• Title/Summary/Keyword: Scan technique

Search Result 594, Processing Time 0.031 seconds

An Efficient Ultrasonic SAFT Imaging for Pulse-Echo Immersion Testing

  • Hu, Hongwei;Jeong, Hyunjo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.2
    • /
    • pp.84-90
    • /
    • 2017
  • An ultrasonic synthetic aperture focusing technique (SAFT) using a root mean square (RMS) velocity model is proposed for pulse-echo immersion testing to improve the computational efficiency. Considering the immersion ultrasonic testing of a steel block as an example, three kinds of imaging were studied (B-Scan, SAFT imaging based on ray tracing technology and RMS velocity). The experimental results show that two kinds of SAFT imaging have almost the same imaging performance, while the efficiency of RMS velocity SAFT imaging is almost 25 times greater than the SAFT based on Snell's law.

Acute Spinal Epidural Hematoma Following Unilateral Laminectomy for Bilateral Decompression

  • Lee, Dong-Yeob;Lee, Sang-Ho;Jang, Jee-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.1
    • /
    • pp.35-37
    • /
    • 2006
  • We present a case of acute spinal epidural hematoma[EDH] following unilateral laminectomy for bilateral decompression[ULBD]. A 45-year-old male presented with severe multi-level spinal stenosis underwent ULBD on the left side at the L2-3 and L3-4 level. Five hours after operation, paraparesis developed along with severe bilateral buttock pain. The CT scan showed an acute spinal EDH at the L2-3 level. The acute spinal EDH was successfully decompressed after emergency decompressive surgery with performing an additional laminectomy on the contralateral side at the L2-3 level. Although ULBD is an effective minimally invasive surgical technique for treating spinal stenosis, the possibility of acute spinal EDH should be kept in mind, as happened in our case.

Preparation of nano composite metal-oxide electrode and its application for superrcapacitor (나노복합산화물 전극의 제조 및 수퍼커패시터로써의 응용)

  • Kim, Hong-Il;Lee, Ju-Won;Kim, Sang-Gil;Yuk, Gyung-Chang;Park, Soo-Gil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.801-804
    • /
    • 2002
  • Electrochemical capacitors are becoming attractive energy storage systems particularly for applications involving high power requirements such as hybrid systems consisting of batteries and electrochemical capacitors for electric vehicle propulsion. Both of amorphous cobalt oxide and manganese dioxide were prepared by sol-gel process reported in our previous work. Nanostructured supramolecular oligomer of 1,5-diaminoanthraquinone(DAAQ) coated metal oxides were successfully prepared by electrochemical oxidation from an acidic non-aqueous medium. We established process parameters of the technique for the formation of nano-structured materials. Furthermore, improved the capacitive properties of the nano structured metal oxide electrodes using controlled solution chemistry. $CoO_2$ and $MnO_2$-based composite electrode showed relatively good electrochemical behaviors in acidic electrolyte system with respect to specific capacity and scan rate dependency.

  • PDF

A study on the sensitivity analysis of processing parameters for the laser surface hardening treatment (레이저 표면 경화처리 긍정변수의 민감도 해석에 관한 연구)

  • 이세환;양영수
    • Proceedings of the KWS Conference
    • /
    • 2000.10a
    • /
    • pp.260-263
    • /
    • 2000
  • A methodology is developed and many used to evaluate the response sensitivity of the thermal systems to variations in their design parameters. Technique for computing the sensitivity of temperature distributions to changes in processing parameters needed for deciding the more effective laser input parameters for laser surface hardening treatment are considered. In this study, a state equation governing the heat flow in laser surface treatment is analyzed using a three-dimensional finite element method and sensitivity data of the processing parameter obtained using a direct differentiation method applied for sensitivity analysis. The interesting processing parameter is taken as the laser scan velocity and characteristic beam radius( $r_{b}$) of the sensitivity of the temperature T versus v and $r_{b}$ is analyzed. And these sensitivity results obtained in another parameters are fixed condition. To verifying the numerical analysis results, hardened layer dimensions (width and depth) of the numerical analysis compared with the results of an experimental data.ata.

  • PDF

A Study on the Curvature Correction in Laser Scanner (레이저 주사 장치의 곡률 보정에 관한 연구)

  • Yun, N.I.;Kim, N.;Park, H.K.
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1986.10a
    • /
    • pp.194-197
    • /
    • 1986
  • In this paper, for the curvature correction on the scanning plane in laser scanning system, aberration correction method using holographic optical element is suggested. Holoens is selected as a type of holographic zone plate which has aberration correction property. And hologram recording condition is analyzed to find fo property. This hololens is implemented by computer-generated hologram technique. Laser scanning system is organized using desinged hololens and scanning properties of this system are investigated. Using this method optical system structure in laser scanning system can be simplified satisfying both scan linearity and field flatness.

