• Title/Summary/Keyword: Scanning Image

Search Result 1,090, Processing Time 0.039 seconds

An Error Analysis of the 3D Automatic Face Recognition Apparatus (3D-AFRA) Hardware (3차원 안면자동분석 사상체질진단기의 Hardware 오차분석)

  • Kwak, Chang-Kyu;Seok, Jae-Hwa;Song, Jung-Hoon;Kim, Hyun-Jin;Hwang, Min-Woo;Yoo, Jung-Hee;Kho, Byung-Hee;Kim, Jong-Won;Lee, Eui-Ju
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.2
    • /
    • pp.22-29
    • /
    • 2007
  • 1. Objectives Sasang Contitutional Medicine, a part of the traditional Korean medical lore, treats illness through a constitutional typing system that categorizespeople into four constitutional types. A few of the important criteria for differentiating the constitutional types are external appearances, inner state of mind, and pathological patterns. We had been developing a 3D Automatic Face Recognition Apparatus (3D-AFRA) in order to evaluate the external appearances with more objectivity. This apparatus provides a 3D image and numerical data on facial configuration, and this study aims to evaluate the mechanical accuracy of the 3D-AFRA hardware. 2. Methods Several objects of different shapes (cube, cylinder, cone, pyramid) were each scanned 10 times using the 3D Automatic Face Recognition Apparatus (3D-AFRA). The results were then compared and analyzed with data retrieved through a laser scanner known for its high accuracy. The error rates were analyzed for each grid point of facial contour scanned with Rapidform2006 (Rapidform2006 is a 3D scanning software that collects grid point data for contours of various products and products and product parts through 3D scanners and other 3D measuring devices; the grid point data thusly acquired is then used to reconstruct highly precise polygon and curvature models). 3. Results and Conclusions The average error rate was 0.22mm for the cube, 0.22mm for the cylinder, 0.125mm for the cone, and 0.172mm for the pyramid. The visual data comparing error rates for measurement figures retrieved with Rapidform2006 is shown in $Fig.3{\sim}Fig.6$. Blue tendency indicates smaller error rates, while red indicates greater error rates The protruding corners of the cube display red, indicating greater error rates. The cylinder shows greater error rates on the edges. The pyramid displays greater error rates on the base surface and around the vertex. The cone also shows greater error around the protruding edge.

  • PDF

Vortical Etching Characteristics of SrBi$_2$Ta$_2$O$_9$ thin Films Depending on Ar/Cl$_2$ Ratios and RF/DC Power Densities (SrBi$_2$Ta$_2$O$_9$ 박막에 있어서 Ar/C1$_2$가스의 비율 및 RF/DC Power Density의 변화에 따른 수직 식각의 특성연구)

  • 황광명;이창우;김성일;김용태;권영석;심선일
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.8 no.3
    • /
    • pp.49-53
    • /
    • 2001
  • Vortical etching experiments of ($SrBi_2Ta_2O_9$)/Si thin films have been performed by using the inductively coupled plasma reactive ion etching (ICP-ME) apparatus. The purposes of these experiments are to get the effective area of vertical surface. Because this technology is very important to get good qualities of ferroelectric gate structure, capacitor and the minimum parasitic effects related to the excellent performances of the FRAM (Ferroelectric Random Access Memory) device. The reacting gases were Ar and $Cl_2$gases, and various $Ar/C1_2$flow ratios were used. The etching experiments were carried out at various RF powers such as 700, 700, 500W and at various DC powers such as 200, 150, 100, 50W, respectively. The maximum etch rate of $SrBi_2Ta_2O_9$/Si thin films was 1050 A/min at the $Ar/C1_2$ gas ratio of 20/16, RF power of 700 W and DC power of 200 W. From the SEM (scanning electron microscopy) image of the SBT thin films, the wall angle was as good as about $82^{\circ}$.

  • PDF

In vitro study of compressive fracture strength of Empress 2 crowns cemented with various luting agents

