Evaluation and Analysis of Scattered Radiation Dose according to Factors in General X-ray Examination (일반엑스선영상검사의 인자에 따른 산란방사선량 평가 및 분석)

  • Dong-Kyung Jung;Myeong-Hwan Park;Jeong-Min Seo
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.13-19
    • /
    • 2024
  • Control of scattered radiation is one of very important factors in the use of medical radiation. In general X-ray exam, the causes, measurement methods, and the kind of detectors of scattered rays within the radiation area are diverse. In this study, the dose of scattered ray was measured by changing the thickness of the polycarbonate phantom and the tube voltage. As a result of measurement of scattered radiation, the results show that the scattered dose significantly(p<.05) increased with growing of thickness of phantom in the tube voltage 40, 50 and 60 kVp(F(p)<.05, R2>64%). As tube voltage increased at all phantom thicknesses, the scattered dose also significantly(p<.05) increased(F(p)<.05, R2>69%). In cases where a significant correlation was shown, the coefficient of determination of more than 60% was shown in regression analysis. The results of this study can be used as data on scattered radiation dose according to the tube voltage and the object thickness in general X-ray imaging exam.

Leakage and scattered radiation from hand-held dental x-ray unit (이동용 치과 X선 발생장치의 누설 및 산란 선량에 관한 연구)

  • Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.37 no.2
    • /
    • pp.65-68
    • /
    • 2007
  • Purpose: To compare the leakage and scattered radiation from hand-held dental X-ray unit with radiation from fixed dental X-ray unit. Materials and Methods: For evaluation we used one hand-held dental X-ray unit and Oramatic 558 (Trophy Radiologie, France), a fixed dental X-ray unit. Doses were measured with Unfors Multi-O-Meter 512L at the right and left hand levels of X-ray tube head part for the scattered and leakage radiation when human skull DXTTR III was exposed to both dental X-ray units. And for the leakage radiation only, doses were measured at the immediately right, left, superior and posterior side of the tube head part when air was exposed. Exposure parameters of handheld dental X-ray unit were 70 kVp, 3 mA, 0.1 second, and of fixed X-ray unit 70 kVp, 8 mA, 0.45 second. Results: The mean dose at the hand level when human skull DXTTR III was exposed with portable X-ray unit $6.39{\mu}Gy$, and the mean dose with fixed X-ray unit $3.03{\mu}Gy$ (p<0.001). The mean dose at the immediate side of the tube head part when air was exposed with portable X-ray unit was $2.97{\mu}Gy$ and with fixed X-ray unit the mean dose was $0.68{\mu}Gy$ (p<0.01). Conclusions: The leakage and scattered radiation from hand-held dental radiography was greater than from fixed dental radiography.

  • PDF

Change of the Scattered Dose by Field Size in X-ray Radiography (X선 촬영에서 조사야 크기에 따른 산란선량의 변화)

  • Choi, Seong-Kwan
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.3
    • /
    • pp.198-203
    • /
    • 2013
  • The purpose of this study is to investigate the scattered dose of X-ray at a distance of 30cm from the area to be examined when X-ray field is the most optimized and maximized when X-ray is performed on hand, skull and abdomen. As a result of scattered dose of X-ray on hand, skull and abdomen, first, when X-ray field was the most optimized upon adult X-ray examination, it was $0.08{\mu}Sv$, $4.39{\mu}Sv$ and $5.56{\mu}Sv$, respectively. When x-ray field was maximized, it was $0.58{\mu}Sv$, $33.47{\mu}Sv$ and $35.93{\mu}Sv$, respectively. Second, when X-ray field was the most optimized upon pediatric X-ray examination, it was $0.40{\mu}Sv$, $14.51{\mu}Sv$ and $18.86{\mu}Sv$, respectively. When x-ray field was maximized, it was $2.78{\mu}Sv$, $107.40{\mu}Sv$ and $117.52{\mu}Sv$, respectively(P<0.001). As a result, when the size of X-ray field was decreased down to be necessary and optimal upon X-ray examination, emission of scattered X-ray around specimen is reduced approximately 6-7 times as much as that when it was maximized.