  • PDF

Novel LCD's and novel LCD manufacturing;A new world of LCDs opened up by Photo-Rubbing

  • Yokoyama, Hiroshi;Kimura, Masayuki
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1601-1604
    • /
    • 2006
  • A novel photo-alignment scheme using normally incident periodically intensity-modulated UV light has been developed and demonstrated to efficiently yield a stable pretilt angle of nematic liquid crystals by single exposure. The scheme, referred to as the "photo-rubbing", consists in unidirectional scan of the intensity-modulated UV light over the photo-alignment film, which causes asymmetrical photo-reactions in the film. We show here its successful application to multi-domain alignment processing. Thanks to the normal incidence, the photo-rubbing removes the instrumental disadvantages of the conventional oblique incidence technique, thereby providing a true practical solution for photo-alignment.

  • PDF

Preparation of Boron Doped Fullerene Film by a Thermal Evaporation Technique using Argon Plasma Treatment and Its Electrochemical Application

  • Arie, Arenst Andreas;Jeon, Bup-Ju;Lee, Joong-Kee
    • Carbon letters
    • /
    • v.11 no.2
    • /
    • pp.127-130
    • /
    • 2010
  • Boron doped fullerene $C_{60}$ ($B:C_{60}$) films were prepared by the thermal evaporation of $C_{60}$ powder using argon plasma treatment. The morphology and structural characteristics of the thin films were investigated by scanning electron microscope (SEM), Fourier transform infra-red spectroscopy (FTIR) and x-ray photo electron spectroscopy (XPS). The electrochemical application of the boron doped fullerene film as a coating layer for silicon anodes in lithium ion batteries was also investigated. Cyclic voltammetry (CV) measurements were applied to the $B:C_{60}$ coated silicon electrodes at a scan rate of $0.05\;mVs^{-1}$. The CV results show that the $B:C_{60}$ coating layer act as a passivation layer with respect to the insertion and extraction of lithium ions into the silicon film electrode.

Fabrication and Characterization of ${LiMn_2}{O_4}$ Cathode for Lithium Rechargeable Battery by R.F.Magnetron Sputtering (R.F. Magnetron Sputtering을 이용한 리튬이차전지 정극용 ${LiMn_2}{O_4}$의 제조 및 특성)

  • 우태욱;손영국
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.6
    • /
    • pp.552-558
    • /
    • 2000
  • LiMn2O4 thin fiolm cathodes for Li-ion secondary battery were fabricated by r.f. magnetron sputtering technique. As-deposited films were amorphous. A spinel structure could not be obtained LiMn2O4 films by in-situ thermal annealing. After post thermal annealing over $700^{\circ}C$ in oxygen atmosphere, LiMn2O4 films prepared above 100 W r.f. power could be crystallized into a spinel structure. The electrochemical property of the LiMn2O4 film cathodes was tested in a Li/1 M LiClO4 in PC/LiMn2O4 cell. From cyclic voltammetry at scan rate of 2mV/sec of 2.5~4.5V, LiMn2O4 electrode prepared by post annealing at 75$0^{\circ}C$ showed good initial capacity. LiMn2O4 electrode prepared by post annealing at 80$0^{\circ}C$ showed the best crycling performance.

  • PDF

Dual Contrast EPI by Use of a Key Hole Technique

  • Jung, Kwan-Jin
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.113-113
    • /
    • 2001
  • Purpose: In the gradient echo EPI the conventional T2*-weighted image is poor in signal as well distorted by the field inhomogeneity. By acquiring a proton density image in addition to th T2*-weighted image at the same scan, the fMRI processing can be improved. Method: The central region of the k space is acquired twice at different time points after th RF pulse while acquiring the other regions onc as described in Fig. 1. In Fig. 1 the segment numbers are chronological. Then, we can get two images of different contrast by interleaving th central region in the k space as done in the dua contrast FSE.

  • PDF

Hemodynamically Induced Aneurysm-mimicking Findings at Anterior Communicating (A-com) Artery Area due to Anatomical Variation on 3D-TOF MRA

  • 강원석;정태섭;심용운;유병규;박인국
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.133-133
    • /
    • 2001
  • Purpose: To determine the relationship between anatomical variation at A-com. artery area an hemodynamically induced aneurysm-mimicking findings on 3D-TOF MRA clinically a experimentally. Method: Sixty-two patients who had no aneurysm at A-com artery on DSA were evalua with MRA. MRA was performed with 1.5T MR machine(Vision, Siemens). Scan parameters o MRA included TR/TE/FA=30/6.4/25$\psi$$\circledR$˙¡, 512*192 of matrix with MIP technique. The occurrence of signal defect at shoulder area of bifurcated A-com artery on MRA was evalua for the relationship between the symmetricity of bilateral ACA and the patency of A-c artery. DSA images were acquired at both ICA and VA. To analyze hemodynamical facto of signal defect, experimental studies of MRA and DSA were peformed with elastic silic phantom using conducting pulsatile pump. We also compared the results with those o computational fluid dynamics(CFD).

  • PDF