• Title/Summary/Keyword: Saving Energy

Search Result 2,731, Processing Time 0.026 seconds

Structural Conditions of Greenspace in a Rural Region and Strategies for its Functional Improvement - In the Case of Yanggu, Gangwon Province - (전원지역의 녹지구조 현황과 기능개선 방안 - 강원도 양구를 대상으로 -)

  • Jo, Hyun-Kil;Ahn, Tae-Won
    • Korean Journal of Environment and Ecology
    • /
    • v.20 no.4
    • /
    • pp.493-502
    • /
    • 2006
  • This study analyzed greenspace structure focused on greenspace areas and vegetation structure for Yanggu, investigated resident attitudes to the greenspace, and explored strategies to improve greenspace functions in a rural region. Woody plant cover was approximately 29% for parks and only 3% for commercial gardens. The amount of planting for Yanggu was poor, as compared with the results of similar studies for urban areas. Trees, of which dbh was below 20cm, accounted for 91% of all trees and the tree-age structure was largely characterized by a young, growing tree population. Based on the analysis of mean importance values (MIV) of woody plant species, only a few were different in dominant species from urban areas. Four species among 10 species with highest MIV in Yanggu were very common species also ranked among 10 in cities. The most dominant species planted in residential and commercial gardens were practical plants such as fruit or edibles. Greenspace covered about 69% of parks, 39% of residential gardens, 37% of institutional gardens, 24% of streets, and 15% of commercial gardens, respectively. Tree planting potential revealed that present woody plant cover can be increased additionally by 6 times in the streets and by 2 times in the residential and commercial gardens. Based on the results of greenspace structure, planting patterns, and questionary investigation, some strategies were suggested to enlarge greenspace including its environmental functions. They included identifying each street section through setting up themes and planting appropriate species, creating multilayered vegetation structures, and promoting planting in bare grounds of gardens and around a buildings for saving energy.

Energy Saving Effects of Underground Rock Storage System for Heating of Greenhouse (자갈축열 태양열 온실의 난방에너지 절감효과)

  • 이석건;이종원;이현우;김길동
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2001.04b
    • /
    • pp.29-30
    • /
    • 2001
  • 자연에너지원중 태양에너지를 이용한 자갈축열 태양열 온실의 난방에너지 절감효과를 분석하기 위하여 야간에 내부설정온도를 18℃로 했을 때의 자갈축열 태양열 온실과 동일한 제원의 대조온실의 난방연료소비량을 비교하였다. 자갈축열 태양열 온실의 경우 난방초기에는 연료가 대조온실에 비해 약 10%정도 더 소모되었으나 2일이 경과한 후에는 점차 난방연료소비량이 감소하였다(Fig. 2) 이러한 결과는 자갈축열 태양열 온실의 경우 주간에 온실에 투여되는 일사에 의해 축열이 이루어 질뿐만 아니라 야간에 난방을 할 경우에도 축열층의 온도가 설정온도에 도달할 때까지 축열이 이루지기 때문인 것으로 분석되었다 (Fig. 1). 3월 10일부터 3월 15일까지 6일간의 난방연료소비량이 대조온실은 167℃였으나, 자갈축열 태양열 온실은 109℃로써 대조온실에 비해 약 35%정도 난방연료 절감효과가 있는 것으로 분석되었다(Fig. 2). 6일간의 난방 후 자갈축열 태양열 온실에 난방을 중단한 결과 온실외부의 최저기온이 -2.4℃일 때 자갈축열 태양열 온실의 내부최저온도는 14℃를 유지하였으며, 이후 계속 난방을 수행하지 않은 상태에서도 주간에 축열효과로 인하여 최저외기온이 3℃전후일 때 자갈축열 태양열 온실의 내부온도는 15℃를 유지하였으나 대조온실은 5℃ 전후였다. 그리고, 일기온차가 심한 3월말에는 야간설정온도가 18℃인 경우에 자갈축열 태양열 온실의 난방연료소비량이 대조온실에 비해 월등히 적음을 알 수 있었다(Fig. 1, 2). 3월에 자갈축열 태양열 온실의 난방연료소비량은 대조온실에 비해 약 50%이상의 절감효과가 있는 것으로 나타났다./TEX>3.1cm, 2cm$\times$4.2cm 순으로 나타났다. 5. 저고리의 옆길이 곡선에 대한 평가는 진종의 중심인 겨드랑이가 5cm인 것이 가장 우수한 것으로 나타났으며, 그 다음으로 4cm, 6cm, 3cm 순으로 나타났다. 6. 이에 위의 항목들을 종합하여 제작한 연구저고리는 등길이가 28cm, 어깨선 위치는 1.75cm, 깃크기는 5cm$\times$21.5cm, 소매통 크기는 3cm$\times$4.3cm, 옆길이 곡선은 5cm로써 그 형태에 따른 신체적합성에 대한 외관 관능검사 결과로 3.83의 평균값으로 나타났고, 심미성에 대한 외관 관능검사를 항목별 평균치 값으로 종합하면 4.00의 값으로 나타났다. 또한 각 부위별 동작적합성 관능검사는 7가지 동작을 부위별 항목 평균치 결과 3.95의 유수한 저고리로 평가되었다. 본 연구 실험 결과 앞으로도 전통 저고리를 피복함에 있어 외관과 동작적합성이 좋은 저고리를 만들기 위해 지속적 연구가 요청된다. turned back than the Korean women's. Based on the above findings, a torso prototype was developed for the Chinese women by setting the body measurements in reference with their average body measurements plus minimum reserve. The reference lines were set for front/back central line, front/

