• 제목/요약/키워드: Scanning height

검색결과 246건 처리시간 0.026초

T-Scanning Method에 의한 접합 경계면의 화상해석 (Image analysis of boundary surface using T-scanning Method)

  • 김재열
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1998년도 추계학술대회 논문집
    • /
    • pp.60-65
    • /
    • 1998
  • Recently, It is gradually raised necessity that thickness of thin film is measured accuracy and managed in industrial circles and medical world. Ultrasonic Signal processing method is likely to become a very powerful method for NDE method of detection of microdefects and thickness measurement of thin film below the limit of Ultrasonic distance resolution in the opaque materials, provides useful information that cannot be obtained by a conventional measuring system. In the present research, considering a thin film below the limit of Ultrasonic distance resolution sandwiched between three substances as acoustical analysis model, demonstrated the usefulness of ultrasonic Signal processing technique using information of ultrasonic frequency for NDE of measurements of thin film thickness, sound velocity, and step height, regardless of interference phenomenon

  • PDF

Micro-CT 스캐닝을 통한 섬유보강 콘크리트 기둥내부 강섬유의 배향성 및 위치분포 분석 (Analysis of Orientation and Distribution of Steel Fiber in Fiber Reinforced Concrete Column by Micro-CT Scanning)

  • 박태훈;서형원;배성철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.23-24
    • /
    • 2019
  • In this study, analysis of steel fiber orientation and distribution inside fiber reinforced concrete was performed using micro-CT scanning technology. Samples were extracted from the column according to its height and distance from the mold. Samples were scanned in order to attain the image of steel fibers then region of interest were obtained by binarization process. By calculating the principle moment of inertia of each fiber, direction vector, scale, center postion, volume, and surface area were gained in order to analyze the orientation and distribution. Most of the fibers inside the column tended to be perpendicular to the main axis of the column. Moreover, most of the fibers appeared at the bottom of the column and at the position where it is farthest from the mold.

  • PDF

다공성 티타늄 임플란트의 생리활성물질 담지특성에 관한 연구 (A study of loading property of the bioactive materials in porous Ti implants)

  • 김영훈
    • 대한치과기공학회지
    • /
    • 제35권4호
    • /
    • pp.281-286
    • /
    • 2013
  • Purpose: Surface modification is important techniques in modern dental and orthopedic implants. This study was performed to try embedding of bioactive materials in porous Ti implants. Methods: Porous Ti implant samples were fabricated by sintering of spherical Ti powders in a high vacuum furnace. It's diameter and height were 4mm and 20mm. Embedding process was used to suction and vacuum chamber. Loading properties of porous Ti implants were evaluated by scanning electron microscope(SEM), confocal laser scanning microscope(CLSM), and UV-Vis-NIR spectrophotometer. Results: Internal pore structure was formed fully open pore. Average pore size and porosity were $10.253{\mu}m$ and 17.506%. Conclusion: Porous Ti implant was fabricated successfully by sintering method. Particles are necking strongly each other and others portions were vacancy. This porous structure can be embedded to bioactive materials. Therefore bioactive materials will be able to embedding to porous Ti implants. Bioactive materials embedding in the porous Ti implant will induced new bone faster.

3차원 바디 스캐너를 이용한 남성 상반신 인체측정 -직접측정과의 비교- (Upper Body Measurement of Men using 3D Body Scanner -Compared to Anthropometry-)

  • 백경자;이정란
    • 한국의류학회지
    • /
    • 제32권1호
    • /
    • pp.24-34
    • /
    • 2008
  • Three dimensional body scan technology is being targeted for utilization in the apparel industry. The purpose of this study was to test reliability of the body scan data targeting from 20 to 24 year old men by comparing 3DM, 3D body-scanning semi-auto measurement extraction method, Scanworx, 3D body-scanning auto measurement extraction method, and traditional anthropometric method. We found significant differences in 9 out of 25 items in upper body measurements using 3DM and 16 out of 25 items using Scanworx. In the range of difference value of scan measures, it showed 1 item in the absolute value of more than 40mm between two measuring methods, 3 items in 20 up to 40mm, and less than 20mm in other items. Overall, in height items, the numerical value of traditional measure was higher and in girth, width, depth items, 3D scan measure was higher. We found out that reliability of 3D measurements taken from whole body scans was different according to scanners, scanning softwares, programs, and subjects.

