• Title/Summary/Keyword: Scan Mirror

Search Result 46, Processing Time 0.028 seconds

Object Recognition using 3D Depth Measurement System. (3차원 거리 측정 장치를 이용한 물체 인식)

  • Gim, Seong-Chan;Ko, Su-Hong;Kim, Hyong-Suk
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.941-942
    • /
    • 2006
  • A depth measurement system to recognize 3D shape of objects using single camera, line laser and a rotating mirror has been investigated. The camera and the light source are fixed, facing the rotating mirror. The laser light is reflected by the mirror and projected to the scene objects whose locations are to be determined. The camera detects the laser light location on object surfaces through the same mirror. The scan over the area to be measured is done by mirror rotation. The Segmentation process of object recognition is performed using the depth data of restored 3D data. The Object recognition domain can be reduced by separating area of interest objects from complex background.

  • PDF

Design of the Step-stare Image Gathering System for an Aerial Reconnaissance (항공 정찰용 Step-stare 영상획득 시스템 설계)

  • Baek, Woonhyuk;Park, Jaeyoung;Ahn, Junghun;Lee, Jungsuk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.9
    • /
    • pp.813-820
    • /
    • 2014
  • This paper presents design and performance validation of a method for motion compensation using fast steering mirror. First of all, the schematics of the Electro Optical/Infra-Red (EO/IR) and step-stare image gathering system for an aerial reconnaissance are introduced. Because of the steering mirror with low inertia so called Back scan mechanism (BSM), the fast step-stare image gathering technique that is required for taking a high-definition still image will be realized. After then, the BSM hardware includes motors and feedback sensors are introduced. Also, the motion profile for BSM will be designed to compensate roll scan motion of the gimbals. At the end of this paper, designed profile and tracking performance of the EO/IR system with BSM will be validated through experiments.

Application of Photoacoustic Rapid Scan FTIR for the Determination of Kappa Number of Pulp

  • Dang Vinh Q.;Bhardwaj Nishi K.;Nguyen Kien L.
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2006.06a
    • /
    • pp.167-172
    • /
    • 2006
  • High-yield Pinus radiate kraft pulps with various Kappa number were produced from flow-through laboratory pulping. The samples were prepared and scanned using a rapid scan photoacoustic Fourier transform infrared (PAS-FTIR) spectrometer. A partial-least-squares (PLS) model was established based on the spectral data collected at different mirror velocities. The model was used to predict the Kappa number of the pulps and its robustness was statistically evaluated. The outcomes indicate that the PLS model can be used to predict the Kappa number of Pinus radiata kraft pulps with a high degree of accuracy provided that the moving mirror velocity is ${\leq}\;0.5cm/s$.

  • PDF

Thermal Imager Implementation Using Infrared Sensor (적외선 센서를 이용한 열상장비의 구현)

  • Yu, W.K.;Yoon, E.S.;Kim, C.W.;Song, I.S.;Hong, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1250-1254
    • /
    • 1992
  • This paper describes the designed and fabricated thermal imaging system with the SPRITE(Signal PRocessing in The Element) detector, operating in the 3-12 micron band. This system consists of an afocal telescope, a scan unit containing the SPRITE detector, an electronic processor unit and a cooler. The optical scan system utilizing rotating polygon and oscillating mirror, is 2-dimensional serial/parallel scan type using five elements of the detector. And the electronic processor unit performs digital scan conversion to reform the parallel data stream into serial analog data compatable with conventional RS-170 video. The scan field of view is 40 ${\times}$ 26.7 and the MRTD(Minium Resolvable Temperature Difference) is 0.6 K at 7.5 cycles/mm. The acquired thermal image indicates that this system has a satisfactory performance.

  • PDF

Electronic Processor Design for Thermal Imager with Serial/Parallel Scan type (직병렬 주사방식 일정장비의 신호처리기 설계 연구)

  • 송인섭;유위경;윤은석;홍영철;홍석민
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.1
    • /
    • pp.49-56
    • /
    • 1994
  • This paper describes the design principles and methods of electronic processor for thermal imager with the SPRITE detector, operating in the 8-12 micron band. The thermal imager consists of a optical scanner containing the detector and an electrical signal processor. The optical scanner utilizing rotating polygon and oscillating mirror, is 2-dimensional serial/parallel scan type using 5 elements of the detector. And the electronic processor has pre-processing of 5 chnanel's thermal signal from the detector, and performs digital scan conversion to reform the parallel data stream into serial analog data compatible with conventional RS-170 video. Through the designed electronic processor, we have acquired a satisfactory thermal image. And the MRTD (Minimum Resolvable Temperature Difference) is 0.5$^{\circ}$K at 7.5 cycles/mm.

