• 제목/요약/키워드: Scan-based test

검색결과 210건 처리시간 0.033초

Laser Powder Bed Fusion 공정으로 제조된 Ti-6Al-4V 격자 구조물의 최적 설계 기법 연구 (A Study on the Optimal Design of Ti-6Al-4V Lattice Structure Manufactured by Laser Powder Bed Fusion Process)

  • 김지윤;우정민;손용호;김정호;이기안
    • 한국분말재료학회지
    • /
    • 제30권2호
    • /
    • pp.146-155
    • /
    • 2023
  • The Ti-6Al-4V lattice structure is widely used in the aerospace industry owing to its high specific strength, specific stiffness, and energy absorption. The quality, performance, and surface roughness of the additively manufactured parts are significantly dependent on various process parameters. Therefore, it is important to study process parameter optimization for relative density and surface roughness control. Here, the part density and surface roughness are examined according to the hatching space, laser power, and scan rotation during laser-powder bed fusion (LPBF), and the optimal process parameters for LPBF are investigated. It has high density and low surface roughness in the specific process parameter ranges of hatching space (0.06-0.12 mm), laser power (225-325 W), and scan rotation (15°). In addition, to investigate the compressive behavior of the lattice structure, a finite element analysis is performed based on the homogenization method. Finite element analysis using the homogenization method indicates that the number of elements decreases from 437,710 to 27 and the analysis time decreases from 3,360 to 9 s. In addition, to verify the reliability of this method, stress-strain data from the compression test and analysis are compared.

PET-CT에서 감쇠보정 영상과 비감쇠보정 영상을 통한 Metal Artifact 보정에 대한 고찰 (Metal artifact SUV estimation by using attenuation correction image and non attenuation correction image in PET-CT)

  • 김준;김재일;이홍재;김진의
    • 핵의학기술
    • /
    • 제20권2호
    • /
    • pp.21-26
    • /
    • 2016
  • 최근엔 대부분의 PET-CT영상의 감쇠보정은 많은 강점을 가지고 있는 CT를 기반으로 사용하고 있다. 하지만 CT 검사때 metal artifact가 발생하게 된다면, PET 영상에서 영향을 주게 된다. 이에 본 논문에서는 감쇠보정 영상의 count와 비감쇠보정 영상의 count의 비를 통하여 보정계수($e^{-{\mu}x}$)을 구하였고 이를 통해 측정 SUV에 대입하여 실제 SUV를 추정하는 방법에 대하여 고찰해보았다. 실험장비로는 본원에서 사용하고 있는 Biograph mCT S(40)_SIMENS을 촬영 장비로 이용하였고, phantom은 micro phantom을 사용하였다. 팬텀 실험방법은 micro phantom에 metal artifact를 발생시켜 촬영한 뒤 감쇠보정 영상과 비 감쇠보정 영상으로 재구성하였다. 그리고 SIMENS 사의 Sygo.via VA11A 프로그램을 이용 감쇠보정 영상과 비 감쇠보정 영상의 count를 측정하고 이를 통해 보정계수를 구하여 Metal artifact 발생 부위와 Metal artifact 발생 직전 부위의 보정계수를 비교 분석해 보았다. 임상영상에서는 본원에 내원한 환자 10명($66{\pm}15$세)의 데이터를 이용하여 여러 장기의 평균 보정계수를 계산하였고, Metal artifact가 발생한 연부조직의 보정계수와 metal artifact가 발생하기 직전의 연부조직의 보정계수를 비교 분석하였다. 분석결과 phantom 실험에서는 밝은 artifact 부분에서의 보정 계수는 Metal artifact가 발생하지 않은 부분에서의 보정계수보다 평균 12%증가 되게 나타났다. 어두운 artifact 부분에서의 보정계수는 발생하지 않은 부분에서의 보정계수보다 6% 감소 되게 나타났다. 또한 phantom 실험결과 본 논문에서 사용한 식을 이용한 추정 SUV가 실제 SUV와 유의미한 차이가 없다는 것을 확인 할 수 있었다. 임상영상에서는 normal 장기의 보정계수를 계산 하였고, 이를 이용한 각 장기의 평균 보정계수를 계산하여 그래프를 작성하였다. 그리고 이 결과 값을 통해 CT number가 큰 조직 일수록 보정계수도 커지는 상호 비례 관계를 확인 할 수 있었다. 또한 metal artifact시 밝은 artifact 부분의 연부조직 보정계수는 metal artifact가 발생 하지 않은 연부조직 보정계수에 비해 평균 20% 증가, 그리고 어두운 artifact 부분은 10% 감소된 것으로 나타났다. 그래프로 작성한 soft tissue 평균값과 비교 하였을 때는 metal artifact가 발생 하지 않은 연부조직에 비해 밝은 artifact 부위는 평균 19% 증가 어두운 artifact 부위는 평균 9% 감소 된 것으로 나타났다. 즉 경우에 따라 각 개인의 보정계수를 계산 할 필요 없이 그래프로 작성한 평균값을 간편하게 활용 할 수 있을 것으로 사료된다. 이와 같이 실험결과로 보아 본 논문에서 제시하였던 감쇠보정 영상과 비 감쇠보정 영상에서의 count의 비를 통해 metal artifact가 발생하지 않는 부위의 보정계수와 발생한 부위의 보정계수를 구하고, 이를 활용하여 측정 SUV에 대입하여 실제 SUV를 추정하는 방법 역시 metal artifact 발생 부위의 더 정확한 정량분석 위하여 고려 해볼 수 있는 대안이 될 수 있을 것이라 사료 된다.

