• Title/Summary/Keyword: Scan technique

Search Result 595, Processing Time 0.024 seconds

Developmental Genetic Analysis of Avian Primordial Germ Cells and the Application to Poultry Biotechnology

  • Kagami, H.
    • Korean Journal of Poultry Science
    • /
    • v.28 no.2
    • /
    • pp.135-142
    • /
    • 2001
  • A novel sterategy has been established to determine the origin of the Primordial Germ Cells (PGCs) in avian embryos directly and the developmental fate of the PGCs for the application to Poultry biotechnology. Cells were removed from 1) the centre of area pellucida, 2) the outer of area pellucida and 3) the area opaca of the stage X blastoderm (Eyal-Giladi & Kochav, 1976). When the cells were removed from the centre of area pellucida, the mean number of circulating PGCs in blood was significantly decreased in the embryo at stage 15 (Hamburger & Hamilton, 1951) as compared to intact embryos. When the cells were replenished with donor cells, no reduction in the PGCs number was observed. The removal of cells at the outer of area pellucida or at the area opaca had no effect on the number of PGCs. In case, another set of the manipulated embryos were cultured ex vivo to the hatching and reared to the sexual maturity, the absence of germ cells and degeneration of seminiferous tubules was observed in resulting chickens derived from the blastoderm in which the cells were removed from the centre of the area pellucida. It was concluded that the avian Primordial Germ cells are originated at the center of area pellucida. Developmental ability of the cells to differentiate into somatic cells and germ cells in chimeras were analyzed. Somatic chimerism was detected as black feather attributed from donor cells. Molecular identification by use of female - specific DNA was performed. It was confirmed that the donor cells could be differentiated into chimeric body and erythrocytes. Donor cells retained the ability to differentiate into germline in chimeric gonads. More than 70% of the generated chimeras transmitted donor derived gametes to their offspring indicating that the cells at the center of area pellucida had the high ability to differentiate into germ cells. A molecular technique to identify germline chimerism has been developed by use of gene scan analysis. Strain specific DNA fragments were amplified by the method. It would be greatly contributed for the detection of germline chimerism. Mixed- sex chimeras which contained both male and female cells were produced to investigate the developmental fate of male and female cells in ovary and testes. The sex combinations of donor and recipient of the resulting chimeras were following 4 pairs; (1) chimeras (ZZ/ZZ) produced by a male donor (ZZ) and a male recipient (ZZ), (2) chimeras (ZW/ZW) produced by a female donor (ZW) and a female recipient (ZW), (3) chimeras (ZZ/ZW) Produce by a male donor (ZZ) and a female recipient (ZW), (4) chimeras (ZW/ZZ) produced by a female donor (ZW) and a male recipient (ZZ). It was found that genetically male avian germ cells could differentiate into functional ova and that genetically female germ cells can differentiate into functional spermatozoa in the gonad of the mixed- sex chimeras. An ability for introduction of exogenous DNA into the PGCs from stage X blastoderms were analyzed. Two reporter genes, SV-$\beta$gal and RSV-GFP, were introduced into the PGCs. Expression of bacterial/gal was improved by complexing DNA with liposome detectedcc in 75% of embryos at 3 days embryos. At the embryos incubated for 1 day, expression of the GFP was observed all the embryos. At day 3 of incubation, GFP was detected in about 70% of the manipulated embryos. In case of GFP, expression of the transgene was detected in 30 %e of the manipulated embryos. These results suggested that the cells is one of the most promising vectors for transgenesis. The established strategy should be very powerfull for application to poultry biotechnology.

  • PDF

Comparative Volume Measuring Methods According to the Tumor Characters in PET/CT (PET/CT 검사에서 종양의 특성에 따른 체적 측정 방법 비교)

