• 제목/요약/키워드: Scaler

검색결과 135건 처리시간 0.031초

Real-Time Continuous-Scale Image Interpolation with Directional Smoothing

  • Yoo, Yoonjong;Shin, Jeongho;Paik, Joonki
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제3권3호
    • /
    • pp.128-134
    • /
    • 2014
  • A real-time, continuous-scale image interpolation method is proposed based on a bilinear interpolation with directionally adaptive low-pass filtering. The proposed algorithm was optimized for hardware implementation. The ordinary bi-linear interpolation method has blocking artifacts. The proposed algorithm solves this problem using directionally adaptive low-pass filtering. The algorithm can also solve the severe blurring problem by selectively choosing low-pass filter coefficients. Therefore, the proposed interpolation algorithm can realize a high-quality image scaler for a range of imaging systems, such as digital cameras, CCTV and digital flat panel displays.

산업용 컴퓨터용 입력 및 표시장치 인터페이스 구현에 대한 연구 (A Study on input and display interface for industrial computer)

  • 조영석;김재진
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2015년도 제52차 하계학술대회논문집 23권2호
    • /
    • pp.196-197
    • /
    • 2015
  • 본 논문에서는 산업용 컴퓨터에서 사용할 마우스와 터치스크린을 이용한 산업용 컴퓨터 인터페이스 장치 구현에 대하여 연구하였다. 산업용 제어 현장에서 사용되는 제어용 컴퓨터의 입출력 장치는 확장성을 고려하여 설계되지 않았기 때문에 현재의 컴퓨터 주변장치를 직접 사용할 수 없는 경우가 대부분이다. 본 논문에서는 산업용컴퓨터에서 사용되는 라이트펜과 모니터를 현재 주로 사용하는 마우스와 LCD모니터로 입출력이 가능하도록 하는 인터페이스 장치를 개발하여, 생산 공정에서 사용하는 산업용 컴퓨터의 활용도를 높이고자 한다. 산업용 컴퓨터 인터페이스장치는 ARM 기반 MPU를 이용하여 영상 신호와 외부 입력장치의 자료를 처리하고, CPLD에서 생성된 신호를 제어용 컴퓨터로 입력하였다. 제어컴퓨터의 영상신호를 다양한 모니터와 인터페이스 할 수 있도록 비디오 스케일러(Video Scaler)를 사용하였다. 구현한 인터페이스 장치는 다양한 장치들을 산업용컴퓨터에서 사용이 가능함을 보였다.

  • PDF

LCD TV의 핵심기술 선정방법에 관한 연구 (The Analysis of LCD TV's Core Technology using by Analytic Hierarchy Process)

  • 곽수환
    • 한국전자통신학회논문지
    • /
    • 제9권5호
    • /
    • pp.575-582
    • /
    • 2014
  • 본 논문은 LCD TV의 다양한 기술 중 어떤 것을 자체개발 하고, 어떤 것을 외부로부터 조달하여야 할 것인지를 결정할 수 있는 프레임웍을 제공하고, 이를 검정하였다. AHP를 이용하여 분석한 결과, 중요한 기술로는 Scaler chip, LCD panel, MPEG decoder, Video decoder 등의 순으로 나타났으며, 이들 상위 부품들은 삼성전자에서 직접 자체 생산이 이루어지고 있는 중요한 핵심부품으로 밝혀짐에 따라 본 논문의 타당성이 검정되었다고 할 수 있겠다. 본 논문을 통해 기업이 자체 개발해야만 하는 핵심부품을 선정하는데 도움을 줄 수 있을 것으로 기대된다.

적응적인 가변 커널 길이의 Cubic Convolution Scaler를 이용한 화면 해상도 변화기 (Adaptive cubic convolution scaler using variable kernel length)

  • 정연경;문지혜;한종기
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2013년도 추계학술대회
    • /
    • pp.12-15
    • /
    • 2013
  • 최근 UHD TV 출시와 HD급 영상의 보편화로 영상에 대한 해상도 변경 기술의 중요성이 높아지고 있다. 본 논문에서는 기존의 cubic convolution 기법을 응용하여, 영역별 특성에 따라 적응적인 가변 커널 길이의 cubic convolution으로 화면 해상도를 변환하는 기법을 제안한다. 제안하는 기법은 영상의 화질을 개선시키면서도 상황에 따라 하드웨어의 line memory를 절약할 수 있도록 설계를 하여 화질 개선뿐만이 아니라 하드웨어적으로도 더 효율적으로 사용이 가능하다. 또 tuning parameter 를 최적화 하는 방법을 통해 기존의 cubic convolution 기법보다 더 좋은 화질의 영상을 얻을 수 있다.

  • PDF

Weighted DCT-IF for Image up Scaling

  • Lee, Jae-Yung;Yoon, Sung-Jun;Kim, Jae-Gon;Han, Jong-Ki
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권2호
    • /
    • pp.790-809
    • /
    • 2019
  • The design of an efficient scaler to enhance the edge data is one of the most important issues in video signal applications, because the perceptual quality of the processed image is sensitively affected by the degradation of edge data. Various conventional scaling schemes have been proposed to enhance the edge data. In this paper, we propose an efficient scaling algorithm for this purpose. The proposed method is based on the discrete cosine transform-based interpolation filter (DCT-IF) because it outperforms other scaling algorithms in various configurations. The proposed DCT-IF incorporates weighting parameters that are optimized for training data. Simulation results show that the quality of the resized image produced by the proposed DCT-IF is much higher than that of those produced by the conventional schemes, although the proposed DCT-IF is more complex than other conventional scaling algorithms.

