• 제목/요약/키워드: Scale model grounding system

검색결과 9건 처리시간 0.018초

축소모델 기법을 이용한 대규모 접지계의 특성분석 (Characteristic Analysis elf Large Grounding system by Using Reduced Scale Model Method)

  • 장석훈;이재복;명성호;조연규;김점식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권3호
    • /
    • pp.162-167
    • /
    • 2004
  • The scale model grounding systems to study the behavior of grounding system in uniform soils have been designed and fabricated. Constructional details and instrumentation have been discussed. To verify the accuracy of the results obtained from the experimental tests, they have been compared with computer calculation results. Also, in order to assess the effectiveness of bonding two grounding systems, grounding grid conductors which were downsized as a scale factor of 100:1 were analyzed by using the scale model method. A profile of GPR(Grounding Potential Rise) of each case was measured. The scale model grounding system presented in this paper can be valuable tool to analyze the ground potential profile and ground resistance of practical grounding system.

축소모델기법을 이용한 다중접지계의 특성분석 (Characteristic Analysis of Multi-grounding System by Using a Scale Model Technique)

  • 이재복;명성호;장석훈;조연규;김점식;길경석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1738-1740
    • /
    • 2003
  • This paper deals with the characteristic analysis of multi-grounding system. In order to assess the effectiveness of bonding two grounding systems, the scale model grounding simulation system and grid grounding conductors which were downsized as a scale factor of 100:1 were designed and fabricated. A profile of GPR(Grounding Potential Rise) of each case was measured. Also the measured results were compared with the analysis results.

  • PDF

구조체 접지전극의 유형에 따른 전위경도 특성 (Characteristics of Potential Gradient for the Type of Structure Grounding Electrode)

  • 길형준;최충석;김향곤;이복희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권8호
    • /
    • pp.371-377
    • /
    • 2005
  • This paper Presents the Potential gradient characteristics of structure grounding electrode when a test current flows through grounding electrode. In order to analyze the potential gradient of ground surface on structure grounding electrode, the reduced scale model has been used. The potential gradient has been measured and analyzed for types of structure using the hemispherical grounding simulation system in real time. The structures were designed through reducing real buildings and fabricated with four types on a scale of one-one hundred sixty. The supporter was made to put up with weight of structure and could move into vertical, horizontal, rotary direction. When a test current flowed through structure grounding electrodes, ground potential rise was the lowest value at electric cage type(type B). According to resistivity and absorption percentage In concrete attached to structure, the potential distribution of ground surface appeared differently.

메쉬접지극의 접지저항에 관한 실증연구 (An experimental research about the grounding resistance of the mesh electrode in the model of water tank)

  • 김주찬;최종규;이충식;고희석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.349-354
    • /
    • 2005
  • Recently, there are many equipment of electricity, electronics, and communication which need to grounding in the building. When the electric current flows into a certain grounding system in the same building, the potential rise of other grounding system is possible to be affected by its potential rise. This potential interference was affected by the surface potential, it is deeply related whit the electrode shape. In this paper, basic formula is deduced on the basis of both electrodes surface potential of grounding electrode in a source of the potential interference and groundidng electrode which receive the potential interference. Therefore the degree of potential interference as multiple groundidng electrode can be verified the simulated results by means of the simple model in advance. This is for investigating the grounding resistance of grounding electrodes, the experiment was performed with model-scale of the grounding system and the scaled model grounding system was to this experiment using a water tank of a stainless steel-hemisphere shape. since mesh electrodes have been widely in the general building, we're tried to analyze that this water tank model and it's simulation as well.

  • PDF

A Simulator for Potential Distribution Analysis

  • Kil, Gyung-Suk;Gil, Hyong-Jun;Park, Dae-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권2호
    • /
    • pp.225-229
    • /
    • 2012
  • This paper proposes a reduced-scale simulator that can replace numerical analytic methods for the estimation of potential distribution caused by ground faults in various grounding systems. The simulator consists of a hemispherical electrolytic tank, a three-dimensional potential probe, a grounding electrode, and a data acquisition module. The potential distribution is measured using a potentiometer with a position-tracing function when a test current flows to the grounding electrode. Using the simulator, we could clearly analyze the potential distribution for a reduced- scale model by one-eightieth of the buried depth and length of the grounding rod and grounding grid. Once both the shape of the grounding electrode and the fault current are known, the actual potential distribution can be estimated.

