• 제목/요약/키워드: ScanSAR

검색결과 28건 처리시간 0.022초

Evaluation of Clinical Usefulness of Radio-Frequency Power Limitation in Brain MRI of Patients with Deep Brain Stimulation (뇌심부자극술 시술환자의 뇌 자기공명영상에서 고주파 출력의 제한기준에 대한 임상적 유용성 평가)

  • Yeon, Kyoo-Jin;Chang, Young-Ae;Lee, Seung-Keun;Lee, Tae-Soo
    • Journal of Radiation Industry
    • /
    • 제11권3호
    • /
    • pp.139-144
    • /
    • 2017
  • To evaluation of clinical usefulness for B1+RMS limits, we compared image quality of Routine, Specific absorption rate (SAR) and Root mean square (RMS) protocol. 5 volunteers underwent Magnetic Resonance Imaging (MRI) scan of the brain using three different protocols. We draw Region of interest ROI in cortex, white matter, gray matter, putamen and thalamus of axial plan. Signal to noise ratio (SNR) were evaluated in each area and Contrast to noise ration (CNR) were evaluated between white matter and gray matter. Qualitative evaluation was used to score each ROI. B1+RMS is confirmed its usefulness compared to conventional SAR standard on the aspect of improvement of image quality, reduction of scan time and easy adjusting parameter.

Alternative Input Lower Weight Information Method Error to Reduce Specific Absorption Rate in MRI (자기공명영상 검사 시 환자정보의 체중을 낮게 입력하여 전자파흡수율을 감소시키는 대안의 오류)

  • Choi, Kwan-Woo
    • The Journal of the Korea Contents Association
    • /
    • 제20권2호
    • /
    • pp.472-477
    • /
    • 2020
  • The purpose of this study is to correct the error of lower weight input method as an alternative to reduce the specific absorption rate(SAR) in MRI. In order to prove that the SAR values not change according to the weight entered into the patient information, the 50kg phantom is placed in the coil and the input weight is changed from 10 to 100 in 10kg units to compare the SAR values. As a result, T1-weighted images had a SAR rate of 0.2W/kg and T2-weighted images had an average of 0.4W/kg. In conclusions, the SAR does not change according to the weight input by the technician before the scan, a lower weight when inputting patient information cannot be an alternative to reduce the SAR.

GMTI Two Channel Raw Data Processing and Analysis (GMTI 2채널 원시데이터 처리 및 분석)

  • Kim, So-Yeon;Yoon, Sang-Ho;Shin, Hyun-Ik;Youn, Jae-Hyuk;Kim, Jin-Woo;You, Eung-Noh
    • Korean Journal of Remote Sensing
    • /
    • 제34권6_1호
    • /
    • pp.847-855
    • /
    • 2018
  • GMTI (Ground Moving Target Indicator) is a kind of airborne radar function that is used widely in military applications to detect the moving targets on the ground. In this paper, GMTI signal processing technique was presented and its performance was verified using sum and difference channels raw data obtained by the captive flight test.

Forward Looking DPCA using Two Passive Antennas with Vertical Separation

  • Kim Man-Jo;Kho Bo-Yeon;Yoon Sang-Ho
    • Proceedings of the KSRS Conference
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.474-477
    • /
    • 2005
  • In tactical theater, it is crucial to detect ground moving targets and to locate them precisely. This problem can be resolved by using SAR (Synthetic Aperture Radar) sensors providing GMTI (Ground Moving Target Indication) capability. In general, to implement a robust GMTI sensor is not simple because of the strong competitions between target signals and clutter signals on the ground, and low speed of moving targets. Contrary to the case that a delay canceller is mostly suitable for ground surveillance radars, DPCA (Displaced Phase Centered Antenna) or STAP (Space Time Adaptive Processing) techniques have been adapted for GMT! function of modem airborne radars. In this paper, anew scheme of DPCA using two passive antennas with vertical separation is proposed, which also provides good clutter cancellation performance. The proposed scheme enables us to scan straight ahead of the carrying platform that is impossible with typical DPCA configuration. Simulations using various conditions have been performed to validate the proposed scheme, and the results are acceptable.

  • PDF

Monthly Variations of Surface Winds in the Korean Peninsula Sea Area and Typhoon Monitoring Using Microwave Remote Sensing (마이크로파 원격탐사에 의한 한반도 주변 해상풍의 월변동 특성 및 태풍 모니터링에 관한 연구)

  • Yang, Chan-Su;Jun, Ki-Cheon;Lehner, Susanne
    • Proceedings of KOSOMES biannual meeting
    • /
    • 해양환경안전학회 2006년도 추계학술발표회
    • /
    • pp.201-204
    • /
    • 2006
  • 태풍의 경우, 주요 자연재해 중의 하나로 태풍의 상황을 정확하게 파악하는 것은 기상예측의 정도를 높이고, 재해를 방지하는데 중요한 역할을 할 수 있다. 일반적으로 태풍의 동향을 감시하는데 있어, MTSAT 등의 기상위성이 주로 활용되고 있다. 근년 인공위성의 원격탐사를 이용하여 광범위의 해양에 대한 해상풍과 파랑의 관측이 가능하게 되었다. 본 연구에서는, 2000년 QuickSCAT위성에 의한 해상풍의 월변동 특성을 조사하고, 7월에 한반도에 영향을 준 태풍 카이탁내의 해상풍을 검토하였다. 추가로 2005 년 8월 30일의 태풍 탈림에 대해서 ENVISAT ASAR Scan SAR에 의한 해상풍 추출을 시도하였다. QuickSCAT 에 의한 풍향을 이용한 방법과 SAR 자체의 패턴을 이용한 방법이 비교되었다.

