• 제목/요약/키워드: Scattering, Radiation

검색결과 390건 처리시간 0.023초

유한체적 복사전달해석법을 이용한 주유동중에 놓인 원형실린더 주위에서의 복사-대류 열전달해석 (Analysis of Radiative-Convective Heat Transfer about a Circular Cylinder in Crossflow Using Finite Volume Radiation Solution Method)

  • 이공훈;이준식
    • 대한기계학회논문집B
    • /
    • 제20권1호
    • /
    • pp.346-358
    • /
    • 1996
  • A finite volume radiation solution method was applied to a non- orthogonal coordinate system for the analysis of radiative-convective heat transfer about a circular cylinder in crossflow. The crossflow Reynolds number based on the cylinder radius was 20, and the fluid Prandtl number was 0.7. The radiative heat transfer coupled with convection was reasonably predicted by the finite volume radiation solution method. The investigation includes the effects of conduction- to-radiation parameter, optical thickness, scattering albedo and cylinder wall-emissivity on heat transfer about the cylinder. As the conduction- to-radiation parameter decreases, the radiative heat transfer rate increases and conduction rate as well due to the increase in temperature gradient on the cylinder wall which is caused by radiation enhancement. With an increase in the optical thickness, the Nusselt number increases significantly and the temperature gradient shows similar behavior. Though the radiative heat transfer increases with the scattering albedo, the total heat transfer decreases. This is because the decrease in the conduction heat transfer exceeds the increase in the radiation heat transfer. As the wall- emissivity increases, the radiation absorbed in the vicinity of the cylinder wall increases and thereby the total heat transfer increases, even though the conduction heat transfer decreases.

STARS: A 3D GRID-BASED MONTE CARLO CODE FOR RADIATIVE TRANSFER THROUGH RAMAN AND RAYLEIGH SCATTERING WITH ATOMIC HYDROGEN

  • Chang, Seok-Jun;Lee, Hee-Won
    • 천문학회지
    • /
    • 제53권6호
    • /
    • pp.169-179
    • /
    • 2020
  • Emission features formed through Raman scattering with atomic hydrogen provide unique and crucial information to probe the distribution and kinematics of a thick neutral region illuminated by a strong far-ultraviolet radiation source. We introduce a new 3-dimensional Monte-Carlo code in order to describe the radiative transfer of line photons that are subject to Raman and Rayleigh scattering with atomic hydrogen. In our Sejong Radiative Transfer through Raman and Rayleigh Scattering (STaRS) code, the position, direction, wavelength, and polarization of each photon is traced until escape. The thick neutral scattering region is divided into multiple cells with each cell being characterized by its velocity and density, which ensures flexibility of the code in analyzing Raman-scattered features formed in a neutral region with complicated kinematics and density distribution. To test the code, we revisit the formation of Balmer wings through Raman scattering of the far-UV continuum near Lyβ and Lyγ in a static neutral region. An additional check is made to investigate Raman scattering of O vi in an expanding neutral medium. We find a good agreement of our results with previous works, demonstrating the capability of dealing with radiative transfer modeling that can be applied to spectropolarimetric imaging observations of various objects including symbiotic stars, young planetary nebulae, and active galactic nuclei.

Simple Calculation Method as a Supplementary Radiation Safety Assessment for Facility with Radiation Generator

  • Kim, Sang-Tae
    • International Journal of Contents
    • /
    • 제14권4호
    • /
    • pp.65-69
    • /
    • 2018
  • The objective of this study was to conduct a radiation shielding analysis for the facility equipped with radiation generator. The analysis was carried out in two aspects. First, from the aspect of the effect caused by primary and leakage radiation. Second, effect of scattered radiation was evaluated by applying a simple calculation method based on a scattering rate concept since effect of scattered radiation is significantly important at maze entrance of the radiation facility. The calculated results obtained using the simple method were compared to the results calculated using Geant4 code and the measured values. The results calculated by the suggested method indicate that slight error exists in a radiation shielding analysis done at the maze entrance comparing to other two results, while the results evaluated at the outside of the maze entrance door are relatively consistent with other values.