  • Kim Min-Ho;Yang Jae-Ho;Lee Sun-Hyung;Chung Hun-Young;Chang Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.260-272
    • /
    • 2001
  • All-ceramic restorations have had a more limited life expectancy than metal ceramic restorations because of their low strength. Their relatively lower strength and resistance to fracture have restricted the use of all-ceramic crowns to anterior applications where occlusal loads are lower. But there has been increasing interest in all-ceramic restorations because patients are primarily concerned with improved esthetics. Many efforts have been made to in prove the mechanical properties of dental ceramics. This study was designed to elucidate the influence of the luting agent on the strength of the Empress 2 crown (staining technique) cemented on human teeth. Seventy extracted human permanent molar teeth were chosen. Teeth were prepared for Empress 2 crowns with milling machine on a surveyor. A dental bur was placed in the mandrel that was positioned so that the long axis of the bur was perpendicular to the surveyor base. Dimensions of the Empress 2 crown preparation were $6^{\circ}$ taper on each side, $1.5{\pm}0.1mm$ shoulder margin, and 4mm crown height. The luting cements used in this study were as follow: 1. Uncemented 2. Zinc phosphate cements (Confi-Dental) 3. Conventional glass ionomer cement : Fuji 1 (GC) 4. Resin-modified glass ionomer cements : Fuji plus (GC) 5. Adhesive cements : Panavia F (Kuralay), Variolink II (Vivadent), Choice (Bisco). Fracture test using Instron. The crowns were loaded in compressive force to evaluate the effect of these cements on the breaking strength of these all-ceramic crowns. A steel ball with a diameter of 4mm was placed on the occlusal surface and load was applied to the steel ball by a cylindrical bolt with a crosshead speed of 0.5mm per minute until fracture occurred. The fractured surface was examined using Scanning Electron Microscopic Image (SEM) to discover the correlation between fracture strength and bonding capacity. Within the limitation of this in vitro study design, the results were as follows : 1. fomentations significantly increased the fracture resistance of Empress ceramic crowns compared to control. Uncemented (206.9 N): ZPC (812.9 N): Fuji 1 (879.5 N): Fuji Plus (937.7 N): Choice (1105.4 N): Variolink II (1221.1 N): Panavia F (1445.2 N). 2. Resin luting agent, treated by a silane bond enhancing agents, yielded a significant increase in fracture resistance. In some of the Panavia F group, a fracture extended into dentin. 3. According to SEM images of fractured Empress crowns, the stronger the bond at both interfaces(crown and die), the more fracture strength was acquired.

  • PDF

Evaluation of marginal leakage of bulk fill flowable composite resin filling with different curing time using micro-computed tomography technology (Bulk fill 유동성 복합레진의 변연 누출에서 다른 중합시간의 영향에 대해 마이크로시티를 이용한 평가)

  • Kim, Eun-Ji;Lee, Kyu-Bok;Jin, Myoung-Uk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.184-193
    • /
    • 2016
  • Purpose: To evaluate marginal leakage of bulk fill flowable composite resin filling with different curing time by using microcomputed tomography technology. Materials and Methods: 30 previously extracted human molars were randomly divided into 6 groups based upon restorative system and different curing time. Class II cavities (vertical slot cavities) were prepared. An individual metallic matrix was used to build up the proximal wall. The SonicFill or SureFil SDR flow was inserted into the preparation by using 1 bulk increment, followed by light polymerization for different curing times. The different exposure times were 20, 40, and 60 seconds. All specimens were submitted to 5,000 thermal cycles for artificial aging. Micro-CT scanning was performed by using SkyScan 1272. One evaluator assessed microleakage of silver nitrated solution at the resin-dentin interface. The 3D image of each leakage around the restoration was reconstructed with CT-Analyser V.1.14.4. The leakage was analyzed with the Mann-Whitney test. Results: Significant differences were observed between the light curing times, but no significant differences were found between the bulk fill composite resins. Increasing in the photoactivation time resulted in greater microleakage in all the experimental groups. Those subjected to 60 seconds of light curing showed higher microleakage means than those exposed for 20 seconds and 40 seconds. Conclusion: Increasing the photoactivation time is factor that may increase marginal microlekage of the bulk fill composite resins. Further, micro-CT can nondestructively detect leakage around the resin composite restoration in three dimensions.

MEASUREMENT OF MAXILLARY SINUS VOLUME FOR THE PLACEMENT OF GRAFT MATERIAL - A CASE CONTROL STUDY USING CT IMAGE (상악동 골이식술을 위한 이식재의 부피 측정 - CT를 이용한 환자 대조군 연구)