지능형빌딩의 대단위접지극의 전위간섭에 대한 실증연구 (An experimental research for Potential Interference of a Mesh electrode in Intelligent Building System)

  • 고희석;김주찬;최종규;김맹현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.414-416
    • /
    • 2005
  • This is for investigating the grounding resistance of grounding electrodes, the experiment was performed with model-scale of the grounding system and the scaled model grounding system was to this experiment using a water tank of a stainless steel-hemisphere shape. since mesh electrodes have been widely in the general building, we're tried to analyze that this water tank model and it's simulation as well.

  • PDF

수조모델을 이용한 메쉬접지극의 접지저항에 관한 연구 (Study for the Grounding Resistance of the Mesh Grounding Electrode by Water Tank Model)

  • 김주찬;김성삼;최종규;이충식;고희석
    • 조명전기설비학회논문지
    • /
    • 제20권3호
    • /
    • pp.28-35
    • /
    • 2006
  • 최근들어 빌딩내에 있는 많은 전기 전자 통신설비들은 기기 보호 및 안전을 위하여 반드시 접지를 필요로 하며, 고장 전류가 같은 빌딩내에 있는 어떤 접지 시스템으로 흐를 때, 이 전류에 의한 전위상승에 영향을 받아 다른 접지시스템의 전위 상승을 유도할 수 있다. 이러한 전위간섭은 접지극의 표면전위에 의해 영향을 받으며, 전각의 형상과 깊은 관련이 있다. 본 논문에서의 기본적 공식은 전위간섭을 받는 접지극과 전위간섭의 원천이 되는 두 접지극의 표면 전위에 기초하여 추론되었으며, 다중 접지극에 있어서의 전위간섭의 정도는 미리 간단한 모델을 이용하여 시뮬레이션을 실시하였다. 이는 대지위에 설치되는 건조물의 접지저항을 추정하기 위한 것이며, 실제의 현장에서 측정한 접지 저항값과 추정값과의 일치성을 입증하기 위하여 반구형 수조에서 모의 접지시스템의 축적 모델로 실험을 행한 결과, 확실한 메쉬접지극의 접지저항을 얻을 수 있었다. 따라서 수조 모델 실험을 통하여 메쉬접지각의 접지저항을 추정할 수 있음을 보여주고 있다.

구조체 접지의 전위상승에 대한 반구형 수조에 의한 측정값과 계산값의 비교 (Comparison of Theoretical Resu Its and Measured Data Using Hemispherical Water Tank Model for Potential Rise of Structure Grounding)

  • 길형준;최충석;김향곤;한운기;이복희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.111-114
    • /
    • 2005
  • This paper presents a comparison of experimental value by hemispherical grounding simulation system and calculated value by CDEGS program for ground potential rise of structure. When a test current flowed through structure grounding electrodes, ground potential rise was measured and analyzed for types of structure using the hemispherical grounding simulation system in real time, and was computed by means of CDEGS program. The model structures were designed and fabricated with two types on a scale of one-one hundred sixty. When the experimental data were compared with the theoretical values, the similar profile was shown. Therefore, the confidence of measurement was obtained. The distributions of ground surface potential are dependent on the resistivity and absorption percentage in concrete attached to structure.

  • PDF

봉상 접지전극 상호간의 전위간섭에 대한 평가 (Evaluations on the Potential Interferences between Ground Rods)

  • 이복희;이수봉;이태형;정현욱;길형준
    • 조명전기설비학회논문지
    • /
    • 제20권5호
    • /
    • pp.92-98
    • /
    • 2006
  • 본 논문은 봉상접지전극 주변에서 접지전극간 전위간섭에 대해 다루었다. 접지전극 상호간의 전위간섭을 저감하는 기법을 제안하기 위해서 실규모 접지전각에서 발생될 수 있는 대지전위와 전위간섭을 이론적 해석과 축소모델 실험을 이용하여 실험적으로 분석하였다. 반구형 수조모의접지 실험장치로 접지전극 상호간 이격거리에 따른 전위 상승과 전위간섭계수를 측정하고, CDEGS 소프트웨어를 이용하여 이들 현상을 해석하였다. 그 결과 전위상승과 전위간섭계수는 접지전극의 이격거리에 강하게 의존하였으며, 실측결과는 이론적 계산결과와 잘 일치는 결과를 얻었다.