  • PDF

Effects of Lettuce Cultivation Using Optical Fiber in Closed Plant Factory (폐쇄형 식물공장내 태양광 파이버를 이용한 상추 재배효과)

  • Lee, Sanggyu;Lee, Jaesu;Won, Jinho
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.105-109
    • /
    • 2020
  • This study was conducted to the improvement of solar light-based artificial light supply system and effect of lettuce cultivation. The artificial light supply system was consisted of units such as light source, power, system measurement and controller. The light source supply was composed of a solar transmitter and an LED lamp. The power supply consisted of an leakage breaker, SMPS, LED controller and relay. The solar transmitter was made of a quartz optical fiber with optimal light transmission. Artificial light used white lamp among LEDs. System measurement and control consisted of touch screen, Zigbee communication module and light quantity sensor. The results of test confirmed that the LED light is automatically activated when the intensity measured by the light intensity sensor is 200 μmolm-2s-1 or less. Moreover, the leaf length, root length, chlorophyll content and root fresh weight of optical fiber treatment was hight than LED lamp treatment. Therefore, it can be inferred that the energy-saving solar light collector device can be effective in the indoor lettuce production. However, the use of LED lamp is also recommended to assure the availability of sufficient sunlight in cloudy and rainy days.

Trend in Research and Development Related to Motors and Permanent Magnets for Solving Rare-earth Resources Problem (희토류 자원문제 해결을 위한 모터 및 영구자석 연구개발 동향)

  • Lee, J.G.;Yu, J.H.;Kim, H.J.;Jang, T.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.2
    • /
    • pp.58-65
    • /
    • 2012
  • Since Nd-Fe-B magnet was first synthesized in 1983, many new applications have emerged in the past two decades. With regard to motor market, it will expand because of strong energy saving requirements from the automobile and electric application markets. Especially, permanent magnet motors for hybrid and electric vehicles are drawing great attention and the usage of Nd-Fe-B magnets will increase all the more hereafter. There is, however, a serious problem as motors in such eco-friendly cars are said to operate in high temperatures of about $200^{\circ}C$. Nd-Fe-B magnet has a drawback of dramatically decreasing coercive force with the rise of temperature. In order to improve this aspect. the best way is to add dysprosium (Dy) into the magnet. So, Dy has become an essential element for Nd-Fe-B high-performance magnet as it helps to maintain coercive force even at high temperatures. On the other hand, the rare earth resources in the earth crust are eccentrically-located and its majority is produced in China. There is a need to reduce its usage as, especially compared to light rare earth elements as neodymium (Nd) and samarium (Sm), heavy rare earth elements including Dy are unevenly distributed to a dramatic degree, their output low, and their prices are about 10 times that of Nd. The present article includes a summary of the trend in research and development of motors and permanent magnets to solve rare-earth resources problem.

