• Title/Summary/Keyword: Scan technique

Search Result 594, Processing Time 0.029 seconds

Evaluation of MR Based Respiratory Motion Correction Technique in Liver PET/MRI Study (Liver PET/MRI 검사 시 MR 기반 호흡 움직임 보정 방법의 유용성 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 2018
  • Purpose Respiratory motion during PET/MRI acquisition may result in image blurring and error in measurement for volume and quantification of lesion. The aim of this study was to evaluate changes of quantitative accuracy, tumor size and image quality by applying MR based respiratory motion correction technique (MBRMCT) using integrated PET/MR scanner. Materials and Methods Data of 30 patients (aged $62.5{\pm}10.2y$) underwent $^{18}F-FDG$ liver PET/MR (Biograph mMR 3.0T, Siemens) study were collected. PET listmode data for 7 minutes was simultaneously acquired with maximum average gate (MAG), minimum time gate (MTG) and non gate (NG) T1 weighted MR images. Gated PET reconstruction was performed using mu-maps generated from MAG and MTG by setting 35% of efficiency window. Maximum SUV ($SUV_{max}$), peak SUV ($SUV_{peak}$), tumor size and full width at half maximum (FWHM) in the z-axis direction of MAG, MTG and NG PET images were evaluated. Results Compared to NG, mean $SUV_{max}$ and $SUV_{peak}$ were increased in MAG 13.15%(p<0.0001), 8.66%(p<0.0001), MTG 13.27%(p<0.0001), 8.80%(p<0.0001) and mean tumor size and FWHM were decreased in MAG 14.47%(p<0.0001), 15.49%(p=0.0004), MTG 14.89%(p<0.0001), 15.79%(p=0.0003) respectively. Mean $SUV_{max}$ and $SUV_{peak}$ of MTG were increased by 0.07%(p=0.8802), 0.13%(p=0.7766). Mean tumor size and FWHM of MTG were decreased by 0.49%(p=0.2786), 0.36%(p=0.2488) compared to MAG. There was no statistically significant difference between MAG and MTG which increase total scan time for about 7 and 2 minutes. Conclusion SUV, accuracy of tumor size and spatial resolution were improved in both of MAG and MTG by applying MBRMCT without installing additional hardware in liver PET/MR study. More accurate information can be provided with the increase of 2 minutes scan time if applying MTG of MBRMCT to various abdominal PET/MR studies affected by respiratory motion.

The Effect of PET Scan Time on the Off-Line PET Image Quality in Proton Therapy (양성자 치료에서 영상 획득 시간에 따른 Off Line PET의 효율성 검증)

  • Hong, Gun-Chul;Jang, Joon-Yung;Park, Se-Joon;Cha, Eun-Sun;Lee, Hyuk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.74-79
    • /
    • 2017
  • Purpose Proton therapy can deliver an optimal dose to tumor while reducing unnecessary dose to normal tissue as compared the conventional photon therapy. As proton beams are irradiated into tissue, various positron emitters are produced via nuclear fragmentation reactions. These positron emitters could be used for the dose verification by using PET. However, the short half-life of the radioisotopes makes it hard to obtain the enough amounts of events. The aim of this study is to investigate the effect of off-line PET imaging scan time on the PET image quality. Materials and Methods The various diameters of spheres (D=37, 28, 22 mm) filled with distilled water were inserted in a 2001 IEC body phantom. Then proton beams (100 MU) were irradiated into the center of the each sphere using the wobbling technique with the gantry angle of $0^{\circ}$. The modulation widths of the spread out bragg peak were 16.4, 14.7 and 9.3 cm for the spheres of 37, 28 and 22 mm in diameters respectively. After 5 min of the proton irradiation, the PET images of the IEC body phantom were obtained for 50 min. The PET images with different time courses (0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min) were obtained by dividing the frame with a duration of 10 min. In order to evaluate the off-line PET image quality with the different time courses, the contrast-to-noise ratio (CNR) of the PET image calculated for each sphere. Results The CNRs of the sphere (D=37 mm) were 0.43, 0.42, 0.40, 0.31 and 0.21 for the time courses of 0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min respectively. The CNRs of the sphere (D=28 mm) were 0.36, 0.32, 0.27, 0.19 and 0.09 for the time courses of 0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min respectively. The CNR of 37 mm sphere was decreased rapidly after 30 min of the proton irradiation. In case of the spheres of 28 mm and 22 mm, the CNR was decreased drastically after 20 min of the irradiation. Conclusion The off-line PET imaging time is an important factor for the monitoring of the proton therapy. In case of the lesion diameter of 22 mm, the off-line PET image should be obtained within 25 min after the proton irradiation. When it comes to small size of tumor, the long PET imaging time will be beneficial for the proton therapy treatment monitoring.