  • Kim, Hyung-Wook;Lee, Seul-Ki;Chung, Jae-An;Shin, Jin-Eob;Um, Yun-Sub;Kim, Ki-Young;Kim, Jong-Sik;Song, Yun-Jung;Hong, Soon-Min;Park, Jun-Woo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.5
    • /
    • pp.511-517
    • /
    • 2007
  • Purpose: The aim of this study is to determine whether a difference in the amount of bone graft material is needed between edentulous patients and dentulous patients and to calculate the amount of augmentation for a sinus lift procedure. Methods: 19 patients(20 sinuses) were included to measure maxillary sinus volume. Facial CT scanning was performed using MX 8000 IDT CT devices(Philips, USA). And it was used for IDLvm(The IDL Virtual Machine) 6.0, CT Volume Analyzer Ver 2.3 program to measure maxillary sinus volumes Results: At edentulous patients, volumes(mean${\pm}SD$) of the inferior portion of the sinuses were $0.56{\pm}0.13cm^3$(5mm height), $2.35{\pm}0.57cm^3$(10mm height), $4.85{\pm}1.10cm^3$(15mm height). At dentulous patients, volumes(mean${\pm}SD$) of the inferior portion of the sinuses were $0.41{\pm}0.18cm^3$(5mm height), $1.76{\pm}0.42cm^3$(10mm height), $3.80{\pm}0.84cm^3$ (15mm height). A significant correlation was found between augmentation height(5mm, 10mm, 15mm) and the calculated sinus volume.(p=0.027, p=0.018, p=0.044) Conclusions: A significant correlation was found between augmentation height(5mm, 10mm, 15mm) and the calculated sinus volume. Detailed preoperative knowledge of sinus lift augmentation volume is helpful in determining the appropriate amount of the bone graft material.

Surface Modification of Ba0.6Sr0.4TiO3 by Trimethylsilyl Chloride as a Silylation Agent (Trimethylsilyl Chloride를 Silylation Agent로 사용한 Ba0.6Sr0.4TiO3 나노입자의 표면개질 연구)

  • Lee, Chan;Han, Wooje;Park, Hyung-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.4
    • /
    • pp.127-132
    • /
    • 2019
  • In this study, barium strontium titanate (BSTO) with high dielectric perovskite structure was synthesized by liquid-solid solution synthesis and the surface was modified using trimethylsilyl chloride (TMCS) as a silylation agent. Silylation surface modification is a method of reacting -OH ligand on the surface of BSTO nanoparticles with Cl in TMCS to generate HCl and replacing the ligand on the surface of nanoparticles with -Si, -CH3. Silylation was optimized by varying the concentration of TMCS, and the structure of the silicon network was confirmed by Fourier-transform infrared spectroscopy. In addition, the crystallinity of BSTO nanoparticles was confirmed by X-ray diffractometer and the size of the nanoparticles was calculated using Scherrer equation. The field emission scanning electron microscopic image observed the change of the surface-modified BSTO particle size, and the contact angle measurement confirmed the hydrophobic property of the contact angle of 120.9° in the optimized nanoparticles. Finally, the surface-modified BSTO dispersion experiment in de-ionized water confirmed the hydrophobic degree of the nanoparticles.

LATEST RESULTS OF THE MAXI MISSION

  • MIHARA, TATEHIRO
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.559-563
    • /
    • 2015
  • Monitor of All-sky X-ray Image (MAXI) is a Japanese X-ray all-sky surveyer mounted on the International Space Station (ISS). It has been scanning the whole sky since 2009 during every 92-minute ISS rotation. X-ray transients are quickly found by the real-time nova-search program. As a result, MAXI has issued 133 Astronomer's Telegrams and 44 Gamma-ray burst Coordinated Networks so far. MAXI has discovered six new black holes (BH) in 4.5 years. Long-term behaviors of the MAXI BHs can be classified into two types by their outbursts; a fast-rise exponential-decay type and a fast-rise flat-top one. The slit camera is suitable for accumulating data over a long time. MAXI issued a 37-month catalog containing 500 sources above a ~0.6 mCrab detection limit at 4-10 keV in the region ${\mid}{b}{\mid}$ > $10^{\circ}$. The SSC instrument utilizing an X-ray CCD has detected diffuse soft X-rays extending over a large solid angle, such as the Cygnus super bubble. MAXI/SSC has also detcted a Ne emission line from the rapid soft X-ray nova MAXI J0158-744. The overall shapes of outbursts in Be X-ray binaries (BeXRB) are precisely observed with MAXI/GSC. BeXRB have two kinds of outbursts, a normal outburst and a giant one. The peak dates of the subsequent giant outbursts of A0535+26 repeated with a different period than the orbital one. The Be stellar disk is considered to either have a precession motion or a distorted shape. The long-term behaviors of low-mass X-ray binaries (LMXB) containing weakly magnetized neutron stars are investigated. Transient LMXBs (Aql X-1 and 4U 1608-52) repeated outbursts every 200-1000 days, which is understood by the limit-cycle of hydrogen ionization states in the outer accretion disk. A third state (very dim state) in Aql X-1 and 4U 1608-52 was interpreted as the propeller effect in the unified picture of LMXB. Cir X-1 is a peculiar source in the sense that its long-term behavior is not like typical LMXBs. The luminosity sometimes decreases suddenly at periastron. It might be explained by the stripping of the outer accretion disk by a clumpy stellar wind. MAXI observed 64 large flares from 22 active stars (RS CVns, dMe stars, Argol types, young stellar objects) over 4 years. The total energies are $10^{34}-10^{36}$ erg $s^{-1}$. Since MAXI can measure the spectrum (temperature and emission measure), we can estimate the size of the plasma and the magnetic fields. The size sometimes exceeds the size of the star. The magnetic field is in the range of 10-100 gauss, which is a typical value for solar flares.

