• Title/Summary/Keyword: Saving energy rate

Search Result 325, Processing Time 0.026 seconds

A study on the irrigation water pumping system of multipurpose dams by the large water ejector (대형 수이젝터를 이용한 다목적댐 관개용수 펌핑시스템에 관한 연구)

  • 윤석훈;오철;손근홍;김철환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.1
    • /
    • pp.73-80
    • /
    • 1994
  • The water ejector is a low pressure high flow rate volumetric pump. It utilize the energy of a low mass flow, high velocity stream to induce a large mass flow, low velocity stream. In addition, it has a very good resistances to cavitation compared to the other type of pumps, and the maintenance cost is practically nil. There has been enormous energy loss to supply the upper part water of dam which has large potential energy as mere irrigation water in domestic multipurpose dam. The new type of energy saving system which developed through the present study can economizes over 950,000 kWh per year by mixing the upper part water of dam with the waste water by the large water ejector. This paper estimates the economical efficiency of the new type of irrigation water pumping system, and further more, represents the change of performance characteristics of large water ejector, which was adapted to this system, according to the fluctuation of upper water level that seasonally changes.

  • PDF

Feasibility Study on Installation of Individual Room Control Ventilation in Apartment House (공동주택의 실별 제어환기 도입 타당성 분석)

  • Kim, Jung-Yup;Shin, Hyun-Joon;Kwon, Yong-Il;Yun, Young-Woo;Cho, Chun-Sik
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.502-507
    • /
    • 2009
  • Trend of mechanical ventilation system applied to apartment house is introduced and feasibility study on installation of the individual room control ventilation as energy-saving method is carried out through field experiment. While initial cost of installation for the individual room control ventilation increases, the running cost is lower than the individual household control ventilation due to automatic flow rate control and reduction of fan power, and the management cost also decreases due to extension of use life of components. As the results of field experiment on $115m^2$-type apartment house, the individual room control ventilation could save the amount of 1,459.5Wh/day when compared with the individual room control ventilation

  • PDF

Thermal Insulation Property due to Internal Air-layer Content of Warm Multi Layer Materials by using Numerical Analysis (수치해석을 이용한 다겹보온자재의 내부공기층 함유에 따른 보온 특성)

  • Chung, Sung-Won
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.4
    • /
    • pp.97-103
    • /
    • 2012
  • This study investigates thermal insulation properties of multi layer materials depending on thickness of air layers. Numerical analysis on the heat flow of different insulating materials was conducted to identify whether their temperature distributions demonstrate the reduced rate of heat transfer conclusively or not. Analytical model is divided into two categories. One is to distinguish temperature distribution of the air-layer materials from the non-air layer ones. The other is to compare the efficacy between eight-layered insulating materials with no air-layer contained and three-layered insulating materials which include an air-layer definitely. In the latter case, the identical thickness is assigned to each material. The effect of thermal insulation by including an air-layer is verified in the first analytical model. The result of the second model shows that the insulation of the eight-layered materials is coterminous at the three-layered ones with an air-layer and the thermal insulation of the two materials is imperceptible. The benefits of cost and energy saving are anticipated if air-layers are efficiently incorporated in multi layer insulating materials in a greenhouse.

A Study on the Psychological Responses by the change of Illuminance and Color temperature in LED (LED 광원의 색온도와 조도 변화에 따른 심리반응 연구)

  • Yi, Yon-Soo;Ha, Mi-Kyoung
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.6
    • /
    • pp.129-136
    • /
    • 2012
  • As the importance of eco-friendly and energy saving issues are emphasized in lighting as consciousness about energy saving is elated worldwide, demand for natural resources such as gas increases, supply of LED lighting is spread. Owing to white LED's development and price fall. It is expected to LED High Luminance Emitting Diode. LED's brightness and long life-time that surpass fluorescent light in the latest as well as is used by back light source of thin film LCD, low electric power attrition rate by advantage do and widen the market at the world lighting lamp market that is potential market. Accordingly, study about suitability of LED lighting is activated but space that apply actual LED lighting fixtures yet is less and advanced researches about LED fixtures' applied apaces are slight compared to existing light source up to now because is not many on this. The result of the experiment shows similar tendency with the existing light sources'. Through a psychological reaction experiment in the LED lighting experiencing space that can control of color temperature and lighting level, this study is wished to use to the data for lighting design of space that LED lighting fixtures are applied hereafter.

