• 제목/요약/키워드: Scaling test

검색결과 428건 처리시간 0.021초

스케일링 건강보험 급여화에 대한 산재환자의 인식도 (Recognition about national health insurance of dental scaling in industry accident injury patients)

  • 이혜순;이경희
    • 한국치위생학회지
    • /
    • 제13권4호
    • /
    • pp.561-568
    • /
    • 2013
  • Objectives : The purpose of this study is to examine the recognition and needs on the national health insurance coverage of scaling in industry accident injury patients. National health insurance coverage of dental scaling will start in September, 2013. Methods : Subjects were 649 industrial injury patients and they completed self-reported questionnaire. Data were analysed using SPSS version 20.0 for percentage, chi-square test, t-test, ANOVA, post-hoc Scheffe test, and Pearson's correlation coefficient. Results : Recognition on national health insurance coverage of dental scaling was not fully known to industrial injury patients (24.5%). Highly educated and high income workers seemed to recognize national health insurance coverage of dental scaling (p<.001). Recognition for national health insurance coverage of dental scaling revealed a significance (r=.576, p<.001). Most of the industrial injury workers thought that 50,000 to 100,000 Korean Won of dental scaling fee is reasonable. The coverage of dental scaling should be more than twice over 20 years old. Conclusions : It is necessary to encourage the patients to take regular dental scaling checkup and make them know the health insurance coverage of scaling. The preventive oral health care may improve oral health care and quality of life.

Evaluation of Pain Reduction and Clinical Efficacy of Feedback-Controlled Ultrasonic Scaler

  • Min-ju Kim;Hee-jung Lim;Myoung-hee Kim;Young-sun Hwang;Im-hee Jung
    • 치위생과학회지
    • /
    • 제23권2호
    • /
    • pp.176-184
    • /
    • 2023
  • Background: Recently, a piezoelectric ultrasonic scaler based on a feedback control mechanism was introduced for pain relief. This study aimed to investigate the effects of a new ultrasonic scaler in reducing pain and discomfort in adults. Methods: A newly introduced ultrasonic scaler (Master 700®) was used as the test device and a conventional ultrasonic scaler device (PIEZON®) was used as the control device. Forty-one healthy adults visited the dental clinic for dental scaling but did not undergo scaling or periodontal treatment within 6 months. Intraoral examinations were performed before scaling and 3 months later; before scaling, both devices were randomly assigned on the left or right side of each dentition (split-mouth model) and scaling was performed by a registered dental hygienist. The levels of pain and discomfort during scaling were evaluated subjectively and objectively using the visual analog scale (VAS) and physiological monitoring of the heart rate (HR), respectively. Time was measured for each device. Results: All clinical indicators, except bleeding on probing, significantly improved with both devices. The treatment times were 7 minutes, 13 minutes (control) and 6 minutes, 59 minutes (test). VAS scores for pain were 4.89±2.12 (control) and 4.58±2.77 (test) points out of 10; for noise, these were 4.68±2.33 (control) and 4.55±2.55 (test), and for vibration, the values were 4.26±2.0 (control) and 4.18±2.48 (test). HR averages were 72.34±3.39 (control) and 75.97±9.78 (test) beats/min. No statistically significant differences were observed between the devices. Conclusion:The pain, discomfort levels, and scaling time of the new piezoelectric ultrasonic scaler did not differ from those of the conventional device. Further research and development are necessary for more prominent pain-relief effects of scaling devices.

Scaling analysis of the pressure suppression containment test facility for the small pressurized water reactor

  • Liu, Xinxing;Qi, Xiangjie;Zhang, Nan;Meng, Zhaoming;Sun, Zhongning
    • Nuclear Engineering and Technology
    • /
    • 제53권3호
    • /
    • pp.793-803
    • /
    • 2021
  • The small PWR has been paid more and more attention due to its diversity of application and flexibility in the site selection. However, the large core power density, the small containment space and the rapid accident progress characteristics make it difficult to control the containment pressure like the traditional PWR during the LOCA. The pressure suppression system has been used by the BWR since the early design, which is a suitable technique that can be applied to the small PWR. Since the configuration and operating conditions are different from the BWR, the pressure suppression system should be redesigned for the small PWR. Conducting the experiments on the scale down test facility is a good choice to reproduce the prototypical phenomena in the test facility, which is both economical and reasonable. A systematic scaling method referring to the H2TS method was proposed to determine the geometrical and thermohydraulic parameters of the pressure suppression containment response test facility for the small PWR conceptual design. The containment and the pressure suppression system related thermohydraulic phenomena were analyzed with top-down and bottom-up scaling methods. A set of the scaling criteria were obtained, through which the main parameters of the test facility can be determined.

