• Title/Summary/Keyword: Scale height

Search Result 1,115, Processing Time 0.031 seconds

A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer (변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구)

  • Kim, Do-Hyun;Cho, Nam-Wook;Yoon, Choung-Ho;Park, Pil-Yong;Park, Keun-Sung
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.53-62
    • /
    • 2017
  • Electric power which is the energy source of economy and industries requires long distance transportation due to regional difference between its production and consumption, and it is supplied through the multi-loop transmission and distribution system. Prior to its actual use, electric power flows through several transformations by voltage transformers in substations depending on the characteristics of each usage, and a transformer has the structure consisting of the main body, winding wire, insulating oil and bushings. A transformer fire that breaks out in substations entails the primary damage that interrupts the power supply to houses and commercial facilities and causes various safety accidents as well as the secondary economic losses. It is considered that causes of such fire include the leak of insulating oil resulting from the destruction of bottom part of bushings, and the chain reaction of fire due to insulating oil that reaches its ignition point within 1 second. The smoke detector and automatic fire extinguishing system are established in order to minimize fire damage, but a difficulty in securing golden time for extinguishing fire due to delay in the operation of detector and release of gas from the extinguishing system has become a problem. Accordingly, this study was carried out according to needs of active mechanism to prevent the spread of fire and block the leak of insulating oil, in accordance with the importance of securing golden time in extinguishing a fire in its early stage. A bushings fireproof structure was developed by applying the high temperature shape retention materials, which are expanded by flame, and mechanical flame cutoff devices. The bushings fireproof structure was installed on the transformer model produced by applying the actual standards of bushings and flange, and the full scale fire test was carried out. It was confirmed that the bushings fireproof structure operated at accurate position and height within 3 seconds from the flame initiation. It is considered that it could block the spread of flame effectively in the event of actual transformer fire.

Improvement of Fluid Penetration Efficiency in Soil Using Plasma Blasting (플라즈마 발파를 이용한 토양 내 유체의 침투 효율 개선)

  • Baek, In-Joon;Jang, Hyun-Shic;Song, Jae-Yong;Lee, Geun-Chun;Jang, Bo-An
    • The Journal of Engineering Geology
    • /
    • v.31 no.3
    • /
    • pp.433-445
    • /
    • 2021
  • Plasma blasting by high voltage arc discharge were performed in laboratory-scale soil samples to investigate the fluid penetration efficiency. A plasma blasting device with a large-capacity capacitor and columnar soil samples with a diameter of 80 cm and a height of 60 cm were prepared. Columnar soil samples consist of seven A-samples mixed with sand and silt by ratio of 7:3 and three B-samples by ratio of 9:1. When fluid was injected into A-sample by pressure without plasma blasting, fluid penetrated into soil only near around the borehole, and penetration area ratio was less than 5%. Fluid was injected by plasma blasting with three different discharge energies of 1 kJ, 4 kJ and 9 kJ. When plasma blasting was performed once in the A-samples, penetration area ratios of the fluid were 16-25%. Penetration area ratios were 30-48% when blastings were executed five times consecutively. The largest penetration area by plasma blasting was 9.6 times larger than that by fluid injection by pressure. This indicates that the higher discharge energy of plasma blasting and the more numbers of blasting are, the larger are fluid penetration areas. When five consecutive plasma blasting were carried out in B-sample, fluid penetration area ratios were 33-59%. Penetration areas into B-samples were 1.1-1.4 times larger than those in A-samples when test conditions were the same, indicating that the higher permeability of soil is, the larger is fluid penetration area. The fluid penetration radius was calculated to figure out fluid penetration volume. When the fluid was injected by pressure, the penetration radius was 9 cm. Whereas, the penetration radius was 27-30 cm when blasting were performed 5 times with energy of 9 kJ. The radius increased up to 333% by plasma blasting. All these results indicate that cleaning agent penetrates further and remediation efficiency of contaminated soil will be improved if plasma blasting technology is applied to in situ cleaning of contaminated soil with low permeability.

