• Title/Summary/Keyword: Scan body

Search Result 574, Processing Time 0.023 seconds

Upper Back Somatotype Analysis for Development of Hanbok Jeogori Pattern of Female in Late 20s (20대 후반 성인 여성의 한복 저고리 패턴 개발을 위한 상반신 뒷면의 체형 분석)

  • Eom, Ran-I;Lee, Yejin
    • Korean Journal of Human Ecology
    • /
    • v.23 no.5
    • /
    • pp.891-904
    • /
    • 2014
  • The objective of this study is to classify somatotypes of back-surface shape of women in their late 20s by using 3D body scan data(Size Korea 2010) in order to improve fitness of Hanbok Jeogori. The results were as follows: 1. According to the in-depth survey of the experienced expert's interview, most problems related to the fit were caused by the back area of Jeogori. 2. The result of factor analysis indicated that 6 factors were extracted and those factors comprised 82.85% of total variance. 3. According to the cluster analysis, back somatotypes of women in their late 20s were categorized by two types : straight type(54.1%) and bending type(46.9%). The results could be used as the Hanbok Jeogori to improve the fitness of back-surface shape.

3D Pattern Construction and Its Application to Tight-fitting Garments for Comfortable Pressure Sensation

  • Jeong Yeon-Hee;Hong Kyung-Hi;Kim See-Jo
    • Fibers and Polymers
    • /
    • v.7 no.2
    • /
    • pp.195-202
    • /
    • 2006
  • Tight-fitting clothing pattern reflecting the accurate information of the 3D body shape has been one of the challenges for garment industry, however, fitting problems still exist. The objectives of the paper is to develop a 2D pattern which fits tightly to the 3D human scan data for sports suits that need comfort and function for maximum performance. In this study, the user graphic interface application software for the semi-automatic garment pattern generation has been implemented using the triangle simplification scheme together with 2D projections of free-falling of 3D surface polygons keeping the original 3D surface area preservation. A typical application of the developed pattern to the functional body suits is presented and verification of the proposed method is also provided.

Examination about Utility of Prone Position in PET/CT of Stomach Cancer Patient (위암 환자의 양전자 방출 컴퓨터 단층 검사에서 복와위(伏臥位) 촬영의 유용성에 대한 연구)

  • NamKoong, Hyuk;Park, Hoon-Hee;Oh, Shin-Hyun;Bahn, Yung-Kag;Kim, Jung-Yul;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.93-99
    • /
    • 2010
  • Purpose: Currently, PET/CT scan has been known to provide useful information to both preoperative and postoperative examination of cancer patients. Contracted stomach by the long fasting could cause difficulties of interpretation because of its size on reconstructed image data. To solve this problem, after the whole body PET/CT scan, patients were administrated in drinking 300 mL of water to expand stomach and performed additional scan on stomach region. Not only PET/CT scan but also CT performs this water-administration, and patients were take oral solution to make stomach expand for stomach cancer. When this scan performed, patients lay supine position. In this study, we evaluated the capacity of stomach through PET/CT scan with drinking water performed in supine and prone position so that we can distinguish exact location of cancer around pylorus and inferior wall of stomach. Furthermore, image data from supine and prone positions were analyzed the difference of volume of stomach through the change of standardized uptake values. Materials and Methods: From July 2009 to January 2010 in severance hospital, 30 patients who were diagnosed as early gastric cancer or advanced gastric cancer were chosen. All patients had PET/CT scan before the operation and have had follow-up PET/CT. The patients fast for at least 8 hours, and had an injection intravenously with $^{18}F$-FDG, 7.4 MBq (0.2 mCi/kg) per kilogram. They were rested for 60 minutes. Before the examination, all patients were administrated to drink water for 300 mL Patients had PET/CT scan with supine position around the region of stomach, whole body, and around the region of stomach with prone position after drinking another 300 mL of water respectively. Results: As a results of comparison between stomach capacity of 30 patients in supine and prone position, the study draw results that average capacity of stomach body was 460.29 $mm^2$ in supine position, and 641.39 $mm^2$ in prone position for 30 patients. The change of capacity shows 41.3% expanded in prone position. And there was no noticeable difference at maximum standardized uptake values in supine position and prone position. Conclusion: As results, stomach would have more expanded capacity in prone position than supine position. For patients who have physical disabilities to move freely, additional scan in prone position will be obstacle to perform. However, if additional scan in supine position add with the scan in prone position, it will be easier to diagnose stomach cancer. Moreover, we believe that this study will help the research for inventing support tools for patients who have physical disabilities in prone position.

