• 제목/요약/키워드: Scale Tester

검색결과 73건 처리시간 0.025초

A Correlation Between Crack Growth and Abrasion for Selected Rubber Compounds

  • Lee, Hyunsang;Wang, Wonseok;Shin, Beomsu;Kang, Seong Lak;Gupta, Kailash Chandra;Nah, Changwoon
    • Elastomers and Composites
    • /
    • 제54권4호
    • /
    • pp.313-320
    • /
    • 2019
  • A typical wear pattern was reported to resemble the fatigue crack growth behavior considering its mechanism, especially for amorphous rubbers such as styrene-butadiene rubber (SBR). In this study, the wear and crack growth rates were correlated using two separate experiments for carbon black and silica-reinforced selected rubber compounds. The wear rate was determined using a blade-type abrasion tester, where the frictional energy input during wearing was measured. The crack propagation rate was determined under different tearing energy inputs using a home-made fatigue tester, with a pure-shear test specimen containing pre-cracks. The rates of abrasion and crack propagation were plotted on a log-log scale as a function of frictional and tearing energies, respectively. Reasonable agreement was observed, indicating that the major mechanism of the abrasion pattern involved repeated crack propagation.

$BaSO_4$$CaCO_3$ 자동차용 Brake Pad의 마찰 특성에 미치는 영향 연구 (The Study on the Effect on Friction Characteristics of Brake Pads With $BaSO_4$ and $CaCO_3$)

  • 정근중;김향래;김대환;송현우;최형기
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2004년도 학술대회지
    • /
    • pp.47-52
    • /
    • 2004
  • The purpose of this study is to investigate the friction characteristics of brake pads according to different ratios of $BaSO_4/CaCO_3$. Four brake pads with different ratios of $BaSO_4/CaCO_3$ were manufactured. The friction characteristics of brake pads were tested using 1/5 reduced scale tester. With increasing of the amount of $BaSO_4$ density and shear strength of brake pads were increased and hardness of brake pads were decreased. In effectiveness, the friction coefficient of brake pad was higher and the stability of friction coefficient was better as the ratio of $BaSO_4$ increased. In fade test, friction coefficient of B3 sample used only $CaCO_3$ was decreased rapidly. B1 sample showed a good noise performance without noise generation. The wear resistance of samples were decreased with increasing of the ratio of $CaCO_3$.

  • PDF

한국산업표준(KS)에 따른 로크웰 경도 시험기의 불확도 산정에 관한 연구 (A Study on the Evaluation of Uncertainty of Rockwell Hardness C Scale According to the Korean Industrial Standards(KS))

  • 방건웅;탁내형
    • 열처리공학회지
    • /
    • 제13권3호
    • /
    • pp.163-169
    • /
    • 2000
  • Recently, uncertainty of hardeness became a major concem for the people working on the laboratory evaluation and accreditation. It is required to indicate uncertainty of hardness tester on the report after calibration. In addition to this, uncertainty of certified hardness reference block is also required to indicate on the certification sheet. Method on the evaluation of uncertainty in hardness measurement is agreed only recently for Rockwell hardness C scale. In this paper, a preliminary calculation of uncertainty based on type B evaluation has been made for hardness testers which satisfies the requirements of Korean Standards. It was found that the tolerance limit of mean value specified in KS should be increased to be compatible with the calculated uncertainty.

  • PDF

숙련된 근력 사용자와 미숙련 근력 사용자간 단시간의 전신 근력활동이 정신적 작업에 미치는 영향 (The Effect of a Whole-body Activity in a Short Time Period on Mental Work between The Skilled and The Unskilled in Muscular Movement)

  • 김정만
    • 산업경영시스템학회지
    • /
    • 제25권6호
    • /
    • pp.42-47
    • /
    • 2002
  • This paper examines the effects on mental task of changes in the intensity of physical activity. A treadmill-equipped instrument and perception tester were used to attain several levels of physical activity. In this paper, in order to determine the individual levels of physical activity of subjects, Borg-RPE scale, heart rate(HR) and respiratory quotient(RQ) were used. Also, an arithmetic addition test in whole-body activity on treadmill-equipped instrument as an indicator of mental task were performed. In the above experiments, the scores obtained in arithmetic addition test administered before and after physical activity at each intensity level used. Restricted within the limits of this paper, the results of these tests showed that the performance of mental task was Increased after physical activity.

