, Kyung-Hwan;Jo, Jae-Hun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.117-124
    • /
    • 2014
  • Airtightness standards using fan pressurization method are normally used for measuring small buildings, detached houses, and apartment units. And, it is easy to conduct airtightness measurement through this fan pressurization method. However, it can be difficult to achieve accurate measurement results for the large buildings as the height and volume of the buildings have been increased. In this paper, we studied the principle of airtightness method by fan pressurization. And, we reviewed the measurement process described in ISO 9972, EN 13829, ASTM E779, ATTMA TS 1, CAN/CGSB 149.15, and JIS A 2201. Then, we categorized the methods' items according by air flow rate (Q) and pressure difference(${\Delta}P$). As a result, we made a comparison analysis on the measurement methods appeared in each standards. And, we achieved 5 test conditions about air flow rate and pressure difference to state requirements for large buildings airtightness measurement.

Optimum stiffness values for impact element models to determine pounding forces between adjacent buildings

  • Jaradat, Yazan;Far, Harry
    • Structural Engineering and Mechanics
    • /
    • v.77 no.2
    • /
    • pp.293-304
    • /
    • 2021
  • Structural failure due to seismic pounding between two adjacent buildings is one of the major concerns in the context of structural damage. Pounding between adjacent structures is a commonly observed phenomenon during major earthquakes. When modelling the structural response, stiffness of impact spring elements is considered to be one of the most important parameters when the impact force during collision of adjacent buildings is calculated. Determining valid and realistic stiffness values is essential in numerical simulations of pounding forces between adjacent buildings in order to achieve reasonable results. Several impact model stiffness values have been presented by various researchers to simulate pounding forces between adjacent structures. These values were mathematically calculated or estimated. In this study, a linear spring impact element model is used to simulate the pounding forces between two adjacent structures. An experimental model reported in literature was adopted to investigate the effect of different impact element stiffness k on the force intensity and number of impacts simulated by Finite Element (FE) analysis. Several numerical analyses have been conducted using SAP2000 and the collected results were used for further mathematical evaluations. The results of this study concluded the major factors that may actualise the stiffness value for impact element models. The number of impacts and the maximum impact force were found to be the core concept for finding the optimal range of stiffness values. For the experimental model investigated, the range of optimal stiffness values has also been presented and discussed.

AUTOMATIC AS-IS BIM EXTRACTION FOR SUSTAINABLE SIMULATION OF BUILT ENVIRONMENTS

  • Chao Wang;Yong K. Cho
    • International conference on construction engineering and project management
    • /
    • 2013.01a
    • /
    • pp.47-51
    • /
    • 2013
  • Existing buildings now represent the greatest opportunity to improve building energy efficiency. Building performance analysis is becoming increasingly important because decision makers can have a better visualization of their building's performance and quickly make the solution for improving building energy efficiency and reducing environmental impacts. Nowadays, building information models (BIMs) have been widely created during the design phase of new buildings, and it can be easily imported to third party software to conduct various analyses. However, a BIM is not always available for all existing buildings. Even if a BIM is available during the design and construction phases, it is very challenging to keep updating it while a building is aged. A manual process to create or update a BIM is very time consuming and labor intensive. A laser scanning technology has been a popular tool to create as-is BIM. However it still needs labor-intensive manual processes to create a BIM out of point clouds. This paper introduces automatic as-is simplified BIM creation from point clouds for energy simulations. A framework of decision support system that can assist decision makers on retrofits for existing buildings is introduced as well. A case study on a residential house was tested in this study to validate the proposed framework, and the technical feasibility of the developed system was positively demonstrated.

  • PDF

Analysis of a Night Illuminance Distribution in School Buildings (학교 건축물의 야간 조도분포 분석)

  • 박동화;성낙진;신재화;이병기
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.6
    • /
    • pp.48-53
    • /
    • 1996
  • In this paper, the illuminance of elementary, junior, and senior high school in Inchon was measured and analyzed to investigate their night illuminating circumstances(classrooms, science rooms, and laboratories). More than four schools were selected based on the years elapsed(l0, 20, and 30 years, etc) since the opening of the schools. It was shown that the average illuminance for the classroom and that for science room and laboratory have been improved significantly such that the former was 235.6[lx] (260[lx] for senior high school, 208[lx] for junior high school, 203[lx]) for elementary school) and the latter was 233.7[lx](248.8[lx] for senior high school, 216.4[lx] for junior high school, 207.8[lx] for elementary school). The uniformity of the illuminance was exceedingly worse than the recommended one(the average value for the classroom and that for sciense room and laboratory were 0.95 and 1.08, respectively). It was found that the maximum to minimum illuminance ratio with respect to illumination derivative(7.9 for classroom, 6.8 for scienceroom or laboratory) was very high for most school buildings and was much higher for the old ones. From the measured results, it was shown that the illuminance for the school buildings needs to be improved with regard to quality.

  • PDF

A Study on the Efficiency of Public Library in Present Condition and Management Analysis (공공도서관 설치 현황과 운영 분석에 대한 효율화 방안 연구)

  • Yaon, Yong-Gi;Lee, Jae-Rim
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.6 no.1
    • /
    • pp.1-24
    • /
    • 2007
  • Public library is established on impartial accessibility of any distinction as their sex, age, financial status, etc. The function of public library is not only to accumulate materials and offer information but also minimize gulf between the rich and the poor by knowledge possession, which is realized by important means to intercept exclusive possession and power in knowledge pose-industrial society. As it is judged that most public library is established to individual building with thousands of cost, it is judged of obstacles to Increase library buildings. The purpose of this study is try to find the way to Increase In number of public library In Seoul by interaction local education-cultural facilities. The result from this study, the user rate of public library is influenced by number of buildings and accessibility of traffic and public library can improve efficiency by substantial operation by basic function for all age group. The target population of Seoul public library sizes by decuple of advanced countries because of difficulty of accessibility, so it needs to make it small scale and also can offer self-regulation learning, materials and life-long learning programs because generally public library's utilization purpose is different by age. As school in Seoul amounts to 25 times of public library by about 1,200 buildings and can function of lifelong education center with a school library, cultural center and other composition buildings, so school facilities may use as a public library for local residents.

  • PDF