  • PDF

99mTc-MAG3를 이용한 상대적 신장 기능 평가 시 신장 깊이에 따른 기하평균 적용의 유용성 평가 (Utility Evaluation on Application of Geometric Mean Depending on Depth of Kidney in Split Renal Function Test Using 99mTc-MAG3)

  • 이은별;이왕희;안성민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권2호
    • /
    • pp.199-208
    • /
    • 2016
  • $^{99}mTc-MAG_3$ 동적 신장 검사는 $^{99}mTc-MAG_3$를 이용하여 방사성 의약품이 신장에 섭취되고 배설되는 과정을 멈춤 없이 동적으로 영상화 하는 방법이다. 검사 시작 후 1~2.5분 사이 좌우 신장에서의 비율을 측정하여 상대적 신장기능비를 측정할 수 있으며, 총 신장 기능을 기준으로 상대적 신장기능비를 비율로 나타낼 수 있다. 본 연구는 일반적인 신장 검사 방법인 후면 검출기만 이용해 계수된 데이터로 구해진 상대적 신장기능비와 전면, 후면 검출기 모두로 계수한 뒤 기하평균을 이용해 얻어진 데이터로 구해진 상대적 신장기능비를 비교하여, 좌우 신장 깊이 차이가 상대적 신장기능비에 미치는 영향을 알아보고, 기하평균의 신장 깊이차에 따른 감쇠 보정 효과의 유용성에 대해 연구하고자 한다. 2015년 7월부터 2016년 2월 사이에 $^{99}mTc-MAG_3$ 동적 신장 검사를 시행한 33명의 환자(남자 13명, 여자 20명, 평균나이 44.66세, 범위 5세~70세, 평균키 160.40 cm, 평균 몸무게 55.40 kg)를 대상으로 하였다. 신장 깊이를 측정한 결과. 왼쪽 신장은 평균 65.82 mm, 오른쪽 신장은 71.62 mm로 나타났다. 33명의 환자들 중 30명의 환자에게서 전면과 후면 검출기로 계수하여 기하평균을 적용한 상대적 신장기능비가 후면 검출기로만 얻어진 정보를 가지고 구해진 상대적 신장기능비보다 깊게 위치한 신장의 비가 상승하고, 얕게 위치하고 있는 신장의 비가 떨어지는 결과가 나왔다. 깊게 위치하고 있는 신장과 검출기 사이의 감쇠가 보정된 결과라고 사료되며, 신장 혹은 신장 주변에 병변이 있는 경우, 척추의 기형, 이소 신장의 경우, 이식신장을 가지고 있는 환자 중 본래의 신장을 제거하지 않은 환자의 경우 등 좌우 신장의 깊이 차이가 나는 경우 깊게 위치하고 있는 신장의 비를 보정해 주어 기존에 일반적으로 시행되어지고 있는 검사 방법(후면 검출기 계수)과 비교했을 때, 정확한 상대적 신장기능비를 계산할 수 있을 것이라 사료된다.