위상 교정 디지털 필터를 이용한 고성능/고화질 이미지 축소기 시스템 개발 및 IC 구현 (System Development and IC Implementation of High-performance Image Downscaler using Phase-correction Digital Filters)

  • Lee, Y.;O. Moon;Lee, H.;Lee, B.;B. Kang;C. Hong
    • 융합신호처리학회 학술대회논문집
    • /
    • 한국신호처리시스템학회 2000년도 하계종합학술대회논문집
    • /
    • pp.265-268
    • /
    • 2000
  • In this paper, we propose an algorithm, an optimized architecture, and an implementation for an improved performance of image downscaler. The proposed downscaler uses two-dimensional digital filters for horizontal and vertical scalings, respectively. It also improves scaling precisions and decreases the loss of data, compared with the 1/32 scaler 〔1〕. In order to achieve the optimization, the digital filters are implemented by the multiplexer -adder type scheme 〔2〕. The scaler is designed by using the Verilog-HDL. It is synthesized into gates by using the Samsung 0.35 um STD90 TLM library.

  • PDF

Characteristics of the molar surface after removal of cervical enamel projections: comparison of three different rotating instruments

  • Ko, Min-Jeong;Cho, Chan-Myung;Jeong, Seong-Nyum
    • Journal of Periodontal and Implant Science
    • /
    • 제46권2호
    • /
    • pp.107-115
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate and compare tooth surface characteristics in extracted human molars after cervical enamel projections (CEPs) were removed with the use of three rotating instruments. Methods: We classified 60 extracted molars due to periodontal lesion with CEPs into grade I, II, or III, according to the Masters and Hoskins' criteria. Each group contained 20 specimens. Three rotating instruments were used to remove the CEPs: a piezoelectric ultrasonic scaler, a periodontal bur, and a diamond bur. Tooth surface characteristics before and after removal of the projections were then evaluated with scanning electron microscopy (SEM). We analyzed the characteristics of the tooth surfaces with respect to roughness and whether the enamel projections had been completely removed. Results: In SEM images, surfaces treated with the diamond bur were smoothest, but this instrument caused considerable harm to tooth structures near the CEPs. The piezoelectric ultrasonic scaler group produced the roughest surface but caused less harm to the tooth structure near the furcation. In general, the surfaces treated with the periodontal bur were smoother than those treated with the ultrasonic scaler, and the periodontal bur did not invade adjacent tooth structures. Conclusions: For removal of grade II CEPs, the most effective instrument was the diamond bur. However, in removing grade III projections, the diamond bur can destroy both adjacent tooth structures and the periodontal apparatus. In such cases, careful use of the periodontal bur may be an appropriate substitute.

치과 치료용 초음파 스케일러의 성능 및 안정성에 대한 실험 평가 (Experimental Evaluation of the Performance and Stability of an Ultrasonic Scaler for Dental Treatment)

  • 사민우;고태조;전금상;이종민;김종영
    • 대한기계학회논문집A
    • /
    • 제41권1호
    • /
    • pp.13-19
    • /
    • 2017
  • 치과 분야에서 초음파를 이용한 수술기 및 스케일러의 사용은 꾸준하게 증가하고 있다. 이때 개발된 기기의 성능 및 안정성은 시술 받는 환자에게 결정적인 요소로 작용하기 때문에 상업화 전에 반드시 시험 평가되어야 한다. 그래서 골 절단 및 치아 스케일링 평가를 수행할 수 있는 핸드피스 이송 시스템을 자체 개발하여 사용하였다. 본 연구의 목표는 초음파 스케일러 팁을 이용하여 치아 손상 정도를 평가하기 위함이다. 추가적으로 초음파 기기의 열 발생 및 소음에 대한 측정을 수행해보았다. 결과적으로 Ultrasonic NX 기기의 높은 출력은 실험을 통한 치아에 심각한 손상을 입힐 수 있지만 열 화상 카메라를 이용한 열 발생 및 소음 측정을 통해 안정적인 범위에 있었다.

The effect of pretreating resorbable blast media titanium discs with an ultrasonic scaler or toothbrush on the bacterial removal efficiency of brushing

  • Koh, Minchul;Park, Jun-Beom;Jang, Yun-Ji;Ko, Youngkyung
    • Journal of Periodontal and Implant Science
    • /
    • 제43권6호
    • /
    • pp.301-307
    • /
    • 2013
  • Purpose: This in vitro study was performed to assess the adherence of Porphyromonas gingivalis to a resorbable blast media (RBM) titanium surface pretreated with an ultrasonic scaler or toothbrush and to evaluate the effects of the treatment of the RBM titanium discs on the bacterial removal efficiency of brushing by crystal violet assay and scanning electron microscopy. Methods: RBM titanium discs were pretreated with one of several ultrasonic scaler tips or cleaned with a toothbrush. Then the titanium discs were incubated with P. gingivalis and the quantity of adherent bacteria was compared. The disc surfaces incubated with bacteria were brushed with a toothbrush with dentifrice. Bacteria remaining on the disc surfaces were quantified. Results: A change in morphology of the surface of the RBM titanium discs after different treatments was noted. There were no significant differences in the adherence of bacteria on the pretreated discs according to the treatment modality. Pretreatment with various instruments did not produce significant differences in the bacterial removal efficiency of brushing with dentifrice. Conclusions: Within the limits of this study, various types of mechanical instrumentation were shown to cause mechanical changes on the RBM titanium surface but did not show a significant influence on the adherence of bacteria and removal efficiency of brushing.