• Title/Summary/Keyword: Scan modulation

Search Result 31, Processing Time 0.033 seconds

The Optimal Condition for Velocity Modulation

  • Park, Joon-Suk;Kim, Do-Nyun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.1157-1159
    • /
    • 2003
  • The effect of the scan velocity modulation is studied. The effect of the velocity modulation on the picture image is judged from the intensity profile of the image. The intensity profile is obtained as time integral of moving Gaussian beam. To confirm the applicability of this integral formula, the measurement and simulation data is compared. And by calculating the intensity profile for different amounts of velocity modulation, the optimum modulation displacement that gives the best image quality is obtained. This optimum modulation displacement can be used in designing scan velocity modulation system.

  • PDF

Study of the RF Test signal generation methods for receiver performance verification (신호수신시스템 성능예측을 위한 신호원 모의발생 방안 연구)

  • Kim, Dong-Gyu;Yoon, Won-Sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.353-356
    • /
    • 2011
  • A Signal Receiving system to collect and analyze RF signals should be verified under simulated RF signal environment prior to verification on operation in fields and tested by using simulated RF signals in order to estimate its electrical performance. Generally, typical Signal Receiving system can measure, analyze frequency, pulse modulation, scan modulation, phase modulation on pulse, frequency modulation on pulse etc on RF signals. These RF signals should be generated from simulated RF sources in laboratory. Also the simultaneous RF signals should be simulated on laboratory. This paper describes the results of studying effective simulated RF signal source generation, the methods of the precise RF test signal generation in consideration of operational scenario.

  • PDF

Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols (64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소)

  • Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • Purpose : To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Materials and Methods : Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation ($0.625\;mm{\times}64\;ea$), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of $40{\sim}80%$ of R-R interval and 120mA(80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. Results : The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with that of conventional coronary CTA. And heart dose was 33.8 mGy, this represents 67.4% reduction. In the sequential scan technique under prospective ECG gating with low kVp the mean effective dose was 3.0 mSv, this represents an 83.2% reduction compared with that of conventional coronary CTA. And heart dose was 17.7 mGy, this represents an 82.9% reduction. Conclusion : In coronary CTA at retrospectively ECG gated helical scan, cardiac dose modulation technique using low kVp reduced dose to 50% above compared with the conventional helical scan. And the prospectively ECG gated sequential scan offers substantially reduced dose compared with the traditional retrospectively ECG gated helical scan.

  • PDF

The Evaluation of Eye Dose and Image Quality According to The New Tube Current Modulation and Shielding Techniques in Brain CT (두부 CT에서 차폐기법과 새로운 관전류변조기법에 따른 눈의 선량과 화질평가)

  • Kwon, Soonmu;Kim, Jungsu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.279-285
    • /
    • 2015
  • The eye of human is a radiation sensitive organ and this organ should be shielded from radiation exposure during brain CT procedures. In the brain CT procedures, bismuth protector using to reduce the radiation exposure dose for eye. But protecting the bismuth always accompanies problem of the image quality reduction including artifact. This study aim is the eye radiation exposure dose and image quality evaluation of the new tube current modulation such as new organ based-tube current modulation, longitudinal-TCM, angular-TCM between shielding scan technique using bismuth and lead glasses. As a result, radiation dose of eye is reduced 25.88% in new OB TCM technique then reference scan technique and SNR new OB TCM is 6.05 higher than bismuth shielding scan technique and lower than reference scan technique. In clinical brain CT, new OB TCM technique will contribute to reduction of radiation dose for eye without decrease of image quality.

Simulated RF Signal Generator for Receiver Performance Verification (신호수신시스템 성능 검증을 위한 신호원 모의발생기)

  • Kim, Donggyu;Yoon, Wonsik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.10
    • /
    • pp.2163-2170
    • /
    • 2012
  • A signal receiving system can measure and analyze frequency, pulse modulation, scan modulation, frequency modulation on pulse, phase modulation on pulse of RF signal. A signal receiving system should be verified under simulated RF signal environment prior to verification on operation in fields. This paper describes an effective method to generate simulated RF signals with considering operational scenario. The simulated RF signal generator can be effectively used to evaluate the performance of the signal receiver and reduce the test cost of the signal receiver.

Dual Modulation Driving for Poly-Si TFT Active Matrix OLED Displays (다결정 실리콘 박막 트랜지스터 Active Matrix OLED 디스플레이를 위한 이중 변조 구동)

  • 김재근;정주영
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.10
    • /
    • pp.17-22
    • /
    • 2004
  • We developed a new ANGLED display driving method which used both amplitude and pulse width modulation. For pulse width modulation, we divided a picture frame time into S sub-frames. For amplitude modulation, we used three OLED luminance(or current) levels which were controlled by TFT's gate voltages. By combining these two modulation methods, we obtained 35(=243) grey levels. And we designed a new data electrode driving circuit block with two shift registers without using DAC's. To verify the feasibility, we simulated the key circuit components by HSpice with TFT parameters extracted from current-voltage characteristics of 6${\mu}{\textrm}{m}$ channel length polysilicon TFT's. From the simulation results, we found that 320${\times}$240, dual scan, 243 grey level AMOLED display can be designed with this method.

