• Title/Summary/Keyword: Scan range

Search Result 473, Processing Time 0.03 seconds

Analysis of the ES detection loss related to the circular scan of radars (레이더의 원형 스캔에 따른 ES 탐지손실 분석)

  • Ryoo, Young-Jin;Kim, Whan-Woo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.6
    • /
    • pp.159-166
    • /
    • 2005
  • The pulse amplitude of a search radar signal received by an ES system is not constant pulse by pulse because of the radar's scan characteristics. The variation of the pulse amplitude causes the ES detection loss in the ES system. Therefore, the ES detection range equation should consider the ES detection loss caused by the search radar's scan characteristics. In this paper, we theoretically analyze the ES detection loss for the circular scar and propose the model to evaluate it quantitatively. The experiment results for the real search radar signals demonstrate that the proposed model is suitable for the evaluation model of the ES detection loss related to the circular scan of radars.

Re-evaluation on conversion system of BactoScan and BactoCount for raw milk in South Korea (국내 원유 세균수 검사장비 박토스캔 및 박토카운트의 보정식 재평가)

  • Kim, ESeul;Kim, Jin-Hwan;Byun, Yeong-Seob;Park, Dasom;Kim, Ha-Young;Yoon, Soon-Seek;Moon, Jin-San
    • Korean Journal of Veterinary Service
    • /
    • v.45 no.1
    • /
    • pp.39-45
    • /
    • 2022
  • The total bacteria count is significantly important factor for hygienic quality in raw milk. BactoScan FMTM and BactoCount IBCTM are the automated instruments for the determination of the total bacterial count in raw milk. They have been used after calibration by standard plate count (SPC) method in South Korea since 2000. It is necessary to re-evaluate for total bacterial counter according to the improvement of milk quality and the change of milk quality grade. Therefore, this study was evaluated the conversion mode of the two machines by SPC method. We collected 921 bulk-tank milk samples throughout the concentration range of 1,000~1,000,000 CFU/mL from June 2020 to October 2021. As a result, when compared by the SPC value, there was a slight difference in total bacterial count in BactoScan below 10,000 CFU/mL and above 200,000 CFU/mL and in BactoCount above 100,000 CFU/mL, respectively. Therefore, the conversion factor for BactoScan and the conversion equation for BactoCount were newly adjusted based on SPC value, and then the correlation coefficients (R2) was 0.85 or higher. In addition, the correlation (R2) between BactoScan and BactoCount was 0.91, which means the results were high positive correlation. These results are expected to contribute to improving the accuracy of the automated instruments for determining of total bacterial count in raw milk.

Bright band detection using X-band polarimetric radar (X-밴드 이중편파 레이더에 의한 밝은 띠 탐지)

  • Lee, Dong-ryul;Jang, Bong-joo;Hwang, Seok Hwan;Noh, Hui-seong
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.12
    • /
    • pp.1211-1220
    • /
    • 2020
  • This research detects the features of the bright band (BB) through analysis of the vertical profile of range height indicator (RHI) and the slant range beam profile of plane position indicator (PPI) of the polarimetric radar measurements-horizontal reflectivity (ZH), differential reflectivity (ZDR), and cross-correlation coefficient (ρHV). As a result of the analysis, it is possible to clearly detect the bright band using the polarimetric radar measurements, and it is confirmed that the result is consistent by double searching for the BB using the RHI and PPI scan data at the same time. Based on these results, the accuracy of QPE (quantification of precipitation estimation) can be improved by applying the BB search method by the PPI slant range in this research to large rainfall radars that only scan PPI volumes in the field without RHI observations.

Analysis of body shape and anthropometric measurements of US middle-aged women using 3D body scan data

  • Kim, Dong-Eun
    • The Research Journal of the Costume Culture
    • /
    • v.23 no.4
    • /
    • pp.726-736
    • /
    • 2015
  • The apparel industry has recently been recognizing the important target market of middle-aged women. The aim of this study was to examine the anthropometric characteristics of US women of 46 to 65 years of age and identify distinctive body shape characteristics of US middle-aged women. A total of 1915 middle-aged women whose ages ranged from 46 to 65 were selected from the SizeUSA database. The age range was divided into two groups: 46-55 and 56-65. Twenty-four body measurements important for apparel development were chosen. Four factors-Girth Factor, Height Factor, Hip Drop Factor, and Bust Drop Factor-accounted for the US middle-aged women's body measurements. The body shapes were classified into four body shapes, which were Y-Shape in the overweight range, S-Shape in the overweight range, H-Shape in the overweight range, and the A-Shape in obese range. H-Shape, which was the least-defined waist in relation to the bust and hips with a short height, existed more in older middle-aged women than in younger middle-aged women. Y-Shape, S-Shape, and A-Shape existed more in the group of younger middle-aged women than in the group of older middle-aged women. In addition, compared with the younger middle-aged women, older middle-aged women had narrower shoulders, a larger waist, thinner legs, and a longer distance between side neck to bust point. The findings from the current study may be applied in the apparel industry for developing clothing sizing systems for US middle-aged women.

