• Title/Summary/Keyword: Saver

Search Result 51, Processing Time 0.034 seconds

Effects of Autotransfusion Using Cell Saver in Cardiovascular Surgery (심혈관수술에서 cell saver를 이용한 자가수혈)

  • 구자홍
    • Journal of Chest Surgery
    • /
    • v.26 no.4
    • /
    • pp.255-259
    • /
    • 1993
  • The efficacy of the autotransfusion system is a reducing the need of intraoperative and postoperative transfusion in cardiovascular surgery. Between January 1990 and December 1991, we experienced 23 cases of autotransfusion using Haemonetic Cell Saver in cardiovascular surgery [Experimental group]. Another 13 cases which were taken similiar operations without Cell Saver during same period [Control group]. The amounts of blood transfused are 4.23 1.84 units in Control group, 2.82 1.84 units in Experimental group. Postoperatively, both groups showed decreased platelet counts, mild prolongation of prothrombin and partial thromboplastin time compred to preoperative value [P<0.001], but there were no significant differences between two group [P=NS]. Plasma hemoglobin was markedly increased in Experimental group compared with Control group [p<0.05]. In Experimental group, amount of average processed blood by Cell Saver was 700ml of which composition was hemoglobin 17mg/dl, hematocrit 50.0%, RBC 5,590,000/ml, WBC 7500/ml, and platelet 40,000/ml. The culture of the processed blood revealed no growth of the organisms. Conclusively, Cell Saver autotransfusion system is a simple, safe, and cost effective method especially in the cases associated with massive bleeding. However, it requires familiarity with system, gentle manipulation of suction tip, and careful selection of candidates to obtain maximal benefits .

  • PDF

Effects of Autotransfusion using Cell Saver in Open Heart Surgery (개심술시 Cell Saver를 이용한 자가수혈의 효과)

  • 윤경찬;최세영;유영선;이광숙;박창권
    • Journal of Chest Surgery
    • /
    • v.31 no.1
    • /
    • pp.28-31
    • /
    • 1998
  • Homologous blood transfusion entails substantial risks, including allergic reactions, transmission diseases such as hepatitis, acquired immunodeficiency syndrome. Autotransfusion system is a common method of reducing the need for homologous blood transfusion during cardiac operation. Between July 1993 and July 1995, a series of 40 patients undergoing open heart surgery was selected to an autotransfusion group(n=20) or a control group(n=20). The cell saver system(AT1000, Electromedics, Englewood, CO, USA) was employed for autotransfusion. With this system, shed blood in operative field during cardiopulmonary bypass(CPB) and remained blood in cardiotomy reservior after CPB was aspirated by means of a locally heparinized collecting system. After centrifuge salvaged blood, the resulting red cell concentrate reinfused subsequently. The amounts of blood loss were 766.5$\pm$121.3 ml in cell saver group, 770.1$\pm$113.6 ml in control group, and there were no significant differences between two groups(P=NS). The amounts of blood transfused were 2.91$\pm$1.72 units in cell saver group, 4.82$\pm$1.72 units in control group. Composition of processed blood by cell saver was hemoglobin 17.4 gm%, hematocrit 56.4%, RBC 5,780,000/ul, WBC 9,900/ul, and platelet 33,000/ul. There was no complication related to cell saver. Conclusively, cell saver autotransfusion system is safe, effective method for reducing the homologous blood trasfusion in cardiac surgery.

  • PDF

Autotransfusion Using Ccell Saver in Cardiac Surgery (개심술에서의 자가수혈기(Cell Saver)를 이용한 자가수혈)

  • 육을수
    • Journal of Chest Surgery
    • /
    • v.28 no.2
    • /
    • pp.125-130
    • /
    • 1995
  • Autotransfusion system is a common method of reducing the need of intraoperative and postoperative homologous blood transfusion in cardiac operation. Between August 1991 and August 1993, a series of 51 adults undergoing open heart surgery was selected. Autotransfusion using Cell Saver [COBE Baylor Rapid Autologous Transfusion System was done with homologous blood transfusion in 15 cases [Group II or without homologous blood transfusion in 17 cases [Group III . The other 19 cases were taken without Cell Saver for control [Group I . The shed blood in the operative field, remained blood in the oxygenator after cardiopulmonary bypass, and blood drained from chest tubes in postoperative care were aspirated by means of a locally heparinized collection system. After the salvaged blood was washed and centrifuged, the processed blood subsequently reinfused. Composition of processed blood by Cell Saver was hemoglobin 16.9gm%, hematocrit 49%, RBC 5,140,000/ml, WBC 670/ml, and platelet 30,000/ml. In three group, hemoglobin, hematocrit, and platelet counts were decreased postoperatively, but no significant differences between three group. Postoperatively, the amounts of drainage from chest tubes was 543$\pm$121ml in Group I, 809$\pm$201ml in Group II, and 631$\pm$147ml in Group III. In Group II, there was large amount of drainage compared with Group I [p<0.05 . The amount of homologous blood transfused was 1116$\pm$219 ml in Group I, 791$\pm$183 ml in Group II [p<0.05 . The homologous blood was not transfused in 17 cases [53% with Cell Saver.Preoperative and postoperative, coagulation parameters showed no significant differences between three group. And there was no complication related to Cell Saver. We conclude that the autotransfusion using Cell Saver is effective for reducing the homologous blood transfusion in cardiac surgery.

  • PDF

Design and Structural Analysis of Electric Saver Box (전력절감기함의 설계 및 구조해석)

  • Lee, Jong-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2435-2440
    • /
    • 2012
  • In this paper, Solidworks was used to do a conceptional design of an box of an electric saver in order to manufacture an electric saver having a different performance and model. Based on this, analysis was made considering weight concentrated on an box. 3-dimensional finite element analysis code, ANSYS was applied to obtain stress, strain and deformation in order to secure durability and these data was reflected to a detailed drawing.