파장 주사 간섭계를 이용한 불연속면의 표면 형상 측정 알고리즘 (An Algorithm for Discontinuous Surface Profile Measurement using Wavelength Scanning Interferometer)

  • 우현구;강철무;조형석
    • 제어로봇시스템학회논문지
    • /
    • 제9권7호
    • /
    • pp.507-514
    • /
    • 2003
  • Inspection and shape measurement of three-dimensional objects are widely needed in industries for quality monitoring and control. Recently the shape measurement using interferometric principle is found to be a successful methodology among other visual or optical technologies. Especially, the measuring method using wavelength scanning interferometer(WSI) has a great advantage in comparison with other conventional jnterferometric methods in that the absolute distance from the reference surface can be directly obtained from the amount of jnterferometric phase change. However, the measurement methods using WSI proposed by other researchers have low measurement resolution so far because they can't measure fractional phase change. To avoid this shortcoming we propose a new algorithm in this paper, which can obtain a small amount of even fractional phase change by sinusoidal function fitting. To evaluate the effectiveness of the proposed sinusoidal function fitting algorithm, a series of measuring experiments are conducted for discontinuously shaped specimens which have various height. The proposed algorithm shows much more enhanced measurement resolution than other existing conventional algorithms such as zero crossing algorithm and Fourier transform algorithm.

The Influence of the Annealing of Corn Starch on the formation and Characteristics of Enzyme-resistant Starch

  • Yoon, Ji-Young;Lee, Young-Eun
    • Preventive Nutrition and Food Science
    • /
    • 제4권4호
    • /
    • pp.215-220
    • /
    • 1999
  • The Physical properties of corn starch were investigated by scanning electron microscopy, X-ray diffractometry and differential scanning calorimetry during the formation of enzyme-resistant starch(RS). Samples were studied in their native states and after annealing at 50, 55, 60 and 65℃ in excess water(starch : water=1:3) for 48hr. Starch granules became smaller and more rounded after annealing than in their native state. Annealing did not change the X-ray profile of native corn starch. After autoclaving-cooling cycles, native starch lost most of its crystallinity but annealed ones showed some of their crystallinity left as diffuse or poor B-type, which didn't relate to increasing Rs yields. During formation of RS, however, both native and annealed starches changed their X-ray profile from A-type to poor B-type of retrograded amylose. Annealing caused an increase in gelatinization temperature and enthalpy, but a narrowing of gelatinization temperature range. Only starch annealed at 65℃, however, showed a decrease in enthalpy even though its gelatinization temperature increased, which appeared to be due to the partial gelatinization in the amorphous region during annealing. Peak height index(PHI), the ratio of ΔH to Ti-To, increased by annealing. PHI values, therefore, showed the possibility as an indicator to predict RS yield which cannot be differentiated by differential scanning calorimetry and X-ray diffraction data.

  • PDF

Comparative scanning electron microscope analysis of the enamel of permanent human, bovine and porcine teeth

  • Olek, Aneta;Klimek, Leszek;Boltacz-Rzepkowska, Elzbieta
    • Journal of Veterinary Science
    • /
    • 제21권6호
    • /
    • pp.83.1-83.14
    • /
    • 2020
  • Background: Bovine and porcine teeth are often used in in vitro experiments as substitutes of human teeth. Objectives: The aim of the present study was to perform a comparative analysis of enamel morphology of permanent human, bovine and porcine teeth under the scanning electron microscope. Methods: As many as 10 human, 10 bovine, and 10 porcine teeth were studied. All the teeth were sectioned and the halves were randomly divided into 2 groups according to the examined tissue (vestibular enamel at the mid-height of the dental crown and in the cervical area). Human and bovine enamel was etched for 15 sec and porcine enamel for 30 sec. The scanning electron microscope analysis was performed. The length and width of enamel prisms were determined with the "Met-Ilo" 1.1 computer program. Results: All enamel samples revealed the same etching pattern-Silverstone's type 2. Bovine enamel showed a similar porosity and the amount of interprismatic enamel compared to human enamel while the amount and width of interprismatic enamel bands in porcine enamel were evidently greater. The shape of the porcine prisms was visually similar to human prisms, although dimensions were significantly different. However, bovine prisms differed in form and appeared to be distinctly elongated. Conclusions: Reported findings indicate that the results of experimental studies carried out on bovine and porcine enamel should not be compared with the results obtained on human enamel.