A Study on the Structure of a Local Prison in the Joseon Dynasty Based on the comparison of excavation sites and antique maps (조선시대 지방 옥(獄) 구조에 관한 고찰 - 발굴 유적과 고지도 비교를 중심으로 -)

  • LEE, Eunseok
    • Korean Journal of Heritage: History & Science
    • /
    • v.54 no.4
    • /
    • pp.246-259
    • /
    • 2021
  • Research has been conducted in various fields on a local fortress (eupseong) in the Joseon Dynasty, but the archaeological research on the prison (獄), which is part of the internal government, has not been conducted properly. Since the prison was first discovered in Gyeongju in 1997, there has been a necessity for research on the deployment and structure of the prison. This includes the office where jailers worked and had night duty and also the enclosure that keeps the prisoners inside. But the research came to a standstill because there was no comparative data. However, compared to the more recent findings of the Yeonil Prison and the Gonju Prison, we can identify that the structure was built during the early to the late Joseon Dynasty. King Sejong designed the standard prison blueprint called Anokdo (犴獄圖) in 1426 to manage prisoners nationwide and revised it once in 1439 to give better treatment during the winter and summer seasons. The Yeonil Prison operated from 1421 to 1743 and shows the structure of the prisons during the early to mid-Joseon period. It was very similar to the Gyeongju Prison on a smaller scale, which was operated until the late Joseon Dynasty with two main structures, one east and one west, and a circular fence. This structure was maintained even in the Gongju Prison during the late Joseon Dynasty, and it remains visible in photographs. The prison of the Joseon Dynasty had a circular fence with an estimated height of 3 meters and two buildings that separated male and female prisoners. The prison was divided into men on the east and women on the west with tile-roofed house structures that were difficult to escape. In front of the circular fence, there was an office with a thatched roof for the jailers and access to the prison was only possible through a double prison gate. The layout of the building reflects the improvements of the king's prison design made during Joseon Dynasty improving the environment of prisoners who are on trial and separating men and women in order to embody humanism.

A New Early-Heading and High-Yielding Forage Rye Variety, 'Dagreen' (조숙 다수성 청예 조사료용 호밀 신품종 '다그린')

  • Cheong, Young-Keun;Heo, Hwa-Young;Park, Hyoung-Ho;Hwang, Jong-Jin;Han, Ouk-Kyu;Park, Tae-Il;Park, Ki-Hun;Choi, Jae-Seong;Seo, Jae-Hwan;Kim, Dae-Wook;Kim, Ki-Jong;Kim, Jung-Gon
    • Korean Journal of Breeding Science
    • /
    • v.42 no.6
    • /
    • pp.600-605
    • /
    • 2010
  • 'Dagreen' (Scale cereal L.), a new rye variety was developed from the open pollination among 10 rye lines at the National Institute of Crop Science in 1995 and mass selection were made at National Institute of Crop Science from 1996 to 1999. Recurrent selections were made at Dept. Rice and Winter Cereal Crop, NICS, RDA from 2000 to 2006. This new variety has erect plant type with medium size pale green leaves. The number of spike per $m^2$ was 713 and the plant height was 103cm. The heading date of 'Dagreen' was April 24 which was 7 days earlier than that of "Koolgrazer". It was adaptable for forage use at an early stage as a whole crop. Lodging resistance was higher than that of check variety 'Koolgrazer'. The chemical components and quality of forage showed 10.2 % crude protein, 36.6 % ADF, 62.4 % NDF and 59.9 % TDN. 'Dagreen' showed high resistance to powdery mildew and leaf rust than those of check variety in the field condition. The average dry matter (7,010kg $ha^{-1}$) of 'Dagreen' harvested at April 28 were 6 % higher than 'Koolgrazer'. This variety is recommended for all of the rye cultivation area in Korea.