  • PDF

Design and Implementation of CTM for SAR Payload (위성 SAR 탑재체용 파형발생수신모듈 설계 및 제작)

  • Kim, Dong-Sik;Kim, Hyun-Chul;Yu, Kyung-deok;Heo, John;Woo, Jae-Choon;Lee, Sang-Gyu;Lee, Hyeon-Cheol;Ryu, Sang-Burm
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • 제50권2호
    • /
    • pp.119-125
    • /
    • 2022
  • In this paper, we present design, implementation and test results of CTM (Chirp Transceiver Module) EM (Engineering Model) for C-Band SAR (Synthetic Aperture Radar) Payload. The CTM is designed to operate dual frequency scan method that simultaneously operate two frequencies in each 50MHz bandwidth to achieve 120Km swath with 10m resolution at about 500Km altitude. The CTM used radiation tolerant RTG4 FPGA for space environment, and implemented with the Parallel DDS (PDDS) method which uses a small memory capacity compared to the memory-map method. Test results show high purity chirp signal generation and excellent IRF performance from received chirp signal after direct digital conversion.

JAXA'S EARTH OBSERVING PROGRAM

  • Shimoda, Haruhisa
    • Proceedings of the KSRS Conference
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.7-10
    • /
    • 2006
  • Four programs, i.e. TRMM, ADEOS2, ASTER, and ALOS are going on in Japanese Earth Observation programs. TRMM and ASTER are operating well, and TRMM operation will be continued to 2009. ADEOS2 was failed, but AMSR-E on Aqua is operating. ALOS (Advanced Land Observing Satellite) was successfully launched on $24^{th}$ Jan. 2006. ALOS carries three instruments, i.e., PRISM (Panchromatic Remote Sensing Instrument for Stereo Mapping), AVNIR-2 (Advanced Visible and Near Infrared Radiometer), and PALSAR (Phased Array L band Synthetic Aperture Radar). PRISM is a 3 line panchromatic push broom scanner with 2.5m IFOV. AVNIR-2 is a 4 channel multi spectral scanner with 10m IFOV. PALSAR is a full polarimetric active phased array SAR. PALSAR has many observation modes including full polarimetric mode and scan SAR mode. After the unfortunate accident of ADEOS2, JAXA still have plans of Earth observation programs. Next generation satellites will be launched in 2008-2012 timeframe. They are GOSAT (Greenhouse Gas Observation Satellite), GCOM-W and GCOM-C (ADEOS-2 follow on), and GPM (Global Precipitation Mission) core satellite. GOSAT will carry 2 instruments, i.e. a green house gas sensor and a cloud/aerosol imager. The main sensor is a Fourier transform spectrometer (FTS) and covers 0.76 to 15 ${\mu}m$ region with 0.2 to 0.5 $cm^{-1}$ resolution. GPM is a joint project with NASA and will carry two instruments. JAXA will develop DPR (Dual frequency Precipitation Radar) which is a follow on of PR on TRMM. Another project is EarthCare. It is a joint project with ESA and JAXA is going to provide CPR (Cloud Profiling Radar). Discussions on future Earth Observation programs have been started including discussions on ALOS F/O.

  • PDF

Effective of Body Temperature Increasing during Brain MRI scan (MRI 검사 시 체온상승 효과: 1.5 T vs 3.0 T)

  • Kim, Myeong Seong;Lee, Jongwoong;Jung, Jaeeun
    • Journal of the Korean Society of Radiology
    • /
    • 제11권1호
    • /
    • pp.49-54
    • /
    • 2017
  • As the Radiofrequency(RF) increases with the magnetic field strength, the wavelength of the RF excitation field becomes smaller, which leads to more the thermal effect in the human-body placed in the electric field. MRI scanner used was GE signa 1.5T, HDx 3.0T and Philips 3.0T with same routine clinical sequence protocol. Therefore temperature was measured before and after each scan. Taken the temperatures in the ear with ear infra-red type thermometer(Braun co). 3.0T were temperature increases more than $0.15^{\circ}C$ and GE 3.0T MRI equipment about $0.14^{\circ}C$ higher than the Philips 3.0T MRI(p<0.012). Psychogenic status was investigated by the survey respondents about their status can not just answer therefore, a little different from the expected. In our study of Thermal effect of clinical MRI with clinical protocol sequence, we found that the 3.0T in the body-temperature rise was greater than the 1.5T. Therefore, in clinical 3.0T examine the dangerous situation caused by the temperature rise occurred (burns, impaired thermoregulatory mechanism in patients with high-temperature damage, exhaustion occurs due to excessive sweating), not to appear the more watched the patient's condition with procedure.