Experimental Evaluation of Scattered X-Ray Spectra due to X-Ray Therapeutic and Diagnosis Equipment for Eye Lens Dosimetry of Medical Staff

  • Kowatari, Munehiko;Nagamoto, Keisuke;Nakagami, Koich;Tanimura, Yoshihiko;Moritake, Takashi;Kunugita, Naoki
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.1
    • /
    • pp.39-49
    • /
    • 2022
  • Background: For proper monitoring of the eye lens dose, an appropriate calibration factor of a dosimeter and information about the mean energies of X-rays are indispensable. The scattered X-ray energy spectra should be well characterized in medical practices where eye lenses of medical staffs might be high. Materials and Methods: Scattered X-ray energy spectra were experimentally derived for three different types of X-ray diagnostic and therapeutic equipment, i.e., the computed tomography (CT) scan, the angiography and the fluoroscopy. A commercially available CdZnTe (CZT) spectrometer with a lead collimator was employed for the measurement of scattered X-rays, which was performed in the usual manner. Results and Discussion: From the obtained energy spectra, the mean energies of the scattered X-rays lied between 40 and 60 keV. This also agreed with that obtained by the conventional half value layer method. Conclusion: The scattered X-rays to which medical workers may be exposed in the region around the eyes were characterized by means of spectrometry. The obtained mean energies of the scattered X-rays were found to match the flat region of the dosimeter response.

A Study on the Distribution of X-ray according to the Thickness of Soft Tissue in Radiography (X선촬영시(線撮影時) 연부조직(軟部組織) 두께에 따른 선량분포(線量分布)에 관(關)한 연구(硏究))

  • Park, Soung-Ock
    • Journal of radiological science and technology
    • /
    • v.11 no.2
    • /
    • pp.3-15
    • /
    • 1988
  • When X-rays were projected into a patient, there occured the phenomena such as penetration, absorption and scattering etc. The penetrating rays were recorded on films as X-ray image used for diagnosis but scattered rays caused the radiation hazard both to the patient, specialist and technicians. The soft tissue includes many organs which are sensitive to the radiation and in may occupy $40{\sim}50%$ of body weight. Therefore X-rays should be carefully projected to the patient and it is strongly recommended to analyse the distribution of X-rays, when ever the patient is exposed to X-rays. In this study, the distribution of X-ray according to the thickness, the radiation field and the tube voltages (kVp) in soft tissue, the following results were obtained: 1. Total transmitted rays which kept the step with X-ray tube voltage (kVp) increased in proportion to the increasing of X-ray tube voltage. 2. The scattered ray rate in the total transmitted ray was not significantly found with X-ray tube voltage. 3. The affecting factors of the scattered ray rate in total transmitted ray were shown through the radiation field and the thickness. 4. The dose of scattered ray by the angle was observed more in direction of primary ray ($0^{\circ}$) and back scattering ($160^{\circ}$) than in direction of $90^{\circ}$. 5. The more the distance from phantom to the patient should be less distribution of scattered ray.

  • PDF

Measurement of the Scattered Spatial Dose Distribution for the Mobile X-ray Radiography (이동형 X선촬영에서 공간산란선량 분포 측정)

  • Kwon, Deok-Mun;Park, Myeong-Hwan;Nam, Hyo-Duk
    • Journal of radiological science and technology
    • /
    • v.24 no.1
    • /
    • pp.23-26
    • /
    • 2001
  • The spatial distribution of the scattered dose for mobile X-ray radiography is measured. The scattered X-ray exposures at the radius of 50, 100 and 150 cm from the irradiation center are 880, 180 and $50\;{\mu}R$, respectively. This scattered X-rays can be reduced to 60% by inserting the portable shield made by 0.4 mm copper sheet sandwiched in two plywoods.

  • PDF

Utility of Wearing Protective Apron for X-ray of Thick Subject (두꺼운 피사체 X선 촬영 시 보호앞치마 착용의 유용성)

  • Choi, Seong-Kwan;Dong, Kyung-Rae
    • Journal of Radiation Industry
    • /
    • v.11 no.3
    • /
    • pp.167-171
    • /
    • 2017
  • This study examined the effectiveness degree of a protective apron that is taken not to be exposed to the first ray or scattered rays, for X-ray of thick subject like lateral lumbar, and the results are as follows; First, spatial dose by scattered rays is shielded by 3 mmPb protective apron, 86.8% at a distance of 50 cm, 92.7% at 100 cm, and 95.6% at 200 cm, when minimizing the field size, while 89% at a distance of 50 cm, 92.3% at 100 cm, and 95.2% at 200 cm, when maximizing the field size. Second, 1st exposure dose is shielded by 3 mmPb protective apron, 93.7% at a distance of 50 cm, 94.4% at 100 cm, and 93.6% at 200 cm, when minimizing the field size, while 93.7% at a distance of 50 cm, 93.6% at 100 cm, and 94.2% at 200 cm, when maximizing the field size.