치과위생사와 환자의 치석제거 실태와 분쟁에 대한 견해 차이 (Differences in view of dental hygienist and patient's scaling actual condition and disputes)

  • 성미경;강현경;김유린
    • 한국치위생학회지
    • /
    • 제20권5호
    • /
    • pp.623-633
    • /
    • 2020
  • Objectives: Since scaling has been covered by insurance, the number of patients undergoing scaling has increased. Simultaneously, legal disputes around scaling have increased. Therefore, this study was aimed at comparing the differences between the perceptions of dental hygienists and patients regarding the scaling procedure and providing dental hygienists with basic data to find ways to reduce disputes arising from these differences. Methods: A survey was conducted on 119 dental hygienists working in Busan and the South Gyeongsang Province and 110 patients who visited hospitals for scaling. Frequency analyses were performed for dental hygienists' scaling behavior and patient discomfort during scaling. The independent t-test and chi-square test were performed to compare the perceptions of dental hygienists and patients regarding the scaling procedure. Results: Polishing after scaling was performed according to 70.1% of dental hygienists but only 29.9% of patients. Oral health education was provided according to 20.4% of dental hygienists, while 79.6% of patients said that they received oral health education at the Dentiform. The scaling time was reported to be shorter by patients than by dental hygienists. Both dental hygienists and patients said that legal action was required if problems occurred during scaling, and the refund standard was that patients needed it more than dental hygienists. Conclusions: There are differences between the perceptions of dental hygienists and patients regarding scaling. Dental hygienists should identify these differences and try to prevent conflicts or disputes with patients around scaling.

지진 기록의 확대(Scaling) 기법과 압력토오 말뚝모형실험에의 적용 (Scaling Technique of Earthquake Record and its Application to Pile Load Test for Model Driven into Pressure Chamber)

  • 최용규
    • 한국지반공학회지:지반
    • /
    • 제12권2호
    • /
    • pp.19-32
    • /
    • 1996
  • 시간영역의 지진 가속도-시간 이력을 주파수 영역의 courier 진폭-주파수 이력으로 변화시키는 Trifunac의 경험적 모델을 기초로 하여 지진 관측소에서 측정된 임의 규모의 실제 지진기록들을 필요한 규모의 지진기록으로 유사화시키는 지진 확대 (scaling) 기법을 제안하였다. 또한, 지진 규모(M) 5.6의 지진기록을 이용하여 지진 규모(M) 8.0의 유사지진을 작성하여 동적 재하 시험 장치에 적용가능하도록 하였다. 지진 확대 (scaling) 기법은 MMI(modified mercalli intensity), 지진기록 부지의 조건,진앙거리,지진 가속도 성분의 방향, 해석의 신뢰도 등을 고려할 수 있으며, 다양한 지진 기록들에 적용가능하였다.유사지진은 수평방향의 성분들만을 고려하여 작성되었다. 압력토조내에 설치된 모형인장말뚝과 개단압출말뚝에 대한 유사지진 진동에 의한 동적 말뚝재하시험이 가능하였다. 정적 말뚝재하시험시 인장말뚝과 압축말뚝의 거동은 매우 상이하였는데, 인장말뚝은 2~3회의 급작스런 미끄러짐 변위를 수반하였다. 또한, 유사 지진 진동중 인장말뚝과 개단압축말뚝의 거동특성은 매우 상이하였으며, 지지력 감소특성도 크게 달랐다.

  • PDF

CANDU-6 원자로 감속재 열수력 개별영향실험을 위한 축소화 기법에 따른 1/8 축소형 HU-KINS 설계 (Design of the 1/8 Scaled HU-KINS Based on the Scaling Laws for the Experimental Investigation of Thermal-Hydraulic Effect of CANDU-6 Moderator)