  • PDF

The Analysis of Amplitude and Phase Image for Acoustic Microscope Using Quadrature Technique (쿼드러춰 방식에 의한 초음파현미경의 진폭과 위상영상 분석)

  • Kim, Hyun;Jun, Kye-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.55-61
    • /
    • 1999
  • In this study, we have constructed the acoustic microscope using quadrature technique and analyzed the relative variation of image intensity and the quality of image by reconstructing the amplitude and phase image for surface defects with tiny hight variation. In this experiment, we have constructed the scanning acoustic microscope using the focused transducer with 3㎒ center frequency and the quadrature detector. And we have fabricated aluminum samples with round defects whose depth is different and reconstructed the amplitude and phase images for the samples. One sample has round defects with 2㎜ diameter and 100㎛ depth and the other has round defects with 4㎜ diameter and 5㎜ depth. In the result of line scanning for the sample with 100㎛ round defects, it has been shown that the variation rate of amplitude image intensity is 7% and the variation rate of phase image intensity is 89%. The phase image has better contrast than amplitude image for the sample. In contrast to this, the amplitude image has better contrast than phase image for the sample with 5㎜ depth's defects. Accordingly there is big difference between amplitude image and phase image for depth variation of defects whose boundary is 1 wavelength. Consequently the acoustic microscope using quadrature detector can be evaluated efficiently more than using envelope detector, for detecting defects which have height variation less than 1 wavelength. And also the phase image and the amplitude image can be used for detecting defects of tiny height variation with complimentary relation.

  • PDF

Understanding on MR Perfusion Imaging Using First Pass Technique in Moyamoya Diseases (Moyamoya 질환에서 1차 통과기법을 이용한 자기공명관류영상의 이해)

  • Ryu, Young-Hwan;Goo, Eun-Hoe;Jung, Jae-Eun;Dong, Kyung-Rae;Choi, Sung-Hyun;Lee, Jae-Seung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.27-31
    • /
    • 2010
  • The purpose of this study was to investigated the usefulness of MR perfusion image comparing with SPECT image. A total of pediatric 30 patients(average age : 7.8) with Moyamoya disease were performed MR Perfusion with 32 channel body coil at 3T from March 01, 2010 to June 10, 2010. The MRI sequences and parameters were as followed : gradient Echo-planar imaging(EPI), TR/TE : 2000ms/50ms, FA : $90^{\circ}$, FOV : $240{\times}240$, Matrix : $128{\times}128$, Thickness : 5mm, Gap : 1.5mm. Images were obtained contrast agent administrated at a rate of 1mL/sec after scan start 10s with a total of slice 1000 images(50 phase/1 slice). It was measured with visual color image and digitize data using MRDx software(IDL version 6.2) and also, it was compared of measurement with values of normal and abnormal ratio to analyze hemodynamic change, and a comparison between perfusion MR with technique using Warm Color at SPECT examination. On MR perfusion examination, the color images from abnormal region to the red collar with rCBV(relative cerebral blood volume) and rCBF(relative cerebral blood flow) caused by increase cerebral blood flow with brain vascular occlusion in surrounding collateral circulation advancement, the blood speed relatively was depicted slowly with blue in MTT(Mean Transit Time) and TTP(Time to Peak) images. The region which was visible abnormally from MR perfusion examination visually were detected as comparison with the same SPECT examination region, would be able to confirm the identical results in MMD(Moyamoya disease)judgments. Hymo-dynamic change in MR perfusion examination produced by increase and delay cerebral blood flow. This change with digitize data and being color imaging makes enable to distinguish between normal and abnormal area. Relatively, MR perfusion examination compared with SPECT examination could bring an excellent image with spatial resolution without radiation expose.