  • PDF

Classification of Upper Body Somatotypes according to the Age Group : Using 3D-Body Scan Data

  • Na, Hyun-Shin
    • International Journal of Costume and Fashion
    • /
    • v.5 no.1
    • /
    • pp.1-13
    • /
    • 2005
  • Two hundreds of female aged 19 years old and up were recruited to evaluate the postural changes and bilateral variation of asymmetry over age. To find out the differences among the age group, subjects were classified into 5 groups, early young age(19-29), late young age(30-39), early middle age(40-49), late middle age(50-59), and old age(60-). 35 body measurements were taken by the 3-D body scanner which allowed us to take measurements which cannot be measured using traditional methods, including the shape of a cross section, slice area surface are, and volume. Bilateral variations were observed as a function of age; Depth of scapular point level, scapular point to center back, and blade angle. Postural change of anterior cervical angle, upper anterior thoracic angle, upper posterior thoracic angle, posterior cervical angle, and center back/center front ratio were also exhibited. In each measurements, subjects were classified into normal, and abnormal group. Percentiles of abnormal in shoulder line angle, blade angle, neck point $\∼$ acromial point $\∼$ scapular point, posterior cervical angle, and upper posterior thoracic angle were increased over age group. The upper body of lateral view was classified into 3 types of posture based on the previous research; straight, erect(leaning back), and stooped(bent forward). The percentiles of subjects who have straight postures were decreased as a function of age, but those of stooped postures were increased. Subjects who have erect postures did not so. The stooped posture group shows the big cervical fossa angle, anterior cervical angle, posterior cervical angle, upper posterior thoracic angle, and the small upper anterior thoracic angle comparing to the straight and erect posture group. These results could be apply for clothing construction reflecting the changes in back, shoulder, neck, and the bilateral asymmetry according to the target age group.

Study a Technique for Reducing the Influence of Scattered Rays from Surrounding Organs to the Heart during Gated Cardiac Blood Pool scan (Gated Cardiac Blood Pool scan에서의 심장 주위 배후방사능 관심영역 설정시 산란선의 영향을 감소시키기 위한 연구)

  • Kim, Jung-Yul;Park, Hoon-Hee;NamKoong, Hyuk;Cho, Suk-Won;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.33-38
    • /
    • 2008
  • Purpose: The Gated cardiac blood pool scan is non-invasive method that a quantitative evaluation of left ventricular function. Also this scan have shown the value of radionuclide ejection fraction measurements during the course of chemotherapy as a predictor of cardiac toxicity. Therefore a reliable method of monitoring its cardiotoxic effects is necessary. the purpose of this study is to minimize the overestimate of left ventricular ejection fraction (LVEF) by modified body position to reduce the influence of scattered rays from surrounding organs of the heart in the background region of interest. Materials and Methods: Gated cardiac blood pool scan using in vivo $^{99m}Tc$-red blood cell (RBC) was carried out in 20 patients (mean $44.8{\pm}8.6$ yr) with chemotherapy for a breast carcinoma. Data acquisition requires about 600 seconds and 24 frames of one heart cycle by the multigated acquisition mode, Synchronization deteriorates toward the end of the cycle and with the distance from the trigger signal (R-wave) by ECG gating. Gated cardiac blood pool scan was studied with conventional method (supine position and the detector head in $30-45^{\circ}$ left anterior oblique position and caudal $10-20^{\circ}$ tilt) and compared with modified method (left lateral flexion position with 360 mL of drinking water). LVEF analysis was performed by using the automatically computer mode. Results: The ROI counts of modified scan method were lower than LV conventional method ($1429{\pm}251$ versus $1853{\pm}243$, <0.01). And LVEF of modified method was also decrease compared with conventional method ($58.3{\pm}5.6%$ versus $65.3{\pm}6.1%$, <0.01). Imaging analysis indicated that stomach was expanded because of water and spleen position was changed to lateral inferior compared with conventional method. Conclusion: This study shows that the modified method in MUGA reduce the influence of scattered rays from surrounding organs. Because after change the body position to left lateral flexion and drinking water, the location of spleen, left lobe of liver and stomach had changed and they could escaped from background ROI. Therefore, modified method could help to minimize the overestimate LVEF (%).