THE EFFECT OF SURFACE ROUGHNESS OF CSI(TL) MICRO-COLUMNS ON THE RESOLUTION OF THE X-RAY IMAGE; OPTICAL SIMULATION STUDY

  • Kim, Hyun-Ki;Bae, Jun-Hyung;Cha, Bo-Kyung;Jeon, Ho-Sang;Kim, Jong-Yul;Kim, Chan-Kyu;Cho, Gyu-Seong
    • Journal of Radiation Protection and Research
    • /
    • 제34권1호
    • /
    • pp.25-30
    • /
    • 2009
  • Micro-columnar CsI(Tl) is the most popular scintillator material which is used for many indirect digital X-ray imaging detectors. The light scattering at the surface of micro-columnar CsI(Tl) scintillator was studied to find the correlation between the surface roughness and the resultant image resolution of indirect X-ray imaging detectors. Using a commercially available optical simulation program, Light Tools, MTF (Modulation Transfer Function) curves of the CsI(Tl) film thermally evaporated on glass substrate with different thickness were calculated and compared with the experimental estimation of MTF values by the edge X-ray image method and CCD camera. It was found that the standard deviation value of Gaussian scattering model which is determined by the surface roughness of micro-columns could certainly change the MTF value of image sensors. This model and calculation methodology will be beneficial to estimate the overall performance of indirect X-ray imaging system with CsI(Tl) scintillator film for optimum design depending on its application.

발열체와 격막이 있고 일부가 열린 복합공간내의 자연대류-복사열전달에 관한 수치적 연구 (A numerical study on the combined natural convection and radiation in a partially open complex enclosure with a heater and partitions)

  • 김태국;민동호;한규익;손봉세;서석호
    • 대한기계학회논문집B
    • /
    • 제21권2호
    • /
    • pp.235-251
    • /
    • 1997
  • A numerical simulation on the combined natural convection and radiation is carried out in a partially open rectangular enclosure with a heater by using the finite volume and the S-8 discrete ordinate methods. The fluid inside the enclosure is considered as an absorbing, emitting and anisotropic scattering media. The heater causes a natural circulation of the fluid (10$^{5}$ $^{9}$ ) which results in significant in-flow of the ambient cold fluid through the partially open wall. Comparing the results of pure convection with those of the combined convection- radiation, the combined heat transfer results with small Planck numbers (P$_{l}$ <1.0) show much stronger circulation than those of the pure convection, and the fluid circulation is more evident for larger Rayleigh numbers. When one of three radiative properties - the medium absorption coefficient, the wall reflectivity, and the scattering albedo - increases, the fluid circulation and the heat transfer in the enclosure are reduced. The location of the heater and the open ratio of the right wall are also shown to affect the fluid circulation and heat transfer significantly. However, the anisotropy of the scattering phase function is shown to be unimportant for the fluid circulation and heat transfer within the enclosure considered in this study.

방사선 진단영역에서 방사선사의 부서별 의료피폭의 분석 (An Analysis of the Radiation Exposure of Radiologic Technologists in the Field of Diagnostic Radiology according to Duty Station)

  • 한재진;김승국
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권1호
    • /
    • pp.71-75
    • /
    • 1997
  • This study was Investigation that we will become aware of the scattering dose of duty station and TLD value of the radiation exposure by the radiation technologists based on the university hospital located in Kwang ju. The results are followings ; 1. The air of scattering dose in chest, when the number of objects are large, is 2.0 mR in P-A and 4.6 mR in Lat. at the back of X-ray tube 2. Radiologists, radiation exposure in duty station Is 0.22 mSv to 1.96 mSv in general examination, 0.22 mSv to 1.12 mSv in contrast and special examination, 0.26 mSv to 30.96 mSv in angiography, and 0.22 mSv to 0.40 mSv in C.T 3. The value of workig condition reveals 85.5% in general examination, 6% in contrast and special examination, and 5.8% in C.T. When the annual exposure is over 20 mSv, it must be measured again according to ICRP public 60.