한국 젊은 성인의 정규화된 아치 높이에 따른 발 유형 분석 (Analysis of Foot Type in Korean Young Adults Based on Normalized Arch Height)

  • 정도영
    • 한국전문물리치료학회지
    • /
    • 제27권3호
    • /
    • pp.199-205
    • /
    • 2020
  • Background: The classification of foot type can be commonly determined by the height of the media longitudinal arch. The normalized arch height (NAH) is defined as the ratio of navicular or instep heights to the foot length or instep length. Objects: This study investigated the relationships among foot characteristics, such as foot length (FL), instep length (IL), navicular height (NH), and instep height (IH), in Korean young adults. Also, the distribution of foot type based on calculated NAH was assessed. Methods: Three-dimensional foot scanning data of young adults aged 20 to 39 years (total: 1,978; 974 male, 1,004 female) were obtained from the Korea Technology Standards Institute, and used for analyses. NAH was calculated as the following: NH/FL, IH/FL, IH/IL, NH/IL. Spearman's rank order correlation was used to identify correlations among variables. The Mann-Whitney U-test and chi-square test were used to compare the sex differences in foot characteristics and distribution of foot type. Results: FL and IL showed a very high correlation (r = 0.94). The correlations between FL or IL and IH (r = 0.50-0.57) were greater than those between FL or IL and NH (r = 0.23-0.72). Males had significantly larger values than females (p < 0.001), and the frequency of pes planus was significantly higher in females than in males (χ2 = 50.09, p < 0.001). Based on the IH/IL index, the neutral foot, pes planus and pes cavus distributed by 16%, 78%, and 6% respectively. Conclusion: Our results on foot arch distribution could be used as basic data in clinical or footwear fields, and our data on differences in arch structure according to sex may facilitate understanding of why injury to the lower limbs differs between males and females.

여아 환자에서의 취약 X 증후군의 분자유전학적 진단 (Molecular diagnosis of fragile X syndrome in a female child)

  • 정선용;양정아;김현주
    • Journal of Genetic Medicine
    • /
    • 제5권1호
    • /
    • pp.41-46
    • /
    • 2008
  • 목 적 : 취약 X 증후군(fragile X syndrome)은 FMR1 유전자의 5' 비해독부위에 있는 CGG 3염기 반복의 확장에 의해 발생되는 유전성 질환이다. 방 법 : 본 연구에서는 임상 소견과 핵형분석에서 취약 X 증후군으로 진단 받은 여아 환자와 그 부모를 대상으로 Abbott Molecular Fragile X PCR Kit를 이용하여 CGG 3염기 영역을 PCR로 증폭하여 normal, premutation, full mutation의 CGG 반복의 유형을 확인하였으며, premutation과 normal allele의 경우에는 정확한 CGG 반복수를 분석하였다. 결 과 : 환자는 30회와 >200회의 CGG 3염기가 반복된 FMR1 대립유전자를 갖고 있는 것으로 확인되어 취약 X 증후군으로 진단되었다. 또한 환자의 어머니에서 30과 98회의 반복 allele을 확인함으로써, 이 환자의 full mutation allele은 모계의 premutation allele로부터 유래한 것임을 알 수 있었다. 결 론 : Abbott Molecular Fragile X PCR Kit를 사용한 진단방법은, 취약 X 증후군환자의 경우에서 통상적으로 시행되고 있는 PCR, MS-PCR, Southern blotting을 병행하는 방법에 비해 신속하고 정확한 분자유전학적 진단이 가능한 유용한 방법이라 생각된다.