First Observational Finding of Submesoscale Intrathermocline Eddy in the East Sea using Underwater Glider (수중글라이더를 활용한 동해 아중규모 중층성 소용돌이 발견)

  • PARK, JONGJIN
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.24 no.2
    • /
    • pp.332-350
    • /
    • 2019
  • Zonal hydrographic section measurements at $39.7^{\circ}N$ were conducted between $129.0^{\circ}E$ and $131.3^{\circ}E$ from August 7 to 25 in 2017 using an underwater glider. The glider traveled about 440 km for about 18 days along the 106 line of the regular shipboard measurements in the National Institute of Fishery Science (NIFS) and obtained twice a hydrographic section with high horizontal resolution. Even under the strong East Korea Warm Current with maximum speed of 0.8 m/s across the section, the glider successfully maintained the designated path within an RMS distance of 400 m. By comparing with the NIFS shipboard hydrographic section, it is confirmed that high spatial resolution measurements obtained from a glider were necessary to properly observe front and eddy variability in the East Sea where a typical spatial scale is smaller than the open oceans. From the glider section measurements, a new lens-shaped eddy was found in the thermocline. The lens-shaped anticyclonic eddy had 10~13 km in horizonal width and about 200 m in height like a typical submesoscale eddy resided within the thermocline, which was firstly named as Korea intrathermocline eddy (Keddy). The Keddy has the distinguishing characteristics of a typical intrathermocline eddy, such as a central core with anomalously weak stratification, a convex shaped lens bounded by the stratification anomaly, an interior maximum of velocity at 170 m, no surface appearance of the geopotential field, a small or comparable horizontal width relative to the first baroclinic Rossby radius of deformation, and the Rossby nubmer of 0.7.

Development of remote control automatic fire extinguishing system for fire suppression in double-deck tunnel (복층터널 화재대응을 위한 원격 자동소화 시스템 개발 연구)

  • Park, Jinouk;Yoo, Yongho;Kim, Yangkyun;Park, Byoungjik;Kim, Whiseong;Park, Sangheon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.167-175
    • /
    • 2019
  • To effectively deal with the fire in tunnel which is mostly the vehicle fire, it's more important to suppress the fire at early stage. In urban tunnel, however, accessibility to the scene of fire by the fire fighter is very limited due to severe traffic congestion which causes the difficulty with firefighting activity in timely manner and such a problem would be further worsened in underground road (double-deck tunnel) which has been increasingly extended and deepened. In preparation for the disaster in Korea, the range of life safety facilities for installation is defined based on category of the extension and fire protection referring to risk hazard index which is determined depending on tunnel length and conditions, and particularly to directly deal with the tunnel fire, fire extinguisher, indoor hydrant and sprinkler are designated as the mandatory facilities depending on category. But such fire extinguishing installations are found inappropriate functionally and technically and thus the measure to improve the system needs to be taken. Particularly in a double-deck tunnel which accommodates the traffic in both directions within a single tunnel of which section is divided by intermediate slab, the facility or the system which functions more rapidly and effectively is more than important. This study, thus, is intended to supplement the problems with existing tunnel life safety system (fire extinguishing) and develop the remote-controlled automatic fire extinguishing system which is optimized for a double-deck tunnel. Consequently, the system considering low floor height and extended length as well as indoor hydrant for a wide range of use have been developed together with the performance verification and the process for commercialization before applying to the tunnel is underway now.