Study of Sensor Technology Analysis and Site Application Model for 3D-based Global Modeling of Construction Field (건설 시공현장의 3D기반 광대역 모델링을 위한 Sensor 기술 분석과 향후 현장적용 모델 연구)

  • Kwon, Hyuk-Do;Koh, Min-Hyeok;Yoon, Su-Won;Kwon, Soon-Wook;Chin, Sang-Yoon;Kim, Yea-Sang
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.938-942
    • /
    • 2007
  • The importance of process improvement under construction has arisen from recent issue, lower productivity in the construction site. The various 3D modeling program is utilized in the procedure of construction as an alternative solution. However, it's still shortage of the consideration about a specific technical application. The purpose of the study in this paper is helpful to improve the productivity of construction site using 3D realization of constructing place as one of extensive modeling technologies, which leads to not only efficient management of construction site allowing people to check the real time situation in the place but also the revitalization of information flow about building process control and prgress, Therefore, I research into modeling algorithm and extensive construction site realization technology. 3D realization of building place would reduce the safety concerns by providing the real time information about construction site, and it could help to access easily to similar project through collecting and appling the database of sites. Furthermore it can be an opportunity to develop the procedure of production in construction industry and to upgrade the image of this field.

  • PDF

Edge-adaptive demosaicking method for complementary color filter array of digital video cameras (디지털 비디오 카메라용 보색 필터를 위한 에지 적응적 색상 보간 방법)

  • Han, Young-Seok;Kang, Hee;Kang, Moon-Gi
    • Journal of Broadcast Engineering
    • /
    • v.13 no.1
    • /
    • pp.174-184
    • /
    • 2008
  • Complementary color filter array (CCFA) is widely used in consumer-level digital video cameras, since it not only has high sensitivity and good signal-to-noise ratio in low-light condition but also is compatible with the interlaced scanning used in broadcast systems. However, the full-color images obtained from CCFA suffer from the color artifacts such as false color and zipper effects. These artifacts can be removed with edge-adaptive demosaicking (ECD) approaches which are generally used in rrimary color filter array (PCFA). Unfortunately, the unique array pattern of CCFA makes it difficult that CCFA adopts ECD approaches. Therefore, to apply ECD approaches suitable for CCFA to demosaicking is one of the major issues to reconstruct the full-color images. In this paper, we propose a new ECD algorithm for CCFA. To estimate an edge direction precisely and enhance the quality of the reconstructed image, a function of spatial variances is used as a weight, and new color conversion matrices are presented for considering various edge directions. Experimental results indicate that the proposed algorithm outperforms the conventional method with respect to both objective and subjective criteria.

RPC Model Generation from the Physical Sensor Model (영상의 물리적 센서모델을 이용한 RPC 모델 추출)

  • Kim, Hye-Jin;Kim, Jae-Bin;Kim, Yong-Il
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.11 no.4 s.27
    • /
    • pp.21-27
    • /
    • 2003
  • The rational polynomial coefficients(RPC) model is a generalized sensor model that is used as an alternative for the physical sensor model for IKONOS-2 and QuickBird. As the number of sensors increases along with greater complexity, and as the need for standard sensor model has become important, the applicability of the RPC model is also increasing. The RPC model can be substituted for all sensor models, such as the projective camera the linear pushbroom sensor and the SAR This paper is aimed at generating a RPC model from the physical sensor model of the KOMPSAT-1(Korean Multi-Purpose Satellite) and aerial photography. The KOMPSAT-1 collects $510{\sim}730nm$ panchromatic images with a ground sample distance (GSD) of 6.6m and a swath width of 17 km by pushbroom scanning. We generated the RPC from a physical sensor model of KOMPSAT-1 and aerial photography. The iterative least square solution based on Levenberg-Marquardt algorithm is used to estimate the RPC. In addition, data normalization and regularization are applied to improve the accuracy and minimize noise. And the accuracy of the test was evaluated based on the 2-D image coordinates. From this test, we were able to find that the RPC model is suitable for both KOMPSAT-1 and aerial photography.

  • PDF