• 제목/요약/키워드: Scanning Method

검색결과 3,731건 처리시간 0.031초

역공학기반의 프레스 부품 변형 보정에 관한 연구 (A Study on deformation compensation of press part based on reverse engineering)

  • 김광희;이윤영
    • 한국산학기술학회논문지
    • /
    • 제14권1호
    • /
    • pp.28-32
    • /
    • 2013
  • 본 연구에서는 프레스 부품의 스프링 백을 보정하기 위한 새로운 방법론을 제안하였다. 먼저, CAD 데이터와 측정데이터 사이의 오차를 비교하였다. 새로운 방법은 스프링 백을 보정하기 위한 수동적인 모델링 공정 대체가 가능한 3차원 측정데이터 기반의 자동 모델링을 제안하였다. 본 연구를 통해 프레스 부품의 스프링 백 보정을 위한 새로운 방법론을 적용하면 실제 공정에 소요되는 시간 및 비용 절감이 가능할 것으로 기대된다.

모드형상분석을 위한 연속 스캐닝 레이저 도플러 진동측정기 (A Continuous Scanning Laser Doppler Vibrometer for Mode Shape Analysis)

  • 박기환;최지은;라종필;왕세명;경용수;김경석
    • 대한기계학회논문집A
    • /
    • 제27권5호
    • /
    • pp.734-741
    • /
    • 2003
  • This paper addresses the vibration mode shape Measurement technique utilizing a Continuous Scanning Laser Doppler Vibrometer (CSLDV). The continuous scanning capability is added to the conventional discrete Laser Doppler Vibrometer by reflecting the laser beams on the surface of the object using two oscillating mirrors. The bow scanning resulted from the proposed scanning method is eliminated by feedback control. The velocity output signal from the CSLDV is modulated to give the spatial velocity distribution in terms of coefficients which are obtained from the Fast Fourier Transformation of the time dependent velocity signal. Using the Chebyshev series from, the analysis of the vibration mode shape techniques for straight line scanning and 2 dimensional scanning are presented and discussed. The performance of the proposed SLDV is presented using the experimental results of the vibration mode shape of a cantilever and plate

항공레이저 측량 자료의 해상도에 따른 DEM 오차 비교평가 연구 (Comparison and Evaluation on DEM Error by the Resolution of Airborne Laser Scanning Data)

  • 이근상;고덕구;채효석;신영호
    • 한국지리정보학회지
    • /
    • 제6권3호
    • /
    • pp.33-42
    • /
    • 2003
  • 최근 높은 수직정확도를 갖는 항공레이저측량 기술이 개발됨에 따라 이를 이용한 DEM(digital elevation model) 생성, 건물추출, 홍수위험지도 제작, 3차원 도시모델 구축 등의 다양한 연구가 활발하게 수행되고 있다. 본 연구에서는 항공레이저측량으로부터 취득한 원시자료로부터 생성한 해상도별 DEM의 표준편차를 계산하기 위해 점비교법, 등고선비교법 그리고 1/5,000 수치지형도를 활용하였다. 비교결과 점비교법이 등고선비교법보다 낮은 DEM 표준오차를 나타냈으며, 이것은 등고선비교법이 점비교법에 비해 조밀한 격자 연산이 이루어지지 않은 것이 원인으로 파악되었다. 또한 1/5,000 수치지형도는 평균수평거리인 25.4m 이하에서는 점비교법과 등고선비교법에 비해 높은 오차를 보였으며, 25.4m 이상에서는 등고선비교법과 유사한 결과를 나타냄을 알 수 있었다.