  • PDF

The Analysis of Free Flap (유리 조직 이식의 분석)

  • Choi, Sang-Mook;Hong, Sung-Bum;Chung, Chan-Min;Suh, In-Seock
    • Archives of Reconstructive Microsurgery
    • /
    • v.5 no.1
    • /
    • pp.35-45
    • /
    • 1996
  • After transplantation of groin free flap was sucessed by the Daniel and Taylor in 1973, the reconstruction of plastic surgery was extensive and universal due to rapidly developement of anatomic study of the donor site and technique of microvascular surgery. The free tissue transfers is possible to be early activity and rehabilitation by one stage operation. It currently available allow transfer of specific tissue quality as bone, muscle, nerve to achieve a functional and cosmetic result as well as the most favorable secondary defect. But free flaps require critical, skillful technique and lengthy operating time. Also it has disadvantage of donor site morbity at the large tissue transfer. Authors were transferred with 107 cases in 103 patients from May 1987 to June 1996, and then we analysed free tissue transfer to acquire more increased sucess rate, satisfactory functional and cosmetic results. The sexual distribution was male prominent in 79 cases(76.7%), female in 24(23.3%) and age was variable distribution from 3 to 76 years old. The cause of defects was most prevalent in trauma of traffic and industrial accident in 51 cases(49%). The common recipient site were lower extremities in 47 cases(43.9%), upper extremities in 28 cases(26.5%), head and neck in 25 cases(23.4%), and trunk in 7 cases(6.5%). The type of transfer were free skin flaps in 46 cases(43%), free muscle or musculocutaneous flaps in 31 cases(29%), free vasculized or osteocutaneous flaps in 10 cases(9.3%), and specilized free flaps in 20 cases(18.7%). The anastomosis of artery was end to end anastomosis in 94 cases(87.9%), end to side anastomosis in 13 cases(12.1%) and all vein was end to end anastomosis. The number of anastomosed vessels were one artery one vein in 62 cases(57.9%), one artery two vein in 45 cases(42.1%) and vein graft was performed only one case. The postoperative mornitoring were used with temperature, color of flap, capillary refilling time, ultrasonogram, bone scan, doppler, and endoscopy. The reexploration was performed in 9 cases(8.4%), and then flap was loss in 3 cases(2.8%). Accordingly overall success rate was 97.2%. The postoperative complication was early vascular occlusion, hematoma, partial necrosis and late bulkiness, scarring, color dismatch etc. Therefore, free tissue transfer is the preferred method of treatment, even through conventional local and distant flaps are available.

  • PDF

Immunoscintigraphy of Colorectal and Other Gastrointestinal Cancers with Radioactive Monoclonal Antibodies to CEA and CA 19-9 (대장직장암 및 기타 소화기암에서의 단세포군항체를 이용한 방사면역신티그라피의 진단)