A Study on the Factors of Spatial Scattered Ray Occurrence in the X-ray Radiography Room (엑스선 촬영실의 공간산란선 발생 인자에 관한 연구)

  • Na, Soo-Kyung;Han, Sang-Hyo
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.393-399
    • /
    • 2009
  • In this study, we measured the dose distribution of scattered ray in X-ray radiography room using an ion chamber and examined the dependency of scattered ray content on the scattered ray source and exposure condition. To study the factors of scattered ray occurrence in the acryl phantom, we measured the change in the scatted ray content according to the X-ray tube voltage (40~140 kV) and the field size ($10{\times}10\;cm^2$, $20{\times}20\;cm^2$, $35{\times}35\;cm^2$). For the $35{\times}35\;cm^2$ field size, the side-scattering rate ranged from 3.1% to 14.5%. The scattered ray contributions of the phantom, collimator, X-ray tube and wall were also measured. The scattered ray contribution of the phantom was higher than 95.4% for the entire tube voltage, and those of the collimator, X-ray tube and wall were 2.6%, 1.3% and 0.7%, respectively.

  • PDF

Effects of the Scattered Radiation on Image Quality and Exposure Dose in Chest Radiography (흉부X선촬영시(胸部X線撮影時) 산란선(散亂線)이 화질(畵質)과 피폭선량(被曝線量)에 미치는 영향(影響))

  • Iino, Yu;Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakurai, Tatsua;Lee, Man-Koo;An, Bong-Sun;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.16 no.2
    • /
    • pp.27-38
    • /
    • 1993
  • To investigate relationships between image guality and exposure dose, Chest X-ray films were evaluated for the following points:how much scattered radiation can affect reduction in image quality and can be permissible diagnostically? For this purpose using a test charts and Burger's phantoms. The visual evaluation of their X-ray films and the measurements of scattered radiation were carried out. The dose of scattered radiation ranging from 20 to 25% was found to be for nothing in any diagnostic obstacle. In this range, surface doses were low of 17, 21, and $25{\mu}Gy$ for The thickness of the chest of 15, 20 and 25 cm respectively. Comparison of these high voltage X-ray films with low voltage ones showed a surface dose rate of 1:11.7. Therefore, X-ray quality, photosensitive materials(film and screen) and grid should be selected very carefully for the purpose of reduction in exposure dose.

  • PDF

Development of Radiation Restrictor for Secondary Radiation Shielding of Mobile X-ray Generator (이동형 X선 발생장치의 2차 방사선 차폐를 위한 선속조절기 개발 연구)

  • Koo, Bon-Yeoul;Kim, Gha-Jung
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.397-403
    • /
    • 2018
  • Mobile X-ray generators are used not in the radiation area but in open space, which causes the exposure of secondary radiation to the healthcare professionals, patients, guardians, etc., regardless of their intentions. This study aimed to investigate the shielding effect of the developed radiation restrictor to block the secondary radiation scattered during the use of mobile X-ray generator. Upon setting the condition of mobile X-ray generator with chest AP, spatial doses were measured by the existence of human equivalent phantom and radiation restrictor, and measured by the existences of phantom and radiation restrictor at the same length of 100 cm. Measurements were taken at intervals of 10 cm every $30^{\circ}$ from $-90^{\circ}$ (head direction) to $+90^{\circ}$ (body direction). Upon the study results, spatial doses in all direction were increased by 45% on average when using phantom in the same condition, however, they were decreased by 64% on average when using the developed radiation restrictor. The dose at 100 cm from the center of X-ray was $3.0{\pm}0.08{\mu}Gy$ without phantom and was increased by 40% with $4.2{\pm}0.08{\mu}Gy$ after phantom usage. The dose when using phantom and the developed radiation restrictor was $1.4{\pm}0.08{\mu}Gy$, which was decreased by 66% compared to the case without using them. Therefore, it is considered the scattered radiation can be shielded at 100-150 cm, the regulation of the distance between beds, effectively with the developed radiation restrictor when using mobile X-ray generators, which can lower the radiation exposure to the people nearby including healthcare professionals and patients.