• 제목/요약/키워드: Scaled model

검색결과 961건 처리시간 0.033초

풍력터빈시뮬레이터와 매트릭스 컨버터를 적용한 PMSG 풍력발전 시스템 모델 개발 (Development of PMSG Wind Power System Model using Wind Turbine Simulator and Matrix Converter)

  • 윤동진;한병문;차한주;이옥용;최남섭
    • 전기학회논문지
    • /
    • 제58권6호
    • /
    • pp.1130-1137
    • /
    • 2009
  • This paper describes a scaled model development of PMSG wind power system using wind turbine simulator and matrix converter. The wind turbine simulator, which consists of an induction motor with vector drive, calculates the output torque of a specific wind turbine using simulation software and sends the torque signal to the vector drive after scaling down the calculated value. The operational feasibility of interconnected PMSG system with matrix converter was verified by computer simulations with PSCAD/EMTDC software. The feasibility of hardware implementation was conformed by experimental works with a laboratory scaled-model of wind power system. The simulation and experimental results confirm that matrix converter can be effectively applied for the PMSG wind power system.

A Distribution Automation System Simulator for Training and Research

  • Gupta R. P.;Srivastava S. C.
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권2호
    • /
    • pp.159-170
    • /
    • 2005
  • This paper presents the design and development of a scaled down physical model for power Distribution Automation (DA) system simulation. The developed DA system simulator is useful in providing hands-on experience to utility engineers / managers to familiarize with the DA system and gain confidence in managing the power distribution system from the computer aided distribution control center. The distribution automation system simulator can be effectively used to carry out further research work in this area. This also helps the undergraduate and graduate students to understands the power distribution automation technology in the laboratory environment. The developed DA simulator has become an integral part of a distribution automation lab in the Electrical Engineering Department at Indian Institute of Technology Kanpur in India.

입자 유동 해석(PFC)을 통한 근접터널의 거동에 관한 연구 (A Study on the Behavior of a Closely-spaced Tunnel by Using Particle Flow Code)

  • 서병욱;조선아;정선아;이석원
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.159-169
    • /
    • 2008
  • In general, it is considered that a pillar between closely-spaced tunnel is sensitive for stress concentration. Stability of a pillar is key factor for excavation of closely-spaced tunnel. In this paper, the study is focused on tracing the behaviors, displacement and plotting damages around tunnels that is modelled with Particle Flow Code, $PFC^{2D}$. Parametric study was performed with changing distance between center of tunnels and coefficient of earth pressure(K). Scaled-model tests were also carried out to validate a numerical analysis model. It was found that $PFC^{2D}$ could show dynamic visualized result in quite good agreement with the experimental test.

  • PDF

축소 건물모델의 모달 파라미터 추정에 관한 연구 (A Study on the Modal Parameters of the scaled building structure)

  • 박해동;박진일;최현;김두훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.571-575
    • /
    • 2000
  • The physical properties of the spatial model, mass, stiffness and damping matrix, can be defined by a specific natural frequency, damping ratio and mode shape. These modal parameters can be determined from a set of frequency response function(FRF) measured by exciting the structure and measuring the responses at various points around the structure. In this paper, The Transfer Matrix is obtained by experimental modal analysis for the 3-story scaled building model which TMD is installed on top and the physical properties of the spatial model is determined using the residue matrix and the location of poles from FRF measurement using polynomial curve fitting methods.

  • PDF

단일 유연 링크 매니퓰레이터의 복합 퍼지 제어 (Composite Fuzzy Control of a Single Flexible Link Manipulator)

  • 김재승;이수한
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.353-353
    • /
    • 2000
  • To control a light weight flexible manipulator, a composite fuzzy controller is proposed. The controller is designed based on two time scaled models. A singular perturbation technique is applied for deriving the models. The proposed controller, however, does not use the complex equilibrium manifold equations, which are usually needed in the controller based on the two time scaled models. The controller for a slow sub-model and a fast sub-model are T-S type fuzzy controllers, which use 3 linguistic variables for each sub-model. A step trajectory is used in simulations as a reference trajectory of joint motions. The results of simulations with the proposed controller show excellent damping of flexible motions compared to a controller with derivative control of flexible motions.

  • PDF

Pressure Characteristics on Korean High-Speed Railway Acoustic Screen Using 1/61 Scaled-Down Moving Model Rig

  • Jang, Yong-Jun;Kim, Hag-Beom;Jung, Woo-Sung;Kim, Dong-Hyeon
    • International Journal of Railway
    • /
    • 제2권2호
    • /
    • pp.93-97
    • /
    • 2009
  • The experiments for aerodynamic characteristics of railway acoustic screen are performed using 1/61 scaled-down moving model rig facility which employs an axis symmetry and one wire guidance method. The launching mechanism is an air-gun type. The train model for the experiment is the high speed train (Korea Train Express: KTX) and the tested speed is about 300 km/h. The tested train length is 61 em which is corresponding to two units of KTX train. The cross sectional area and weight of train model are 0.00264 $m^2$ and 287 g, respectively. The Reynolds number based on the model train length is $1.2{\times}10^7$. The strength of pressure wave is measured using piezo typed pressure sensor. The measured pick value of pressure was as high as 365 Pa in the shortest gap between the acoustic screen and model train. The measured pressure is well compared with the field test data of mc 779-1 [2] values. However, the experimental data were slightly lower than the mc 779-1 values. The results show the model test can be used as a substitute for the field test.