  • PDF

Blood Viscosity Measurements Using a Pressure-Scanning Capillary Viscometer

  • Sehyun Shin;Keum, Do-Young;Ku, Yun-Hee
    • Journal of Mechanical Science and Technology
    • /
    • 제16권12호
    • /
    • pp.1719-1724
    • /
    • 2002
  • A previously designed capillary viscometer with measuring differential pressure was modified to measure the viscosity of non-Newtonian fluids including unadulterated blood continuously over numerous shear rates in a single measurement. Because of unavoidable experimental noise and a limited number of data, the previous capillary viscometer experienced an inaccuracy and could not directly determine a viscosity without an iterative calculation. However, in the present measurement there are numerous data available near the point of interest so that the numeric value of the derivative, d(In Q)/d(In Q$\sub$w/), is no longer sensitive to the method of differentiation. In addition, relatively low and wide shear rate viscosity measurements were possible because of the present precision pressure-scanning method with respect to time. For aqueous polymer solutions, excellent agreement was found between the results from the pressure-scanning capillary viscometer and those from a commercially available rotating viscometer. In addition, the pressure-scanning capillary viscometer measured the viscosity of unadulterated whole blood without adding any anticoagulants.

이전 매크로블록의 양자화계수 누적값을 이용한 매크로블록 마다 가변적인 양자화계수 탐색방법 (A Variable Quantization Coefficient Scanning for Macroblock Considering the Histogram Value of Previous Macroblock's Quantization Coefficient)

  • 현명한
    • 한국군사과학기술학회지
    • /
    • 제14권2호
    • /
    • pp.281-288
    • /
    • 2011
  • In this paper, a variable quantization coefficient scanning for macroblock considering the histogram value of previous macroblock's quantization coefficient is proposed. In order to scan a quantization coefficient, the proposed method makes $4{\times}4$ histograms for various prediction modes($16{\times}16$, $16{\times}8$, $8{\times}16$, $8{\times}8$) by adding 1 if the value of quantization coefficient is not 0. After a final mode decision procedure, the $4{\times}4$ histogram of the final mode will be sorted. Then, quantization coefficients in corresponding macroblock of the next frame are scanned using the sorted order. The experimental results show that the proposed scheme reduces the total bits by approximately 0.01~2.25% with similar PSNR performance compared with the previous method.

알지네이트를 이용한 체표면적 측정방법과 삼차원 스캐닝에 의한 체표면적 측정방법의 비교 (Comparison between Alginate Method and 3D Whole Body Scanning in Measuring Body Surface Area)

  • 이주영;최정화
    • 한국의류학회지
    • /
    • 제29권11호
    • /
    • pp.1507-1519
    • /
    • 2005
  • The purpose of this study was to compare two methods of measuring body surface area (BSA). The BSA of Korean adults was measured using both three-dimensional (3D) scanning and an alginate method. Two males (one overweight and one lean) and one overweight female participated as subjects. The results were as follows: First, the 3D scanned BSA of all three subjects was smaller than the BSA measured using the alginate method by as much as $6-14\%$. The difference in methods was greater in the overweight participants than in the lean subject. Second, the results comparing the BSA obtained using these two methods and the BSA estimated by 10 previously developed formulas, showed that the 3D scanned BSA was the smallest among the 12 BSAs. Third, in comparing the regional differences between these two methods, the regional BSA of the lean subject (male 2) did not show any significant difference, but the overweight subjects (male 1, female 1) showed a significant difference. Forth, the biggest difference in regional BSA obtained through these two methods was in the hand, for all three subjects. The 3D scanned hand surface area was smaller than the hand surface area measured by the alginate method by as much as $24-34\%$. Fifth, in the percentage of regional BSA, there was no significant difference in these two methods. The reasons for the underestimation in the 3D scanning might be because: 1) the 3D scanner can not recognize the folding and shading of body parts, such as the finger, toe, ear, armpit, crotch and breast, 2) 3D patching and smoothing processes depend on researchers. However, the 3D scanning method is applicable to the estimation of the entire BSA, if the surface area of the hands is known, and the participant is not overweight.

공초점 주사현미경을 통한 미세 유로에서의 유동 가시화 (Flow Visualization in Microchannel Using Confocal Scanning Microscope)

  • 장준근;박성진;김중경;한동철
    • 한국가시화정보학회지
    • /
    • 제1권1호
    • /
    • pp.28-33
    • /
    • 2003
  • This paper presents the visualization method in which 3-dimensional(3D) microchannel flow can be detected using a confocal scanning microscope. By soft-lithography, we fabricated various Bio-MEMS(Micro Electro-Mechanical System) devices such as a disposable microchip for a flow cytometer and a micro-mixer, which have 3D structures. Injecting aqueous fluorescent solution in the microfluidic devices, we measured the flow in a steady state by the confocal scanning microscope. At first, we explain the principle of the confocal scanning microscope. And then we show the results from 3D visualization of microscopic flow structures using the confocal scanning microscope.