  • Jang, Dae-Hwan;Choi, Duck-Joo;Lee, Bum-Woo;Park, Won;Han, Chang-Soon;Kim, Hak-San;Kim, Chong-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.22 no.1
    • /
    • pp.83-92
    • /
    • 1988
  • The cocktails of two $^{131}I$ labeled Monoclonal antibody (MCAB) (Anti CA 19-9 F$(ab')_2$ + Anti CEA $F(ab')_2$ fragment), which react specially, with human gastrointestinal cancers, were administered to 10 patients with colorectal (7), stomach(2) and pancreas(1) cancer for scintigraphic detection. All patients were known or postoperatively recurrent cases, and serum tumor markers, CA 19-9 and CEA, were measured with immunoradiometric assay, just before immunoscintigraphy (ISG). The tumor marker's level in serum is not correlated with positive tumor uptake in ISG. The sensitivity and specificity of ISG in detection of 21 tumor sites, based on surgery, CT, ultrasonography and pathology, were 90.5% and 100% One case of colon cancer showed gall bladder metastasis, which was neglected on CT study. Tumor/non tumor uptake ratio of radiolabelled antibody were progressively increased from day 3 to day 7 during study. We summerized as follows 1) The use of cocktails of CEA and CA 19-9 MCAB $F(at')_2$ increased sensitivity and specificity in ISG. 2) Delayed imaging (later than 5 days) increases sensitivitv and specificity due to exclusion of nonspecific iodine accumulation in stomach and lung. 3) Second tracer technique is essential for anatomical landmark by use of a double isotope scan, but subtraction technique, a possible source of artifacts, is no longer necessory when delayed imaging is performed. 4) It may be possible to use two MCAB cocktails of CA 19-9 and CEA in Radioimmunodetection of stomach and pancreas cancer. In conclusion, ISG using MCAB cocktails, $F(ab')_2$ fragment of anti CA 19-9 and Anti CEA, provide additional opportunity for tumor localization and detection of colorectal and other G-I cancer, such as stomach and pancreas.

  • PDF

Location Generalization Method of Moving Object using $R^*$-Tree and Grid ($R^*$-Tree와 Grid를 이용한 이동 객체의 위치 일반화 기법)

  • Ko, Hyun;Kim, Kwang-Jong;Lee, Yon-Sik
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.2 s.46
    • /
    • pp.231-242
    • /
    • 2007
  • The existing pattern mining methods[1,2,3,4,5,6,11,12,13] do not use location generalization method on the set of location history data of moving object, but even so they simply do extract only frequent patterns which have no spatio-temporal constraint in moving patterns on specific space. Therefore, it is difficult for those methods to apply to frequent pattern mining which has spatio-temporal constraint such as optimal moving or scheduling paths among the specific points. And also, those methods are required more large memory space due to using pattern tree on memory for reducing repeated scan database. Therefore, more effective pattern mining technique is required for solving these problems. In this paper, in order to develop more effective pattern mining technique, we propose new location generalization method that converts data of detailed level into meaningful spatial information for reducing the processing time for pattern mining of a massive history data set of moving object and space saving. The proposed method can lead the efficient spatial moving pattern mining of moving object using by creating moving sequences through generalizing the location attributes of moving object into 2D spatial area based on $R^*$-Tree and Area Grid Hash Table(AGHT) in preprocessing stage of pattern mining.

  • PDF

Blood Vessel Strain Imaging Using Linear Array Transducer (선형 트랜스듀서를 이용한 혈관 변형률 영상법)

  • Ahn, Dong-Ki;Jeong, Mok-Kun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.880-890
    • /
    • 2010
  • The intrasvascular ultrasound (IVUS) imaging technique is used to diagnose cerebrovascular diseases such as stroke. Recently, elasticity imaging methods have been investigated to diagnose blood clots attached to blood vessel intima. However, the IVUS imaging technique is an invasive method that requires a transducer to be inserted into blood vessel. In this paper, strain images are obtained of blood clots attached to blood vessel intima with data acquired from outside the blood vessel using a linear array transducer. In order to measure the displacement of blood vessel accurately, experimental data are acquired by steering ultrasound beams so that they can intersect the blood vessel wall at right angles. The acquired rf data are demodulated to the baseband. The resulting complex baseband signals are then processed by an autocorrelation algorithm to compute the blood vessel movement and thereby produce strain image. This proposed method is verified by experiments on a plastic blood vessel mimicking phantom. The efficacy of the proposed method was verified using a home-made blood vessel mimicking phantom. The blood vessel mimicking phantom was constructed by making a 6 mm diameter hollow cylinder inside it to simulate a blood vessel and adhering 2 mm thick soft plaque to the inner wall of the hollow cylinder. The RF data were acquired using a clinical ultrasound scanner (Accuvix XQ, Medison, Seoul. Korea) with a 7.5 MHz linear array transducer by steering ultrasound beams in steps of $1^{\circ}$ from $-40^{\circ}$ to $40^{\circ}$ for a total of 81 angles. Experimental results show that the plaque region near the blood vessel wall is softer than background tissue. Although the imaging region is restricted due to the limited range of angles for which scan lines are perpendicular to the wall, the feasibility of strain imaging is demonstrated.

