• Title/Summary/Keyword: Scaled Model Test

Search Result 367, Processing Time 0.027 seconds

Similitude Law on Small Scaled RC Model for Seismic Performance Evaluation Tests (내진성능평가실험을 위한 철근콘크리트 축소모형 상사법칙)

  • Lee, Do-Keun;Cho, Jae-Yeol
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.455-456
    • /
    • 2009
  • Although pseudo-dynamic test and shaking table test have been performed using small scale models to evaluate the seismic performance of RC structures, researches on similitude law are not sufficient. This study presents a reasonable similitude law for improvement of economical efficiency and reliability.

  • PDF

A Practical Estimation of Static Stability of a Hovercraft

  • Park, Sun-Ho;Heo, Jae-Kyung;Yu, Byeong-Seok
    • Journal of Ship and Ocean Technology
    • /
    • v.10 no.3
    • /
    • pp.27-35
    • /
    • 2006
  • The static stability of a high-speed hovercraft is estimated by model tests, simplified restoring moment equations and CFD. Well-known methods to increase the stability of hovercrafts are introduced. Roll and pitch moments of a scaled model with a skirt system are measured over inclination angles. The tests are performed on cushion at zero speed both on-land and over-water. To predict the static stability performance, simple restoring moment equations and CFD approach are introduced. Both shows a quantitative difference from the model test results, however, could be used as a design tool for relative comparison prior to model tests.

Shaking Table Test of Rectangular Liquid Container with Base-Isolation System (사각형 면진유체저장조의 진동대실험)

  • 전영선;최인길
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1995.04a
    • /
    • pp.122-129
    • /
    • 1995
  • The seismic behavior of a rectangular liquid container with high damping laminated rubber bearing is investigated through the scaled model tests. The results are compared with those for non-isolated model, and those by analytical methods. It is shown that the optimum dynamic properties of isolation system can reduce the acceleration response in the superstructure significantly and prevent the amplification of sloshing height.

  • PDF

A Running Stability Test of 1/5 Scaled Bogie Using Small Scale Derailment Simulator (소형탈선시뮬레이터를 이용한 1/5 축소대차의 주행안정성 시험)

  • Eom, Beom-Gyu;Lee, Se-Yong;Lee, Young-Yeob;Kang, Bu-Byoung;Lee, Hi-Sung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2600-2608
    • /
    • 2011
  • The dynamic stability of railway vehicle has been one of the important issues in railway safety. The dynamic simulator has been used in the study about the dynamic stability of railway vehicle and wheel/rail interface. Especially, a small scale simulator has been widely used in the fundamental study in the laboratory instead of full scale roller rig which is not cost effective and inconvenient to achieve diverse design parameters. But the technique for the design of the small scale simulator for the fundamental study about the dynamic characteristics of the wheel-rail system and the bogie system has not been well developed in Korea. Therefore, the research about the development of the small scale simulator and the bogie has been conducted. As this paper, To predict the dynamic behavior of railway vehicle, we studied running stability test of 1/5 scaled bogie that similarity laws is applied using small scale derailment simulator. For the operation of the small scale derailment simulator, it is required to investigate the performance and characteristics of the system. This could be achieved by a comparative study between an analysis and an experiment. This paper presented the analytical model which could be used for verifying of the test results and understanding of the physical behavior of the dynamic system comprising the small scale bogie and the simulator.

  • PDF

Half-Scaled Substructure Test of a Transmission Tower Using Actuators (엑츄에이터를 이용한 송전철탑의 1/2 축소부분실험)

  • Moon, Byoung-Wook;Park, Ji-Hun;Lee, Sung-Kyung;Min, Kyung-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.178-188
    • /
    • 2007
  • In this paper, a half-scaled substructure test was performed to evaluate the buckling and structural safety of an existing transmission tower subjected to wind load. A loading scheme was devised to reproduce the dead and wind loads of a prototype transmission tower, which uses a triangular jig that is mounted on the reduced model to which the similarity law of a half length was applied. As a result of the preliminary numerical analysis carried out to evaluate the stability of a specimen for the design load, it was confirmed that the calculated axial forces of tower leg members were distributed to $80{\sim}90%$ of an admissible buckling load. When the substructured transmission tower was loaded by 270% of its maximum admissible buckling load, it was failed due to the local buckling that is occurred in joints with weak constraints for out-of-plane behavior of leg members. By inspection of load-displacement curves, displacements and strains of members, it is considered that this local buckling was due to additional eccentric force by unbalanced deformation because the time that is reached to yielding stress due to the bending moment is different at each point of a same section.

  • PDF

Model Tests Study on Flow-induced Vibrationof Tainter Gate in Estuary Sulices(Ⅱ)- Flow from the Gate Inside to the Gate Outside - (배수갑문 테인터 게이트(Tainter Gate)의 진동현상에 관한 모형실험(Ⅱ)- 문비 안에서 밖으로의 흐름 -)

  • Lee , Seong-Haeng;Woo , Sang-Ik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.2
    • /
    • pp.41-47
    • /
    • 2004
  • A model test is carried out to investigate flow-induced vibration of a Tainter gate in estuary sulices. The gate model scaled with the ratio of 1:25 is made of acryl panel dimensioned 0.66 m in width, 0.5 m in height in the concrete test flume. Firstly, natural frequencies of the model gate are measured and the results are compared with the numerical results in order to verify the model. In the flow from the gate inside to the gate outside, the amplitudes of the vibration are measured under the different gate opening and downstream water level conditions. Also revised gate models with 20 mm bottom width are tested under the different gate openings and water levels. The results are analyzed to study the characteristics of the Tainter gate vibration in the sea ward flow. These test results are assessed in comparison with the results in the lake ward flow, as a result, presents the dynamic characteristics of the Tainter gate and a basic data for the guide manuals of gate management.