  • PDF

한국인 20대 청년 인체분절의 관성특성에 관한 연구 (Biodynamic Characteristics of Korean Male in Twenties-Mass, Center of Mass and Moment of Inertia Characteristics of Body Segments)

  • 이영신;임현균;김철중
    • 대한기계학회논문집
    • /
    • 제18권8호
    • /
    • pp.1952-1966
    • /
    • 1994
  • The body segment parameters of twelve young male Korean were measured to compare with the results of foreign cadaver studies. A human body was assumed to have fourteen body segments. The mass of each segment was measured with a water immersion test and the mass center of a segment was determined on the balance platform by changing postures. In the case of Korean, because of the difference in body proportion, the mass center of whole-body is located further from the distal end of head(Korean : 44.9% vs. Caucasian : 41.2%), and the mass center of each segment also located in different proportional locations. The existing regression equations, which can estimate segment mass based upon the anthropometric dimensions, estimates segment mass (the mass of shank) for Korean with 13% error. Therefore, it is not recommended to estimate the mass, and the moment of inertia of body segment of Korean based on the existing equations. However, the density information of body constituents was similar enough to apply it to Korean density. It was validated by the comparison between the results of the direct immersion method and 3-dimensional volume reconstruction of segment form the cross sectional images of CT-scan. The average body density measured form twelve subjects was $1.035{\;}kg/m^3$ and showed deceasing trendency.

Efficient Experimental Design for Measuring Magnetic Susceptibility of Arbitrarily Shaped Materials by MRI

  • Hwang, Seon-ha;Lee, Seung-Kyun
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권3호
    • /
    • pp.141-149
    • /
    • 2018
  • Purpose: The purpose of this study is to develop a simple method to measure magnetic susceptibility of arbitrarily shaped materials through MR imaging and numerical modeling. Materials and Methods: Our 3D printed phantom consists of a lower compartment filled with a gel (gel part) and an upper compartment for placing a susceptibility object (object part). The $B_0$ maps of the gel with and without the object were reconstructed from phase images obtained in a 3T MRI scanner. Then, their difference was compared with a numerically modeled $B_0$ map based on the geometry of the object, obtained by a separate MRI scan of the object possibly immersed in an MR-visible liquid. The susceptibility of the object was determined by a least-squares fit. Results: A total of 18 solid and liquid samples were tested, with measured susceptibility values in the range of -12.6 to 28.28 ppm. To confirm accuracy of the method, independently obtained reference values were compared with measured susceptibility when possible. The comparison revealed that our method can determine susceptibility within approximately 5%, likely limited by the object shape modeling error. Conclusion: The proposed gel-phantom-based susceptibility measurement may be used to effectively measure magnetic susceptibility of MR-compatible samples with an arbitrary shape, and can enable development of various MR engineering parts as well as test biological tissue specimens.

On-orbit test simulation for field angle dependent response measurement of the Amon-Ra energy channel instrument

  • 성세현;김석환;류동옥;홍진석
    • 천문학회보
    • /
    • 제37권2호
    • /
    • pp.211.1-211.1
    • /
    • 2012
  • The on-orbit test simulation for predicting the instrument directional responsivity was conducted by the Monte Carlo based integrated ray tracing (IRT) computation technique and analytic flux-to-signal conversion algorithms. For the on-orbit test simulation, the Sun model consists of the Lambertian scattering sphere and emitting spheroid rays, the Amon-Ra instrument is a two-channel including a broadband scanning radiometer (energy channel) and an imager with ${\pm}2^{\circ}$ FOV (visible channel). The solar radiation produced by the Sun model is directed to the instrument viewing port and traced through the dual channel optical train. The instrument model is rotated on its rotation axis and this gives a slow scan of the Sun model over the full field of view. The direction of the incident lights are fed with scanned images obtained from the visible channel instrument. The instrument responsivity was computed by the ratio of the incident radiation input to the instrument output. In the radiometric simulation, especially, measured BRDF of the 3D CPC was used for scattering effects on radiometry. With diamond turned 3D CPC inner surface, the anisotropic surface scattering model from the measured data was applied to ray tracing computation. The technical details of the on-orbit test simulation are presented together with field-of-view calibration plan.

