• Title/Summary/Keyword: Scan statistics

Search Result 65, Processing Time 0.022 seconds

A study of statistical techniques for clinical data about cerebrovascular diseases (중풍임상자료(中風臨床資料)에 대한 통계적(統計的) 분석방법연구(分析方法硏究))

  • Kang, Hyo-Shin;Kwon, Young-Kyu;Park, Chang-Gook;Shin, Yang-Kyu;Kim, Sang-Chul
    • The Journal of Korean Medicine
    • /
    • v.17 no.1 s.31
    • /
    • pp.302-328
    • /
    • 1996
  • I . Objective and significance of the study To design a data acquisition chart, which facilitates data collection and analysis. The chart is also useful for solving problems that arise from personal variations in clinical symptoms and filling the knowledge base of an expert system. II. Content and scope 1. Collect the diagnosis knowledge of cerebrovacular diseases from doctors and analyze it. 2. Design a data acquisition chart. 3. Compare ODS and doctors with respect to their diagnosis results 4. Select patients who are determined to suffer from cerebrovascular diseases using CT(computed tomographic) scan, collect clinical data from them. III. Results and Application The chart be used for data collection and analysis in different medical hospitals, The results of data analysis facilitates collecting clinical data about other diseases and implementing the knowledge base. Also, the collected data serves as a tool for medical education, and cooperative diagnosis of oriental and western medical doctors.

  • PDF

Evaluation of the dimensional change of 3D-printed complete denture after post-curing (후경화에 따른 3차원 프린팅 의치의 체적변화)

  • Suyeon, Lee;Younghun, Kwak;Eunchul, Park;Heejung, Kim
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.233-241
    • /
    • 2022
  • Purpose: The purpose of this study was to assess the dimensional change of 3D-printed dentures after post-curing. Materials and Methods: The upper and lower dentures were designed in Exocad DentalCAD software and exported as STL files. The upper and lower dentures were printed from 10 STL files using a DLP-type dental 3D printer. The printed upper and lower dentures were cleaned, and a scan file was created using a model scanner before and after post-curing. The dimensional change was evaluated by superimposing the scanned denture files before and after post-curing and measuring the distance between measurement points on the denture. SPSS was used for statistics, and the level of significance was 5%. Results: The maxillary denture reduced in size during post-curing, with the most notable color change occurring in the posterior palatal region. The reduction in anteroposterior maxillary denture length (A-D, A-E, A-F), as well as the distance between the first molars on both sides (B-C), was statistically significant. After post-curing, the mandibular denture showed more noticeable color change in the posteriorly buccal and lingual region. The decrease of length on the posterior (A-M, A-D, A-E, A-L, A-H, A-I, H-I) and lingual (J-K, L-M) sides of the denture were statistically significant. Conclusion: There was significant dimensional change in both the length and width of the 3D-printed maxillary and mandibular dentures after post-curing in this experiment. Consequently, it is seemed necessary to develop post-curing techniques and materials that reduce such denture deformation.

Diagnostic Performance of Cardiac CT and Transthoracic Echocardiography for Detection of Surgically Confirmed Bicuspid Aortic Valve: Effect of Calcium Extent and Valve Subtypes (외과적으로 확진된 이첨 대동맥 판막의 진단을 위한 심장 CT 및 경흉부 심초음파의 진단적 성능: 판막 아형 및 칼슘의 양이 미치는 효과)

  • Jeongju Kim;Sung Mok Kim;Joonghyun Ahn;Jihoon Kim;Yeon Hyeon Choe
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1324-1336
    • /
    • 2023
  • Purpose This study aimed to compare the diagnostic performance of cardiac CT and transthoracic echocardiogram (TTE) depending on the degree of valvular calcification and bicuspid aortic valve (BAV) subtype. Materials and Methods This retrospective study included 266 consecutive patients (106 with BAV and 160 with tricuspid aortic valve) who underwent cardiac CT and TTE before aortic valve replacement. Cardiac CT was used to evaluate the morphology of the aortic valve, and a calcium scoring scan was used to quantify valve calcium. The aortic valves were classified into fused and two-sinus types. The diagnostic accuracy of cardiac CT and TTE was calculated using a reference standard for intraoperative inspection. Results CT demonstrated significantly higher sensitivity, negative predictive value, and accuracy than TTE in detecting BAV (p < 0.001, p < 0.001, and p = 0.003, respectively). The TTE sensitivity tended to decrease as valvular calcification increased. The error rate of TTE for CT was 10.9% for the twosinus type of BAV and 28.3% for the fused type (p = 0.044). Conclusion Cardiac CT had a higher diagnostic performance in detecting BAV than TTE and may help diagnose BAV, particularly in patients with severe valvular calcification.