  • 이재영;김만웅;김남석
    • 대한기계학회논문집B
    • /
    • 제30권9호
    • /
    • pp.825-833
    • /
    • 2006
  • To investigate the moderator coolability for CANDU-6 reactors, a test facility (HU-KINS) has been manufactured as a 1/8 scaled-down of a calandria tank. In the design of the test facility, a scaling law was developed in such a way to consider the thermal-hydraulic characteristics of a CANDU-6 moderator. The proposed scaling law takes into consideration of the energy conservation, the dynamic similitude such as dimensionless numbers, Archimedes number (Ar) and Reynolds number (Re), and thermal-hydraulic properties similitude. Using this proposed scaling law, the thermal-hydraulic scaling analyses of similar test facilities such as the SPEL (1/10 scale) and the STERN (1/4 scale), have been identified. As a result, in the case of the SPEL, while the energy conservation is well defined, the similarities of Ar and the heat density are not well considered. As for the similarity of the STERN, while both the energy conservation and the characteristics of Ar are well defined, the heat density is not. In the meanwhile, the HU-KINS test facility with 1/8 length scaled-down is well similitude in compliance with all similarities of the energy conservation, the fluid dynamics and thermal-hydraulic properties. To verify the adequacy of the similarities in terms of thermal-hydraulics, a computational fluid dynamic (CFD) analysis has been conducted using the CFX-5 code. As the results of the CFD analyses, the predicted flow patterns and variation of axial properties inside the calandria tank are well consistant with those of previous studies performed with FLUENT and this implies that the present scaling method is acceptable.

퍼지 PI scaling factor의 분석적인 유도방법에 관한 연구 (A Study on an Analytical Approach to the Derivation of Fuzzy PI Scaling Factor)

  • 전기영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.460-463
    • /
    • 2000
  • Fuzzy logic control(FLC) has been studied extensively and has been applied in various applications. The most popular control strategy takes the Fuzzy Proportional-Integral(FPI) form while systematic methods have been developed to derive the fuzzy rules and membership functions the choice of the scaling factors remains an open problem, In this paper an analytical FPI scaling factor determining method is derived based on the functional equivalence of the PI and FPI controllers. Simulation have been carried out with a brushless DC motor drive system as test-bed the obtained results drive system as test-bed the obtained results have verified that the derived method is applicable to both the initial choice and further tuning of the FPI scaling factors.

  • PDF

가스터빈 시험장치를 이용한 구성품 성능선도 축척기법에 관한 연구 (Study on Component Map Scaling Technique Using a Gas Turbine Test Unit)

  • 공창덕;고성희;기자영
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제20회 춘계학술대회 논문집
    • /
    • pp.105-109
    • /
    • 2003
  • 가스터빈 시험장치의 실험 데이터로부터 얻어진 일부 성능 데이터를 이용하여 구성품 성능선도 (component characteristic)를 축척(scaling)하는 새로운 방법을 제안하였다. 성능해석의 오차를 최소화하기 위하여 실제 실험 데이터로부터 몇 개의 작동점들에 일치하는 일련의 구성품 성능선도들을 구하고 다항식(polynomial)을 이용하여 새롭게 성능선도를 구성하는 축척방법을 제안하였으며, 이때 얻어진 성능선도를 이용하여 탈설계점 성능해석을 수행하였다. 해석 결과 기존의 축척방법으로 얻어진 성능선도를 이용한 경우 설계점을 제외한 대부분의 탈설계점에서의 성능은 실제 엔진 성능과 잘 일치하지 않았다. 그러나 새로운 축척방법에 의해 얻어진 성능선도를 이용한 경우에는 최대 5% 이내의 오차율을 보였다.

  • PDF

피동 주입 시험 장치의 척도 해석 및 설계 방법론 연구 (Study on Scaling Analysis and Design Methodology of Passive Injection Test Facility)

  • 배황;이민규;류성욱;신수재;김영인;이성재;박현식
    • 한국유체기계학회 논문집
    • /
    • 제19권5호
    • /
    • pp.50-60
    • /
    • 2016
  • A design methodology of the modeled test facility to conserve an injection performance of a passive safety injection system is proposed. This safety injection system is composed of a core makeup tank and a safety injection tank. Individual tanks are connected with pressure balance line on the top side and injection line on the bottom side. It is important to conserve the scaled initial injection flow rate and total injection time since this system can be operated by small gravity head without any active pumps. Differential pressure distribution of the injection line induced by the gravity head is determined by the vertical length and elevation of each tank. However, the total injection time is adjustable by the flow resistance coefficient of the injection line. The scaling methodology for the tank and flow resistance coefficient is suggested. A key point of this test facility design is a scaling analysis for the flow resistance coefficient. The scaling analysis proposed on this paper is based on the volume scaling law with the same vertical length to the prototype and can be extended to a model with a reduced vertical length. A set of passive injection test were performed for the tanks with the same volume and the different length. The test results on the initial flow rate and total injection time showed the almost same injection characteristics and they were in good agreement with the design values.