Development and Safety Evaluation of Earth Leakage Alarm Breaker Equipped with Fire Current (IGR) Alarming Function (화재전류(IGR) 경보 기능이 내장된 누전경보차단기의 개발 및 안전성 평가에 관한 연구)

  • Ko, Wan-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.43-48
    • /
    • 2020
  • The purpose of this study is to develop an earth leakage alarm circuit breaker, equipped with a leakage alarming function (JER-E2S, ETECKOREA Co., Korea), and to analyze its characteristics. The developed mechanism is exclusively used for single-phase and 220 V circuits, with a rated current of 32 A, 20 A, 20 A (for restrooms), 16 A, etc. It satisfies all characteristics of existing earth leakage circuit breakers (ELB). If a fire current, which is a resistive leakage current (Igr), flows through an electric line, the device detects the leakage current in real time and warns against the leakage through a blinking LED lamp. Since the developed device displays a tolerance to a capacitative leakage current (Igc) that inevitably occurs in LED lamps, communication devices, etc., it ensures a stable power supply. In addition, the earth leakage alarm circuit breaker protects against power failure due to a momentary ground fault. Therefore, it can supply power without the risk of the circuit breaker malfunctioning due to a momentary ground fault caused by water droplets, leaves, etc. Moreover, with a standby power of less than 0.1 W, the developed earth leakage alarm circuit breaker exhibits a power saving performance that is 3~8 times greater than that of other ELBs. Installation of approximately 10 earth leakage alarm circuit breakers in one apartment household, with an area of 120 ㎡, can save 2~5 kWh per month. Therefore, the developed earth leakage alarm breaker not only satisfies the characteristics of existing earth leakage breakers, but also exhibits outstanding power supply quality since it has the functions of electric fire prevention and malfunction prevention. Therefore, this device can innovatively contribute to electric fire prevention.

A numerical Study for Improvement of Indoor Air Quality of Apartment House (공동주택 단지의 실내 공기질 향상을 위한 수치 해석적 연구)

  • Shin, Mi-Soo;Kim, Hey-Suk;Hong, Ji-Eun;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.521-530
    • /
    • 2009
  • This study has been made to execute a research in order to lead the improvement of indoor air quality, examining the indoor ventilation characteristics by using a numerical analysis method. To this end an extensive parametric investigation are made according to various external flow variables such as main wind direction and wind speed by season, building layout design, and location of ventilators, etc. in Daedeok Techno Valley, one of large-scaled apartment in Daejeon. It is observed there was a significant difference of main wind direction between summer and winter. The main wind direction in summer was a south wind, and on the contrary the direction in winter is northnorthwest, which is similar to the average main wind direction for 10 years. One of the important calculation results is that the change of wind direction causes a significant effect on the apartment ventilation by the change of pressure difference around each complex of apartment. In case of favorable area of ventilation, the indoor ventilation rate can meet 0.7 ACH from the standard value only with natural ventilation. On the contrary, in other area the value was much lower than the standard value. If the calculation result applies to the design of layout apartment or placement of ventilators, it will be greatly helpful to the energy saving because it can be parallel with the natural ventilation to help securing ventilation rate, not much depending on the mechanical ventilation.

A Study on Time Synchronization Protocol to Cover Efficient Power Management in Ubiquitous Sensor Network (유비쿼터스 센서 네트워크를 위한 효율적인 시간 동기화 프로토콜 연구)

  • Shin, Moon-Sun;Jeong, Kyeong-Ja;Lee, Myong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.896-905
    • /
    • 2010
  • The sensor networks can be used attractively for various application areas. Time synchronization is important for any Ubiquitous Sensor Networks (USN) systems. USN makes extensive use of synchronized time in many contexts for data fusion. However existing time synchronization protocols are available only for homogeneous sensor nodes of USN. It needs to be extended or redesigned in order to apply to the USN with heterogeneous sensor nodes. Because heterogeneous sensor nodes have different clock sources with the SinkNode of USN, it is impossible to be synchronized global time. In addition, energy efficiency is one of the most significant factors to influence the design of sensor networks, as sensor nodes are limited in power, computational capacity, and memory. In this paper, we propose specific time synchronization based on master-slave topology for the global time synchronization of USN with heterogeneous sensor nodes. The time synchronization master nodes are always able to be synchronized with the SinkNode. Then time synchronization master nodes enable time synchronization slave nodes to be synchronized sleep periods. The proposed master-slave time synchronization for heterogeneous sensor nodes of USN is also helpful for power saving by maintaining maximum sleep time.