소형 초전도 부상자석의 특성 연구 (Study on the Characteristics of a Small Scale HTSC Levitation Magnet)

  • 조흥제;배덕권;이종민;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권1호
    • /
    • pp.76-81
    • /
    • 2007
  • This paper deals with the characteristics of a small scale $high-T_c$ superconducting(HTSC) levitation system. The levitation tester. which models after electrodynamic suspension(EDS) maglev, consists of one HTSC magnet, a reaction plate, and force measuring components. Instead of moving magnet, AC current was applied to the fixed HTSC magnet. The magnet also has persistent current switch(PCS). The inductance of the magnet was 18.5 mH and total joint resistance of the magnet was $5.74{\times}10^{-7}\Omega$. AC current was applied into the HTSC magnet with various frequencies and the levitation force was calculated and measured. According to the increase of the vehicle speed, the levitation force was saturated.

강우유출수의 신속한 처리를 위한 고속응집시스템의 성능 평가 -실험실 규모 장치를 중심으로- (Performance Evaluation of Lab-scale High Rate Coagulation System for CSOs Treatment)

  • 권은미;오석진;조성주;이승철;하성룡;임채환;박지훈;강선홍
    • 상하수도학회지
    • /
    • 제24권5호
    • /
    • pp.629-639
    • /
    • 2010
  • To evaluate the performance of high rate coagulation system(HRCS) for CSOs treatment, fundamental function of lab scale HRCS has been tested by using the Jar tester and lab scale HRCS. The optimum pH dose by Streaming Current value was found in the range of 5.3~6.0 in Fe(III), and in the range of 5.8~6.6 in Al(III) and the optimum chemical dose were 0.44mM of $Al_2(SO_4)_3$ and 0.93mM of $FeCl_3$. The removal efficiencies at optimum $Al_2(SO_4)_3$ dose were 75%($TCOD_{Cr}$), 97%(TP), 95%(SS) and 96%(turbidity), respectively. And the removal efficiency of particles with less than $5{\mu}m$ of diameter was 70% and that of particles with higher than $5{\mu}m$ of diameter was 90%. The optimum alum dose in lab scale HRCS was 150mg/L, and the treatment efficiency was the best with addition of 1.0mg/L polymer. The effect of Micro sand addition was not clear, because the depth of the sediment tank in lab scale HRCS was not long enough. But the HRT of this lab scale HRCS was able to be shorten less then 7 minutes by adding the micro sand. The surface loading rates with respect to using different chemicals were 0.43m/h with alum only, 5.78m/h with alum and polymer and 6.22m/h with alum, polymer and micro sand. As a result, HRCS using coagulant, polymer and micro sand developed in this study was evaluated to be very effective for CSOs treatment.

몬테카를로 시뮬레이션에 의한 미소 비커스 경도의 Weibull 통계 해석 (Weibull Statistical Analysis of Micro-Vickers Hardness using Monte-Carlo Simulation)

  • 김선진;공유식;이상열
    • 대한기계학회논문집A
    • /
    • 제33권4호
    • /
    • pp.346-352
    • /
    • 2009
  • In the present study, the Weibull statistical analysis using the Monte-Carlo simulation has been performed to investigate the micro-Vickers hardness measurement reliability considering the variability. Experimental indentation test were performed with a micro-Vickers hardness tester for as-received and quenching and tempering specimens in SCM440 steels. The distribution of micro-Vickers hardness is found to be 2-parameter Weibull distribution function. The mean values and coefficients of variation (COV) for both data set are compared with results based on Weibull statistical analysis. Finally, Monte-Carlo simulation was performed in order to evaluate the effect of sample size on the micro-Vickers hardness measurement reliability. For the parent distribution with shape parameter 30.0 and scale parameter 200.0 (COV=0.040), the number of sample data required to obtain the true Weibull parameters was founded by 20. For the parent distribution with shape parameter 10.0 and scale parameter 200.0 (COV=0.1240), the number of sample data required to obtain the true Weibull parameters was founded by 30.

