• Title/Summary/Keyword: Scale down test

Search Result 180, Processing Time 0.024 seconds

Heat transfer characteristics around a circular combustion chamber of kerosene fan heater (석유 팬 히터의 연소실 주변 열전달 특성)

  • Kim, Jang-Gwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.4
    • /
    • pp.551-561
    • /
    • 1998
  • This paper was studied to understand the characteristics of heat transfer coefficients and surface temperature distributions around a circular combustion chamber within the heat-intercept duct of kerosene fan heater. The experiment was carried out in the heat-intercept duct of kerosene fan heater attached to the blow-down-type subsonic wind tunnel with a test section of 240 mm * 240 mm * 1200 mm. The purpose of this paper was to obtain the basic data related with normal combustion for new design from conventional kerosene fan heater, and to investigate the effect of surface temperature, local and mean heat transfer coefficients versus flow-rate of convection axial fan according to the variations of heat release conditions from kerosene fan heater during normal combustion. Consequently it was found that (i) the revolution of convection axial fan during combustion had a smaller value than that of non-combustion because of the thermal resistance due to the high temperature in the heat-intercept duct, (ii) the pressure ratio P$_{2}$/P$_{1}$ had a comparatively constant value of 0.844 according to the revolution increase of turbo fan and the heating performance of kerosene fan heater had a range of 1,494 ~ 3,852 kcal/hr, (iii) the local heat transfer coefficient around a circular combustion chamber had a comparatively larger scale in the range of 315 deg. < .theta. < 45 deg. than that in the range of 90 deg. < .theta. < 270 deg. as a result of heat transfer difference between front and back of a circular combustion chamber, and (iv) the mean heat transfer coefficient around a circular combustion chamber increased linearly like a H$_{m}$=95.196Q+104.019 in condition of high heat release according to the increase of flow-rate of axial fan.n.

Patient Satisfaction with Advanced Practice Nurse in a Tertiary Hospital (일 상급종합병원의 전문간호사에 대한 환자만족도)

  • Choi, Eun Ju;Jang, In Sil;Hwang, Ji Hyeon;Kang, Young-Ah;Kim, Sung Reul;Nho, Ju-Hee;Kim, Jeong Hye
    • Journal of Korean Clinical Nursing Research
    • /
    • v.21 no.3
    • /
    • pp.335-346
    • /
    • 2015
  • Purpose: The purpose of this study was to identify patient satisfaction about nursing care provided by Advanced Practice Nurses (APN) using the La Monica-Oberst Patient Satisfaction Scale (LOPSS). Methods: The investigation was conducted including 263 patients who experienced care provided by 41 APNs at a tertiary hospital in Korea. Patient satisfaction with nursing care was measured using 41-item LOPSS. We analyzed the data using descriptive statistics, independent t-test and one-way ANOVA. Results: Overall patient satisfaction with APN care was high. The LOPSS scores for APNs were 52.26 for good impression, 61.75 for interpersonal support, 81.32 for dissatisfaction and 195.93 for total score. "APNs talk down to me" was a reverse coding item which demonstrated the highest score for patient satisfaction. Among patients' characteristics, age and type of main caregiver were independent factors related to patients's satisfaction. Among APN's characteristics, work experience was significantly related to patients' satisfaction. Conclusion: This study identified patient satisfaction regarding nursing care provided by APNs. High patient satisfaction in APN services demonstrated APNs' contribution to quality improvement in health care services. It is recommended that various outcome research about APN service needs to be performed.

Experimental investigation of force-distribution in high-strength bolts in extended end-plate connections

  • Abdalla, K.M.;Abu-Farsakh, G.A.R.;Barakat, S.A.
    • Steel and Composite Structures
    • /
    • v.7 no.2
    • /
    • pp.87-103
    • /
    • 2007
  • This paper presents some of the results from an experimental research project on the behavior of extended end-plate connections subjected to moment conducted at the Structural Laboratory of Jordan University of Science and Technology. Since the connection behavior affects the structural frame response, it must be included in the global analysis and design. In this study, the behavior of six full-scale stiffened and unstiffened cantilever connections of HEA- and IPE-sections has been investigated. Eight high strength bolts were used to connect the extended end-plate to the column flange in each case. Strain gauges were installed inside each of the top six bolts in order to obtain experimentally the actual tension force induced within each bolt. Then the connection behavior is characterized by the tension force in the bolt, extended end-plate behavior, moment-rotation relation, and beam and column strains. Some or all of these characteristics are used by many Standards; therefore, it is essential to predict the global behavior of column-beam connections by their geometrical and mechanical properties. The experimental test results are compared with two theoretical (equal distribution and linear distribution) approaches in order to assess the capabilities and accuracy of the theoretical models. A simple model of the joint is established and the essential parameters to predict its strength and deformational behavior are determined. The equal distribution method reasonably determined the tension forces in the upper two bolts while the linear distribution method underestimated them. The deformation behavior of the tested connections was characterized by separation of the column-flange from the extended end-plate almost down to the level of the upper two bolts of the lower group and below this level the two parts remained in full contact. The neutral axis of the deformed joint is reasonably assumed to pass very close to the line joining the upper two bolts of the lower group. Smooth monotonic moment-rotation relations for the all tested frames were observed.