Development of an Automatic 3D Coregistration Technique of Brain PET and MR Images (뇌 PET과 MR 영상의 자동화된 3차원적 합성기법 개발)

  • Lee, Jae-Sung;Kwark, Cheol-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Park, Kwang-Suk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.5
    • /
    • pp.414-424
    • /
    • 1998
  • Purpose: Cross-modality coregistration of positron emission tomography (PET) and magnetic resonance imaging (MR) could enhance the clinical information. In this study we propose a refined technique to improve the robustness of registration, and to implement more realistic visualization of the coregistered images. Materials and Methods: Using the sinogram of PET emission scan, we extracted the robust head boundary and used boundary-enhanced PET to coregister PET with MR. The pixels having 10% of maximum pixel value were considered as the boundary of sinogram. Boundary pixel values were exchanged with maximum value of sinogram. One hundred eighty boundary points were extracted at intervals of about 2 degree using simple threshold method from each slice of MR images. Best affined transformation between the two point sets was performed using least square fitting which should minimize the sum of Euclidean distance between the point sets. We reduced calculation time using pre-defined distance map. Finally we developed an automatic coregistration program using this boundary detection and surface matching technique. We designed a new weighted normalization technique to display the coregistered PET and MR images simultaneously. Results: Using our newly developed method, robust extraction of head boundary was possible and spatial registration was successfully performed. Mean displacement error was less than 2.0 mm. In visualization of coregistered images using weighted normalization method, structures shown in MR image could be realistically represented. Conclusion: Our refined technique could practically enhance the performance of automated three dimensional coregistration.

  • PDF

One Anchor Double Fixation (OADF) Technique for Arthroscopic Bony Bankart Repair (두가닥의 봉합사를 가진 봉합나사못을 이용한 새로운 관절경적 골성 방카르트 병변 봉합술)

  • Choi, Eui-Sung;Park, Kyoung-Jin;Kim, Yong-Min;Kim, Dong-Soo;Shon, Hyun-Chul;Cho, Byung-Ki;Bae, Seung-Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2010
  • Purpose: The aim of this study was to evaluate the usefulness of arthroscopic Bony Bankart repair using a One Anchor Double Fixation Technique. Materials and Method: Seventeen patients with a Bony Bankart lesion were treated using the One Anchor Double Fixation Technique (OADF Technique). There were 13 males and 4 females. The average age was 24 years (range 17-42). The average follow-up period was 22.3 months. One 3.0 mm suture anchor with doubly loaded sutures was inserted into the glenoid rim. One suture strand was passed the around the small bony fragment and tied first. Another suture strand was passed through the capsule and tied over the bony fragment. The result was measured using Rowe's evaluation index & KSS score. The glenoid defect & bony fragment were measured by 3D-CT scan. Results: Rowe's evaluation index on the final follow-up showed an overall improvement from an average of 54 (range, 23-71) to 83.4 (range 71-90). Of the 17 cases, 13 were excellent, 3 were good, and 1 was fair. KSS scores showed improvement from an average of 71 (range 49-82) to 92.5 (range 82-94). There were no cases where pain continued to the final follow-up, and no cases being re-dislocated during the follow-up period. For six cases, we confirmed the bony healing of the bony Bankart lesion by CT. Conclusion: Bony Bankart lesion repair using this new method achieves excellent clinical results with low recurrence rates and is considered another choice for bony Bankart lesions.