A Study on the Evaluation of Thermal Transmittance Performance of Aluminum Alloy Window Frame of Educational Facility considering 2 Dimensional Steady-state Heat Transfer (2차원 정상상태 전열해석을 통한 교육시설의 알루미늄 창호 열관류율 평가에 관한 연구)

  • Park, Tong-So
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.5284-5289
    • /
    • 2011
  • This study focused to evaluate thermal transmittance(U-value) performance of sliding type of aluminum alloy window frame(AAWF) with double glazing(DG) and glazing spacer and that without thermal breaker in winter and summer season by two dimensional steady state heat transfer analysis. The AAWE was installed to an existing educational facilities in Seosan area which is the southern region of the Korean Peninsula. Analysis of 2D steady-state heat transfer was performed through the use of BISCO as calculation and simulation program. U-value and temperature factors were calculated. The results are as followed. First, the isotherm simulation shows that AAWF with double glazing have serious differences from recently proposed window thermal performance standards such as Insulation Performance of Windows and Doors of Building Energy Saving Design Standards and the results of calculation of thermal transmittance performance of AAWF and DG are U=9.631 W/$m^2K$, U=2.382 W/$m^2K$ respectively during winter and summer season. Second, the results of analysis of heat transfer analysis, calculated by simulation, shows that 225% of heat is lost comparing with thermal performance standards U=4.0 W/$m^2K$ of general double glazing among those standards on AAWF without thermal breaker.

Control of Temperature and the Direction of Wind Using Thermal Images and a Fuzzy Control Method (열 영상과 퍼지 제어 기법을 이용한 온도 및 풍향 제어)

  • Kim, Kwang-Baek;Cho, Jae-Hyun;Woo, Young-Woon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.11
    • /
    • pp.2083-2090
    • /
    • 2008
  • In this paper, we propose a method for control of temperature and the direction of wind in an air-cooler using thermal images and fuzzy inference rules in order to achieve energy saving. In a simulation for controlling temperature, a thermal image is transformed to a color distribution image of $300{\times}400$ size to analyze the thermal image. A color distribution image is composed of R, G and B values haying temperature values of Red, Magenta, Yellow, Green, Cyan and Blue. Each color has a temperature value from $24.0^{\circ}C$ to $27.0^{\circ}C$ and a color distribution image is classified into height hierarchies from level 1 to level 10. The classified hierarchies have their peculiar color distributions and temperature values are assigned to each level by temperature values of the peculiar colors. The process for controlling overall balance of temperature and the direction of wind in an indoor space is as follows. Fuzzy membership functions are designed by the direction of wind, duration time, and temperature and height values of a color distribution image to calculate the strength of wind. After then, the strength of wind is calculated by membership values of membership functions.

A Proposal on the Consulting Model for Efficient Construction of Material Handling Automation System : Focused on K Company's Case (물류자동화 시스템의 효율적 구축을 위한 컨설팅 방법론 제안 : K기업의 사례를 중심으로)

  • Ko, J.H.;Cho, J.H.;Oh, H.S.;Shim, S.C.;Ryu, J.H.;Lee, S.J.
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.38 no.4
    • /
    • pp.202-211
    • /
    • 2015
  • Companies build the factory automation system to improve management effectiveness and productivity as prime strategies for sustainable growth. But most companies undergo various trials and errors while carrying out the project without elaborate preparation stage for factory automation. In this study, we tried to verify what factors are critical to effectively building distribution automation system, which is a branch of factory automation system. A consulting model for setting up a Material Handling Automation System by utilizing the Stage-Gate Process, which is product development process was studied. 29 material handling automation projects carried out between the year 1990 to 2013 at K-Company were selected. Interviews with the project managers, operators and maintenance personnels, various records and current status of the projects were used as data for structural equations based on the Milan consulting model and existing researches of factory automation, CIM for material handling automation. Creating effective basis of production, material handling system and energy saving system with expert review, when preparing a material handling automation project, help promote the project planning thus contributing to the performance of the resulting system, which appears though rather weakly in our data. Also the effect of material handling automation can be enhanced through sufficient and effective links to the relevant environments such as production logistics management and automated warehouses. More detailed planning characteristics of project promotion or some time-series data of effective Material Handling Automation System could enhace furthur studies. We propose a consulting model for setting up an efficient material handling automation system.