  • PDF

X선촬영시(線撮影時) 연부조직(軟部組織) 두께에 따른 선량분포(線量分布)에 관(關)한 연구(硏究) (A Study on the Distribution of X-ray according to the Thickness of Soft Tissue in Radiography)

  • 박성옥
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제11권2호
    • /
    • pp.3-15
    • /
    • 1988
  • When X-rays were projected into a patient, there occured the phenomena such as penetration, absorption and scattering etc. The penetrating rays were recorded on films as X-ray image used for diagnosis but scattered rays caused the radiation hazard both to the patient, specialist and technicians. The soft tissue includes many organs which are sensitive to the radiation and in may occupy $40{\sim}50%$ of body weight. Therefore X-rays should be carefully projected to the patient and it is strongly recommended to analyse the distribution of X-rays, when ever the patient is exposed to X-rays. In this study, the distribution of X-ray according to the thickness, the radiation field and the tube voltages (kVp) in soft tissue, the following results were obtained: 1. Total transmitted rays which kept the step with X-ray tube voltage (kVp) increased in proportion to the increasing of X-ray tube voltage. 2. The scattered ray rate in the total transmitted ray was not significantly found with X-ray tube voltage. 3. The affecting factors of the scattered ray rate in total transmitted ray were shown through the radiation field and the thickness. 4. The dose of scattered ray by the angle was observed more in direction of primary ray ($0^{\circ}$) and back scattering ($160^{\circ}$) than in direction of $90^{\circ}$. 5. The more the distance from phantom to the patient should be less distribution of scattered ray.

  • PDF

단일산란근사법(單一散亂近似法)에 의한 공기중(空氣中) 산란방사선량(散亂放射線量)의 계산(計算) (Calculation of the Air-Scattering Dose Rate by the Single Scattering Approximation)

  • 육종철;하정우;이재기;문석형
    • Journal of Radiation Protection and Research
    • /
    • 제4권1호
    • /
    • pp.21-28
    • /
    • 1979
  • 공기중 산란감마선의 조직등가선량을 수정 단일산란근사법에 의하여 계산하였다. 공기중 산란 조직등가선량은 축적인자 및 지수감쇄 등 관심위치에서의 에너지 스펙트럼 및 3차원의 기하학적 산란체적을 고려하여 계산하였다. 이 계산방법은 차폐벽으로 둘러쌓인 농학적이용 목적의 대표적 감마조사시설과 시설의 방사선원의 방출감마선이 일정 범위내에만 조사되도록 하는 장치가 부착된 조사시설에 적용할 수 있도록 수정하였다. 선원과 피조사체 사이의 거리가 35m에서 300m 내에 있는 여러 위치에서의 에너지 스펙트럼, 각분포 그리고 조직등가선량율에 대한 계산결과를 얻었다. 3차원 계산방법에 의하여 구한 본 계산결과와 2차원 계산방법에 의하여 얻은 결과를 실제 측정값과 비교한 결과에 의하여 본 결과가 전반적으로실제 측정값과 좋은 일치를 보여 주었다. 만일에 차폐체에서의 에너지와 각 분포가 중요하지 않다고 하면 3차원 계산방법을 도입한 단일산란근사법은 일반적으로 감마조사 시설에서 공기중 산란방사선 문제들을 취급하는 데에 적합함을 알았다.

  • PDF

축과 수직방향으로 진동하는 유전체원주에 의한 평면파의 산란 (Electromagnetic Scattering by a Dielectric Column Oscillating in the Perpendicular Direction to its Axis)

  • 구연건;김두근
    • 한국통신학회논문지
    • /
    • 제9권3호
    • /
    • pp.113-119
    • /
    • 1984
  • 誘電體圓柱가 축에 수직한 방향으로 正弦的으로 振動할 때 이에 의한 電磁波의 散亂을 고찰하였다. 순간적인 振動速度와 같은 等速度가 있다고 가정하고 그 순간은 特殊相對性理論에 기초하여 散亂界를 구하고 이를 한 振動週期에 확대 적용하였다. 平均散亂電力의 角度分布와 散亂斷面績, 레이다斷面績의 평균을 平面波의 入射角, 振動振幅과 振動角速度로 표시되는 순간진동속도의 최대치를 변수로 하여 변화상태를 규명하였다. 冷플라즈마의 圓柱가 진동하는 경우도 검토하였다.

  • PDF