  • PDF

High-speed angular-scan pulse-echo ultrasonic propagation imager for in situ non-destructive evaluation

  • Abbas, Syed H.;Lee, Jung-Ryul
    • Smart Structures and Systems
    • /
    • v.22 no.2
    • /
    • pp.223-230
    • /
    • 2018
  • This study examines a non-contact laser scanning-based ultrasound system, called an angular scan pulse-echo ultrasonic propagation imager (A-PE-UPI), that uses coincided laser beams for ultrasonic sensing and generation. A laser Doppler vibrometer is used for sensing, while a diode pumped solid state (DPSS) Q-switched laser is used for generation of thermoelastic waves. A high-speed raster scanning of up to 10-kHz is achieved using a galvano-motorized mirror scanner that allows for coincided sensing and for the generation beam to perform two-dimensional scanning without causing any harm to the surface under inspection. This process allows for the visualization of longitudinal wave propagation through-the-thickness. A pulse-echo ultrasonic wave propagation imaging algorithm (PE-UWPI) is used for on-the-fly damage visualization of the structure. The presented system is very effective for high-speed, localized, non-contact, and non-destructive inspection of aerospace structures. The system is tested on an aluminum honeycomb sandwich with disbonds and a carbon fiber-reinforced plastic (CFRP) honeycomb sandwich with a layer overlap. Inspection is performed at a 10-kHz scanning speed that takes 16 seconds to scan a $100{\times}100mm^2$ area with a scan interval of 0.25 mm. Finally, a comparison is presented between angular-scanning and a linear-scanning-based pulse-echo UPI system. The results show that the proposed system can successfully visualize defects in the inspected specimens.

3D CT Image Processing for 3D Printed Auricular Reconstruction of Unilateral Microtia Patient

  • Roh, Tae Suk;Yun, In Sik
    • Journal of International Society for Simulation Surgery
    • /
    • v.1 no.2
    • /
    • pp.80-82
    • /
    • 2014
  • Purpose Microtia is congenital anomaly of external ear and the reconstruction method for the external ear of microtia patient was based on autogenous costal cartilage framework. The application of 3D printing technique in medical science has made more possibility of human tissue restoration, and we tried to apply this technique in auricular reconstruction field. Materials and Methods As for unilateral microtia patient, the contralateral side ear is normal and reconstructive surgeon tried to mimic it for reconstruction of affected ear. So, we obtained facial CT scan of microtia patient and made mirror image of normal side ear. Moreover, to make the 3D scaffold based on the mirror image of normal ear and to apply this scaffold for the auricular reconstruction surgery, we included auriculocephalic sulcus and anterior fixation part. Results We could successfully obtain mirror image of normal ear, auriculocephalic sulcus and anterior fixation part for 3D scaffold printing. Conclusions Using this CT image processing and 3D printing technique, we will be able to make the scaffold for auricular reconstruction of unilateral microtia patient, and perform auricular reconstruction in near future.

A Study on Laser Scanning System Using Multi-Facet Hologon (다중-FACET 홀로곤을 이용한 레이저 주사시스템에 관한 연구)

  • Shin, Kwang-Yong;Kim, Nam;Park, Han-Kyu
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.5
    • /
    • pp.566-571
    • /
    • 1988
  • Laser scanning system using a hologram is simpler in optical system, lower in cost than using a polygon. In this paper, a thick hologram is fabricated for the underfilled transmission disk type with a merit of wabble insensitivity to vibration. High diffraction efficiency over 50% is obtained using silver halide recording material. The two-dimensional scan pattern with 13 scan-line is made by 7-facet hologon and mirror system. This system can be practically applied to POS(Point of Sale) bar-code symbol reader.

  • PDF