Optimization of Energy Modulation Filter for Dual Energy CBCT Using Geant4 Monte-Carlo Simulation

  • Ju, Eun Bin;Ahn, So Hyun;Choi, Sang Gyu;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.3
    • /
    • pp.125-130
    • /
    • 2016
  • Dual energy computed tomography (DECT) is used to classify two materials and quantify the mass density of each material in the human body. An energy modulation filter based DECT could acquire two images, which are generated by the low- and high-energy photon spectra, in one scan, with one tube and detector. In the case of DECT using the energy modulation filter, the filter should perform the optimization process for the type of materials and thicknesses for generating two photon spectra. In this study, Geant4 Monte-Carlo simulation toolkit was used to execute the optimization process for determining the property of the energy modulation filter. In the process, various materials used for the energy modulation filter are copper (Cu, $8.96g/cm^3$), niobium (Nb, $8.57g/cm^3$), stannum (Sn, $7.31g/cm^3$), gold (Au, $19.32g/cm^3$), and lead (Pb, $11.34g/cm^3$). The thickness of the modulation filter varied from 0.1 mm to 1.0 mm. To evaluate the overlap region of the low- and high-energy spectrum, Geant4 Monte-Carlo simulation is used. The variation of the photon flux and the mean energy of photon spectrum that passes through the energy modulation filter are evaluated. In the primary photon spectrum of 80 kVp, the optimal modulation filter is a 0.1 mm lead filter that can acquire the same mean energy of 140 kVp photon spectrum. The lead filter of 0.1 mm based dual energy CBCT is required to increase the tube current 4.37 times than the original tube current owing to the 77.1% attenuation in the filter.

Implementation of Nonlinear SVM for HD Projection TV (HD Projection TV를 위한 비선형 SVM 회로의 구현)

  • Lee, Gwang-Sun;Gwon, Yong-Dae;Lee, Geon-Il;Song, Gyu-Ik;Choe, Deok-Gyu;Han, Chan-Ho;Kim, Eun-Su
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.2
    • /
    • pp.191-198
    • /
    • 2001
  • As a method to compensate the deterioration of the picture quality which was caused by beam profile characteristic in the CRT and the projection screen of HD projection TV, a linear scan velocity modulation(SVM) method has been employed, whose modulation velocity is linearly proportional to the variation in the video signal amplitude. However, the effect of picture quality improvement is not uniform with video signal amplitude in the linear SVM. In this paper, for the optimum SVM effect, we analyze the beam profile characteristic on the HD projection screen and we analyze the SVM effect as function of the differentiated pulse width, the differentiated pulse amplitude and the input signal amplitude. Finally we confirm that the nonlinear SVM method is necessary to get uniform image compensation in the HD projection TV, and we implement the nonlinear SVM circuit. The performance of the realized SVM circuit with nonlinear amplitude transfer characteristic is confirmed as uniform improvements in picture quality.

  • PDF

Phase Modulation Optical Delay Line for Ultrafast OCT Application (초고속 OCT응용을 위한 위상변조 광지연단)

  • Hwang Daeseo;Lee Young-Woo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.4
    • /
    • pp.861-864
    • /
    • 2005
  • In this paper, we system the system design and numerical analysis of the ultrafast optical delay line using by optical phase modulator. The numerical analysis carried out with 1310nm, lops laser and electro-optic phase modulator. As the results of numerical analysis, we show a scanning rate of 0.5 GHz and a delay range of 19.0ps. Compare with mechanical delay line, the optical delay line has a high scanning speed and a high repetition rate.

Development of Vehicle Side Collision Avoidance System with Virtual Driving Environments (가상주행환경에서의 측면 충돌 방지시스템 개발)

  • Yoon, Moon Young;Choi, Jung Kwang;Jung, Jae Eup;Boo, Kwang Seok;Kim, Heung Seob
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.2
    • /
    • pp.164-170
    • /
    • 2013
  • The latest vehicle yields a superior safety and reduction of driving burden by monitoring the driving state of vehicle and its environment with various sensors. To detect other vehicles and objects of the rear left and right-side blind spot area of driver, provide the information about a existence of objects inside the blind spot, and give a signal to avoid collision, this study proposes the intelligent outside rear-view mirror system. This study proposes SILS system with PreScan and Matlab/Simulink to verify practical applicability of developed BSDS. PreScan yields realistic driving environments and road conditions and vehicle model dynamics and collision warning is controlled by Matlab/Simulink.