  • PDF

Performence Characteristics and Analysis Effect of Maximum Power Saving Device in Metal Parts Heat Treatment Company (금속 부품 열처리업체의 최대전력절감장치 동작 특성 및 효과 분석)

  • Chang, Hong-Soon;Han, Young-Sub;Hwang, Ik-Hwan;Seo, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.40-44
    • /
    • 2014
  • In this paper, maximum power is the lowering device using the facility's energy use and peak load electricity through analyzing attitude should like to make it reduce its power base rate. Simulator to manage the demand for power, a maximum electric power base power from electronic watt-hour meters by a device's signal, predictive power, the current power by computing the goal of power for less than Maximum peak power and peak shift, so that you can manage, and peak York, which role you want a cut Metal heat treatment result which analyzes the data, demand for electricity company over the years of analyzing the characteristics of each load, and effects and Reducing power consumption device every month identified seven Sequence control to the load system and successful power control is about showing that the defined goals.

Development of Automatic Rewetting System for Rough Rice Stored in Round Steel Bin with Stirring Device -Adsorption characteristics of rough rice- (원형철제빈용 벼 자동흡습장치 개발에 관한 연구(I) -벼의 흡습특성-)

  • Kim, J. Y.;Keum, D. H.;Kim, H.;Park, S. H.
    • Journal of Biosystems Engineering
    • /
    • v.26 no.5
    • /
    • pp.469-474
    • /
    • 2001
  • Milling the rice with low moisture requires more energy, produces more cracked rice, and results in reducing taste of cooked rice. Accordingly, it is necessary to add moisture to the rice with low moisture to obtain optimum moisture level for milling and taste of rice. This study was performed to evaluate the influence of initial moisture content and absorption rate on rice crack, milling energy and whiteness of milled rice and to obtain the information for design of rewetting system mounted on stirring device in grain bin. The tests were conducted for the four levels of initial moisture content in the range of 11.4 to 14.5%(w.b.) and six levels of absorption rate in the range of 0.04 to 1.0%, w.b./hr. In the case of lower moisture content below 12%(w.b.), crack ratios of brown rice were remarkably high regardless of initial moisture contents. Therefore, it was found that rough rice below 12%(w.b.) in initial moisture content could not rewetted by spraying water without crack generation of low level. Absorption rate must be below 0.3%, w.b./hr to maintain crack ratio increase of less than 1% regardless of initial moisture contents. In the case of allowable crack ratio increase of 2% and 5%, it was found that the maximum absorprion rate was respectively 0.6%, w.b./hr and 1.0%, w.b./hr in the initial moisture content of above 13.5%(w.b.). Rewetting the rough rice in moisture content of 11.4 to 14.5%(w.b.) to 14.3 to 16.9%(w.b.) decreased milling energy consumption by 15.9 to 22.3%. The effect of energy saving was higher in the samples of higher initial moisture content. Whiteness of milled rice was decreased by 0.5 to 1.5.