Numerical simulation of VOC decomposition in an arc plasma reactor (수치해석 기법을 이용한 아크 플라즈마 반응기의 VOCs 분해성능 평가연구)

  • Park, Mi-jeong;Jo, Young-min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.1-7
    • /
    • 2016
  • A range of techniques have been being developed to remove the volatile organic compounds from paining processes. High temperature decomposition of harmful VOCs using arc plasma has recently been proposed, and this work analyzed the extreme hot process by computer-aided fluid dynamics prior to the reactor design. Numerical simulations utilized the conservation equations of mass and momentum. The simulation showed that the fluid flowed down along the inner surface of the centrifugal reactor by forming intensive spiral trajectories. Although the high temperature gas generated by plasma influences the bottom of the reactor, no heat transfer in radial direction appeared. The decomposition efficiency of a typical VOCs, toluene, was found to be a maximum of 67% across the reactor, which was similar to the value (approximately 70%) for the lab-scale test.

A Wind Tunnel Study on the Static Stability Characteristics of Light Sport Aircraft (스포츠급 경항공기의 정안정 특성 풍동시험 연구)

  • Kim, Jong-Bum;Jang, Young-Il;Kwon, Ky-Beom;Chung, Hyoung-Seog;Cho, Hwan-Kee;Kim, Sang-Ho;Lee, Jae-Woo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.8
    • /
    • pp.711-717
    • /
    • 2012
  • During the conceptual design phase of a light sport aircraft, the wind tunnel tests were conducted to investigate the static stability of newly-designed configuration. The 1/5 scale-down wind tunnel model consisted of fuselage, main wing, vertical tail and horizontal tail. The main wing and tails were able to be attached or detached from the fuselage. The aerodynamic forces and moments acting on the 6 different configurations compounding each component were measured by using the internal balance system and their static stability derivatives were derived. With these experimental data, the baseline lift and drag characteristics as well as the effects of each component to the longitudinal, directional and lateral static stability were quantitatively analyzed.

Structural Performance Tests of Down Scaled Composite Wind Turbine Blade using Embedded Fiber Bragg Grating Sensors

  • Kim, Sang-Woo;Kim, Eun-Ho;Rim, Mi-Sun;Shrestha, Pratik;Lee, In;Kwon, Il-Bum
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.12 no.4
    • /
    • pp.346-353
    • /
    • 2011
  • In this study, the structural performance tests, i.e., static tests and dynamic tests of the composite wind turbine blade, were carried out by using the embedded fiber Bragg grating (FBG) sensors. The composite wind turbine blade used in the test is the 1/23 scale of the 750 kW composite blade. In static tests, the deflections along the blade were evaluated. Evaluations were carried out with simple beam theory and quadratic fitting method by using the embedded FBG sensors to predict the structural behavior with respect to the load. The deflections were compared to those obtained from the laser displacement sensor and electric strain gauges. They showed good agreement. Modal tests were performed to investigate the dynamic characteristics using the embedded FBG sensors. The natural frequencies obtained from the FBG sensors corresponding to the nine mode shapes of the blade were compared to those from the laser Doppler vibrometer. They were found to be consistent with each other. Therefore, it is concluded that the embedded FBG sensors have a great capability for measuring the structural performances of the composite wind turbine blade when structural performance tests are carried out.

A Comparative Research on Korean and American Consumers Preference on Selected Korean and American Textiles for Womens Formal Wear (한국과 미국의 여성 정장용 소재에 대한 한.미 소비자 선호도 비교연구)

  • Ahn, Cheun-soon;Lee, Seung-Hee;Yang, Yoon;Lim, Sook-Ja;Lennon, Sharron J.;Parker, Sue M.
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.2
    • /
    • pp.217-227
    • /
    • 2001
  • The purpose of this research was to investigate the difference in fabric preference of formal wear attire between the Korean and American female consumers. For such purpose, fabrics which were used in the womens formal wear market of Korean(n=25) and U.S.A.(n=25) in the 1999 spring/summer season were collected from different fabric converters of the two countries. The respondents were comprised of 50 Korean and 50 U.S.A. female volunteers in the age group of 20s and 40s. A 5 point Likert Scale was used to evaluate the degree of the \"like\" preference of fabrics. T-test and Spearmans rho statistics were conducted for data analysis. The followings are the results. 1. Korean 20s and American 20s preferred Korean fabrics but Korean 40s and American 40s preferred U.S.A. fabrics. 2. Generally, the 20s preferred greyish or tone down color, whereas the 40s preferred both greyish and colorful fabrics. 3. Koreans preferred melange colored fabrics as well as solid color fabrics. 4. Americans liked knit fabrics as well as woven fabrics for formal wear and 20s liked compact density fabrics compared to the 40s age group.age group.