한국 젊은 성인의 정규화된 아치 높이에 따른 발 유형 분석 (Analysis of Foot Type in Korean Young Adults Based on Normalized Arch Height)

  • 정도영
    • 한국전문물리치료학회지
    • /
    • 제27권3호
    • /
    • pp.199-205
    • /
    • 2020
  • Background: The classification of foot type can be commonly determined by the height of the media longitudinal arch. The normalized arch height (NAH) is defined as the ratio of navicular or instep heights to the foot length or instep length. Objects: This study investigated the relationships among foot characteristics, such as foot length (FL), instep length (IL), navicular height (NH), and instep height (IH), in Korean young adults. Also, the distribution of foot type based on calculated NAH was assessed. Methods: Three-dimensional foot scanning data of young adults aged 20 to 39 years (total: 1,978; 974 male, 1,004 female) were obtained from the Korea Technology Standards Institute, and used for analyses. NAH was calculated as the following: NH/FL, IH/FL, IH/IL, NH/IL. Spearman's rank order correlation was used to identify correlations among variables. The Mann-Whitney U-test and chi-square test were used to compare the sex differences in foot characteristics and distribution of foot type. Results: FL and IL showed a very high correlation (r = 0.94). The correlations between FL or IL and IH (r = 0.50-0.57) were greater than those between FL or IL and NH (r = 0.23-0.72). Males had significantly larger values than females (p < 0.001), and the frequency of pes planus was significantly higher in females than in males (χ2 = 50.09, p < 0.001). Based on the IH/IL index, the neutral foot, pes planus and pes cavus distributed by 16%, 78%, and 6% respectively. Conclusion: Our results on foot arch distribution could be used as basic data in clinical or footwear fields, and our data on differences in arch structure according to sex may facilitate understanding of why injury to the lower limbs differs between males and females.

Usefulness of 3-Dimensional Body Surface Scanning in the Evaluation of Patients with Pectus Carinatum

  • Song, Seung Hwan;Kim, Chong Hoon;Moon, Duk Hwan;Lee, Sungsoo
    • Journal of Chest Surgery
    • /
    • 제53권5호
    • /
    • pp.301-305
    • /
    • 2020
  • Background: Radiographic modalities have been commonly used to evaluate pectus carinatum (PC), and compressive orthotic bracing is the most widely accepted treatment method. The aim of this study was to determine the efficacy of 3-dimensional (3D) body surface scanning as an alternative modality for the evaluation of PC. Methods: The medical records of 63 patients with PC who were treated with compressive orthotic bracing therapy between July 2017 and February 2019 were retrospectively analyzed. Using both 2-view chest radiography (posteroanterior and lateral view) and 3D body scanning, the height of maximal protrusion of the chest wall was measured both before and after 2 weeks of bracing therapy. The difference between the pre- and post-treatment measurements was calculated for both modalities, and these differences were compared and analyzed. Results: Based on the comparison between the pre- and post-treatment radiographs, bracing therapy produced favorable outcomes in all patients (p<0.001). The measurements obtained via 3D scanning were strongly correlated with those obtained via chest radiography (r=0.60). Conclusion: Based on the findings of this study, 3D body surface scanning appears to be an effective, radiation-free, and simple method for the post-treatment follow-up evaluation of PC, and thus can be considered an alternative to radiography.

The Effect of Slider Surface Texture on Flyability and Lubricant Migration under Near Contact Conditions

  • Zhou, L.;Kato, K.;Vurens, G.;Talke, F.E.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.277-278
    • /
    • 2002
  • Magnetron and Ion beam sputtering were used to texture the air-bearing surface of magnetic recording sliders. Flying height measurements and Laser-Doppler interferometry were used to compare the 'flyability' of textured and untextured sliders. Lubricant redistribution on the disk surface caused by slider/disk interactions was investigated using scanning ellipsometry (Surface Reflectance Analyzer (SRA)). The results show that slider surface texture causes only small changes in the flying height of sliders but reduces slider in-plane and out-of-plane vibrations. Textured sliders were found to cause less lubricant depletion on the disk surface than untextured sliders.

  • PDF