  • PDF

Experimental Study on Heat and Mass transfer Coefficient Comparison Between Counterflow Types and Parallel in Packed Tower of Dehumidification System

  • Sukmaji, I.C.;Choi, K.H.;Yohana, Eflita;Hengki R, R.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.162-169
    • /
    • 2009
  • In summer electrical energy is consumed in very high rate. It is used to operate conventional air conditioning system. Hot and humid air can germinate mould spores, encourage ill health, and create physiological stress (discomfort). Dehumidifier solar cooling effect is the one alternative solution saving electrical energy. We use surplus heat energy in the summer, to get cooling effect and then to get human reach to comfort condition. These devices have two system, dehumidifier and regeneration system. This paper will be focus in dehumidifier system. Dehumidifier system use for absorbing moisture in the air and decreasing air temperature. When the liquid desiccant as strong solution contact with the vapor air in the packed tower, it works. The heat and mass transfer performances of flow pattern in the packed tower of dehumidifier are analyzed and compared in detail. In this experiment was introduced, the flow patterns are parallel flow and counter flow. The performance of these flow patterns will calculate from air side. Which is the best flow pattern that gave huge mass transfer rate? The proposed dehumidifier flow pattern will be helpful in the design and optimization of the dehumidifier solar cooling system.

  • PDF

Study Characteristics in Packed Tower of Liquid Desiccant Solar Cooling System Using Counter Flow Configuration

  • Rahmanto, R. Hengki;Choi, K.H.;Agung, B.;Sukmaji, I.C.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.168-174
    • /
    • 2009
  • High water vapour content in air can cause a number of problems as for human or surrounding materials. For human a high water vapour can create physiological stress, discomfort, and also can encourage ill health. While, the cause for the environment is can accelerate the corrosion of metals, accelerate the growth of spores and mould, can reduce the electrical resistance of insulators and etc. Desiccant systems have been proposed as energy saving alternatives to vapor compression air conditioning for handling especially the latent load and also sensible load. Use of liquid desiccants offers several design and performance advantages over solid desiccants, especially when solar energy is used for regeneration. The liquid desiccants contact the gas inside the packed tower of liquid desiccant solar cooling system and the heat transfer and mass transfer will occur. This thesis is trying to study the characteristics inside the packed tower of dehumidifier systems. This characteristics consist of mass transfer rate, heat transfers rate, human comfort and energy that consume by the system. Those characteristics were affected by air flow rates, air temperature and humidity, and desiccant temperature and all that variation will influence the performance of the systems. The results of this thesis later on can be used to determine the best performance of the systems.

  • PDF

ECONOMIC ANALYSIS BY GLASS TYPES IN BALCONY CONVERSION OF MULTI-FAMILY HOUSING PROJECTS

  • H.G. Kim;D.I. Kim;D.W. Ko;T.H. Hong;C.T. Hyun;K.J. Koo
    • International conference on construction engineering and project management
    • /
    • 2007.03a
    • /
    • pp.625-634
    • /
    • 2007
  • Energy-saving is one of important issues in multi-family housing projects in South Korea. According to the study by Yu et al. (2002), the balcony conversion causes energy loss approximately one and a half times. Therefore, it is important to select the economical glass type in the balcony window. In order to identify the most economical glass type of balcony conversion in multi-family housing projects, the most typical type of the multifamily housing projects in the metropolitan area was selected as a candidate project. The selected candidate project has been simulated using ENERGY-10 program to estimate the heat load by the different five types of glasses as well as their life cycle cost analysis (LCCA) using present worth method. Finally, sensitivity analysis has been conducted to determine the most economical glass types under a different discount rate (interest rate) and service life of building.

  • PDF

Curing Properties of UV-ccurable Acrylate/Alkyd Resin Blends II (UV-curable Acrylate/Alkyd Resin 혼합계의 경화특성 II)

  • 남수용;이경옥;대평태문;구철회
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.18 no.1
    • /
    • pp.157-166
    • /
    • 2000
  • UV-curable resins have adventages of quick set, space saving, clean environment, and efficient use of energy. The polymerization induced phase separation has been studied to solve the problem in UV-curing of thick films and develop the new functional materials. On the exposure to UV irradiation, the dynamic elasticity properties were mesured for mixtures of alkyd resin and UV-cruable monomers which have different molecular structures and molecular weights. The curing rate increases with increasing temperature and UV intensity. In addition, The gel point is strongly influenced by temperature and UV intensity

  • PDF