  • PDF

Analysis of Diffuse Hepatic Visualization after Iodine-131 Treatment in Patients with Thyroid Carcinoma (갑상선암 환자에서 전절제술 후 I-131 치료에서 미만성 간침착 정도의 분석)

  • Jung Jin-Hyung;Bae Keum-Seok;Kang Seong-Joon
    • Korean Journal of Head & Neck Oncology
    • /
    • v.16 no.2
    • /
    • pp.206-211
    • /
    • 2000
  • Objectives: Any uptake of I-131 after total thyroidectomy means the remant thyroid tissue or distant metastasis of the thyroid cancer. However diffuse hepatic uptake of I-131 without abnormal uptake was showen in many cases on I-131 whole body scan. The aim of this study was to classify the liver uptake after I-131 scan and to evaluate the analysis of this finding. Materials and Methods: Between 1982 and 1998, 104 patients(l4 males, 90 females) with normal liver function underwent I-131 scan after total thyroidectomy. Prospectively we reviewed the films of the whole body scan and analysed the correlations between results of radioiodine uptake, pathologic diagnosis, prognostic factors, lymphatic metastasis, and thyroid function test. Result: Diffuse hepatic uptake was found in 44 of 104(42%) patients. 10 of 39(26%) patients on I-131 100mCi, and 34 of 63(54%) on I-131 150mCi showed hepatic uptake. 52 of 104(50%) patients was locally invasive thyroid cancer. The rate of the hepatic uptake was no significant differences with the thyroid hormone levels(T3, Free T4) and thyroglobulin between uptake group and non-uptake group. Conclusion: The rate of I-131 uptake was high in high-dose radioiodine treatment group. However, we can not find any correlation among the thyroid functions, the extent of metastasis or the extent of local invasion. We need further study to find out the causes of the hepatic uptake of I-131 after total thyroidectomy, besides liver metabolism of I-131 attached thyroid hormones.

  • PDF

Management of Recurrent Thyroid Carcinoma with Negative Diagnostic Radioiodine Whole-Body Scan (진단적 방사성옥소 전신스캔이 음성인 갑상선 재발암의 진료)

  • Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.3
    • /
    • pp.117-124
    • /
    • 2001
  • Serum thyroglobulin measurement and I-131 whole-body scintigraphy (WBS) are well-established methods for the detection of recurrence in the follow-up of patients with thyroid carcinoma. However, inconsistent results are observed frequently, and these two methods are not always able to detect recurrence. In some patients, serum thyroglobulin level is elevated but the WBS is negative, because the recurrent tumor is too small and below the sensitivity of the diagnostic scan, or there is a dissociation between thyroglobulin synthesis and the iodine frapping mechanism. In such cases, various nuclear imaging methods including Tl-201 Tc-99m-sestamibi, and F-18-FDG PET can be used besides anatomical imaging methods. Among them, FDG PET localizes recurrent lesions in WBS-negative thyroid carcinoma with high accuracy. Several studies have suggested that empirical high-dose I-131 therapy resulted in a high rate of visualization in post-therapy scans with evidence of subsequent improvement. An important question is when to operate on patients with recurrent tumor. We believe that surgical removal is the best means of treatment for patients with localized persistent tumor, despite the high-dose I-131 therapy. with tumor in thyroid remnant, and with isolated recurrence in the lymph node, lung or bone. In addition, we recommend palliative resection of locally unresectable mass with subsequent treatment with high-dose I-131 therapy. Before I-131 therapy, the evaluation of sodium-iodide symporter expression in thyroid carcinoma can predict iodine uptake. Retinoic acid is known to induce redifferentiation, and to enhance I-131 uptake in thyroid carcinoma. Retinoic acid therapy may represent an alternative approach before high-dose I-131 therapy.