A Study on the Measurement and the Analysis of Radar Cross Section of the Scaled Aircraft Model (축소형 항공기 모델의 레이다 단면적 분석 및 측정에 대한 연구)

  • Kim, Ki-Jung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.6
    • /
    • pp.1055-1060
    • /
    • 2020
  • This study is a study on the analysis and measurement of the radar cross-sectional area of a miniature aircraft. Radar cross-sectional area for miniature aircraft in advance were analyzed using an electromagnetic analysis tool, and an actual miniature aircraft was manufactured and measured in an anechoic chamber. When measuring, the old model was used as reference data for RCS(radar cross section) characteristics and applied to the test result data of the actual reduced model. The measurement method improved the accuracy of the measurement by applying time gating to remove the influence on the components scattered inside the anechoic chamber. The RCS test results of the reduced model showed relatively high RCS characteristics in the microwave band, as the previous analysis results. In the future, we plan to utilize the method of RCS analysis and measurement for the target of the radar in the VHF(Very High Frequency)/UHF(Ultra High Frequency) band with a relatively large wavelength.

Dynamic Characteristic of Lift Gate Supported by Plane Truss (평면트러스로 지지된 리프트 게이트의 진동특성)

  • Lee, Seong-Haeng;Yang, Dong-Woon;Hahm, Hyung-Gil;Kong, Bo-Sung;Shin, Dong-Wook
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.3
    • /
    • pp.133-139
    • /
    • 2012
  • Dynamic characteristic of lift gate supported by plane truss is studied by a model test scaled with the ratio of 1 : 31.25 in the four major rivers project. The vibrations of gate supported by the plane truss is assessed in comparison with those of gate supported by the space truss which was tested formerly. The gate model is made of acryl panel and calibrated by lead. A model test is conducted under the different gate opening and upstream water levels conditions in the concrete test flume dimensioned 1.6 m in width, 0.8 m in height and 24 m in length. In order to verify the model, natural frequencies of the model gate are measured, and compared with the numerical results. The vibrations of gate model supported by the plane truss in opening height of 1.0 cm~2.0 cm shows greater than one supported by the space truss. It is found that the gate model supported by the plane truss is less desirable than one supported by the space truss. thus, the latter type of gate model is requested to design.

A Study on an Operation Mode of a Rotary-type Small-scaled LIM for Railway Transit (철도차량용 회전형 축소모델 선형유도전동기의 운전모드 연구)

  • Park, Chan-Bae;Lee, Byung-Song;Lee, Hyung-Woo;Kwon, Sam-Young;Park, Hyun-June;Han, Kyung-Hee
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.310-315
    • /
    • 2008
  • Authors design a rotary-type small-scaled linear induction motor(LIM) and a performance test machine before manufacturing a real-scaled LIM for a railway transit. The designed LIM is a single-sided, short primary type and its primary has 4 poles. The rated power is 10(kW). In order to analyze characteristics of the LIM, authors use a mixed 2D-3D FEM analysis. 3-D FEM analysis is used for calculating a distribution of eddy-current on the semi-caped AL-sheet of the secondary reaction. Authors calculate a correction factor of conductivity and an equivalent conductivity on the secondary AL-sheet using a normalized eddy-current. The equivalent conductivity which is calculated in this way includes a transverse edge-effect of the LIM. Authors apply the equivalent conductivity on the secondary AL-sheet of 2D-FEM model and get performance characteristics of the LIM. Basic characteristics such as thrust and normal force, input current, efficiency and power factor of the LIM have been analyzed with the variation of frequency and speed. In order to apply an air-gap control system, the variation of the basic characteristics have been analyzed with the air-gap length variation of the LIM. Finally, authors introduce an operation mode using the air-gap control system and conduct a research on feasibility of the system.

  • PDF

Experimental Study on the Determination of Critical Velocity for the Case of Fire in Long Traffic Tunnels (장대 교통터널 화재시 임계속도 결정에 관한 실험적 연구)

  • Yoon Chanhoon;Yoon Sungwook;Yoo Yongho;Kim Jin
    • Tunnel and Underground Space
    • /
    • v.16 no.1 s.60
    • /
    • pp.85-94
    • /
    • 2006
  • In this study, scaled model tests were carried out to decide the optimal critical velocity, to prevent back layering in the case of fire in a long traffic tunnel. Realistic estimates were made for the time required for people to escape ken the tunnel and far the time required by the ventilation operator to increase the system speed to full capacity. The analysis, predicts that the emergency ventilation will start about 240 seconds after the tunnel fire. It was also found that prevention of back layering would occur within 4 minutes after fan operation. To find out optimal critical velocity, a 1/50 scaled model tunnel(diameter : 0.2 m and length : 20 m) based on the Froude similarity technique was constructed. Changing $\beta$ values in the Tetzner's equation, smoke propagation was observed. From the experiment, it was concluded that using a $\beta$ value of 0.5 to prevent back layering successfully allowed time for safe evacuation.