  • PDF

Mobile Robot Localization using Range Sensors: Consecutive Scanning and Cooperative Scanning

  • Lee Sooyong;Song Jae-Bok
    • International Journal of Control, Automation, and Systems
    • /
    • 제3권1호
    • /
    • pp.1-14
    • /
    • 2005
  • This paper presents an obstacle detection algorithm based on the consecutive and the cooperative range sensor scanning schemes. For a known environment, a mobile robot scans the surroundings using a range sensor that can rotate 3600°. The environment is rebuilt using nodes of two adjacent walls. The robot configuration is then estimated and an obstacle is detected by comparing characteristic points of the sensor readings. In order to extract edges from noisy and inaccurate sensor readings, a filtering algorithm is developed. For multiple robot localization, a cooperative scanning method with sensor range limit is developed. Both are verified with simulation and experiments.

직사각형 다중 양자 우물 도파관의 모드특성 분석 : Scanning angle method를 사용한 새로운 접근 (Modal Analysis of Rectangular MQW Waveguide : A Novel Approach using Scanning Angle Method)

  • 임연섭;최영완
    • 대한전자공학회논문지SD
    • /
    • 제37권4호
    • /
    • pp.45-52
    • /
    • 2000
  • 본 논문에서는 직사각형 다중 양자 우물 광 도파관의 간단하고 효율적인 분석을 위한 새로운 모의 실험방법을 제시한다. 우선적으로 2 차원 도파관 구조는 유효 굴절률 법을 사용하여 1 차원 도파관 구조로 변형되고 이렇게 얻어진 등가의 평면 다중 양자 우물 도파관의 도파 특성 행렬은 새롭게 제시된 각도 스캔법(scanning angle method)에 의하여 분석된다. 직사각형 다중 양자 우물 도파관의 유효 굴절률, 모드 전장세기, 광 구속 인자는 이 방법을 사용하여 효율적으로 얻을 수 있다. 모의 실험결과는 유한 요소 법에 기초된 해와 거의 정확한 일치를 보인다. 또한 직사각형 다중 양자 우물 도파관의 분석을 위한 두 가지의 근사 해석 방식을 새롭게 도입하고 그 방식들의 유효성을 검증하였다. 퍼터베이션 분석(perturbation analysis)을 사용하여 직사각형 다중양자 우물 도파관에서 전송되는 모드의 전력 손실 계수를 새롭게 유도하고 평면 다중 양자 우물 도파관 근사를 사용한 전형적인 방법의 결과와 비교하였다.

  • PDF

초음파 속도법을 활용한 강판의 두께 변화 탐지를 위한 기초연구 (A Basic Study on the Varying Thickness Detection of Steel Plate Using Ultrasonic Velocity Method)

  • 김우석;문성모;김철민;임석빈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권6호
    • /
    • pp.146-152
    • /
    • 2020
  • 본 연구는 강교량의 폐합부재 등 시각적으로 탐지하기 어려운 부위의 강재에 대한 손상을 탐지하기 위한 방법을 개발하기 위한 목적의 기초연구이다. 여러 비파괴 방법들 중에서 초음파 속도법을 활용하여 두께가 다른 시편에 대해서 초음파 속도법을 실시하여, 평균 매질내 전파속도를 도출하였고, 이를 활용하여 강재 부재에 대한 회귀분석을 실시하였다. 동일한 재료일 경우 회귀분석의 결과를 활용하면 다른 부재의 두께를 도출할 수 있을 것으로 예상된다. 또한, 광범위한 범위를 스캐닝하기 위해 200 mm/s로 이동하는 연속스캐닝 기법을 검토하였고, 두께가 변화는 부재의 두께를 효과적으로 예측할 수 있었다.