  • PDF

송전철탑 부분축소모형의 실험적 연구 (Experimental Study of Steel Transmission Tower using Partially Scaled Model)

  • 김종민;김승준;박종섭;강영종
    • 한국강구조학회 논문집
    • /
    • 제22권4호
    • /
    • pp.335-344
    • /
    • 2010
  • 본 논문에서는 실험적 연구를 통해 송전철탑의 극한 거동을 규명하고 보-트러스 구조해석모델의 적합성을 평가하였다. 해석적 연구를 통해 충분히 검증된 송전철탑의 부분 축소 모형을 실험체로 제작하였으며, 이를 극한파괴가 발생할 때 까지 수평방향으로 가력하였다. 그 결과 기존 연구에서 제안된 구조해석모델을 실험적으로 검증하였으며, 송전철탑의 극한 내력 또한 해석적 연구 결과와 잘 부합하는 것으로 판명되었다. 그리고 각재부 및 각재부 제1윗절간 주주재에서 파괴가 일어난 후 인접 부재로 전이되는 송전철탑 구조물 파괴 모드의 유사성을 확인하였다.

이산요소법을 이용한 수치해석에서의 상사성 이론의 적용성 검토 (Feasibility Study on Similarity Principle in Discrete Element Analysis)

  • 윤태영;박희문
    • 한국도로학회논문집
    • /
    • 제18권2호
    • /
    • pp.51-60
    • /
    • 2016
  • PURPOSES : The applicability of the mechanics-based similarity concept (suggested by Feng et al.) for determining scaled variables, including length and load, via laboratory-scale tests and discrete element analysis, was evaluated. METHODS: Several studies on the similarity concept were reviewed. The exact scaling approach, a similarity concept described by Feng, was applied in order to determine an analytical solution of a free-falling ball. This solution can be considered one of the simplest conditions for discrete element analysis. RESULTS : The results revealed that 1) the exact scaling approach can be used to determine the scale of variables in laboratory tests and numerical analysis, 2) applying only a scale factor, via the exact scaling approach, is inadequate for the error-free replacement of small particles by large ones during discrete element analysis, 3) the level of continuity of flowable materials such as SCC and cement mortar seems to be an important criterion for evaluating the applicability of the similarity concept, and 4) additional conditions, such as the kinetics of particle, contact model, and geometry, must be taken into consideration to achieve the maximum radius of replacement particles during discrete element analysis. CONCLUSIONS : The concept of similarity is a convenient tool to evaluate the correspondence of scaled laboratory test or numerical analysis to physical condition. However, to achieve excellent correspondence, additional factors, such as the kinetics of particles, contact model, and geometry, must be taken into consideration.

쌍굴터널 간 이격거리가 터널 안정성에 미치는 영향에 관한 모형실험 연구 (Influence of Pillar Width on the Stability of Twin Tunnels Using Scaled Model Tests)

  • 김종우
    • 터널과지하공간
    • /
    • 제25권5호
    • /
    • pp.423-434
    • /
    • 2015
  • 본 연구에서는 필러 폭과 모형재료의 강도가 서로 다른 등방성 및 이방성 암반 내 쌍굴터널의 모형실험을 통해 얻어진 터널의 변형과 필러부 균열이 발생한 이축압력 자료를 이용하여 터널 간 이격거리, 지반 강도, 등방성 및 이방성이 터널 안정성에 미치는 영향을 알아보았다. 모형재료의 일축압축강도에 대한 균열개시압력의 백분율을 균열개시압력비율이라고 정의할 경우, 강도가 큰 지반에 시공되는 쌍굴터널은 강도가 작은 지반에 비하여 균열개시압력 값은 크지만, 균열개시압력비율은 작게 나타났다. 이에 비해 필러 폭이 큰 쌍굴터널은 필러 폭이 작은 경우에 비하여 균열개시압력 값이 클 뿐 아니라 균열개시압력비율도 크게 나타나, 필러 폭은 쌍굴터널 안정성에 영향을 미치는 주된 요소로 판단된다. 지반의 등방성과 이방성 여부도 터널 안정성에 영향을 미쳤는데, 이방성 모형은 등방성 모형에 비해 균열개시압력과 균열개시압력비율이 작을 뿐 아니라 필러부에 존재한 기존 불연속면을 따라 균열이 발생하였다.

이방성 암반내 쌍굴터널의 안정성에 대한 모형실험 연구 (A Study on the Stability of Twin Tunnels in Anisotropic Rocks Using Scaled Model Tests)

  • 김종우;김명균
    • 터널과지하공간
    • /
    • 제22권3호
    • /
    • pp.205-213
    • /
    • 2012
  • 본 연구에서는 $30^{\circ}$ 경사진 층리면을 가진 이방성 암반내 위치한 쌍굴터널에서 터널간 이격거리와 터널 단면의 형상이 서로 다른 다섯 가지 모형에 대해 측압계수 2의 하중조건으로 축소모형실험을 실시하였다. 실험을 통해 모형별 균열개시압력과 터널 주변지반의 변형거동을 조사하였으며, 이 조건들이 터널의 안정성에 어떠한 영향을 미치는지를 알아보았다. 터널간 이격거리가 작은 모형일수록 필라에서는 층리면을 따른 전단파괴가 발생하였으며 낮은 압력수준에서 균열이 발생하여 터널의 안정성은 상대적으로 작은 것으로 평가되었다. 사심아치형, 원형, 반원아치형 터널 모형들에 대한 실험에서 반원아치형 터널이 가장 작은 균열개시압력을 보여 터널 안정성이 가장 작게 나타났으며, 원형 터널의 안정성이 가장 크게 나타났다. 또한, 사심아치형 터널의 변형거동은 원형 터널과 반원아치형 터널의 중간적인 형태를 나타내었으며 터널 안정성도 중간정도에 해당하였다. FLAC을 사용한 수치해석 결과는 모형실험의 결과와 정성적으로 부합하였다.