  • Choi, Yong Hoon;Ban, Yung Gak;Oh, Shin Hyun;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.52-58
    • /
    • 2016
  • Purpose Recent retrospective studies are being actively conducted to analyze the survival of patients with SUVmax, MTV, TLG, such as information from a variety of PET originating. However, there is no clear way is difficult to accurately measure the volume of the tumor may be the difference between the caster is raised. In this study, to evaluate compare the volume measuring methods according to the characteristics of the tumor. Materials and Methods 18F-saline to fill the NEMA IEC Body Phantom insert the volume of balance and imbalance in phantom were acquired to the Biograph truepoint 40 (Siemens medical system, Germany) PET/CT scanner. The ratio of the volume and Background was acquired as 3.0, 5.0, 8.0, 18, 40. Clinical patients were randomly selected 120 people in staging patients with cancer of the digestive system from the year 2010 until the year 2014. Measurement methods were used a 40% threshold, 50% threshold and gradient segmentation technique, i.e. PET EDGE. Five years of experience of the two radio-technologist and one doctor was measured by repeated three times. Analysis methods were Intraclass correlation coefficient and Pearson correlation. Results In Phantoms, the 40% threshold method gave the best concordance between measured and actual volumes (r = 0.992, 0.997). In clinical patient outcome agreement between observers EDGE it is as high as 0.999 (CI: 0.998-0.999). And there were no statistical significance of the difference between the measurements (P = 0.620). 40% threshold method showed the best correlation between the measurements (r = 0.953). Increasing the ratio of tumor to background decreased the influence of a measuring method. Conclusion How to measure volume of the tumor in the patient was clinically most useful is 50% and the lowest impact on the characteristics of the tumor. Therefore, to reduce the background of the patients in PET/CT scan, it should be required research and effort.

  • PDF

Locates the Sunken Ship 'Dmitri Donskoi' using Marine Geophysical Survey Techniques in Deep Water (지구물리 탐사기법을 이용한 심해 Dmitri Donskoi호 확인)

  • Yoo, Hai-Soo;Kim, Su-Jeong;Park, Dong-Won
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.104-117
    • /
    • 2004
  • Dmitri Donskoi, which went down during the Russo-Japanese War occurred 100 years ago, was found by using geophysical exploration techniques at the 400 m water depth of submarine valley off Jeodong of Ulleung Island. In the submarine area with the rugged seabed topography and volcanic seamounts, in particular, the reliable seabed images were acquired by using the mid-to-shallow Multibeam exploration technique The strength of corrosion (causticity) of the sunken Donskoi, measured by the electrochemical method, decreased to 2/5 compared with the original strength.

  • PDF

The Clinical Outcome of Pulmonary Thromboendarterectomy for the Treatment of Chronic Pulmonary Thromboembolism (만성 폐동맥 색전증 환자에서의 폐동맥 내막절제술의 임상적 결과)

  • Bang, Jeong-Hee;Woo, Jong-Soo;Choi, Pil-Jo;Jo, Gwang-Jo;Park, Kwon-Jae;Kim, Si-Ho;Yie, Kil-Soo
    • Journal of Chest Surgery
    • /
    • v.43 no.3
    • /
    • pp.254-259
    • /
    • 2010
  • Background: Diagnosing chronic pulmonary embolism at an early stage is difficult because of the patient’s nonspecific symptoms. This condition is not prevalent in Korea, and in fact, there have been only a few case reports on this in the Korean medical literature. We analyzed the surgical outcome of performing pulmonary thromboendarterectomy in patients with chronic pulmonary embolism. Material and Method: The study subjects included those patients who underwent surgery for chronic pulmonary embolism from 1996 to 2008. For making the diagnosis, echocardiography, chest CT and a pulmonary perfusion scan were performed on the patients who complained of chronic dyspnea. Result: Pulmonary endarterectomy was performed as follows: by incision via a mid-sternal approach (7 patients); by incision via a left posterolateral approach (1 patient); using the deep hypothermic circulatory arrest technique (4 patients); under ventricular fibrillation (3 patients); and under cardioplegic arrest (1 patient). The postoperative systolic pulmonary artery blood pressure significantly decreased from a preoperative value of $78.9{\pm}14.5\;mmHg$ to $45.6{\pm}17.6\;mmHg$ postoperatively (p=0.000). The degree of tricuspid regurgitation was less than grade II after surgery. Two patients died early on, including one patient who had persistent pulmonary hypertension without improvement and right heart failure. Conclusion: Patients who have chronic pulmonary embolism are known to have a poor prognosis. However, we think that early surgical treatment along with making the proper diagnosis before the aggravation of right heart failure can help improve the quality of a patient's life.

Evaluation of Absorbed Dose and Skin Dose with MDCT Using Ionization Chamber and TLD (이온 전리함 및 TLD 법을 이용한 Multi-Detector Computed Tomography의 흡수선량 및 체표면 선량 평가)

