• Title/Summary/Keyword: Saving energy rate

Search Result 325, Processing Time 0.026 seconds

Study on Energy Independence Plan and Economic Effects for Sewage Treatment Plant (하수처리시설의 에너지자립화 및 경제적 효과분석)

  • Park, Kihak;Lee, Hosik;Ha, Junsu;Kim, Keugtae;Lim, Chaeseung
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.2
    • /
    • pp.128-136
    • /
    • 2021
  • It is generally known that a wastewater treatment plant (WWTP) consumes immense energy even if it can produce energy. With an aim to increase the energy independence rate of WWTP from 3.5% in 2010 to 50% in 2030, the Korean government has invested enormous research funds. In this study, cost-effective operating alternatives were investigated by analyzing the energy efficiency and economic feasibility for biogas and power generation using new and renewable energy. Based on the US EPA Energy Conservation Measures and Korea ESCO projects, energy production and independence rate were also analyzed. The main energy consumption equipment in WWTP is the blower for aeration, discharge pump for effluent, and pump for influent. Considering the processes of WWTP, the specific energy consumption rate of the process using media and MBR was the lowest (0.549 kWh/㎥) and the highest (1.427 kWh/㎥), respectively. Energy-saving by enhancing anaerobic digester efficiency was turned out to be efficient when in conjunction with stable wastewater treatment. The result of economic analysis (B/C ratio) was 2.5 for digestive gas power generation, 0.86 for small hydropower, 0.49 for solar energy, and 0.15 for wind energy, respectively. Furthermore, it was observed that the energy independence rate could be enhanced by installing energy production facilities such as solar and small hydropower and reducing energy consumption via the replacement of high-efficiency operating.

A study of energy saving and long conservation in construction of rock store house (암반 저장창고 건설을 통한 에너지 절감과 장기보존에 대한 연구)

  • 최예환;채경희
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.210-216
    • /
    • 1998
  • The most important thing to consider in cold store design are to save cooling energy consumption and to keep goods freshly. Specially there are many efforts to save energy with cold store in Korea. A building energy simulation program should be used to optimally select a cooling system to match the criteria of cooling rate and storage rate in a given cool crop storage building and HVAC system. The low maintenance costs, high degree of safety and environmental impacts are also favouring the underground solution. There are obviously a lot of possibility for cost-effective storage of cooled or frozen goods or liquids in ground water rock.

  • PDF

A trust evaluation method for improving nodes utilization for wireless sensor networks

  • Haibo, Shen;Kechen, Zhuang;Hong, Zhang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.3
    • /
    • pp.1113-1135
    • /
    • 2018
  • Existing trust evaluation models for wireless sensor networks can accurately and objectively evaluate trust value of nodes, but the nodes' energy saving problem was ignored. Especially when there are a few malicious nodes in a network, the overall trust value calculation for all nodes would waste lots of energy. Beside that, the network failure caused by nodes death was also not considered. In this paper, we proposed a method for avoiding energy hole which applied trust evaluation models and a trust evaluation method based on information entropy, so as to achieve the purpose of improving nodes utilization. Simulation results show that the proposed method can effectively improve nodes utilization, and it has reasonable detection rate and lower false alert rate compared to other classical methods.

Analysis on the Ventilation Rate of Express Bus according to the Geometry of Vent (고속버스의 환기구 형태에 따른 환기량 분석)

  • Shin, In-Hwaw;Yoo, Ho-Chun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.174-178
    • /
    • 2011
  • This paper deals with the free cooling system of express bus using natural energy source in order to improve the room air quality and save cooling energy. In an express bus, there are may passengers in unit area, requiring the improvement of air quality and giving higher energy saving efficiency. Particularly, the express buses running fast make it easy to take in outdoor air at a flow rate controllable with a damper mechanism. This paper proposes the analysis on the air flow achieved by a damper controlled vertically and horizontally in order not to deteriorate the ride comfort of the passengers.

  • PDF

Operation Algorithm of Battery Energy Storage System (BESS) for Saving Electric Charges (전기요금 절감 측면에서 에너지저장시스템의 운전알고리즘)

  • 김응상
    • Journal of Energy Engineering
    • /
    • v.8 no.4
    • /
    • pp.519-524
    • /
    • 1999
  • this paper proposes the operation algorithm of 1MW class Battery Energy Storage System(BESS) installed at the extra-high voltage customer. The objective of the proposed algorithm is to reduce electric charges during the operation of the BESS interconnected to power system. This paper simulates the electric charges in 1998 considering Season and Time of Use Rate and Power Factor in the assumption that electricity demand in 1998 is the same amount of that in 1997 and shows the saving of about 40 million won in the total electric charges. The results comparing the real electric charges of June. July and August in 1997 with that in 1998 show that the implementation of the proposed algorithm could significantly reduce electric charges during the operation the BESS.