An Analysis Study of Deliberation Results to Change the Present Condition around Gyeonggi-do Designated Cultural Properties - Focusing on the Proposed Legislation 3 or More Times a Deliberations of the Cultural Properties Committee - (경기도지정문화재 주변 현상변경허가 신청안 심의결과에 관한 분석 연구 - 문화재위원회심의 3회 이상 상정안을 중심으로 -)

  • Lim, Jin-Kang;Kim, Dong-Chan
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.29 no.3
    • /
    • pp.85-96
    • /
    • 2011
  • The purpose of this study, Around Gyeonggi-do cultural propertie Change the Present Condition not apply to analyze the results of processing Change the Present Condition of the trends and issues, and characteristics are derived and In determining the basic data processing of the Change the Present Condition presented are intended to be. 248 of 2009 regulated by Gyeonggi-do Cultural Assets committee agenda for consideration of the more than three times a copy of 15 were enrolled in the study. Review the results of the Change the Present Condition permit, permit held, to review classified information and analyzes the results of processing and complementary. Application for change processing standards and their comparison with the Change the Present Condition of cultural property through the deliberations and conclusions should analyze the results. As a result of research first, decision to allow processing of the application is characterized by a variety of facilities and the lower floors many times the result of the approval, the construction of cultural property conditioned space after the application complements the exterior of the building permit has been determined, applied to the current building near where the decision to allow the existence of is the main reason Second, decisions permit held, if requested neighborhood facilities lots of facilities and construction of large-scale is the most. Results from the first hearing until a final decision is not much change in results and cultural property surroundings due to the building of the reason for rejection was the most inhibited. Third, reconsideration of the decision if the city's development projects and other large development projects, and floors of the building height did not significantly affect the change. Above all, Decisions based on the results of the presence or absence was a big acts and the reason for reconsideration, and on-site investigation is the most. Fourth, It is based on the processing of Change the Present Condition that has been passed or rejected treatment and standards of treatment in two areas where the two sections across any side of the strict criteria were applied. Cultural Properties and applications with the distance increases, the rejection and the reconsideration decision is limited Such distance did not affect the decision to allow.

Construction Techniques of Earthen Fortifications in the Hanseong Period of Baekje Kingdom (백제 한성기 토성의 축조기술)

  • LEE, Hyeokhee
    • Korean Journal of Heritage: History & Science
    • /
    • v.55 no.2
    • /
    • pp.168-184
    • /
    • 2022
  • This paper examined the construction techniques of the earthen fortifications in the Hanseong Period of Baekje Kingdom, which has been researched most frequently among the Three Kingdoms. The construction processes of the Earthen Fortifications were reviewed and dividing into 'selection of location and construction of the base', 'construction of the wall', and 'finish, extension and repair'. The results show that various techniques were mobilized for building these earthen fortifications. Techniques which were adequate for the topography were utilized for reinforcing the base, and several other techniques were used for constructing the wall. In particular, techniques for wall construction may be clearly divided into those of the fill(盛土) and panchuk(版築) techniques. The fill method has been assumed since the 2000s to have been more efficient than the panchuk technique. This method never uses the structure of the panchuk technique and is characterized by a complex soil layer line, an alternate fill, use of 'earth mound(土堤)'/'clay clod(土塊)', and junctions of oval fill units. The fill method allows us to understand active technological sharing and application among the embankment structures in the period of the Three Kingdoms. The panchuk technique is used to construct a wall using a stamped earthen structure. This technique is divided into types B1 and B2 according to the height, scale, and extension method of the structure. Type B1 precedes B2, which was introduced in the late Hanseong Period. Staring with the Pungnap Earthen Fortification in Seoul, the panchuk technique seems to have spread throughout South Korea. The techniques of the fill and panchuk techniques coexisted at the time when they appeared, but panchuk earthen fortifications gradually dominated. Both techniques have completely different methods for the soil layers, and they have opposite orders of construction. Accordingly, it is assumed that both have different technical systems. The construction techniques of the earthen fortifications began from the Hanseong Period of Baekje Kingdom and were handed down and developed until the Woongjin-Sabi Periods. In the process, it seems that there existed active interactions with other nations. Recently, since studies of the earthen fortifications have been increasing mainly in the southern areas, it is expected that comparative analysis with neighboring countries will be done intensively.