  • Jeon, Kyung Soo;Oh, Young Kee;Baek, Jong Geun;Kim, Ok Bae;Kim, Jin Hee;Choi, Tae Jin;Jeong, Dong Hyeok;Kim, Jeong Kee
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.35-40
    • /
    • 2013
  • Recently, the uses of Multi-Detector Computed Tomography (MDCT) for radiation treatment simulation and planning which is used for intensity modulated radiation therapy with high technique are increasing. Because of the increasing uses of MDCT, additional doses are also increasing. The objective of this study is to evaluate the absorbed dose of body and skin undergoing in MDCT scans. In this study, the exposed dose at the surface and the center of the cylindrical water phantom was measured using an pencil ionization chamber, 30 cc ionization chamber and TL Powder. The results of MDCT were 31.84 mGy, 33.58 mGy and 32.73 mGy respectively. The absorbed dose at the surface showed that the TL reading value was 33.92 mGy from MDCT. These results showed that the surface dose was about 3.5% from the MDCT exposure higher than a dose which is located at the center of the phantom. These results mean that the total exposed dose undergoing MDCT 4 times (diagnostic, radiation therapy planning, follow-up et al.), is about 14 cGy, and have to be considered significantly to reduce the exposed dose from CT scan.

Stereotactic Target Point Verification in Actual Treatment Position of Radiosurgery (방사선수술시 두개내 표적의 정위적좌표의 치료위치에서의 확인)

  • Yun, Hyong-Geun;Lee, Hyun-Koo
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.403-409
    • /
    • 1995
  • Purpose : Authors tried to enhance the safety and accuracy of radiosurgery by verifying stereotacitc target point in actual treatment position prior to irradiation. Materials and Methods : Before the actual treatment, several sections of anthropomorphic head phantom were used to create a condition of unknown coordinates of the target point. A film was sandwitched between the phantom sections and punctured by sharp needle tip. The tip of the needle represented the target point. The head phantom was fixed to the stereotactic ring and CT scan was done with CT localizer attached to the ring. After the CT scanning, the stereotactic coordinates of the target point were determined. The head phantom was secured to accelerator's treatment couch and the movement of laser isocenter to the stereotactic coordinates determined by CT scanning was performed using target positioner. Accelerator's anteroposterior and lateral portal films were taken using angiographic localizers. The stereotactic coordinates determined by analysis of portal films were compared with the stereotactic coordinates previously determined by CT scanning. Following the correction of discrepancy the head phantom was irradiated using a stereotactic technique of several arcs. After the irradiation, the film which was sandwitched between the phantom sections was developed and the degree of coincidence between the center of the radiation distribution with the target point represented by the hole in the film was measured. In the treatment of the actual patients, the way of determining the stereotactic coordinates with CT localizers and angiograuhic localizers was the same as the phantom study. After the correction of the discrepancy between two sets of coordinates, we proceeded to the irradiation of the actual patient. Results : In the phantom study, the agreement between the center of the radiation distribution and the localized target point was very good. By measuring optical density profiles of the sandwitched film along axes that intersected the target point, authors could confirm the discrepancy was 0.3 mm. In the treatment of an actual patient, the discrepancy between the stereotactic coordinates with CT localizers and angiographic localizers was 0.6 mm. Conclusion : By verifying stereotactic target point in actual treatment position prior to irradiation, the accuracy and safety of streotactic radiosurgery procedure were established.

  • PDF

A Patterns of Care Study of the Various Radiation Therapies for Prostate Cancer among Korean Radiation Oncologists in 2006 (Patterns of Care Study를 위한 2006년 한국 방사선종양학과 전문의들의 전립선암 방사선치료원칙 조사연구)

  • Kim, Jin-Hee;Kim, Jae-Sung;Ha, Sung-Whan;Shin, Seong-Soo;Park, Won;Cho, Jae-Ho;Suh, Chang-Ok;Oh, Young-Taek;Shin, Sei-Won;Kim, Jae-Chul;Jang, Ji-Young;Nam, Taek-Keun;Choi, Young-Min;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.96-103
    • /
    • 2008
  • Purpose: To conduct a nationwide academic hospital patterns of the practice status and principles of radiotherapy for prostate cancer. The survey will help develop the framework of a database of Korean in Patterns of Case Study. Materials and Methods: A questionnaire about radiation treatment status and principles was sent to radiation oncologists in charge of prostate cancer treatment at thirteen academic hospitals in Korea. The data was analyzed to find treatment principles among the radiation oncologists when treating prostate cancer. Results: The number of patients with prostate cancer and treated with radiation ranged from 60 to 150 per academic hospital in Seoul City and 10 to 15 outside of Seoul City in 2006. The primary diagnostic methods of prostate cancer included the ultrasound guided biopsy on 6 to 12 prostate sites(mean=9), followed by magnetic resonance imaging and a whole body bone scan. Internal and external immobilizations were used in 61.5% and 76.9%, respectively, with diverse radiation targets. Whole pelvis radiation therapy(dose ranging from 45.0 to 50.4 Gy) was performed in 76.9%, followed by the irradiation of seminal vesicles($54.0{\sim}73.8$ Gy) in 92.3%. The definitive radiotherapy doses were increased as a function of risk group, but the range of radiation doses was wide(60.0 to 78.5 Gy). Intensity modulated radiation therapy using doses greater than 70 Gy, were performed in 53.8% of academic hospitals. In addition, the simultaneous intra-factional boost(SIB) technique was used in three hospitals; however, the target volume and radiation dose were diverse. Radiation therapy to biochemical recurrence after a radical prostatectomy was performed in 84.6%; however, the radiation dose was variable and the radiation field ranged from whole pelvis to prostate bed. Conclusion: The results of this study suggest that a nationwide Korean Patterns of Care Study is necessary for the recommendation of radiation therapy guidelines of prostate cancer.

