• Title/Summary/Keyword: Scan technique

Search Result 594, Processing Time 0.034 seconds

A Non-Scan Design-For-Test Technique for RTL Controllers/Datapaths based on Testability Analysis (RTL 회로를 위한 테스트 용이도 기반 비주사 설계 기법)

  • Kim, Sung-Il;Yang, Sun-Woong;Kim, Moon-Joon;Park, Jae-Heung;Kim, Seok-Yoon;Chang, Hoon
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.30 no.2
    • /
    • pp.99-107
    • /
    • 2003
  • This paper proposes a design for testability (DFT) and testability analysis method for register-transfer level (RTL) circuits. The proposed method executes testability analysis - controllability and observability - on the RTL circuit and determines the insertion points to enhance the testability. Then with the associated priority based on the testability, we insert only a few of the test multiplexers resulting in minimized area overhead. Experimental results shows a higher fault coverage and a shorter test generation time than the scan method. Also, the proposed method takes a shorter test application time required.

Treatment of Nasal Bone Fracture without Nasal Packing (비강 충전 없는 비골골절의 치료)

  • Lee, Dong Chan;Eun, Seok Chan;Heo, Chan Yeong;Baek, Rong Min;Minn, Kyung Won
    • Archives of Craniofacial Surgery
    • /
    • v.9 no.1
    • /
    • pp.8-11
    • /
    • 2008
  • Purpose: The majority of nasal bone fractures have been managed by routine procedure of closed reduction, intranasal packing or intranasal Kirschner wire (K-wire) splinting. But it leaves rooms for many complaints from patients such as pain, rhinorrhea and nasal obstructioon. Another option is, of course, no packing at all. The study was initiated to assess the necessity to pack or splint the nasal bone after routine closed reduction. Methods: We analysed the medical records of 35 patients with nasal bone fracture who were operated by closed reduction in the last 2 years. We evaluated the postoperative CT scan scores and external deviation criterias 1 month after the operation. Results: The postoperative deviation criteria and postoperative CT scan score were favorable and there were no serious complications using this technique. Conclusion: The present study demonstrates that the use of packing or splinting need not be routine in the majority of cases. The risks and discomforts associated with these procedures can often be avoided.

How to Choose and Use the CBCT (임상가를 위한 특집 1 - CBCT의 선택과 처방)

  • An, Chang-Hyeon
    • The Journal of the Korean dental association
    • /
    • v.52 no.3
    • /
    • pp.132-138
    • /
    • 2014
  • The emergence of Cone Beam Computed Tomography(CBCT) in the late 1990s represented an innovative advancement in the field of dental and maxillofacial radiology because it greatly reduced the radiation exposure to patients and offered 3D images easily. The 3D information generated by this technique brings the potential of improved diagnosis and treatment planning for a wide range of clinical applications in dentistry. The use of CBCT includes diagnosis and surgical assessment of the orofacial hard tissue lesions, dental implant treatment planning and postoperative evaluation, TMJ assessment, diagnosis of craniofacial fracture, orthodontics, endodontics, and so on. All CBCT examinations should be justified on an individualized needs. The clinical benefits to the patient for each CBCT scan must outweigh the potential risks associated with exposure to ionizing radiation. CBCT scans should be taken with initially obtained medical and dental histories of patients and a close clinical examination. CBCT should be considered as an imaging alternative of other conventional radiography in cases where the anatomical structures of interest may not be seen. The smallest possible field of view(FOV) and the lowest setting of tube current and scan time should be chosen, and the entire images scanned should be interpreted by a qualified expert.

Precision of the milled full-arch framework fabricated using pre-sintered soft alloy: A pilot study

  • Woo, Hyun-Wook;Cho, Sung-Am;Lee, Cheong-Hee;Lee, Kyu-Bok;Cho, Jin-Hyun;Lee, Du-Hyeong
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.2
    • /
    • pp.128-131
    • /
    • 2018
  • PURPOSE. This study aimed to evaluate the marginal discrepancy of full-arch frameworks in implant-supported prostheses fabricated using pre-sintered soft alloy (PSA). MATERIALS AND METHODS. Full-arch metal frameworks were fabricated on the edentulous implant model using casting alloy (CA), fully-sintered hard alloy (FHA), and PSA (n = 4 in each group). To evaluate the misfit of the framework to the abutments, the absolute marginal discrepancy (AMD) values of the frameworks were measured in cross-sectional images that had been drawn as part of the triple-scan protocol. The AMD values were compared among the tested alloy groups using the Kruskal-Wallis test, with a post hoc Mann-Whitney U test (${\alpha}=.05$). RESULTS. The FHA and PSA groups showed lower marginal discrepancies than the CA group (P<.001). However, the FHA group did not differ significantly from the PSA group. CONCLUSION. Soft alloy milling is comparable to hard alloy milling, and it is more precise than casting in terms of the marginal fit of implant-supported, full-arch prostheses.

On Characterization for Stacking Fault Evaluation of CF/Epoxy Composite Laminates Using an EMAT Ultrasonics (전자기 초음파를 이용한 CF/Epoxy 복합적층판의 적층결함 특성평가)

  • Im Kwanghee;Na Seungwoo;Hsu David K.;Lee Changro;Park Jewoung;Sim Jaeki;Yang Inyoung
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.10a
    • /
    • pp.254-257
    • /
    • 2004
  • An electromagnetic acoustic transducers (EMAT) can usually generate or detect an ultrasonic wave into specimens across a small gap. Especially stiffness of composites depends on layup sequence of CFRP(carbon fiber reinforced plastics) laminates because the layup of composite laminates influences there properties. It is very important to evaluate the layup errors in prepreg laminates. A nondestructive technique can therefore serve as a useful measurement for detecting layup errors. It was shown experimentally that this shear waves for detecting the presence of the errors is very sensitive. It is found that high probability shows between tests and the model developed in characterizing cured layups of the laminates. Also a C-scan method was used for detecting layup of the laminates because of extracting fiber orientation information from the ultrasonic reflection caused by structural imperfections in the laminates. Therefore, it was found that interface C-scan images show the fiber orientation information by using two-dimensional fast Fourier transform(2-D FFT).