Development of Conformal Radiotherapy with Respiratory Gate Device (호흡주기에 따른 방사선입체조형치료법의 개발)

  • Chu Sung Sil;Cho Kwang Hwan;Lee Chang Geol;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.41-52
    • /
    • 2002
  • Purpose : 3D conformal radiotherapy, the optimum dose delivered to the tumor and provided the risk of normal tissue unless marginal miss, was restricted by organ motion. For tumors in the thorax and abdomen, the planning target volume (PTV) is decided including the margin for movement of tumor volumes during treatment due to patients breathing. We designed the respiratory gating radiotherapy device (RGRD) for using during CT simulation, dose planning and beam delivery at identical breathing period conditions. Using RGRD, reducing the treatment margin for organ (thorax or abdomen) motion due to breathing and improve dose distribution for 3D conformal radiotherapy. Materials and Methods : The internal organ motion data for lung cancer patients were obtained by examining the diaphragm in the supine position to find the position dependency. We made a respiratory gating radiotherapy device (RGRD) that is composed of a strip band, drug sensor, micro switch, and a connected on-off switch in a LINAC control box. During same breathing period by RGRD, spiral CT scan, virtual simulation, and 3D dose planing for lung cancer patients were peformed, without an extended PTV margin for free breathing, and then the dose was delivered at the same positions. We calculated effective volumes and normal tissue complication probabilities (NTCP) using dose volume histograms for normal lung, and analyzed changes in doses associated with selected NTCP levels and tumor control probabilities (TCP) at these new dose levels. The effects of 3D conformal radiotherapy by RGRD were evaluated with DVH (Dose Volume Histogram), TCP, NTCP and dose statistics. Results : The average movement of a diaphragm was 1.5 cm in the supine position when patients breathed freely. Depending on the location of the tumor, the magnitude of the PTV margin needs to be extended from 1 cm to 3 cm, which can greatly increase normal tissue irradiation, and hence, results in increase of the normal tissue complications probabiliy. Simple and precise RGRD is very easy to setup on patients and is sensitive to length variation (+2 mm), it also delivers on-off information to patients and the LINAC machine. We evaluated the treatment plans of patients who had received conformal partial organ lung irradiation for the treatment of thorax malignancies. Using RGRD, the PTV margin by free breathing can be reduced about 2 cm for moving organs by breathing. TCP values are almost the same values $(4\~5\%\;increased)$ for lung cancer regardless of increasing the PTV margin to 2.0 cm but NTCP values are rapidly increased $(50\~70\%\;increased)$ for upon extending PTV margins by 2.0 cm. Conclusion : Internal organ motion due to breathing can be reduced effectively using our simple RGRD. This method can be used in clinical treatments to reduce organ motion induced margin, thereby reducing normal tissue irradiation. Using treatment planning software, the dose to normal tissues was analyzed by comparing dose statistics with and without RGRD. Potential benefits of radiotherapy derived from reduction or elimination of planning target volume (PTV) margins associated with patient breathing through the evaluation of the lung cancer patients treated with 3D conformal radiotherapy.

Comparing the Change in SUVmax Over Time by the Type of Ductal Breast Carcinoma (유방암 환자 중 유관에서 발병되는 암의 종류(IDC와 DCIS)별 시간경과에 따른 SUVmax 변화에 대한 비교)

  • Hyoung, Mi-Jin;Kim, Jeong Nip;Moon, Pyeong Soo;Kim, Kil Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.140-144
    • /
    • 2014
  • Purpose: The recent surge in breast carcinoma patients is reported in a variety of statistics. Breast cancer occurs mainly from duct and lobulus: 85% is from the breast ducts. The present study is aimed to distinguish the difference in $SUV_{max}$ changing over time by identifying the type of cancers attacking from the duct. Materials and Methods: The subjects of the study are 291 female breast cancer patients who have visited the present PET/CT center from July 1, 2012 to July 23, 2013. Based on the pathological results, 248 IDC (invasive ductal carcinoma) patients and 43 DCIS (ductal carcinoma in situ) patients were selected. In the same manner as the general PET/CT scan (3.7 MBq/Kg), F-FDG was injected, followed by the primary test (Routine tests) after 1 hr, and the secondary test (Delay test) after another hr. $SUV_{max}$ was measured after setting ROI in the lesion based on the data from the two tests. Results: As the comparative result of the change in the lesion $SUV_{max}$ between the two groups, IDC group's $SUV_{max}$ showed M=7.11 and SD=5.405 in the primary test and increased M=7.11 and SD=5.405 in the secondary test (P<0.05); DCIS group's $SUV_{max}$ showed M=2.739, SD=1.229 in the primary test and increased M=2.614, SD=1.470 in the secondary test (P<0.05). Conclusion: As the comparative result of $SUV_{max}$ over time between the groups, IDC showed increased $SUV_{max}$ in the secondary test (Delay test) compared to the primary test (Routine test) (P=0.000); DCIS showed decreased $SUV_{max}$ in the secondary test (Delay test) compared to the primary test (Routine test) (P=0.039). It was confirmed through this study that the change in $SUV_{max}$ has occurred over time by the type of breast cancer (IDC or DCIS) occurring from the breast ducts. However, the onset of breast cancers (ILC, LCIS) from the lobulus was not discussed due to the lack of samples. Future research on the breast cancers from the lobulus is suggested.

  • PDF