Acute Cerebral Infarction in a Rabbit Model: Perfusion and Diffusion MR Imaging (가토의 급성 뇌경색에서 관류 및 확산강조 자기공명영상)

  • Heo Suk-Hee;Yim Nam-Yeol;Jeong Gwang-Woo;Yoon Woong;Kim Yun-Hyeon;Jeong Young-Yeon;Chung Tae-Woong;Kim Jeong;Park Jin-Gyoon;Kang Heoung-Keun;Seo Jeong-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.116-123
    • /
    • 2003
  • Purpose : The present study was undertaken to evaluate the usefulness of cerebral diffusion (DWI) and perfusion MR imaging (PWI) in rabbit models with hyperacute cerebral ischemic infarction. Materials and Methods : Experimental cerebral infarction were induced by direct injection of mixture of Histoacryl glue, lipiodol, and tungsten powder into the internal cerebral artery of 6 New-Zealand white rabbits, and they underwent conventional T1 and T2 weighted MR imaging, DWI, and PWI within 1 hour after the occlusion of internal cerebral artery. The PWI scan for each rabbit was obtained at the level of lateral ventricle and 1cm cranial to the basal ganglia. By postprocessing using special imaging software, perfusion images including cerebral blood volume (CBV), cerebral blood flow (CBF), and mean transit time (MTT) maps were obtained. The detection of infarcted lesion were evaluated on both perfusion maps and DWI. MTT difference time were measured in the perfusion defect lesion and symmetric contralateral normal cerebral hemisphere. Results : In all rabbits, there was no abnormal signal intensity on T2WI. But on DWI, abnormal high signal intensity, suggesting cerebral infarction, were detected in all rabbits. PWI (rCBV, CBF and MTT map) also showed perfusion defect in all rabbits. In four rabbits, the calculated square of perfusion defect in MTT map is larger than that of CBF map and in two rabbits, the calculated size of perfusion defect in MTT map and CBF map is same. Any rabbits do not show larger perfusion defect on CBF map than MTT map. In comparison between CBF map and DWI, 3 rabbits show larger square of lesion on CBF map than on DWI. The others shows same square of lesion on both technique. The size of lesion shown in 6 MTT map were larger than DWI. In three cases, the size of lesion shown in CBF map is equal to DWI. But these were smaller than MTT map. The calculated square of lesion in CBF map, equal to that of DWI and smaller than MTT map was three. And in one case, the calculated square of perfusion defect in MTT map was largest, and that of DWI was smallest. Conclusion : DWI and PWI may be useful in diagnosing hyperacute cerebral ischemic infarction and in e-valuating the cerebral hemodynamics in the rabbits.

  • PDF

The Analysis of the Need Rate of Shunt and the Outcome in Hydrocephalus Following SAH - Relationship between the Outcome and the Duration, Daily and Total Amount of CSF Drainage at EVD - (자발성 지주막하출혈 후 발생하는 수두증에 대한 단락술의 필요성 및 예후에 관한 분석 - 뇌실외배액술의 기간, 일일배액량 및 총배액량과 예후관계 -)