Effects of Autotransfusion using Cell Saver in Cardiac Surgery (개심술시 자가 수혈체계[Cell Saver]의 이용 효과)

  • 안욱수
    • Journal of Chest Surgery
    • /
    • v.25 no.11
    • /
    • pp.1312-1317
    • /
    • 1992
  • Autologous blood transfusion is a common method of reducing the need for homologous blood transfusion during cardiac operations. Between June 1991 and May 1992, 12 cases [Group I] were experienced autologous blood transfusion using Cell Saver undergoing double valve replacement or redo-valve replacement. Control group [N=12, Group II] was selected to above similar operation during same period. The Cell Saver system [Haemonetics Corp.] was employed for autologous blood transfusion. The blood shed in the operative field before and after cardiopulmonary bypass and remained cardiotomy reservior was aspirated by means of a locally heparinized collecting system. After centrifused salvaged blood, the resulting red cell concentrate reinfused subsequently. The patient receiving autologous blood transfusion required significantly less homologous blood transfusion than their control group. [Group I; 3519 $\pm$ 869, Group II; 4622 $\pm$ 856, Respectively; P=0.005] There were no clinical infections in the autotransfusion group. And there was no apparent intergroup difference of the clinical findings, hematologio datas and coagulation parameters. We conclude the autotransfusion using Cell Saver is effective for reducing of the hom-ologlous blood transfusion in cardiac surgery.

  • PDF

A Study of Implementation Automatic Screen Saver using Division of Difference Image (분할 차영상을 이용한 전시 자동 스크린세이버 구현 기법)

  • An, Hyun-Soo;Kim, Hye-Young
    • Journal of Digital Contents Society
    • /
    • v.14 no.3
    • /
    • pp.303-311
    • /
    • 2013
  • On original exhibits, which is passive and repeat itself endlessly irrelevant of the present of spectators, reduce its immersion. Therefore in this paper, we propose the scheme to recreate original exhibits be adding automatic screen saver by using division of different images to make experimental of an area of different images, to judge movement, maintain conditions or to propose the transition of mechanism. By implementing and analyzing this automatic screen saver, which was made through the scheme of proposition, we show the positive aspect of the use of centralized automatic screen saver.

A Study on the Classification Of the Household Financial Strategies (가계 재무전략의 유형화에 관한 연구 -1999년과 2000년 한국노동패널자료를 중심으로-)

  • 박진영;문숙재
    • Journal of Families and Better Life
    • /
    • v.22 no.2
    • /
    • pp.85-95
    • /
    • 2004
  • The purpose of this study was to classify the household financial strategies and find out variables affecting the type of the household financial strategies. The data of 3994 households from Korean Labor and Income Panel Study(1999-2000) were used. The major findings were as follows: (1) the household financial strategies were Residual Saver Type(44.6%), Unformal Institute Saver Type(13.3%), Financial asset Saver Type(16.7%), Real estate Saver Type(13.4%) and Diversities(12.0%). (2) The household financial strategy types were changed rapidly during short term. (3) In 3994 households, the variables which influence on the change of the household financial strategies were education, job, numbers of children, place of residence, home ownership. Similarly, in each type, the change of household financial strategies was significantly different according to the household characteristics variables.

Effects of Autotransfusion using Cell Saver in Cardiac Surgery (개심술시 Cell Saver 를 이용한 자가수혈의 효과)

  • 정경영
    • Journal of Chest Surgery
    • /
    • v.23 no.2
    • /
    • pp.260-267
    • /
    • 1990
  • During a eight month period[from December, 1988 to July, 1989], a series of 35 adults undergoing redo-valve replacement or coronary artery bypass grafting was selected to an autotransfusion group[n=10] or a control group[n=25]. The Cell Saver System[Haemonetics Corp., Graintree, Mass] was employed for autotransfusion. With this system, all blood shed in the operative field before and after cardiopulmonary bypass and remained in cardiotomy reservoir after cardiopulmonary bypass was aspirated by means of a locally heparinized collecting system. After the salvaged blood was centrifuged, the resulting red cell concentrate subsequently reinfused. The patients receiving autologous blood required significantly less banked homologous blood than their controls[3213k1020 ml and 506051931 ml, respectively: p=0.001] There were no clinical infections in the autotransfusion group, although 40% of the cultures of processed blood were positive. And there was no apparent intergroup difference of the clinical and the hematologic and hemostatic laboratory findings. We conclude that autotransfusion using cell saver is effective for saving the homologous blood transfusion in cardiac surgery.

  • PDF

A Study on the Energy Saving and Electric Fire Prevention was Caused by with Interception of Standby Electric Power (대기전력차단으로 인한 에너지절약과 전기화재예방에 관한 연구)

  • Kim, Man-Gun;Lim, Seong-Jin;Lee, Chang-Woo
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.66-73
    • /
    • 2008
  • In this research, the electric power consumptions of the electrical machinery and appliances selected in the Seoul division of Korea Electrical Safety Corporation were measured. The power-saving efficiency was investigated by comparing the amounts of the reserved electric power when the Saver was on or off through measuring that of the reserved electric power before and after equipping the selected appliances with the Saver, a cutoff of the reserved electric power. As a result, the power-saving efficiency was around 18% when the Saver was installed. It can be ascribed to the removal of the source wasting electrical energy. Furthermore, by blocking the reserved electric power, the electric fire can be originally prevented and also the life time of the electrical machinery and appliances can be postponed.

  • PDF