GENERATION OF AIRBORNE LIDAR INTENSITY IMAGE BY NORMALIZAING RANGE DIFFERENCES

  • Shin, Jung-Il;Yoon, Jong-Suk;Lee, Kyu-Sung
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.504-507
    • /
    • 2006
  • Airborn Lidar technology has been applied to diverse applications with the advantages of accurate 3D information. Further, Lidar intensity, backscattered signal power, can provid us additional information regarding target's characteristics. Lidar intensity varies by the target reflectance, moisture condition, range, and viewing geometry. This study purposes to generate normalized airborne LiDAR intensity image considering those influential factors such as reflectance, range and geometric/topographic factors (scan angle, ground height, aspect, slope, local incidence angle: LIA). Laser points from one flight line were extracted to simplify the geometric conditions. Laser intensities of sample plots, selected by using a set of reference data and ground survey, werethen statistically analyzed with independent variables. Target reflectance, range between sensor and target, and surface slope were main factors to influence the laser intensity. Intensity of laser points was initially normalized by removing range effect only. However, microsite topographic factor, such as slope angle, was not normalized due to difficulty of automatic calculation.

  • PDF

The Value of Tc-99m DTPA Diuretic Renography for Assessment of Dilated Upper Urinary Tract in Children (소아의 상부 요관확장증에서 폐쇄 유무 감별에 있어 Tc-99m DTPA 이뇨 신장 신티그램의 유용성)

  • Yang, Ki-Ra;Lim, Gye-Yeon;Sohn, Hyung-Sun;Hahn, Seong-Tae;Lee, Jae-Mun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.57-64
    • /
    • 1999
  • Purpose: The purpose of this study was to evaluate the accuracy of Tc-99m DTPA diuretic renal scans in children with dilated upper urinary tract. Materials and Methods: We reviewed diuretic renal scans of 14 pediatric patients (age range: 3 days to 4 years) with unilateral hydronephrosis diagnosed by ultrasonography. Diuretic renal scan was done using Tc-99m DTPA and standardized protocol. In 3 neonates, diuretic renal scans were performed within 1 week and 3-7 months after birth. Results: Six patients required Pyeloplasty and eight were managed conservatively. All 6 patients requiring Pyeloplasty were diagnosed as having ureteropelvic junction obstruction in the diuretic renal scan. In these 6 patients, post-operative renal scans at 3-12 months after surgery were converted to nonobstructive pattern in 5 and a nonfunctioning pattern in 1. In 3 patients who underwent diuretic renal scan within 1 week after birth, nonobstructive patterns of initial scan were converted to obstructive patterns in the follow-up scan. However, all patients with nonobstructive diuretic renal scans performed after the neonatal period did well on serial ultrasonography and showed favorable clinical outcome without progression to obstruction. Conclusion: Tc-99m DTPA diuretic renal scan with standardized protocol is useful in assessing suspected ureteropelvic junction obstruction in children as an initial diagnostic or post-operative follow-up modality. Nonobstructive or indeterminate scan results in the neonatal period requires follow-up scan to monitor development of the obstructive pattern.

  • PDF

2D Pattern Development of Tight-fitting Bodysuit from 3D Body Scan Data for Comfortable Pressure Sensation (인체의 3차원 스캔 데이터를 이용한 밀착 바디 슈트 개발)