  • Lee, Won Chang;Choi, Chang Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup1
    • /
    • pp.99-107
    • /
    • 2001
  • Objective : Hydrocephalus and vasospasm are the common complications following subarachnoid hemorrhage (SAH). In spite of development of perioperative management and operative technique, hydrocephalus cause neurological deficit and poor prognosis. Usually CSF drainage procedure(external ventricular drainage(EVD) or shunt) is needed in hydrocephalus following SAH. The aim of this study was to investigate whether the need for shunting and the outcome after shunting in hydrocephaus following SAH can be related to the duration, daily and total amount of cerebrospinal fluid(CSF) drainage at EVD. Material and Method : IVH is one of several factors which cause hydrocephalus. In this retrospective study, firstly we investigated the incidence of IVH in total cases and frequency of IVH according to aneurysmal site and then prognosis of IVH following SAH. Among 629 patients with SAH, hydrocephalus was diagnosed by CT scan and symptoms. And then those 102 hydrocephalus following SAH were divided into two groups which were hydrocephalus with IVH group and without IVH group. In these two groups, we investigated and compared the incidence of hydrocephalus in all case, frequency of hydrocephalus according to aneurysmal site, the outcome according to H-H grade on admission and the need rate of shunt, etc. Of those hydrocephalus, 100 EVD procedures were done. The duration, daily and total amount of CSF drainage at EVD were investigated. Fifty cases expired during EVD was excluded. We analyzed whether the need rate of shunt and the final outcome after shunting can be related to IVH, the duration and daily and total amount of CSF drainage. Result : The incidence of hydrocephalus following SAH was 20%(with IVH group ; 64%, without IVH group ; 11%). As H-H grade on admission was better, the outcome of hydrocephalus was also better. The mortality rate of hydrocephalus with IVH was 64% which was higher than 40% that of hydrocephalus without IVH. The need rate of shunt in all cases of hydrocephalus following SAH was 20%, but those with IVH group excluding expired patients before shunt was 40%. This was very similar to 41% of the need rate of shunt in hydrocephalus without IVH. The total amount of CSF drainage was statistically related to the need rate of shunt(total amount : need rate of shunt/<1000cc : 15%, 1000-2000cc : 40%, >2000cc : 50%). The duration and daily amount of CSF drainage were not statistically related to the need rate of shunt, but as daily amount of CSF drainage was more and duration was longer, the need rate of shunt was increased(daily amount : need rate of shunt /<100cc : 16%, 100-200cc : 25%, >200cc : 40%//duration : need rate of shunt/<1week : 8%, 1-2weeks : 30%, >2weeks : 47%), and also the final outcome after shunting was poor. Especially the total amount of CSF drainage was significant related to the final outcome after shunting(total amount : GOS/<1000cc : I&II(3/4), 1000-2000cc : II(2/4), III(2/4), >2000cc : III&IV(6/7)). Conclusion : This study revealed that the incidence and mortality rate of hydrocephalus following SAH were influenced by IVH. So SAH associated IVH has the higher incidence of hydrocephalus and poor outcome. As the CSF drainage amount was more and duration of drainage was longer, the need rate of shunt was increased and the final outcome after shunting was poor. Especially the total amount of CSF drainage were strongly related to the need rate of shunt and the outcome after shunting.

  • PDF

Comparison of mDixon, T2 TSE, and T2 SPIR Images in Magnetic Resonance Imaging of Lumbar Sagittal Plane (요추 시상면 자기공명 영상검사에서 mDixon과 T2 TSE, T2 SPIR 영상의 비교 연구)

  • Jung, Da-Bin;Lee, Hae-Kag;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.927-933
    • /
    • 2021
  • The purpose of this study was to compare and analyze the differences in scan time, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in the third lumbar vertebral region including the back fat, spinal cord, and cerebrospinal fluid using the mDixon, T2 TSE, and T2 spectral pre-saturation with inversion-recovery (SPIR) techniques. With the factors affecting the SNR fixed, the lumbar sagittal plane images of 30 adults were compared on mDixon, T2 TSE, and T2 SPIR imaging tests. The test times for mDixon, T2 TSE, and T2 SPIR were 115 seconds, 60 seconds, and 60 seconds, respectively. The mDixon T2 images showed higher SNR than the T2 TSE images at the third lumbar vertebral region (p<0.05), lower SNR in the back fat and cerebrospinal fluid (p<0.05) areas, and comparable SNR in the spinal cord (p>0.05). The CNR between the third lumbar vertebral area and back fat was higher in the mDixon T2 images, and the CNR of the cerebrospinal fluid and spinal cord images was higher in the T2 TSE images (p<0.05). The mDixon T2 FS images CNR was lower for the 3rd lumbar vertebral body region and back fat than the T2 SPIR images, and higher for the spinal cord and cerebrospinal fluid images (p<0.05). The CNR between the third lumbar body and back fat areas was higher in the mDixon T2 FS images (p<0.05), and there was no difference in the CNR in the images of the cerebrospinal fluid and the spinal cord (p>0.05). It is difficult to determine whether the mDixon technique is superior to the conventional T2 TSE and T2 SPIR techniques in terms of test time, SNR, and CNR. This study was confined to patients with simple lower back pain and was limited by controlled experimental conditions. Studies using clinically applied protocols are warranted in the future.