  • PDF

A Suggestion for the Worth Evaluation of Warm Air and the Allocation Methodology of Heating Cost (온기의 가치평가 및 난방비 배분방법론 제안)

  • Kim, Deok-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.10
    • /
    • pp.654-661
    • /
    • 2008
  • Our government will make a plan regulating the cooling limit temperature of the summer season to 26 degree and the heating limit temperature of the winter season to 20 degree for energy saving. Where, the key point of this politic pursuit can be the charge system on heating and cooling cost. Currently, the heating and cooling cost are charged as much as the volume or heat flow rate regardless of the high and low room temperature. However, we have suggested new cost estimating methodology as a worth method in the precedent study, and preformed the worth evaluation and cost allocation of electricity and heat on various cogenerations. In this study, we applied the suggested worth method to four kind of warm air, and preformed the worth evaluation and cost allocation of each warm air. As a result, the more energy a customer saved, the more heating unit cost decreased, and the more energy a customer consumed, the more heating unit cost increased. From this analysis, we hope that the suggested worth methodology can offer a theoretical basis to the politic pursuit of government, and induce the spontaneous energy saving of consumers.

Energy Saving Potentials of Radiant Floor Heating Systems Based on Control Strategies (바닥 복사 난방 시스템의 제어전략에 따른 에너지 사용량 분석)

  • Lee, Joon-Woo;Park, Cheol-Soo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.109-114
    • /
    • 2009
  • The dominant heating system used in Korean residential apartment buildings is a hydronic radiant floor heating system, known as the Ondol system. The most common control strategy applied to this traditional hydronic radiant system is a simple on-off control that intermittently supplies "hot water of a fixed temperature" at a "constant flow rate" to each room. However, the current problems with the aforementioned control are as follows: (1) since the simple on-off control is usually based on a one point measured temperature (a signal from a thermostat installed in a living room) in each dwelling unit, heating energy use for unoccupied rooms as well as a difference in temperatures between spaces (master bedroom, living room, bedroom1, bedroom2) can occur occasionally. (2) the most widely used residential water splitter has static valves, and is thus not able to change the flow rate to each room depending on the space heating load. In other words, the ratio of flow rates to rooms is fixed after construction, resulting in over- or under-heating and an improper use of energy. The aim of this paper is therefore to investigate the differences in the system's performance between control strategies in terms of the flow rate control and sensor location. It is shown that energy savings of control strategies are strongly influenced by occupant schedule.

  • PDF

Energy Performance of Air-side Economizer System for Data Center Considering Supply Temperature and Design Airflow Rate of CRAH(Computer Room Air Handler) (외기냉방시스템이 적용된 데이터센터 CRAH의 급기온도와 설계 풍량에 따른 에너지성능 분석)

  • Kim, Ji-Hye;Aum, Tae-Yun;Jeong, Cha-Su
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.11
    • /
    • pp.181-188
    • /
    • 2019
  • The purpose of this study is to evaluate the cooling energy saving effects of CRAH supply air temperature(SAT) and design flow rate changes when applying air-side economizer in the data center. MLC(Mechanical Load Component), which is cooling performance indicator of data center, was used to assess the effectiveness of cooling energy savings. It was computed with energy simulation (DesignBuilder) to evaluate the cooling energy performance of 8 different alternatives in a data center. The MLC was 0.31~0.32 regardless of CRAH supply temperature without air-side economizer, and 0.15 to 0.19 value with air-side economizer. That is, cooling energy can be reduced by approximately 40~55% when applying economizer. As the CRAH SAT and design flow rate changed, the MLC values were 0.16 to 0.18 and 0.15 to 0.19, respectively.

A Study on Capacity Design of Energy Storage System for Urban Transit System (도시철도시스템용 에너지저장시스템 용량설계에 관한 연구)

  • Lee, Han-Min;Kim, Gil-Dong;Lee, Chang-Mu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.697-700
    • /
    • 2007
  • Six thousands of vehicles are operated on Korean urban transit system. 95% of them have regeneration system. Especially, the VVVF-Inverter vehicle has a merit of the highest regeneration rate. Therefore, the energy storage system is needed to be developed to use regeneration energy when the vehicle is braking. Therefore, Measuring regeneration energy in the substation need to know how much regeneration energy occurs, how much capacity of energy storage system is needed. After measuring regeneration energy, we design the capacity of energy storage system.

  • PDF

MAC Protocols for Energy Harvesting Wireless Sensor Networks: Survey

  • Kosunalp, Selahattin
    • ETRI Journal
    • /
    • v.37 no.4
    • /
    • pp.804-812
    • /
    • 2015
  • Energy harvesting (EH) technology in the field of wireless sensor networks (WSNs) is gaining increasing popularity through removing the burden of having to replace/recharge depleted energy sources by energy harvester devices. EH provides an alternative source of energy from the surrounding environment; therefore, by exploiting the EH process, WSNs can achieve a perpetual lifetime. In view of this, emphasis is being placed on the design of new medium access control (MAC) protocols that aim to maximize the lifetime of WSNs by using the maximum possible amount of harvested energy instead of saving any residual energy, given that the rate of energy harvested is greater than that which is consumed. Various MAC protocols with the objective of exploiting ambient energy have been proposed for energy-harvesting WSNs (EH-WSNs). In this paper, first, the fundamental properties of EH-WSN architecture are outlined. Then, several MAC protocols proposed for EH-WSNs are presented, describing their operating principles and underlying features. To give an insight into future research directions, open research issues (key ideas) with respect to design trade-offs are discussed at the end of this paper.