  • PDF

Subjective Wearing Assessment and Clothing Pressure depending on the Pattern Reduction Rate of Developed Cycle Pants Using the 3D Human Scan Data (3D 스캔 데이터를 이용하여 개발된 사이클 팬츠 패턴의 축소율에 따른 의복압 및 주관적 착의 평가)

  • Jeong, Yeonhee;Hong, Kyunghi
    • Korean Journal of Human Ecology
    • /
    • v.24 no.2
    • /
    • pp.255-266
    • /
    • 2015
  • In this study, we have developed the ergonomic pattern from the 3D human body reflecting cycling posture and extensibility of the stretch fabrics. Adjusting pressure level in the construction of athlete's tight-fitting stretch garments by reducing the original pattern is a challenging subject, which influence on the performance of the wearer directly. Therefore, in this study, relationships between the reduction rates of the 2D pattern obtained from the 3D human scan and resultant clothing pressure were explored to improve the fit and pressure exerted by reduced clothing pattern. Subjective wear sensations of the experimental garments were rated using a seven-point Likert scale on two consecutive days. While wearing the garments, subjects were asked to take five different postures including waist flexion, sitting and others. A Likert-type scale was used for the evaluation, with 7 points indicating the best fit in tight-fitting pants. Comparing 2/3T-pattern with T-pattern, the latter was superior to 2/3T-pattern in terms of adhere well to the waist and hip area in the 0.032 significance level. T-pattern was superior to 2/3T-pattern in terms of fitting and wear comfort. As results, the pattern obtained from the flexed body reflecting cycling posture already included the contraction and extension of the skin while cycling posture, so that the extra ease for movement and good fit was not need to be considered. The optimized reduction rates were determined with the proposed reduction rate, the resultant pressure range was within the range of $0.5{\sim}3.0gf/cm^2$ at eight locations on the body except front waist band and thigh band.

Evaluation of Therapeutic Effect with Serum Thyroglobulin and Whole Body Scan after 200mCi $^{131}I$ Treatment in Patients with Well-Differentiated Thyroid Carcinoma (전이성 분화 갑상선암에서 200mCi 방사성 옥소 치료효과 평가를 위한 혈청 Thyroglobulin 추적검사와 전신스캔의 의의)

  • Lee, Chang-Hee;Yoon, Jong-Kil;Jeong, Sang-Hoon;Kwu, Gyo-Seon;Choi, Chang-Woon;Lim, Sang-Moo;Hong, Sung-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.451-459
    • /
    • 1995
  • Thirty-eight patients with metastatic well-differentiated thyroid carcinoma treated with 200mCi $^{131}I$ were studied. There were false negative serum thyroglobulin values during TSH suppression or at anti-thyroglobulin antibody(+) and discrepancies between findings of whole body scan and serum thyroglobulin level. After one to five cycles of 200mCi $^{131}I$ therapy, complete remission and partial remission were achieved at 5.3% and 57.9%, respectively. We concluded that all of serum thyroglobulin, TSH, anti-thyroglobulin antibody, $^{131}I$ or $^{123}I$ whole body scan were necessary in follow up of metastatic well-differentiated thyroid carcinoma. Also, if there was no response after repetitive 200mCi $^{131}I$ therapy, higher doses of $^{131}I$ therapy should be considered.

  • PDF