  • PDF

A reverse engineering system for reproducing a 3D human bust (인체 흉상 복제를 위한 역공학 시스템)

  • 최회련;전용태;장민호;노형민;박세형
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.15-19
    • /
    • 2001
  • A dedicated reverse engineering(RE) system for rapid manufacturing of human head in a 3D bust has been developed. The first step in the process is to capture the surface details of a human head and shoulder by three scanners based upon the digital moire fringe technique. Then the multiple scans captured from different angles are aligned and merged into a single polygonal mesh, and the aligned data set is refined by smoothing, subdividing or hole filling process. Finally, the refined data set is sent to a 4-axis computer numerically control(NC) machine to manufacture a replica. In this paper, we mainly describe on the algorithms and software for aligning multiple data sets. The method is based on the recently popular Iterative Closest Point(ICP) algorithm that aligns different polygonal meshes into one common coordinate system. The ICP algorithm finds the nearest positions on one scan to a collection of points on the other scan by minimizing the collective distance between different scans. We also integrate some heuristics into the ICP to enhance the aligning process. A typical example is presented to validate the system and further research work is also discussed.

  • PDF

Design of the Step-stare Image Gathering System for an Aerial Reconnaissance (항공 정찰용 Step-stare 영상획득 시스템 설계)

  • Baek, Woonhyuk;Park, Jaeyoung;Ahn, Junghun;Lee, Jungsuk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.9
    • /
    • pp.813-820
    • /
    • 2014
  • This paper presents design and performance validation of a method for motion compensation using fast steering mirror. First of all, the schematics of the Electro Optical/Infra-Red (EO/IR) and step-stare image gathering system for an aerial reconnaissance are introduced. Because of the steering mirror with low inertia so called Back scan mechanism (BSM), the fast step-stare image gathering technique that is required for taking a high-definition still image will be realized. After then, the BSM hardware includes motors and feedback sensors are introduced. Also, the motion profile for BSM will be designed to compensate roll scan motion of the gimbals. At the end of this paper, designed profile and tracking performance of the EO/IR system with BSM will be validated through experiments.

Optical fiber polishing technique using a CO2 laser (CO2 레이저를 이용한 초정밀 광섬유 연마 레이저 기술)

  • Choi, Hun-Kook;Sohn, Ik-Bu;Noh, Young-Chul;Jung, Deok;Lee, Man-Seop;Lee, Seo-Young;Lee, Hyung-Jong
    • Laser Solutions
    • /
    • v.16 no.2
    • /
    • pp.12-15
    • /
    • 2013
  • In this paper, we controlled the edge angle of fiber by using $CO_2$ laser. In order to control the angle, tilting angle of fiber on stage and the number of scan repetition are adjusted, and laser power is fixed at 30 W in the experiment. In the polishing result, the edge angle of fiber can be changed from $4^{\circ}$ to $8^{\circ}$, as changing the tilting angle and the number of scan repetition. This $CO_2$ laser polishing can fabricate ball lenses with various curvatures and a sharp probe as well as the edge angled fiber.

  • PDF

Internal Pattern Matching Algorithm of Logic Built In Self Test Structure (Logic Built In Self Test 구조의 내부 특성 패턴 매칭 알고리즘)

  • Jeon, Yu-Sung;Kim, In-Soo;Min, Hyoung-Bok
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1959-1960
    • /
    • 2008
  • The Logic Built In Self Test (LBIST) technique is substantially applied in chip design in most many semiconductor company in despite of unavoidable overhead like an increase in dimension and time delay occurred as it used. Currently common LBIST software uses the MISR (Multiple Input Shift Register) However, it has many considerations like defining the X-value (Unknown Value), length and number of Scan Chain, Scan Chain and so on for analysis of result occurred in the process. So, to solve these problems, common LBIST software provides the solution method automated. Nevertheless, these problems haven't been solved automatically by Tri-state Bus in logic circuit yet. This paper studies the algorithm that it also suggest algorithm that reduce additional circuits and time delay as matching of pattern about 2-type circuits which are CUT(circuit Under Test) and additional circuits so that the designer can detect the wrong location in CUT: Circuit Under Test.

  • PDF

A Case of Hepatic Hemangioma Detected by Blood Pool Scan with $^{99m}Tc$ Human Serum Albumin ($^{99m}Tc$-albumin 혈관조영술(血管照影術)로 진단(診斷)한 간혈관종(肝血管腫)의 일례(一例))

  • Yoon, Hwi-Joong;Moon, Hee-Bum;Kwon, In-Soon;Choi, Kang-Won;Kim, Chung-Yong;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.13 no.1_2
    • /
    • pp.73-76
    • /
    • 1979
  • A case of hepatic hemangioma is presented in which blood pool imaging by $^{99m}Tc$-HSA provided a definite diagnostic clue. Cavernous hemangiomas are the most common benign tumor of the liver. But the majority of them are asymptomatic and are found incidentally at laparotomy or autopsy. Selective hepatic arteriogrophy has been the most helpful technique for the preoperative diagnosis. Recently radioisotope scan and ultrasonogram proved to be a new, definite and non-invasive diagnostic procedure.

  • PDF