Biomimetically Engineered Polymeric Surfaces for Micro-scale Tribology

  • Singh R. Arvind;Kim Hong-Joon;Kong Ho-Sung;Yoon Eui-Sung
    • KSTLE International Journal
    • /
    • 제7권1호
    • /
    • pp.14-17
    • /
    • 2006
  • In this paper, we report on the replication of surface topography of natural leaf of Lotus onto thin polymeric films using a capillarity-directed soft lithographic technique. PDMS molds were used to replicate the surface. The replication was carried out on poly(methyl methacrylate) (PMMA) film coated on silicon wafer. The patterns so obtained were investigated for their friction properties at micro-scale using a ball-on-flat type micro-tribo tester, under reciprocating motion. Soda lime balls (1 mm diameter) were used as counterface sliders. Friction tests were conducted at a constant applied normal load of $3000{\mu}N$ and speed of 1mm/s. All experiments were conducted at ambient temperature ($24{\pm}1^{\circ}C$) and relative humidity ($45{\pm}5%$). Results showed that the patterned samples exhibited superior tribological properties when compared to the silicon wafer and non patterned sample (PMMA thin film). The reduced real area of contact projected by the surfaces was the main reason for their enhanced friction property.

윤하중 시험과 유한요소해석을 통한 강상판 교면포장의 거동분석 연구 (An Evaluation of Orthotropic Steel Bridge Deck Pavement Behavior Using Wheel Load Testing and 3D Finite Element Analysis)

  • 김태우;최지영;이현종;백종은;엄병식
    • 한국도로학회논문집
    • /
    • 제15권1호
    • /
    • pp.103-110
    • /
    • 2013
  • PURPOSES: The objective of this study is to analyze and evaluate the behavior of orthotropic steel bridge deck pavement using three-dimensional finite element analysis and full-scale wheel load testing. METHODS: Since the layer thickness and material properties used in the bridge deck pavement are different from its condition, it is very difficult to measure and access the behavior of bridge deck pavement in the field. To solve this problem, the full-scale wheel load testing was conducted on the PSMA/Mastic bridge deck pavement and the deflection of bridge deck and horizontal tensile strain on top of pavement were measured under the loading condition. Three-dimensional finite element analysis was conducted to predict the behavior of bridge deck pavement and the predicted deflection and tensile strain values are compared with measured values from the wheel loading testing. RESULTS: Test results showed that the predicted deflections are 10% lower than measured ones and the error between predicted and measured horizontal tensile strain values is less than 2% in the critical location. CONCLUSIONS: The fact indicates that the proposed the analysis is found to be accurate for estimating the behavior of bridge deck pavements.

베일리 유아발달 척도의 한국 표준화를 위한 예비연구 (A Preliminary Study for the Standardization of the Bayley Scales of Infant Development for Korean Infants)

  • 정문자;이은해;박경자
    • 아동학회지
    • /
    • 제14권1호
    • /
    • pp.5-21
    • /
    • 1993
  • The purpose of this study was to examine the feasibility of standardizing the Bayley Scales of Infant Development(BSID) for Korean infants. To examine whether the Korean version of BSID is appropriate for Korean infants during the first 30 months of age, the Scale was administered to 285 Korean infants in 14 age groups. The infants were from intact and mostly middle-class families. According to item rewponse analyses of the Mental and the Motor Scales, the passing rate on each item increased by the infant's age. Regularity rather than irregularity was found on most items. Ordinarily of the Mental and the Motor Scale items in terns of age placement was similar to that of the U. S. sample. Several items, however, could be rearranged based on the data from the Korean sample. The total scores of the Mental and the Motor Scales reflected developmental trends in which score differences with a conjoining age group ranged from 3 to 15 for the Mental Scale, and 2 to 10 for the Motor Scale. Correlations between the two Scales in each age group were low to moderate (.03 to .67), with a median of .34. Reliabilities of the Korean version of the BSID in terms of the split-half reliability coefficients and the tester-observer agreements were satisfactory. Similarities as well as differences were found in developmental trends of infants between two cultures. A further study is needed not only to confirm results of this study but to set forth the standardization of the Bayley Scales to Korean infants.

  • PDF