A Study on the Spatial Control Effect of Panjang in Donggwoldo (동궐도(東闕圖) 판장(板墻)의 공간통제 효과에 관한 연구)

  • HA Yujeong;KIM Choongsik
    • Korean Journal of Heritage: History & Science
    • /
    • v.55 no.4
    • /
    • pp.196-209
    • /
    • 2022
  • This study compared and analyzed the spatial division function and role of partitions by comparing the entire space and the spatial changes before and after the installation of partitions in <Donggwoldo>, which was manufactured in the late Joseon Dynasty. As a research method, a set standard was prepared to decompose the space of <Donggwoldo> into a unit space, and the standard was set according to the role and height of the space by classifying it into a main space, sub space, and transition space. Two convex maps were prepared according to before and after the installation of the Panjang, and the values of connectivity, control, and integration, which are spatial syntax variables, were calculated and analyzed. The results of the study are as follows. First, the partition in <Donggwoldo(東闕圖)> did not affect the overall spatial arrangement and control or connection of Donggwol, but the movement and access of space is limited to specific areas. Second, the partition was a facility intensively distributed in Naejeon(內殿) and Donggung(東宮) to be used actively in the way of space utilization. It shows that the unit space increased rapidly due to the installation of the partition. Since the partition was installed in the spaces that were open and under high control in the case of Naejeon(內殿), it helped to secure private spaces as closed ones under low control. On the other hand, for Donggung(東宮), the spaces were compartmented and divided with the partition to guide the movement path through narrow gates of the partition and increase the depth of the space. This helped to create spaces that are free and can be hidden as it increased the number of spaces coming through. Third, In addition to the functions of "eye blocking, space division, and movement path control" revealed in prior research, the partition has created a "space that is easy to control" within a specific area. The installation of the partition reduced the scale through the separation of spaces, but it occurred the expansion of the movement path and space. Also, the partition functioned to strengthen hiding and closure or increase openness as well through space division. This study is significant in that it revealed the value of the spatial control function of panjang through the analysis of spatial control and depth by analyzing the function of the partition with a mathematical model in addition to the analysis and study of the function and role of panjang. In addition, it is valuable in that it has prepared a framework for analysis tools that can be applied to traditional residential complexes similar to palaces by applying space syntax to <Donggungdo> to create convex spaces according to unit space division and connection types of palace architecture and landscape elements.

Evaluation of Cultivation Characteristics according to NO3- Ratio of Nutrient Solution for Korean Melon in Hydroponic Culture (양액의 NO3- 비율이 수경재배 참외의 생육과 수량에 미치는 영향)

  • Do Yeon Won;Ji Hye Choi;Chang Hyeon Baek;Na Yun Park;Min Gu Kang;Young Jin Seo
    • Journal of Bio-Environment Control
    • /
    • v.32 no.3
    • /
    • pp.249-255
    • /
    • 2023
  • Korean melon (Cucumis melo L.) is grown mostly in Northeast Asia area, and as a fruit mainly produced in Korea, the yield per unit area continues to improve, but the cultivation method is limited to soil cultivation, so it is necessary to develop hydroponic cultivation technology for scale and labor-saving is needed. As the ratio of NO3- increased, the plant height, the leaf length, the leaf width, and the internode length became longer and larger. On the other hand, the SPAD value decreased. The lower the ratio of NO3-, the faster the female flower bloom, and there was no difference in fruit maturity between treatments. There was no difference in the shape of fruit according to the ratio of NO3-, and the hardness was higher as the ratio of NO3- was lower. The total yield from March to July was KM3 5,650 kg/10a and KM1 4,439 kg/10a, 27% higher in KM3 and, in particular, 36% higher in quantity from March to May, when Korean melon prices were high season. Therefore, it was judged that it would be appropriate to supply NO3- suitable for hydroponic cultivation of Korean melon, which was formalized in December and produced from spring, at the level of 6.5 to 10 me·L-1.