  • PDF

원유 세균수 검사장비의 정도관리를 위한 표준시료의 개발 및 평가 (Development and evaluation of standard samples for quality control of automated total bacterial counter in raw milk)

  • 강혜정;김진환;변영섭;이하나;이혜영;김지현;홍세림;김하영;윤순식;문진산
    • 한국동물위생학회지
    • /
    • 제43권3호
    • /
    • pp.147-154
    • /
    • 2020
  • Standard samples were prepared for this study, and applied for BactoScanTM and BactoCountTM in order for quality control evaluation for total bacterial count in raw milk. Accordingly, the preparation of two lots of standard samples for quality control were lyophilized, which contain Lactobacillus lactis. The standard samples were prepared into three different levels of bacterial counts, those were Low 30,000~40,000, Medium 70,000~90,000, High 150,000~220,000 CFU/mL, respectively. Then, the proficiency tests were performed in total 19 laboratories for measuring total bacterial counts. The total bacterial counts in the standard samples showed 37~42, 82~105, 214~240 CFU/mL in the first lot, and it showed 30~36, 67~75, 131~163 CFU/mL in the second lot in low, medium and high levels, respectively. Based on these results, the absolute values of z-scores of six standard samples in 18 laboratories were ≤2, which means the samples are satisfactory. However, z-score in one laboratory was ≤3, which means the sample is questionable. Using two standard samples, the correlation between BactoScanTM and BactoCountTM was 0.9982, which means the results of total bacterial count measurement of both equipment were equivalent. Therefore, the standard samples manufactured in this study for quality control of total bacterial count using BactoScanTM and BactoCountTM in the raw milk could be applied to proficiency tests.

시공방법에 따른 다웰바 시공상태 분석 (Analysis of Dowel Bar Placement Accuracy with Construction Methods)

  • 이재훈;김형배;권순민;권오선
    • 한국도로학회논문집
    • /
    • 제9권2호
    • /
    • pp.101-114
    • /
    • 2007
  • 줄눈 콘크리트 포장에서 다웰바는 하중을 전달해주는 역할과 단차를 감소시켜줌으로써 궁극적으로 포장의 공용성을 높여주는 역할을 수행한다. 그러나 다엘바의 시공상태가 불량할 경우에는 오히려 줄눈잠김 등을 유발하여 스폴링이나 균열을 초래하여 공용성을 떨어뜨릴 수 있다. 다웰바의 시공방법은 다웰바 어셈블리 시공방법과 다웰바자동삽입기를 이용한 시공방법이 있는데 국내에서는 어셈블리를 이용한 시공방법만이 사용되고 있다. 본 연구에서는 비파괴 조사장비인 MIT-SCAN2를 이용하여 한국도로공사 시험도로에 시공된 다웰바자동삽입 시공구간과 다웰바 어셈블리 시공구간에 대한 다웰바 시공상태 및 Joint Score와 Running Ave. Joint Score를 산출하여 비교 분석해 보았다. 그 결과, 다웰바자동삽입 시공방법이 다웰바 어셈블리 시공방법에 비해 깊이변화, 수평/수직엇갈림에서 매우 우수한 시공상태를 보이는 것으로 나타났으며 줄눈잠김의 위험 또한 다웰바 어셈블리 시공방법에 비해 매우 낮다는 점을 발견했다. 또한 국내 다웰바 어셈블리 시공방법의 문제점을 다웰바 어셈블리의 생산, 보관, 시공 측면에서 분석하였다. 문제점 분석을 토대로 다웰바의 체어형태, 고정방법을 개선하여 시험시공을 수행한 결과, 모든 시공상태 항목이 개선되었음을 알 수 있었으며, 특히 수평/수직엇갈림이 크게 개선되어 줄눈잠김에 대한 위험성이 줄어듦을 알 수 있었다.

  • PDF