  • PDF

Vibration Control of Steel-Frame Structures by a Linear Motor Damper (선형 모터 댐퍼를 이용한 철골 구조물의 진동제어)

  • 문석준;정태영;임채욱;정정교;박진일;김두훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.49-58
    • /
    • 2003
  • The linear motor has not only no backlash and less friction, resulting in very high accuracy, but also mechanical simplicity, higher reliability, and longer lifetime. In this study, a large-capacity hybrid mass damper using linear motor principle has been developed to suppress vibration of large structures. It is designated linear motor damper in this paper. The LMD has been designed to be able to move the auxiliary damper mass of 155kg up to $\pm$250mm stroke. A series of performance tests for LMD control system with $H_{winfty}$ robust controller have been carried out on the full-scale steel frame structure. Through the performance tests, it is confirmed that vibration response levels are reduced down 10dB for the first and second modes of the test structure.

Study on mapping of dark matter clustering from real space to redshift space

  • Zheng, Yi;Song, Yong-Seon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.38.2-38.2
    • /
    • 2016
  • The mapping of dark matter clustering from real to redshift spaces introduces the anisotropic property to the measured density power spectrum in redshift space, known as the Redshift Space Distortion (hereafter RSD) effect. The mapping formula is intrinsically non-linear, which is complicated by the higher order polynomials due to the indefinite cross correlations between the density and velocity fields, and the Finger-of-God (hereafter FoG) effect due to the randomness of the peculiar velocity field. Furthermore, the rigorous test of this mapping formula is contaminated by the unknown non-linearity of the density and velocity fields, including their auto- and cross-correlations, for calculating which our theoretical calculation breaks down beyond some scales. Whilst the full higher order polynomials remains unknown, the other systematics can be controlled consistently within the same order truncation in the expansion of the mapping formula, as shown in this paper. The systematic due to the unknown non-linear density and velocity fields is removed by separately measuring all terms in the expansion using simulations. The uncertainty caused by the velocity randomness is controlled by splitting the FoG term into two pieces, 1) the non-local FoG term being independent of the separation vector between two different points, and 2) the local FoG term appearing as an indefinite polynomials which is expanded in the same order as all other perturbative polynomials. Using 100 realizations of simulations, we find that the best fitted non-local FoG function is Gaussian, with only one scale-independent free parameter, and that our new mapping formulation accurately reproduces the observed power spectrum in redshift space at the smallest scales by far, up to k ~ 0.3 h/Mpc, considering the resolution of future experiments.

  • PDF

Median Filtering Detection of Digital Images Using Pixel Gradients

  • RHEE, Kang Hyeon
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.4
    • /
    • pp.195-201
    • /
    • 2015
  • For median filtering (MF) detection in altered digital images, this paper presents a new feature vector that is formed from autoregressive (AR) coefficients via an AR model of the gradients between the neighboring row and column lines in an image. Subsequently, the defined 10-D feature vector is trained in a support vector machine (SVM) for MF detection among forged images. The MF classification is compared to the median filter residual (MFR) scheme that had the same 10-D feature vector. In the experiment, three kinds of test items are area under receiver operating characteristic (ROC) curve (AUC), classification ratio, and minimal average decision error. The performance is excellent for unaltered (ORI) or once-altered images, such as $3{\times}3$ average filtering (AVE3), QF=90 JPEG (JPG90), 90% down, and 110% up to scale (DN0.9 and Up1.1) images, versus $3{\times}3$ and $5{\times}5$ median filtering (MF3 and MF5, respectively) and MF3 and MF5 composite images (MF35). When the forged image was post-altered with AVE3, DN0.9, UP1.1 and JPG70 after MF3, MF5 and MF35, the performance of the proposed scheme is lower than the MFR scheme. In particular, the feature vector in this paper has a superior classification ratio compared to AVE3. However, in the measured performances with unaltered, once-altered and post-altered images versus MF3, MF5 and MF35, the resultant AUC by 'sensitivity' (TP: true positive rate) and '1-specificity' (FN: false negative rate) is achieved closer to 1. Thus, it is confirmed that the grade evaluation of the proposed scheme can be rated as 'Excellent (A)'.