  • Jeong, Yeon-Hee
    • Korean Journal of Human Ecology
    • /
    • v.15 no.3
    • /
    • pp.481-490
    • /
    • 2006
  • Adjusting pressure level in the construction of athletes' tight-fitting garments by reducing the elastic knit pattern is a challenging subject, which influences the performance of the wearer directly. Therefore, in this study, relationship between the reduction rates of the basic pattern obtained from 3D human scan data and resultant clothing pressure was explored to improve the fit and pressure exerted by clothing. 3D scan data were obtained using Cyberware and they were transformed into a flat pattern using software based on Runge-Kutta method. Reduction rate was examined by subjective wear test as well as objective pressure measurement. As a result, difference in the length between the original 3D body scan data and the 2D tight-fitting pattern was 0.02$\sim$0.50cm (0.05$\sim$1.06%), which was within the range of tolerable limits in making clothes. Among the five garments, the 3T-pattern was superior in terms of subjective sensation and fit. The pressure of the 3T pattern was 2$\sim$4 gf/cm2 at five locations on the body, which is almost the same or a bit higher than that of Z-pattern. In the case of tight-fitting overall garment, the reduction rate of the pattern in the wale direction is more critical to the subjective sensation than the course direction. It is recommended that the reduction grading rules of course direction should be larger than that of Ziegert for a better fit of tight-fitting garments. In the case of wale direction, however, reduction grading rule should be kept the same as suggested earlier by Ziegert (1988).

  • PDF

A Case of Budd-Chiari Syndrome Which Shows Space Occupying Lesion on Liver Scan (간 스캔상 공간점유병소의 소견을 보인 Budd-Chiari증후군 - 1예 보고 -)

  • Lee, Jeong-Hae;Lee, Youn-Ha;Seo, Dae-Won;Jang, Tae-Jong;Hwang, In-Shup;Kim, Young-Jung;Kim, So-Yon;Lee, Gwon-Jun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.397-401
    • /
    • 1994
  • A twenty-one-year-old man visited our hospital due to abdominal distension for a month. On the physical examination, there was severe abdominal distension with fluctuation and shifting dullness. The routine laboratory results were within normal range. On the Magnetic Resonace angiography, there wasn't any blood flow within the right and middle hepatic vein. So we concluded that the etiologic disease was Budd-Chiari syndrome. On the liver scan, there was cold area(absence of radiouptake) on entire right lobe of the liver, increased uptake on the bone marrow and showed splenomegaly. This finding was similar to the liver mass occupying right lobe with underlying chronic liver disease. On the previous reports, it is quite uncommon finding that Budd-Chirari syndrome shows lesion like space occupying one on the liver scan. So we report this case with a review of the literature.

  • PDF

Development of 2D Tight-fitting Pattern from 3D Scan Data (3D 스캔 데이터를 활용한 밀착 패턴원형 개발)

  • Jeong, Yeon-Hee;Hong, Kyung-Hi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.1 s.149
    • /
    • pp.157-166
    • /
    • 2006
  • The human body, which is composed of concave and convex curvatures, makes it difficult to transfer into 2D patterns directly from 3D data. In previous studies. Jeong, et al.(2004) suggested the block method was fester and easier when dealing with the triangular patches of male's upper dress form. Although the block method is useful to make a pattern, the information(area, length, etc.) from a 2D pattern would be different depending on the direction of the block method. As a result horizontal and diagonal block methods were suggested as optimal methods for 2D tight-fitting patterns. These block methods were closer to the original area of the 3D scan data than the vertical block method. The total area of the 2D pattern obtained by the horizontal and diagonal block methods showed little differences. In case of the horizontal and diagonal block methods, the total error of the 2D pattern area ranged from $0.01\%\~0.25\%$. In comparing the length of the 2D pattern with that of the 3D scan data, the obtained 2D pattern was $0.1\~0.2cm$ shorter than the 3D scan data, which was within the acceptable range of errors in making clothes. 3D space distribution images between the body surface and the experimental clothing were also measured and $3\%$ enlargement of the original pattern was verified as the adequate adjustment.

Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols (64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소)

  • Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • Purpose : To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Materials and Methods : Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation ($0.625\;mm{\times}64\;ea$), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of $40{\sim}80%$ of R-R interval and 120mA(80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. Results : The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with that of conventional coronary CTA. And heart dose was 33.8 mGy, this represents 67.4% reduction. In the sequential scan technique under prospective ECG gating with low kVp the mean effective dose was 3.0 mSv, this represents an 83.2% reduction compared with that of conventional coronary CTA. And heart dose was 17.7 mGy, this represents an 82.9% reduction. Conclusion : In coronary CTA at retrospectively ECG gated helical scan, cardiac dose modulation technique using low kVp reduced dose to 50% above compared with the conventional helical scan. And the prospectively ECG gated sequential scan offers substantially reduced dose compared with the traditional retrospectively ECG gated helical scan.

  • PDF